Avaliação de configurações de sistemas fotovoltaicos na região Nordeste do Brasil / Evaluation of photovoltaic system configurations in the Northeastern region of Brazil

Luiz Fernando Almeida Fontenele 23 October 2018 (has links)
Neste trabalho, são avaliadas diferentes configurações de sistemas fotovoltaicos, levando em consideração os principais tipos de módulos fotovoltaicos comercialmente disponíveis e estruturas de suporte. A comparação é delimitada na região Nordeste do Brasil e é baseada, fundamentalmente, em termos de fator de capacidade. Para uma melhor compreensão dos resultados, são mostradas, previamente, as influências que as variáveis meteorológicas exercem na saída do sistema, bem como os efeitos do fator de dimensionamento do inversor (FDI) e do índice de cobertura do terreno (ICT). Os resultados das simulações computacionais realizadas são apresentados em forma de mapas, nos quais é possível verificar as áreas em que os sistemas fotovoltaicos tendem a gerar mais energia elétrica. Entre as configurações estudadas, os maiores valores foram observados para sistemas que utilizam módulos genéricos de filmes finos montados em rastreadores solares de um eixo horizontal, chegando a 36 % de fator de capacidade (em corrente alternada) em algumas regiões do Ceará, Rio Grande do Norte, Paraíba, Pernambuco e Bahia. Além disso, foram evidenciados os ganhos obtidos nos fatores de capacidade ao substituir as estruturas fixas por rastreadores solares. Para um ICT de 0,4, os sistemas que realizam o seguimento, ainda que em um eixo do movimento aparente do Sol, apresentaram ganhos de 18 % a 28 % na energia elétrica anual gerada. / In this work, different configurations of photovoltaic systems are evaluated, considering the main type of commercially available photovoltaic modules and mounting structures. The comparison is delimited to the Northeastern region of Brazil and is based, fundamentally, in terms of capacity factor. The influence on the output of the system of meteorological variables, the inverter loading ratio (ILR 1/FDI) and ground coverage ratio (GCR ICT) are shown in advance for a better understanding of the results. Computational simulations results are presented in maps, in which it is possible to verify the areas where photovoltaic systems tend to generate more electricity. Among the studied configurations, the largest values were observed for systems that use generic thin film modules mounted on one axis horizontal solar trackers, reaching 36 % of capacity factor (in alternating current) in some regions of Ceará, Rio Grande do Norte, Paraíba, Pernambuco and Bahia. Additionally, the gains obtained in the capacity factors when replacing fixed structures by solar trackers were shown. For an GCR of 0.4, systems that track, even on one axis, the apparent motion of the Sun showed gains of 18 % to 28 % on annual generated electricity.
12

Análise de um mecanismo de compensação de reativos incorporado aos inversores de um sistema fotovoltaico conectado à rede elétrica / Analysis of a reactive power compensation mechanism incorporated into inverters of a grid-connected photovoltaic system

