• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 10
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 48
  • 48
  • 23
  • 21
  • 17
  • 14
  • 12
  • 12
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

In-vitro-Vergleich zweier verschiedener Techniken zur Revision von Wurzelkanalfüllungen in gekrümmten Wurzelkanälen - Eine Micro-Computertomografie-Studie / Comparison of hand and rotary instrumentation for removing gutta-percha from previously treated curved root canals – a micro-computed tomography study

Kupis, Jolantha 15 January 2013 (has links)
No description available.
42

Desenvolvimento de um método computacional para avaliação da conformidade de cones obturadores acessórios / A computerized routine of digital image analysis as an efficient approach to evaluate the standardization quality of filling cones

Cristiane Audi 12 February 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esse trabalho teve como objetivo avaliar a qualidade de padronização dos cones acessórios Fine Medium (FM), Medium (M) e Medium Large (ML) de cinco diferentes marcas comerciais de cones de guta-percha e de uma marca de cone Resilon, através do desenvolvimento de um método automático de processamento e análise digital de imagens. Para tal, 21 cones de cada conicidade e marca comercial foram digitalizados em um scanner com 1200 DPI, o que implica em uma precisão de 0.021 mm, e uma rotina de processamento digital das imagens foi desenvolvida para obter medições automáticas dos seguintes parâmetros: diâmetro da ponta (D0), diâmetro a 3 mm da ponta (D3), diâmetro a 16 mm da ponta (D16), comprimento (L) e conicidade (C). As medidas encontradas foram submetidas a análises estatísticas e comparações entre os grupos das médias de cada parâmetro avaliado. As especificações ANSI/ADA números 57 e 78 foram empregadas como referências para a análise da estandardização dos cones testados. De posse dos resultados, foi possível concluir que existe uma ineficaz padronização dos cones obturadores, os quais apresentaram grandes variações entre as diversas marcas testadas e dentro de uma mesma marca. O método desenvolvido para medição dos parâmetros de controle dos cones se mostrou bastante eficaz, gerando resultados confiáveis. / The present study aimed to evaluate the standardization quality of the accessory gutta-percha cones Fine Medium (FM), Medium (M) and Medium Large (ML) of five different commercial brands of gutta-percha cones and a brand of Resilon cone, through the development of an automated method of digital image processing and analysis sequence. Hence, 21 cones of each conicity and commercial brand were digitalized with a scanner with 1200 DPI, which implicates on a precision of 0,021mm and a sequence of digital image processing were developed to obtain automatic measures of the following parameters: D0, D3, D16, length (L) and conicity (C). The measures found were submitted to statistical analysis and comparisons among the groups of the means of each parameter evaluated. Numbers 57 and 78 ANSI/ADA specifications were used as references to the standardization analysis of the tested cones. Based on the results obtained it was possible to conclude that there is an inefficient standardization of obturating cones, which presented large variations among the different tested brands and in a single brand also. The method developed to measure the parameters of the obturating cones control group was very efficient, producing reliable results.
43

Biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) / Biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta)

