• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 5
  • Tagged with
  • 21
  • 21
  • 16
  • 16
  • 11
  • 11
  • 10
  • 8
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instruments

Sá, Júnio Pereira de 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
2

Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instruments

Júnio Pereira de Sá 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
3

"Influência da velocidade de rotação e do número de usos no tempo de trabalho e na fratura de instrumentos rotatórios de níquel-titânio" / Influence of rotational speed and simulated clinical use on breakage and instrumentation time of rotary nickel-titanium files

Lauretti, Luis Guilherme Bertoni 05 April 2006 (has links)
Inúmeras são as vantagens da utilização de instrumentos rotatórios de níquel-titânio no preparo químico-cirúrgico, como por exemplo, melhor modelagem dos canais curvos e uma diminuição significativa no tempo de trabalho. Todavia, a maior preocupação no uso desses instrumentos tem sido a sua fratura, principalmente, por sua ocorrência estar ligada a diferentes fatores. O objetivo do presente estudo foi avaliar a influência da velocidade de rotação e do número de usos, no tempo de trabalho e na ocorrência de fraturas de instrumentos de dois sistemas rotatórios de níquel-titânio (K3 e RaCe), em canais simulados com mesmo ângulo de curvatura. Foram avaliados os instrumentos 25/.04 dos dois sistemas nas velocidades de 180, 350, 600 rpm ao instrumentarem 5 mm referentes à curvatura dos canais simulados. Para cada velocidade foram utilizadas limas com 1, 2 e 3 usos. Um contra-ângulo foi adaptado a um dispositivo calibrado para realizar movimentos padronizados de penetração nos canais simulados. Foram mensurados: o tempo necessário para instrumentar a curvatura do canal e a quantidade de fraturas ocorridas. Os resultados obtidos foram submetidos a ANOVA sendo em seguida empregado o teste de Tukey (&#945;=5%). Sob as condições desse experimento, o aumento da velocidade diminuiu o tempo de instrumentação em ambos os sistemas. Os instrumentos RaCe prepararam o canal em menor tempo do que os instrumentos K3 nas velocidades de 350 e 600 rpm (p<0,05), não havendo diferença em 180 rpm (p>0,05). Ocorreu maior número de instrumentos fraturados nas velocidades de 180 e 600 rpm para o sistema RaCe e de 600 rpm para o K3, e nenhuma fratura na velocidade de 350 rpm para ambos. O número de usos não influenciou o tempo de trabalho para nenhum sistema (p>0,05), porém, o número de fraturas aumentou proporcionalmente ao aumento do número de usos, exceto na velocidade de 350 rpm na qual não ocorreram fraturas. Os instrumentos RaCe apresentaram maior índice de fratura para a velocidade de 180 rpm (30%) do que para 600 rpm (13,33%). A velocidade de 350 rpm foi a mais segura para os instrumentos de ambos os sistemas. / Use of nickel-titanium rotary instruments has many advantages like better shaping of curved canals and lower working time. However, instrument fracture has always been a serious concern in root canal treatment because it involves a lot of factors. The aim of this study was to evaluate the influence of rotational speed and number of uses on the preparation time and incidence of fractures of K3 and RaCe instruments, using simulated root canals with the same angle of curvature. Nickel-titanium 25/.04- tapered instruments of both rotary systems were tested at 180, 350 and 600 rpm during shaping of 5 mm curvature’s extent. The files were used 3 times in each rotational speed. A contra-angle electric handpiece was mounted on a machine that was calibrated to deliver a constant penetration movement. Working time and incidence of fractures were measured. The results were analyzed statistically using a one-way analysis of variance with a post-hoc Tukey test (&#945;=5%). Under the conditions of this study, higher rotational speeds reduced preparation time for both rotary systems. RaCe instruments showed lower preparation time than K3 instruments at 350 and 600 rpm (p<0,05). There was no significant difference at 180 rpm (p>0,05). There was a higher incidence of fractures at 180 and 600 rpm for RaCe instruments and at 600 rpm for K3 instruments. No file breakage occurred at 350 rpm for both instruments. Preparation time was not influenced significantly by the frequency that the files were used (p>0,05). Incidence of fractures increased with an increase in the number of file usage, unless at 350 rpm in which none of the files fractured. At 180 rpm, RaCe instruments showed a higher incidence of breakage than at 600 rpm. Rotational speed of 350 rpm was the safest for both kind of instruments tested in this study.
4

Avaliação do preparo biomecânico e da obturação de canais radiculares ovais promovidos pelos sistemas de instrumento único WaveOne, Reciproc e SAF / Evaluation of biomechanical preparation and obturation of oval canals using WaveOne, Reciproc and SAF single-file systems