Benedito, Ricardo da Silva 14 November 2014 (has links)
No Brasil, quando uma unidade consumidora (UC) sob regime de microgeração ou de minigeração distribuída tem parte ou a totalidade da sua demanda por potência ativa suprida pela planta geradora, mas sua demanda por potência reativa é atendida exclusivamente pela rede elétrica, verifica-se uma aparente deterioração do fator de potência dessa UC, sob a ótica da concessionária. Esse efeito decorre do fato de que o fator de potência, de acordo com a regulamentação vigente, é determinado apenas a partir das medições dos fluxos de potência ativa e reativa trocados entre a UC e a rede elétrica e não também entre a planta geradora e UC. Para consumidores do Grupo A (tensão de fornecimento igual ou superior a 2,3 kV) nessa situação, de acordo com o perfil da carga, pode haver cobrança por excedentes de reativos, constituindo-se assim uma barreira. Especificamente no caso de sistemas fotovoltaicos conectados à rede, existe a possibilidade de se utilizar os próprios inversores c.c.-c.a para suprir a demanda de reativos da UC e, dessa forma, minimizar o problema apresentado. Com o objetivo de se avaliar essa alternativa no contexto brasileiro, tendo-se em vista condições reais de operação e os limites normativos de injeção de potência reativa para inversores de sistemas fotovoltaicos, foi realizado um estudo de caso de uma planta fotovoltaica instalada no telhado do prédio da Administração do Instituto de Energia e Ambiente da Universidade de São Paulo. O estudo mostrou que a compensação realizada por meio do inversor selecionado evitou a cobrança de excedentes de reativos sem afetar de forma significativa a produtividade do sistema fotovoltaico. Do ponto de vista elétrico, verificou-se que a injeção de reativos pelo inversor não provocou variações significativas de tensão no ponto de acoplamento ou no alimentador e, ainda, se verificou considerável liberação de capacidade do sistema supridor da concessionária. Dessa forma, a análise dos resultados indica uma tendência a se considerar a compensação de reativos proporcionada pelo próprio inversor a opção mais viável para se lidar com os excedentes de reativos, comparativamente a métodos convencionais de compensação ou à situação em que nenhuma ação compensatória seja implementada. / In Brazil, when a consumer unit (CU) under a distributed microgeneration or minigeneration scheme has part or all of its demand for active power supplied by the generating plant, but its demand for reactive power is served exclusively by the grid, the power factor of this CU appears deteriorated, from the perspective of the utility. This effect is due to the fact the power factor, according to the current regulations, is determined only from measurements of the flows of active and reactive power exchanged between the UC and the grid and not also between the generating plant and UC. Users of group A (supply voltage equal to or greater than 2.3 kV) in this situation, according to the CU load profile, may be charged due the reactive power excess, thus constituting a barrier. Specifically in the case of grid-connected photovoltaic systems, there is the possibility of using the d.c.- a.c. inverters to suply the CU reactive power demand and, thus, minimizing the presented problem. In order to evaluate this alternative in the Brazilian context, keeping in view real operating conditions and regulatory limits for the reactive power injection for photovoltaic inverters, we conducted a case study with a photovoltaic plant installed on the roof of the University of São Paulo Institute for Energy and Environment administration building. The study showed that the compensation performed by the selected inverter prevented the reactive power excess charging without affecting significantly the photovoltaic system productivity. From an electrical point of view, it was found that the injection of reactive power by the inverter did not cause significant voltage variations at the coupling point or at the transformer and, additionally, there was a significant release in the utility suply system capacity. Thus, the analysis results indicates a tendency to consider the compensation provided by the inverter itself the most viable option for dealing with the surplus of reactive power compared to conventional compensation methods or to the situation in which no compensatory action is implemented.
13

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
14

Análise da influência de diferentes estratégias de arrefecimento no desempenho e durabilidade de inversores de sistemas fotovoltaicos conectados à rede