Felipe Gonçalves Belladonna 04 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho foi avaliar a biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) em tecido subcutâneo de camundongos. A guta-percha convencional foi utilizada como referência para comparação. Para isso, foram utilizados 30 camundongos, os quais foram distribuídos aleatoriamente em dois grupos (Bio-Gutta e guta-percha convencional). Os materiais avaliados foram implantados na região dorsal dos camundongos. Após 7, 21 e 63 dias, os animais foram sacrificados e 5 amostras por grupo por tempo experimental foram obtidas. As amostras histológicas foram seccionadas em 5 m de espessura e coradas convencionalmente com hematoxilina e eosina. Um escore de I-IV foi utilizado para graduar a reação inflamatória. O teste U de Mann-Whitney com correção de Bonferroni foi utilizado para análise estatística (p < 0,05). Os resultados mostraram que, após 7 dias, a Bio-Gutta induziu uma reação tecidual de leve a moderada (II) e a guta-percha convencional apresentou uma resposta inflamatória de moderada a intensa (III). Após 21 dias, a Bio-Gutta induziu uma leve reação tecidual (I), enquanto que a guta-percha convencional ainda apresentava uma resposta inflamatória moderada (III). Uma reação tecidual de leve a ausente (I) foi observada na Bio-Gutta após 63 dias, ao passo que na guta-percha convencional observou-se uma resposta inflamatória de leve a moderada (II). Houve diferença significativa na mediana do grau de inflamação entre os grupos em cada tempo experimental (p = 0,005, aos 7 dias; p = 0,011, aos 21 dias; e p = 0,003, aos 63 dias). Concluiu-se então que a Bio-Gutta foi mais biocompatível que a guta-percha convencional em tecido subcutâneo de camundongos apresentando uma boa resposta tecidual. / The purpose of this study was to evaluate the biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta) in connective tissue of mice. Conventional gutta-percha was used as reference for comparison. Thirty mice were used in this study and they were randomly assigned into two groups (Bio-Gutta and conventional gutta-percha). The tested materials were implanted in the dorsal region of mice. After 7, 21 and 63 days, animals were sacrificed and 5 samples per group per time-point were obtained. Histologic samples were sectioned in 5 m thickness and stained with conventional hematoxylin and eosin. A grade from I-IV was used to graduate the inflammatory reaction. Bonferroni-corrected Mann-Whitney U test was used for statistical analysis (p < 0,05). The results showed that after 7 days Bio-Gutta induced a slight to moderate tissue reaction (II) and conventional gutta-percha presented a moderate to intense inflammatory response (III). After 21 days, Bio-Gutta presented a slight tissue reaction (I), while conventional gutta-percha still showed a moderate inflammatory response (III). A slight to absent tissue reaction (I) was observed in Bio-Gutta after 63 days, whereas conventional gutta-percha showed a slight to moderate inflammatory response (II). There was a significant difference in the median degree of inflammation between the groups at each time-point (p = 0,005, at 7 days; p = 0,011, at 21 days; and p = 0,003, at 63 days). It was concluded that Bio-Gutta was more biocompatible than conventional gutta-percha in subcutaneous tissue of mice showing a good tissue response.
44

Desenvolvimento de um método computacional para avaliação da conformidade de cones obturadores acessórios / A computerized routine of digital image analysis as an efficient approach to evaluate the standardization quality of filling cones

Cristiane Audi 12 February 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esse trabalho teve como objetivo avaliar a qualidade de padronização dos cones acessórios Fine Medium (FM), Medium (M) e Medium Large (ML) de cinco diferentes marcas comerciais de cones de guta-percha e de uma marca de cone Resilon, através do desenvolvimento de um método automático de processamento e análise digital de imagens. Para tal, 21 cones de cada conicidade e marca comercial foram digitalizados em um scanner com 1200 DPI, o que implica em uma precisão de 0.021 mm, e uma rotina de processamento digital das imagens foi desenvolvida para obter medições automáticas dos seguintes parâmetros: diâmetro da ponta (D0), diâmetro a 3 mm da ponta (D3), diâmetro a 16 mm da ponta (D16), comprimento (L) e conicidade (C). As medidas encontradas foram submetidas a análises estatísticas e comparações entre os grupos das médias de cada parâmetro avaliado. As especificações ANSI/ADA números 57 e 78 foram empregadas como referências para a análise da estandardização dos cones testados. De posse dos resultados, foi possível concluir que existe uma ineficaz padronização dos cones obturadores, os quais apresentaram grandes variações entre as diversas marcas testadas e dentro de uma mesma marca. O método desenvolvido para medição dos parâmetros de controle dos cones se mostrou bastante eficaz, gerando resultados confiáveis. / The present study aimed to evaluate the standardization quality of the accessory gutta-percha cones Fine Medium (FM), Medium (M) and Medium Large (ML) of five different commercial brands of gutta-percha cones and a brand of Resilon cone, through the development of an automated method of digital image processing and analysis sequence. Hence, 21 cones of each conicity and commercial brand were digitalized with a scanner with 1200 DPI, which implicates on a precision of 0,021mm and a sequence of digital image processing were developed to obtain automatic measures of the following parameters: D0, D3, D16, length (L) and conicity (C). The measures found were submitted to statistical analysis and comparisons among the groups of the means of each parameter evaluated. Numbers 57 and 78 ANSI/ADA specifications were used as references to the standardization analysis of the tested cones. Based on the results obtained it was possible to conclude that there is an inefficient standardization of obturating cones, which presented large variations among the different tested brands and in a single brand also. The method developed to measure the parameters of the obturating cones control group was very efficient, producing reliable results.
45

Biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) / Biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta)

