1 |
[en] DEVELOPMENT OF ANALYTICAL METHODS BASED ON LUMINESCENCE AND ELECTROPHORESIS FOR THE DETERMINATION OF ALKALOIDS (BETA-CARBOLINES, CAMPTOTHECIN AND DERIVATIVES) OF PHARMACOLOGICAL INTEREST / [pt] DESENVOLVIMENTO DE MÉTODOS ANALÍTICOS ESPECTROLUMINESCENTES E ELETROFORÉTICOS PARA A DETERMINAÇÃO DE ALCALOIDES (BETA-CARBOLINAS, CAMPTOTECINA E DERIVADOS) DE INTERESSE FARMACOLÓGICOFLAVIA FERREIRA DE CARVALHO MARQUES 14 October 2009 (has links)
[pt] Métodos analíticos foram desenvolvidos para a determinação seletiva de
alcalóides de interesse farmacológico. Com o objetivo de permitir a determinação
seletiva de camptotecina (CPT) em formulações farmacêuticas de irinotecana
(CPT-11) ou de topotecana (TPT), dois métodos espectrofluorimétricos e um
eletroforético, com detecção por fotometria de absorção, foram propostos. Os
métodos espectrofluorimétricos permitiram a determinação seletiva de CPT
usando um ajuste de alcalinidade do meio associado ao uso de varredura
sincronizada ou de derivada de 2ª ordem. Alternativamente, o procedimento de
derivação fotoquímica (com otimização com planejamento composto central)
eliminou completamente as interferências no sinal do CPT. Nas condições
otimizadas, a espectrofluorimetria permitiu a determinação de CPT em misturas
contendo até 50 vezes mais TPT ou contendo até 10 vezes mais CPT-11. A
resposta analítica indicou faixas lineares de trabalho e homoscedasticidade. O
limite de detecção (LD) foi da ordem de 10(-10) mol L(-1) para o método baseado na
derivação fotoquímica e uma ordem de grandeza a menos para os métodos sem
derivatização fotoquímica. Testes foram feitos em medicamentos a base de TPT
e de CPT-11 e as recuperações ficaram em torno de 100%. Esses resultados
foram comparáveis aos obtidos com método de referência (HPLC). O estudo de
incerteza de medição por fluorimetria indicou que a maior contribuição do
processo era a preparação de solução por avolumação. A contribuição dessa
fonte foi minimizada pela preparação de solução por meio de ajuste de massa,
causando um grande impacto na redução da incerteza expandida. O método
baseado na eletroforese eletrocinética capilar micelar (MEKC) permitiu a
quantificação simultânea de TPT, CPT e CPT-11. Para conseguir o ajuste final
das melhores condições, foi feito um estudo univariado seguido de um
planejamento composto central. Para se melhorar a sensibilidade da detecção
em até 76 vezes, foi utilizado um processo de pré-concentração no capilar por
modo de empilhamento e uma cela de caminho óptico alongado. A escolha do
tampão borato (pH 8,5) contendo SDS e acetonitrila permitiu condições robustas 7
de sinal de tempo de migração. A resposta analítica mostrou faixa linear e
homoscedatidade, além de repetitividade em torno de 3,5%. O LD foi da ordem
de 10(-7) mol L(-1) (TPT) e 10(-8) mol L(-1) (CPT-11 e CPT). Testes de recuperação em
amostras de saliva fortificadas foram feitos e comparados com os obtidos por um
método de referência (HPLC) de forma a mostrar a exatidão adequada para o
método proposto. Para a determinação seletiva de B-carbolinas, a fosforimetria
em substrato sólido (SSRTP) foi utilizada. O ajuste do átomo pesado seletivo e a
aplicação de técnica de varredura sincronizada e de 2ª derivada aumentaram o
grau de seletividade, pois induziu fosforescência dos analitos de interesse na
amostra e melhorou a resolução espectral em relação aos interferentes. O ajuste
da quantidade de HgCl2 (0,81 mg) permitiu a determinação seletiva de harmol na
presença de quantidades até 10 vezes maiores de harmine, harmane,
norharmane e harmaline. O método SSRTP seletivo proposto para determinação
de harmol foi comparado com o resultado obtido por um método de referência
adaptado baseado em MEKC, o qual também mostrou sua capacidade para a
determinação seletiva de harmol na presença dos interferentes. LD absoluto na
ordem de ng e comportamento linear da resposta analítica foram obtidos. No
caso do método analítico desenvolvido para a determinação de harmane na
presença de harmine em chás, estudos de otimização mostraram o AgNO3 como
sal de átomo pesado no substrato, solução de amostra em pH 11 e medições
feitas em 322 nm do espectro de 2ª derivada da varredura sincronizada
((delta)(lambda) = 109 nm). Testes de interferência mostraram que a matriz do chá não tem
influência no sinal do harmane e que nas / [en] Analytical methods were developed for the selective determination of
alkaloids of pharmacological interest. Aiming the selective determination of
camptothecin (CPT) in irinotecan (CPT-11) or topotecan (TPT) based
pharmaceutical formulations, two spectrofluorimetric methods and one
electrophoretic method with absorciometic detection were proposed. The
spectrofluorimetric method allowed the determination of CPT using the
adjustment of the alkalinity of the sample solution associated with the use of
synchronous scanning or 2nd order spectral derivation. Alternativelly, the
photochemical derivatization (optimized by central composite design) completely
eliminated interferences on the CPT signal. The optimized conditions allowed the
spectrofluorimetric determination of CPT in mixtures containing up to 50 times
more TPT or up to 10 times more CPT-11. The analytical response presented
linear working ranges and homocedasticity. The limit of detection (LD) was in the
order of 10(-10) mol L(-1) for the method based on photochemical derivatization and