Versiani, Marco Aurelio 22 March 2012 (has links)
O objetivo deste estudo ex vivo foi avaliar o preparo biomecânico e a obturação de canais radiculares ovais utilizando os sistemas ProTaper, WaveOne, Reciproc e Self-Adjusting File. Com esta finalidade avaliou-se: 1) área, perímetro, circularidade, diâmetro maior, diâmetro menor, área de superfície, volume e SMI após o preparo biomecânico, por meio de microtomografia computadorizada (&mu;TC); 2) percentual volumétrico de espaços vazios após a obturação do canal, por meio de &mu;TC; 3) resistência de união (RU) e tipo de falha ocorrida após teste de push-out; e 4) a interface dentina/material obturador em microscopia eletrônica de varredura (MEV). Cem caninos inferiores humanos foram escaneados no microtomógrafo SkyScan 1174v.2. Após o preparo do terço cervical dos canais, os dentes foram distribuídos em 4 grupos (n=25), de acordo com o sistema usado no preparo biomecânico: ProTaper; WaveOne; Reciproc; Self-Adjusting File (SAF). Após a segunda &mu;TC, 18 espécimes de cada grupo foram redistribuídos em dois grupos (n=9), de acordo com a técnica de obturação: Técnica Modificada da Onda Contínua de Condensação e técnica recomendada pelo fabricante. Os sete espécimes restantes de cada grupo constituíram os grupos controle negativo e positivo. Após a TC dos espécimes obturados, as raízes foram seccionadas transversalmente em fatias de 1 mm de espessura correspondentes às regiões cervical, média e apical. A RU foi avaliada pelo teste de push-out e as falhas após desunião observadas em microscópio digital. Após preparo para MEV, avaliou-se a interface adesiva de forma qualitativa nominal e ordinal pelo estabelecimento e determinação de escores. No conjunto, a análise dos parâmetros avaliados no preparo biomecânico mostraram que as alterações mais significativas ocorreram nos grupos ProTaper e WaveOne. Os resultados no grupo Reciproc ficaram em um nível intermediário, enquanto as menores alterações foram observadas no grupo SAF (ANOVA, p<0,05). Em relação à obturação, a Técnica Modificada da Onda Contínua de Condensação apresentou menor percentual volumétrico de espaços vazios que a técnica recomendada pelo fabricante apenas no terço cervical (Kruskall-Wallis, p<0,05). Após o teste de push-out, a análise das médias indicou RU (MPa) significativamente maior nos espécimes obturados pela técnica do fabricante em comparação com a Técnica Modificada de Onda Contínua de Condensação (teste t para amostras independentes, p<0,05). Em todos os grupos foi verificado maior percentual de falhas adesivas, com predominância de falhas mistas na técnica do fabricante e de falhas adesiva na dentina na Técnica Modificada de Onda Contínua de Condensação. Em MEV, não houve tags na maioria dos espécimes obturados pela Técnica Modificada da Onda Contínua de Condensação e quando presentes, eram pequenos e irregularmente distribuídos. Nos espécimes obturados pela técnica recomendada pelo fabricante observou-se formação de tags longos e bem distribuídos, principalmente no terço apical (teste de Friedman, p<0,05). Concluiu-se que todos os sistemas resultaram em alterações nos parâmetros bidimensionais e tridimensionais do canal após o preparo biomecânico; a técnica recomendada pelo fabricante resultou em maior volume de espaços vazios no terço cervical e maior RU do material obturador do que a Técnica Modificada de Onda Contínua de Condensação. Obs: tese completa no site: https://rapidshare.com/files/963588082/Tese_Prof._Dr._Marco_Versiani_FORP_USP_2012.pdf (na pagina que abrir, clicar no botao \"download\"). / The purpose of this ex vivo study was to evaluate the biomechanical preparation and obturation of root canals using ProTaper, WaveOne, Reciproc and Self-Adjusting File systems. It was evaluated: 1) area, perimeter, roundness, major diameter, minor diameter, surface area, volume and SMI after biomechanical preparation, using microcomputed tomography (&mu;TC), 2) percentage volume of voids in the obturation material by means of &mu;TC, 3) bond strength (BS) and type of failure after the pushout test, and 4) the analysis of the interface dentin / filling material using scanning electron microscopy (SEM). One-hundred human mandibular canines were scanned in the SkyScan 1174v.2 device. After preparing the coronal third of the canals, the teeth were divided into 4 groups (n=25), according to the biomechanical preparation system used: ProTaper, WaveOne, Reciproc, and Self-Adjusting File (SAF). After the second TC, eigthteen specimens of each group were assigned to two groups (n=9), according to the obturation technique: the Modified Continuous Wave of Condensation Technique and the technique recommended by the manufacturer. The remaining seven specimens of each group were used as negative and positive controls. After scanning, the obturated specimens were sectioned perpendicularly to its long axis into 1-mm slice thickness of the coronal, middle and apical thirds. The bond strength (BS) was performed by the push-out test and, after dislodgments, the failures were observed in a digital microscope. The specimens were processed for SEM analysis to observe bonding interface formation and resin tag density using a four-step scale method. Overall, the analysis of the biomechanical parameters showed that the most significant changes in the root canal occurred in the ProTaper group and WaveOne groups. Reciproc results were in an intermediate level and smaller changes were observed in the SAF group (ANOVA, p<0.05). In the coronal third, the Modified Continuous Wave of Condensation Technique showed a lower percentage volume of voids than the technique recommended by the manufacturer (Kruskal-Wallis test, p<0.05). After the push-out test, the analysis indicated the mean BS (MPa) was significantly higher in specimens filled by the manufacturer\'s technical than the Modified Continuous Wave of Condensation Technique (t test for independent samples, p<0.05). The adhesive failures were frequent in all groups. The Modified Continuous Wave of Condensation Technique showed the highest percentage of adhesive failure in dentin while in the technique recommended by the manufacturer, mixed failure was predominant. Overall, in SEM analysis, no tags were observed in most of the specimens filled by the Modified Continuous Wave of Condensation Technique. When present, they were small and irregularly distributed. The specimens filled by the technique recommended by the manufacturer showed long and well-distributed tags, especially in the apical third (Friedman test, p<0.05). It was concluded that all systems promoted root canal changes after the biomechanical preparation, the obturation technique recommended by the manufacturer resulted in a higher volume of voids in the coronal third and BS of the Modified Continuous Wave of Condensation Technique group.
5