Felipe Gonçalves Belladonna 04 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho foi avaliar a biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) em tecido subcutâneo de camundongos. A guta-percha convencional foi utilizada como referência para comparação. Para isso, foram utilizados 30 camundongos, os quais foram distribuídos aleatoriamente em dois grupos (Bio-Gutta e guta-percha convencional). Os materiais avaliados foram implantados na região dorsal dos camundongos. Após 7, 21 e 63 dias, os animais foram sacrificados e 5 amostras por grupo por tempo experimental foram obtidas. As amostras histológicas foram seccionadas em 5 m de espessura e coradas convencionalmente com hematoxilina e eosina. Um escore de I-IV foi utilizado para graduar a reação inflamatória. O teste U de Mann-Whitney com correção de Bonferroni foi utilizado para análise estatística (p < 0,05). Os resultados mostraram que, após 7 dias, a Bio-Gutta induziu uma reação tecidual de leve a moderada (II) e a guta-percha convencional apresentou uma resposta inflamatória de moderada a intensa (III). Após 21 dias, a Bio-Gutta induziu uma leve reação tecidual (I), enquanto que a guta-percha convencional ainda apresentava uma resposta inflamatória moderada (III). Uma reação tecidual de leve a ausente (I) foi observada na Bio-Gutta após 63 dias, ao passo que na guta-percha convencional observou-se uma resposta inflamatória de leve a moderada (II). Houve diferença significativa na mediana do grau de inflamação entre os grupos em cada tempo experimental (p = 0,005, aos 7 dias; p = 0,011, aos 21 dias; e p = 0,003, aos 63 dias). Concluiu-se então que a Bio-Gutta foi mais biocompatível que a guta-percha convencional em tecido subcutâneo de camundongos apresentando uma boa resposta tecidual. / The purpose of this study was to evaluate the biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta) in connective tissue of mice. Conventional gutta-percha was used as reference for comparison. Thirty mice were used in this study and they were randomly assigned into two groups (Bio-Gutta and conventional gutta-percha). The tested materials were implanted in the dorsal region of mice. After 7, 21 and 63 days, animals were sacrificed and 5 samples per group per time-point were obtained. Histologic samples were sectioned in 5 m thickness and stained with conventional hematoxylin and eosin. A grade from I-IV was used to graduate the inflammatory reaction. Bonferroni-corrected Mann-Whitney U test was used for statistical analysis (p < 0,05). The results showed that after 7 days Bio-Gutta induced a slight to moderate tissue reaction (II) and conventional gutta-percha presented a moderate to intense inflammatory response (III). After 21 days, Bio-Gutta presented a slight tissue reaction (I), while conventional gutta-percha still showed a moderate inflammatory response (III). A slight to absent tissue reaction (I) was observed in Bio-Gutta after 63 days, whereas conventional gutta-percha showed a slight to moderate inflammatory response (II). There was a significant difference in the median degree of inflammation between the groups at each time-point (p = 0,005, at 7 days; p = 0,011, at 21 days; and p = 0,003, at 63 days). It was concluded that Bio-Gutta was more biocompatible than conventional gutta-percha in subcutaneous tissue of mice showing a good tissue response.
46

Evaluación de la eficacia disolvente de una sustancia experimental a base de Aceite esencial de Myrciaria dubia en la desobturación de conductos radiculares / Evaluation of the solvent efficacy of an experimental substance based on Myrciaria dubia essential oil in duct desobturation