one order of magnitude higher for the methods without photochemical
derivatization. Tests were made using TPT and CPT-11 based comercial drugs
and recoveries were around 100%. Such results were comparable to those
obtained with the reference method (HPLC). A study of fluorimetric measurement
uncertainty indicated that the greatest contribution in the process was the
preparation of solution by volume. The contribution from this source was
minimized by the preparation of solutions by weight measurement which caused
a major impact in reducing the expanded uncertainty. The method based on
micellar electrokinetic capillary electrophoresis (MEKC) allowed the simultaneous
quantification of TPT, CPT and CPT-11. To achieve final adjustment of
conditions, an univariated study was made followed by a central composite
design. To improve the sensitivity of detection up to 76 times, a pre-concentration
in the capillary by the normal stacking mode was used along with an extended
optical path cell. The choice of borate buffer (pH 8.5) containing SDS and
acetonitrile implicated in robust conditions of signal and migration times. The
response showed analytical linear working range and homocedasticity, and
9 repeatability of around 3.5%. The LD was in the order of 10(-7) mol L(-1) (TPT) and
10(-8) mol L(-1) (CPT-11 and CPT). Recovery tests using spiked saliva samples were
made and compared with those obtained by a reference method (HPLC) to show
the appropriated accuracy for the proposed method. For the selective
determination of B-carbolines, solid surface room temperature phosphorimetry
(SSRTP) was used. The adjustment of the selective heavy atom and the
application of synchronized scanning technique and 2nd order spectral derivation,
increased the degree of selectivity, because induced phosphorescence of the
analytes of interest in the sample and improved spectral resolution. The
adjustment of the amount of HgCl2 (0.81 mg) allowed the selective determination
of harmol in the presence of up to 10 times higher amounts of harmine, harman,
harmaline and norharman. The method proposed for selective SSRTP
determination of harmol was compared with the results obtained by an adapted
method based on MEKC, which also showed its ability to determine harmol in the
presence of interferences. The absolute limit of detection in the ng order and
linear behavior of the analytical response was obtained. For the analytical
method developed for the determination of harman in the presence of harmine in
teas, optimization studies indicated the following conditions: AgNO3 as the heavy
atom salt deposited on the substrate, sample solution at pH 11 and
measurements made at 322 nm of the 2nd order derivated synchronous scanning
spectrum ((delta)(lambda) = 109 nm). Tests showed that, in optimized conditions, the tea
matrix had no influence on the harman signal and and that harman could be
determined in samples containing harmine in concentrations up to two times
higher. The
|
2 |
[en] CHLOROPHYLL A DETERMINATION IN MARINE WATER BY FLUORESCENCE / [pt] MEDIDAS DA CLOROFILA A EM ÁGUAS MARINHAS POR FLUORESCÊNCIAANA GABRIELA BARBOSA MATOS 18 December 2001 (has links)
[pt] A clorofila a é um composto-chave no processo de absorção e
aproveitamento da energia luminosa na fotossíntese.
Monitorar a fluorescência da clorofila a para obter
informações do aparato fotossintético de produção de
energia é uma abordagem atraente porque a fluorescência á
percebida externamente às células, podendo ser detectada sem
destruir sua fonte. Estudos anteriores realizados pelo
Laboratório de Hidrobiologia (UFRJ) e pelo Laboratório de
Monitoramento Ambiental Remoto (LabMAR) (PUC-Rio) em águas
marinhas indicaram a existência de uma relação linear entre
os valores absolutos obtidos pelo Laboratório de
Hidrobiologia para a concentração da clorofila a e os
valores relativos obtidos pelo LabMAR para a sua
fluorescência. Este resultado motivou os dois laboratórios
a obter valores absolutos para a concentração da clorofila
a em águas marinhas, a partir da medida de sua
fluorescência, com a maior confiabilidade possível para,
então, relacioná-los aos valores relativos fornecidos pelo
LIDAR-PUC. Neste sentido, a implantação de um programa de
controle de qualidade no Laboratório de Hidrobiologia
indicou que este laboratório encontra-se em condições de
obter valores confiáveis para a concentração da clorofila a
em amostras de águas marinhas através da fluorimetria. No
entanto, uma avaliação rigorosa da relação entre a
intensidade da fluorescência da clorofila a (normalizada
pela intensidade da emissão do espalhamento Raman da água)
e o respectivo valor confiável para a concentração da
clorofila a se faz necessária. / [en] Chlorophyll a is a key-compound in the process of light
absorption in the photosynthesis. Monitor the chlorophyll a
fluorescence to obtain information about the photosynthetic
apparatus of energy production is attractive because the
chlorophyll a fluorescence could be detected without
destruction of the source. Studies performed by the
Laboratório de Hidrobiologia (UFRJ) and by the Laboratório
de Monitoramento Ambiental Remoto (LabMAR) (PUC-Rio) in
marine water samples indicated a linear relation between
the absolute values obtained by the former for the
chlorophyll a concentration and the relative values
obtained by the latter for the chlorophyll a fluorescence.