Perin, Aryston Luiz January 2016 (has links)
Inversores de sistemas fotovoltaicos são equipamentos de eletrônica de potência que fornecem energia elétrica em corrente alternada (CA) a partir de uma fonte de energia elétrica em corrente contínua (CC), no caso, os módulos fotovoltaicos. Estes inversores quando em operação aumentam sua temperatura. Este aumento de temperatura é indesejável, porém é inerente ao seu funcionamento. Equipamentos eletrônicos possuem um limite seguro de temperatura de operação, acima do qual podem ocorrer instabilidades de operação, redução da vida útil ou até mesmo falha drástica. O conhecimento da eficiência de conversão elétrica e das perdas responsáveis pelo aquecimento é importante para o adequado dimensionamento de inversores quando aplicados em sistemas fotovoltaicos conectados à rede, assim como para o desenvolvimento do inversor como produto. Para proteção, para aumento da vida útil, para maior confiabilidade, para maior estabilidade e para maior segurança de operação de componentes, inversores possuem rotinas em seus algoritmos de controle com estratégias automatizadas dedicadas ao gerenciamento térmico. Estas rotinas de proteção e gerenciamento térmico, sempre quando acionadas, tendem a reduzir a capacidade de conversão de potência do inversor, seja pelo acionamento de um ventilador auxiliar, seja pelo deslocamento do ponto de operação em máxima potência. Fabricantes de inversores tratam deste assunto pelo termo “temperature derating” (em inglês) Esta tese apresenta um estudo relacionado a influência da temperatura sobre o desempenho de inversores fotovoltaicos conectados à rede. Avalia tipos de estratégias de gerenciamento térmico e proteção de uso corrente em inversores comerciais. Apresenta resultados de ensaios experimentais para determinação de parâmetros térmicos característicos dos inversores. Descreve um modelo preditivo da temperatura de operação em regime transiente. A partir da determinação experimental de parâmetros térmicos, o modelo preditivo de temperatura de operação foi implementado no software de simulação dinâmica para dimensionamento e avaliação de sistemas fotovoltaicos FVCONECT, desenvolvido no LABSOL/UFRGS, estando o mesmo apto para simular a operação e estimar perdas anuais de desempenho energético decorrentes das rotinas de gerenciamento térmico, dos seus efeitos e das limitações impostas durante a operação de inversores fotovoltaicos conectados à rede. Um dos resultados da simulação é a evolução da temperatura do inversor, permitindo avaliar a frequência e amplitude dos ciclos térmicos ao qual o inversor é submetido e, consequentemente, determinar uma estimativa para durabilidade do inversor. / Photovoltaic inverters are electronic power devices that provide electrical energy in alternating current (AC) from a source of electrical energy in direct current (DC) - a photovoltaic generator, in this case. Inverters increase their temperature when in operation. This rise in temperature is not desirable, but inherent to its operation. Any electronic equipment has a safe operating temperature limit. When this limit is surpassed, operating instability, life reduction or even drastic failure may occur. The knowledge of the electrical conversion efficiency and the losses responsible for the heating is important for the proper sizing of grid-tie inverters in photovoltaic systems, as well as for the development of the inverter as a product. In order to increase the useful life of the device and its components, for greater reliability, safety, stability and security of operation, inverters have routines in their algorithms of control with automated strategies dedicated to the thermal management. These protection and thermal management routines, whenever activated, tend to reduce the power conversion capacity of the inverter, either by the activation of an auxiliary fan or by the displacement of the operating point at maximum power. Inverter manufacturers address this issue by the term "temperature derating". This thesis presents a methodology to evaluate the influence of the performance of different strategies to avoid excessive temperature of the inverter components on its performance and durability It is also made an evaluation of different thermal management strategies and protection used in commercial inverters. Results of experimental tests for determination of thermal parameters characteristic of the inverters are presented. A predictive model of transient operating inverter temperature is also described. From the experimental determination of thermal parameters, the predictive model of operating temperature was implemented to the FVCONECT, a dynamic simulation software for sizing and evaluation of photovoltaic systems developed in LABSOL / UFRGS. With this modification, the software was able to simulate the operation and estimate losses of energy due to the thermal management routines, their effects and the limitations imposed during the operation of grid-tie inverters. One of the results of the simulation is the evolution of the inverter temperature, allowing to evaluate the frequency and amplitude of thermal cycles to which the inverter is subjected and, as a consequence, an estimate of durability of the inverter.
15

Análise da influência de diferentes estratégias de arrefecimento no desempenho e durabilidade de inversores de sistemas fotovoltaicos conectados à rede