Wiess Laurencio, Fabrizzio Alfredo 04 April 2020 (has links)
Objetivo: Evaluar la eficacia disolvente de una sustancia experimental a base de Aceite esencial de Myrciaria dubia en la desobturación de conductos radiculares. Materiales y métodos: Se utilizaron 60 tubos de PLA (ácido poliláctico)que fueron divididos en 5 grupos de 12 especímenes. Estos se rellenaron con un material de restauración temporal (coltosol) el primer tercio y el tercio medio con gutapercha. Se añadió un total de 0,1 ml de disolvente dependiendo del grupo de estudio (Agua destilada,camu camu, xilol,aceite de cascara de naranja y de eucalipto) a la parte superior de los tubos de PLA. Después de 5 minutos, se utilizó la máquina Instron 5566 (Instron, Buckinghamshire, UK) se movió hacia abajo a través de gutapercha con una velocidad de cabecera de 5 mm / min a una profundidad de 5 mm min. La carga(fuerza) utilizada para penetrar el separador en la profundidad de 5 mm se registró en Newton. Para el análisis se realizará la prueba de kruskal Wallis para comparar la medida fuerza de penetración según el tipo de solvente, posterior a comprobarse los supuestos estadísticos. Resultados: Se encontraron diferencias estadísticamente significativas al comparar todos los solventes (p= 0.001), obteniendo 14.02N para la sustancia experimental. Los resultados de la profundidad de disolución superficial y la fuerza utilizada para penetrar el esparcidor a 5 mm revelaron que el Aceite de Myrciaria Dubia ( Camu Camu) fue significativamente el mejor solvente para ablandar la gutapercha (P <0.05), seguido del xilol y el aceite de cascara de naranja, mientras que el disolvente con menos efectividad fue el aceite de eucalipto. Conclusiones: El aceite esencial de Myrciaria Dubia presento mayor poder reblandecedor que las demás soluciones en estudio. / Objective: To evaluate the solvent efficacy of an experimental substance based on Myrciaria dubia essential oil in the desobturation of root canals. Materials and methods: 60 PLA (polylactic acid) tubes were used, which were divided into 5 groups of 12 specimens. These were filled with a temporary restoration material (coltosol) the first third and the middle third with gutta-percha. A total of 0.1 ml of solvent was added depending on the study group (distilled water, camu camu, xylol, oil of orange peel and eucalyptus) to the top of the PLA tubes. After 5 minutes, the Instron 5566 machine (Instron, Buckinghamshire, UK) was used and moved down through gutta-percha with a head speed of 5 mm / min at a depth of 5 mm min. The load (force) used to penetrate the separator to the depth of 5 mm was recorded in Newton. For the analysis, the kruskal Wallis test will be carried out to compare the penetration force measure according to the type of solvent, after checking the statistical assumptions. Results: Statistically significant differences were found when comparing all solvents (p = 0.001), obtaining 14.02N for the experimental substance. The results of the surface dissolution depth and the force used to penetrate the spreader to 5 mm revealed that Myrciaria Dubia Oil (Camu Camu) was significantly the best solvent to soften gutta-percha (P <0.05), followed by xylol and orange peel oil, while the least effective solvent was eucalyptus oil. Conclusions: The essential oil of Myrciaria Dubia presented greater softening power than the other solutions under study. / Tesis
47

"Influência da técnica de desobturação e do limite de obturação na extrusão apical" / Apical extrusion: influence on gutta-percha removal technique and root filling limit.

Esteves, Cristiane Linge Exposito 24 November 2004 (has links)
O controle da extrusão apical durante a reintervenção endodôntica é essencial para o sucesso do novo tratamento. Nesse contexto, o presente estudo teve como objetivo comparar a quantidade de material sólido extruído na desobturação de canais radiculares variando-se a técnica de esvaziamento e o limite de obturação. Foram utilizados 40 incisivos inferiores previamente tratados divididos em dois grupos de acordo com o limite de obturação estabelecido. Cada grupo foi subdividido em dois subgrupos levando-se em conta a técnica de desobturação empregada; manual (subgrupos A1 e B1) e mecânico-rotatória com limas de Ni-Ti (Quantec LX) (subgrupos A2 e B2). O material sólido extruído foi coletado por meio do sistema de filtração Millipore, levado à secagem em dessecador de sílica e pesado em balança analítica de precisão. Os resultados obtidos foram submetidos a ANOVA para dois fatores de variação sendo em seguida empregado o Teste de Tukey (&#945; = 5%). A técnica de desobturação mecânico-rotatória produziu menor extrusão (0,66mg) que a manual (1,11mg), havendo diferença estatística significante entre elas (p < 0,05). Os canais preenchidos até o vértice radiográfico apresentaram maior quantidade de extrusão (1,38mg) do que os obturados 1 mm aquém do forame (0,39mg), observando-se diferença estatística significante entre eles (p < 0,05). A menor quantidade extrusão foi observada no subgrupo A2 (0,20mg), em que foi empregada a técnica rotatória de desobturação em canais obturados 1mm aquém do forame apical, sendo constatada diferença estatisticamente significante deste subgrupo com os demais (p < 0,05). A extrusão de material sólido durante a desobturação de canais radiculares é influenciado pela técnica empregada e pelo limite apical de obturação. / The apical extrusion control during the endodontic retreatment is essential for the success of the new treatment. The purpose of this study was to compare the quantity of solid apically extruded material during filling removal according the gutta-percha removal technique and root filling limit. Forty mandibular incisors with a single straight canal were selected. The canals were previously endodontically treated and then divided into two groups according the filling level. Each group was subdivided in two groups considering the retreatment technique: stainless steel hand files (subgroups A1 and B1) versus niquel-titanium rotatory instruments (subgroups A2 and B2). The extruded solid material was collected by Millipore filtration system, dried in silica desiccators and weighed in an eletrobalance. The results were analyzed using ANOVA with two variation factors and Tukey Test (&#945; = 5%). The niquel-titanium rotatory instruments produced less extrusion (0,66mg) than the stainless steel hand files (1,11mg), with significant statistical difference between them (p < 0,05). The canals filled until the radiographic apex showed larger amount of extruded material (1,38mg) than those filled 1 mm beyond the foramen (0,39mg). It was observed significant statistical difference between them (p < 0,05). The smaller extruded debris amount was observed in subgroup A2 (0,20mg), in which one the rotary technique was used to remove the gutta-percha of canals filled 1mm beyond the apical foramen. It was verified significant statistical difference of this subgroup with the other ones (p < 0,05). The extrusion of solid material during the gutta-percha removal is influenced by the technique as well as the apical filling limit.
48