This result motivated both laboratories to obtain absolute
values for the chlorophyll a concentration, in marine water
samples, as confident as possible and, then, relate these
values to the relative values generated by the LIDAR-PUC.
In this way, the introduction of a quality control program
in the Laboratório de Hidrobiologia indicated that this
laboratory is able to analyse marine water samples and to
obtain confident values for the chlorophyll a concentration
by fluorimetry. However, a more rigorous evaluation of the
relation between the chlorophyll a fluorescence and the
respective confident value for the chlorophyll a
concentration is still necessary.
|
3 |
[en] DEVELOPMENT AND METROLOGICAL VALIDATION OF A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE QUANTIFICATION OF CYCLOFENIL AFTER PHOTOCHEMICAL DERIVATIZATION / [pt] DESENVOLVIMENTO E VALIDAÇÃO METROLÓGICA DE MÉTODO ANALÍTICO POR CROMATOGRAFIA LÍQUIDA DE ALTA EFICIÊNCIA PARA A QUANTIFICAÇÃO DE CICLOFENIL APÓS DERIVAÇÃO FOTOQUÍMICAJUAN JOSE GARCIA ANTONIO 22 October 2013 (has links)
[pt] O ciclofenil é um medicamento antiestrogênico usado em tratamentos de distúrbios ovarianos. Por outro lado, esse efeito em homens resulta em aumento de massa muscular, sendo seu uso proibido para atletas do sexo masculino pelo código mundial antidoping estabelecido pela WADA. Os métodos de espectrofotometria de absorção e de fluorescência permitem quantificar direta ou indiretamente o ciclofenil, porém não são adequados para a análise de amostras mais complexas. Este trabalho propõe o desenvolvimento de um método baseado na cromatografia líquida de alta eficiência para determinação de ciclofenil usando detecção por fluorescência, após a fotoderivação do ciclofenil. A separação utiliza eluição isocrática (tampão borato 10 mmol/L(-1), pH 10/metanol/ 60/40 por cento v/v), e coluna C18 mantida a 35 graus Celsius. Após a fotoderivação com UV, formaram-se fotoderivados luminecentes, como previsto na literatura, sendo que o fotoderiado com tempo de retenção igual a 2,7 min foi o escolhido para fins quantitativos por ser estável ao longo de 96 h após o processo de derivatização. Foram obtidos os limites de detecção de 6,6 x 10(-8) mol/L(-1) e de quantificação de 7,3 x 10(-7) mol/L(-1). A faixa de resposta linear se extendeu até 5 x 10(-5) mol/L(-1) (de ciclofenil). As recuperações obtidas em formulações farmacêuticas se apresentaram entre 94 e 105 por cento. Os resultados indicaram que a homogeneidade e estabilidade dos medicamentos de ciclofenil são satisfatórias. As fontes que mais contribuiram para a incerteza de medição estão associadas ao preparo das soluções e à construção da curva analítica. / [en] Cyclofenil is an anti-estrogen used in treatments of ovarian disorders. On the other hand, its effect in men results in the increasing of muscle mass, being its use, by male athletes, banned by the World Anti-Doping Code established by World Anti-Doping Agency. Absorption and fluorescence spectrophotometries allow direct or indirect quantification of cyclofenil, however, they are not suitable for the analysis of complex samples. This work proposes the development of a method based on high performance liquid chromatography to determine cyclofenil using photochemical induced fluorescence detection. The separation using isocratic elution (10 mmol/L(-1) borate buffer at pH 10/methanol (60/40 per cent v/v), and column C18 maintained at 35 degrees celsius. After exposing cyclofenil to the UV, fluorescent photoderivatives were formed, as indicated in the literature, with the photoderivative with the retention time of 2.7 min used for quantitative purposes since it is stable for over 96 h after the photoderivatization procedure. The detection limit was 6.6 x 10(-8) mol/L(-1) and the limit of quantification was 7.3 x 10(-7) mol/L(-1). The linear response range extended up to 5 x 10(-5) mol/L(-1) (as cyclofenil). Recoveries in pharmaceutical formulations were between 94 and 105 per cent. The results indicated that the homogeneity and stability of cyclofenil tablets are satisfactory. The uncertainty sources that present the greatest contributions to the measurement uncertainty were the ones associated with the preparation of the solutions and the analytical curve.
|
Page generated in 0.3177 seconds