Perin, Aryston Luiz January 2016 (has links)
Inversores de sistemas fotovoltaicos são equipamentos de eletrônica de potência que fornecem energia elétrica em corrente alternada (CA) a partir de uma fonte de energia elétrica em corrente contínua (CC), no caso, os módulos fotovoltaicos. Estes inversores quando em operação aumentam sua temperatura. Este aumento de temperatura é indesejável, porém é inerente ao seu funcionamento. Equipamentos eletrônicos possuem um limite seguro de temperatura de operação, acima do qual podem ocorrer instabilidades de operação, redução da vida útil ou até mesmo falha drástica. O conhecimento da eficiência de conversão elétrica e das perdas responsáveis pelo aquecimento é importante para o adequado dimensionamento de inversores quando aplicados em sistemas fotovoltaicos conectados à rede, assim como para o desenvolvimento do inversor como produto. Para proteção, para aumento da vida útil, para maior confiabilidade, para maior estabilidade e para maior segurança de operação de componentes, inversores possuem rotinas em seus algoritmos de controle com estratégias automatizadas dedicadas ao gerenciamento térmico. Estas rotinas de proteção e gerenciamento térmico, sempre quando acionadas, tendem a reduzir a capacidade de conversão de potência do inversor, seja pelo acionamento de um ventilador auxiliar, seja pelo deslocamento do ponto de operação em máxima potência. Fabricantes de inversores tratam deste assunto pelo termo “temperature derating” (em inglês) Esta tese apresenta um estudo relacionado a influência da temperatura sobre o desempenho de inversores fotovoltaicos conectados à rede. Avalia tipos de estratégias de gerenciamento térmico e proteção de uso corrente em inversores comerciais. Apresenta resultados de ensaios experimentais para determinação de parâmetros térmicos característicos dos inversores. Descreve um modelo preditivo da temperatura de operação em regime transiente. A partir da determinação experimental de parâmetros térmicos, o modelo preditivo de temperatura de operação foi implementado no software de simulação dinâmica para dimensionamento e avaliação de sistemas fotovoltaicos FVCONECT, desenvolvido no LABSOL/UFRGS, estando o mesmo apto para simular a operação e estimar perdas anuais de desempenho energético decorrentes das rotinas de gerenciamento térmico, dos seus efeitos e das limitações impostas durante a operação de inversores fotovoltaicos conectados à rede. Um dos resultados da simulação é a evolução da temperatura do inversor, permitindo avaliar a frequência e amplitude dos ciclos térmicos ao qual o inversor é submetido e, consequentemente, determinar uma estimativa para durabilidade do inversor. / Photovoltaic inverters are electronic power devices that provide electrical energy in alternating current (AC) from a source of electrical energy in direct current (DC) - a photovoltaic generator, in this case. Inverters increase their temperature when in operation. This rise in temperature is not desirable, but inherent to its operation. Any electronic equipment has a safe operating temperature limit. When this limit is surpassed, operating instability, life reduction or even drastic failure may occur. The knowledge of the electrical conversion efficiency and the losses responsible for the heating is important for the proper sizing of grid-tie inverters in photovoltaic systems, as well as for the development of the inverter as a product. In order to increase the useful life of the device and its components, for greater reliability, safety, stability and security of operation, inverters have routines in their algorithms of control with automated strategies dedicated to the thermal management. These protection and thermal management routines, whenever activated, tend to reduce the power conversion capacity of the inverter, either by the activation of an auxiliary fan or by the displacement of the operating point at maximum power. Inverter manufacturers address this issue by the term "temperature derating". This thesis presents a methodology to evaluate the influence of the performance of different strategies to avoid excessive temperature of the inverter components on its performance and durability It is also made an evaluation of different thermal management strategies and protection used in commercial inverters. Results of experimental tests for determination of thermal parameters characteristic of the inverters are presented. A predictive model of transient operating inverter temperature is also described. From the experimental determination of thermal parameters, the predictive model of operating temperature was implemented to the FVCONECT, a dynamic simulation software for sizing and evaluation of photovoltaic systems developed in LABSOL / UFRGS. With this modification, the software was able to simulate the operation and estimate losses of energy due to the thermal management routines, their effects and the limitations imposed during the operation of grid-tie inverters. One of the results of the simulation is the evolution of the inverter temperature, allowing to evaluate the frequency and amplitude of thermal cycles to which the inverter is subjected and, as a consequence, an estimate of durability of the inverter.
16

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
17

Caracterização da geração distribuída de eletricidade por meio de sistemas fotovoltaicos conectados à rede, no Brasil, sob os aspectos técnico, econômico e regulatório / Characterization of the Distributed Generation of electricity by Grid-Connected Photovoltaic Systems in Brazil, with respect to technical, economic and regulatory aspects.