"Influência da técnica de desobturação e do limite de obturação na extrusão apical" / Apical extrusion: influence on gutta-percha removal technique and root filling limit.

Cristiane Linge Exposito Esteves 24 November 2004 (has links)
O controle da extrusão apical durante a reintervenção endodôntica é essencial para o sucesso do novo tratamento. Nesse contexto, o presente estudo teve como objetivo comparar a quantidade de material sólido extruído na desobturação de canais radiculares variando-se a técnica de esvaziamento e o limite de obturação. Foram utilizados 40 incisivos inferiores previamente tratados divididos em dois grupos de acordo com o limite de obturação estabelecido. Cada grupo foi subdividido em dois subgrupos levando-se em conta a técnica de desobturação empregada; manual (subgrupos A1 e B1) e mecânico-rotatória com limas de Ni-Ti (Quantec LX) (subgrupos A2 e B2). O material sólido extruído foi coletado por meio do sistema de filtração Millipore, levado à secagem em dessecador de sílica e pesado em balança analítica de precisão. Os resultados obtidos foram submetidos a ANOVA para dois fatores de variação sendo em seguida empregado o Teste de Tukey (&#945; = 5%). A técnica de desobturação mecânico-rotatória produziu menor extrusão (0,66mg) que a manual (1,11mg), havendo diferença estatística significante entre elas (p < 0,05). Os canais preenchidos até o vértice radiográfico apresentaram maior quantidade de extrusão (1,38mg) do que os obturados 1 mm aquém do forame (0,39mg), observando-se diferença estatística significante entre eles (p < 0,05). A menor quantidade extrusão foi observada no subgrupo A2 (0,20mg), em que foi empregada a técnica rotatória de desobturação em canais obturados 1mm aquém do forame apical, sendo constatada diferença estatisticamente significante deste subgrupo com os demais (p < 0,05). A extrusão de material sólido durante a desobturação de canais radiculares é influenciado pela técnica empregada e pelo limite apical de obturação. / The apical extrusion control during the endodontic retreatment is essential for the success of the new treatment. The purpose of this study was to compare the quantity of solid apically extruded material during filling removal according the gutta-percha removal technique and root filling limit. Forty mandibular incisors with a single straight canal were selected. The canals were previously endodontically treated and then divided into two groups according the filling level. Each group was subdivided in two groups considering the retreatment technique: stainless steel hand files (subgroups A1 and B1) versus niquel-titanium rotatory instruments (subgroups A2 and B2). The extruded solid material was collected by Millipore filtration system, dried in silica desiccators and weighed in an eletrobalance. The results were analyzed using ANOVA with two variation factors and Tukey Test (&#945; = 5%). The niquel-titanium rotatory instruments produced less extrusion (0,66mg) than the stainless steel hand files (1,11mg), with significant statistical difference between them (p < 0,05). The canals filled until the radiographic apex showed larger amount of extruded material (1,38mg) than those filled 1 mm beyond the foramen (0,39mg). It was observed significant statistical difference between them (p < 0,05). The smaller extruded debris amount was observed in subgroup A2 (0,20mg), in which one the rotary technique was used to remove the gutta-percha of canals filled 1mm beyond the apical foramen. It was verified significant statistical difference of this subgroup with the other ones (p < 0,05). The extrusion of solid material during the gutta-percha removal is influenced by the technique as well as the apical filling limit.

Page generated in 0.0362 seconds