Ricardo da Silva Benedito 29 October 2009 (has links)
Este trabalho caracteriza a Geração Distribuída de eletricidade, no Brasil, por meio de Sistemas Fotovoltaicos Conectados à Rede (SFCR), a partir de aspectos técnicos, econômicos e regulatórios. O país possui, atualmente, 35 SFCR em operação, totalizando uma potência instalada de 161,32 kWp. A maior parte dessa potência se encontra nas Regiões Sul e Sudeste e foi implementada por universidades, centros de pesquisa e concessionárias de energia elétrica, com uma pequena participação da iniciativa privada. Foi calculado o custo de geração, a partir da energia solar, utilizando-se SFCR, para dezesseis localidades estrategicamente selecionadas. Esse valor varia em função da maior ou menor disponibilidade do recurso solar e da taxa de desconto adotada, tendo sido encontrado o valor médio de US$ 0,56 /kWh, cerca de 2,1 vezes maior que a tarifa residencial média nas mesmas cidades. Argumentando-se que a tarifa convencional tende a crescer nos próximos anos, pressionada pelo descompasso entre oferta e demanda, e que o custo de geração fotovoltaico tende a diminuir, no mesmo período, devido a ganhos de produtividade no processo de fabricação de componentes fotovoltaicos, elaborou-se um modelo matemático para prever o momento em que esses dois indicadores equiparar-se-ão. Verificou-se que o tempo médio de equiparação será de 7 anos, podendo ser menor que 5,0 anos em localidades onde a tarifa é mais cara que a média nacional e a irradiação média anual é superior à verificada no restante do país. Por fim, o trabalho analisa o enquadramento que a legislação faz dos geradores fotovoltaicos interligados à rede pública de distribuição, apontando os pontos favoráveis e os entraves legais à disseminação dos SFCR. / This work characterizes the Distributed Generation of electricity from Grid-Connected Photovoltaic Systems (GCPS) in Brazil, according to technical, economic and regulatory aspects. The country currently has 35 GCPS in operation, totaling an installed power of 161.32 kWp. Most of this power is in the South and Southeast and has been implemented by universities, research centers and electric power utilities, with a small participation of private initiative. The solar energy generation cost from GCPS was calculated for sixteen strategically selected localities. This value varies varies according to the greater or minor availability of the solar resource and the adopted discounting rate. The average value found was 0.56 US$ /kWh, about 2,1 times bigger than the average residential tariff in the same cities. Arguing that the conventional tariff tends to grow in coming years, pressed by the imbalance between supply and demand, and that the cost of photovoltaic generation tends to decrease over the same period due to productivity gains in the manufacturing process of photovoltaic components, a mathematical model was developed to predict the time that these two indicators will be equal. It was found that the average time of equalization will be 7.0 years and may be less than 5.0 years in locations where the conventional energy is more expensive than the national average and average annual irradiation is higher than that in the rest of the country. Finally, this work presents how the Brazilian legislation deals with the photovoltaic generators connected to the public distribution network, showing the points for and legal obstacles to the dissemination of GCPS.
18

Análise de um mecanismo de compensação de reativos incorporado aos inversores de um sistema fotovoltaico conectado à rede elétrica / Analysis of a reactive power compensation mechanism incorporated into inverters of a grid-connected photovoltaic system

Ricardo da Silva Benedito 14 November 2014 (has links)
No Brasil, quando uma unidade consumidora (UC) sob regime de microgeração ou de minigeração distribuída tem parte ou a totalidade da sua demanda por potência ativa suprida pela planta geradora, mas sua demanda por potência reativa é atendida exclusivamente pela rede elétrica, verifica-se uma aparente deterioração do fator de potência dessa UC, sob a ótica da concessionária. Esse efeito decorre do fato de que o fator de potência, de acordo com a regulamentação vigente, é determinado apenas a partir das medições dos fluxos de potência ativa e reativa trocados entre a UC e a rede elétrica e não também entre a planta geradora e UC. Para consumidores do Grupo A (tensão de fornecimento igual ou superior a 2,3 kV) nessa situação, de acordo com o perfil da carga, pode haver cobrança por excedentes de reativos, constituindo-se assim uma barreira. Especificamente no caso de sistemas fotovoltaicos conectados à rede, existe a possibilidade de se utilizar os próprios inversores c.c.-c.a para suprir a demanda de reativos da UC e, dessa forma, minimizar o problema apresentado. Com o objetivo de se avaliar essa alternativa no contexto brasileiro, tendo-se em vista condições reais de operação e os limites normativos de injeção de potência reativa para inversores de sistemas fotovoltaicos, foi realizado um estudo de caso de uma planta fotovoltaica instalada no telhado do prédio da Administração do Instituto de Energia e Ambiente da Universidade de São Paulo. O estudo mostrou que a compensação realizada por meio do inversor selecionado evitou a cobrança de excedentes de reativos sem afetar de forma significativa a produtividade do sistema fotovoltaico. Do ponto de vista elétrico, verificou-se que a injeção de reativos pelo inversor não provocou variações significativas de tensão no ponto de acoplamento ou no alimentador e, ainda, se verificou considerável liberação de capacidade do sistema supridor da concessionária. Dessa forma, a análise dos resultados indica uma tendência a se considerar a compensação de reativos proporcionada pelo próprio inversor a opção mais viável para se lidar com os excedentes de reativos, comparativamente a métodos convencionais de compensação ou à situação em que nenhuma ação compensatória seja implementada. / In Brazil, when a consumer unit (CU) under a distributed microgeneration or minigeneration scheme has part or all of its demand for active power supplied by the generating plant, but its demand for reactive power is served exclusively by the grid, the power factor of this CU appears deteriorated, from the perspective of the utility. This effect is due to the fact the power factor, according to the current regulations, is determined only from measurements of the flows of active and reactive power exchanged between the UC and the grid and not also between the generating plant and UC. Users of group A (supply voltage equal to or greater than 2.3 kV) in this situation, according to the CU load profile, may be charged due the reactive power excess, thus constituting a barrier. Specifically in the case of grid-connected photovoltaic systems, there is the possibility of using the d.c.- a.c. inverters to suply the CU reactive power demand and, thus, minimizing the presented problem. In order to evaluate this alternative in the Brazilian context, keeping in view real operating conditions and regulatory limits for the reactive power injection for photovoltaic inverters, we conducted a case study with a photovoltaic plant installed on the roof of the University of São Paulo Institute for Energy and Environment administration building. The study showed that the compensation performed by the selected inverter prevented the reactive power excess charging without affecting significantly the photovoltaic system productivity. From an electrical point of view, it was found that the injection of reactive power by the inverter did not cause significant voltage variations at the coupling point or at the transformer and, additionally, there was a significant release in the utility suply system capacity. Thus, the analysis results indicates a tendency to consider the compensation provided by the inverter itself the most viable option for dealing with the surplus of reactive power compared to conventional compensation methods or to the situation in which no compensatory action is implemented.
19

Modelagem de cargas não lineares e rede de energia elétrica para simulação de sistemas fotovoltaicos conectados à rede

Pufal, Ricardo Augusto January 2012 (has links)
Os inversores utilizados no sistema fotovoltaico conectados à rede (SFCR) devem apresentar uma forma de onda senoidal nos seus terminais de saída. Monitoram regularmente a qualidade de energia da rede elétrica aos quais estão conectados, de maneira a só gerarem energia se a rede estiver com tensão. Dependendo do inversor, da potência que ele está desenvolvendo em relação à sua potência nominal, da rede ao qual está conectado e das características da carga que ele alimentará, podem ser apresentadas distorções na rede de energia em relação à forma de onda senoidal pura, tanto a nível de tensão como a nível de corrente elétrica. Não é incomum os dispositivos que são conectados a redes apresentarem-se como geradores de harmônicos, principalmente os eletrônicos. Estas distorções, conhecidas na literatura como distorções harmônicas, afetam o desempenho dos inversores quando ligados a redes elétricas. Nestas redes, como pode haver distorções significativas. Os parâmetros elétricos que os inversores se baseiam para obter as características da rede a qual estão conectados,devido a estas distorções, podem fazer com que os mesmos se desconectem. O inversor também se desconectará automaticamente da rede ao perceber a ocorrência de variação acentuada da rede ou a falta dela; a esse sistema, dá-se a denominação antiilhamento. Portanto, é de bastante importância que se consiga reproduzir teoricamente o comportamento das cargas e das redes elétricas, nas quais os inversores serão conectados para que seja possível estudá-los quando interligados às diferentes cargas. Entretanto, devido ao inversor ser também um equipamento eletrônico baseado em fonte chaveada para “remontar” a onda senoidal, o mesmo também acaba introduzindo uma deformação tanto na tensão como na corrente da rede elétrica ao qual está conectado, e esta deformação é também significativa em SFCR de grande porte (instalação de geração fotovoltaica com grande número de inversores). Assim, este trabalho visa implementar a modelagem de cargas não lineares (degradadoras da qualidade de energia) para serem aplicadas em simulações de inversores de SFCR, com aplicação especial no parâmetro “cargas” do programa para computadores FVCONECT desenvolvido pelo Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul. / It is known that the inverters used in photovoltaic systems connected to mains power (SFCR), when connected to the power grid, should provide a sinusoidal waveform at its output terminals. The photovoltaic systems inverters regularly monitor the power grid quality they are connected to, so they generate power only if the grid of the Concessionaire or external power grid presents voltage. Depending on the inverter, on the power that it develops over the same rated power, on the power grid it is connected to and on the characteristics of the load that it also feeds, it is possible to occur certain distortions on the power grid compared to pure sine waveform, in terms of voltage or even in terms of electric current. The devices connected to grid commonly present themselves as harmonic generators. The loads cause large distortions in the power grid causing disorders occur both voltage and current in a distribution line or power circuit. These distortions, commented in the literature as harmonic distortions, greatly affect the inverters performance when connected to power grids. On these grids, as it is possible to identify significant distortions, the parameters for pairing the power grid, in which the inverters are based, can turn them into disconnection. The inverter automatically disconnects from the grid if for some reason the grid stops powering the power grid - such system is called anti-islanding. Therefore, it is important to theoretically reproduce the behavior of power grids which the inverters are connected to, in order to study them. However, due to the fact that the inverter is also a switched source-based electronic equipment to "reassemble" the sine wave, it provides a deformation not only on the voltage but also on the power grid current which it is connected to, being this deformation also significant in large SFCR (photovoltaic generation facility with large numbers of inverters). In this sense, the present work aims to implement the modeling of nonlinear loads (which can degrade the power quality) in SFCR inverters simulations, based on the special application of loads parameters from the FVCONECT software, developed by the Solar Energy Laboratory, Federal University of Rio Grande do Sul.
20

Degradação induzida pelo potencial em módulos e instalações fotovoltaicas de c-Si / Potential induced degradation on c-Si photovoltaic modules and installations

Pinto Filho, Gilberto Figueiredo 14 November 2017 (has links)
Este trabalho apresenta abordagens para a avaliação do fenômeno da Degradação Induzida pelo Potencial (PID do inglês Potential Induced Degradation) em módulos e instalações fotovoltaicas de c-Si. Nos ensaios em laboratório, a IEC TS 62804-1:2015 foi aplicada e ações adicionais são sugeridas como forma de adaptação da especificação técnica para o acompanhamento da degradação durante o ensaio e para melhor indicar a propensão do equipamento a se recuperar das consequências da aparição de PID. Nos ensaios em campo, avaliou-se a solução convencional do mercado de reverter a degradação através de circuitos anti-PID, além de apresentar a aplicação de técnicas de detecção do fenômeno em sistemas operacionais. A abordagem teórica e os resultados práticos mostram que o procedimento de aferição de tensões individuais de operação é um método útil para detectar PID. Os estudos de caso apresentados indicam que esta metodologia é eficaz inclusive na detecção precoce do fenômeno para diferentes topologias de células fotovoltaicas de c-Si. / This work presents approaches to assess the Potential Induced Degradation (PID) on c-Si photovoltaic modules and installations. The IEC TS 62804-1:2015 was applied to the laboratory tests and some additional actions are suggested. The adaptation of the technical specification aims to monitor the degradation rates during the tests and also to consider the capacity of the photovoltaic modules to recover from the degradation. In the field detection methodologies are presented and anti-PID circuits were also tested. The theoretical approach reveals that individual voltage measurements are useful to detect PID even in its early stage, as can be seen on the case studies presented.