Avaliação do preparo biomecânico e da obturação de canais radiculares ovais promovidos pelos sistemas de instrumento único WaveOne, Reciproc e SAF / Evaluation of biomechanical preparation and obturation of oval canals using WaveOne, Reciproc and SAF single-file systems

Marco Aurelio Versiani 22 March 2012 (has links)
O objetivo deste estudo ex vivo foi avaliar o preparo biomecânico e a obturação de canais radiculares ovais utilizando os sistemas ProTaper, WaveOne, Reciproc e Self-Adjusting File. Com esta finalidade avaliou-se: 1) área, perímetro, circularidade, diâmetro maior, diâmetro menor, área de superfície, volume e SMI após o preparo biomecânico, por meio de microtomografia computadorizada (&mu;TC); 2) percentual volumétrico de espaços vazios após a obturação do canal, por meio de &mu;TC; 3) resistência de união (RU) e tipo de falha ocorrida após teste de push-out; e 4) a interface dentina/material obturador em microscopia eletrônica de varredura (MEV). Cem caninos inferiores humanos foram escaneados no microtomógrafo SkyScan 1174v.2. Após o preparo do terço cervical dos canais, os dentes foram distribuídos em 4 grupos (n=25), de acordo com o sistema usado no preparo biomecânico: ProTaper; WaveOne; Reciproc; Self-Adjusting File (SAF). Após a segunda &mu;TC, 18 espécimes de cada grupo foram redistribuídos em dois grupos (n=9), de acordo com a técnica de obturação: Técnica Modificada da Onda Contínua de Condensação e técnica recomendada pelo fabricante. Os sete espécimes restantes de cada grupo constituíram os grupos controle negativo e positivo. Após a TC dos espécimes obturados, as raízes foram seccionadas transversalmente em fatias de 1 mm de espessura correspondentes às regiões cervical, média e apical. A RU foi avaliada pelo teste de push-out e as falhas após desunião observadas em microscópio digital. Após preparo para MEV, avaliou-se a interface adesiva de forma qualitativa nominal e ordinal pelo estabelecimento e determinação de escores. No conjunto, a análise dos parâmetros avaliados no preparo biomecânico mostraram que as alterações mais significativas ocorreram nos grupos ProTaper e WaveOne. Os resultados no grupo Reciproc ficaram em um nível intermediário, enquanto as menores alterações foram observadas no grupo SAF (ANOVA, p<0,05). Em relação à obturação, a Técnica Modificada da Onda Contínua de Condensação apresentou menor percentual volumétrico de espaços vazios que a técnica recomendada pelo fabricante apenas no terço cervical (Kruskall-Wallis, p<0,05). Após o teste de push-out, a análise das médias indicou RU (MPa) significativamente maior nos espécimes obturados pela técnica do fabricante em comparação com a Técnica Modificada de Onda Contínua de Condensação (teste t para amostras independentes, p<0,05). Em todos os grupos foi verificado maior percentual de falhas adesivas, com predominância de falhas mistas na técnica do fabricante e de falhas adesiva na dentina na Técnica Modificada de Onda Contínua de Condensação. Em MEV, não houve tags na maioria dos espécimes obturados pela Técnica Modificada da Onda Contínua de Condensação e quando presentes, eram pequenos e irregularmente distribuídos. Nos espécimes obturados pela técnica recomendada pelo fabricante observou-se formação de tags longos e bem distribuídos, principalmente no terço apical (teste de Friedman, p<0,05). Concluiu-se que todos os sistemas resultaram em alterações nos parâmetros bidimensionais e tridimensionais do canal após o preparo biomecânico; a técnica recomendada pelo fabricante resultou em maior volume de espaços vazios no terço cervical e maior RU do material obturador do que a Técnica Modificada de Onda Contínua de Condensação. Obs: tese completa no site: https://rapidshare.com/files/963588082/Tese_Prof._Dr._Marco_Versiani_FORP_USP_2012.pdf (na pagina que abrir, clicar no botao \"download\"). / The purpose of this ex vivo study was to evaluate the biomechanical preparation and obturation of root canals using ProTaper, WaveOne, Reciproc and Self-Adjusting File systems. It was evaluated: 1) area, perimeter, roundness, major diameter, minor diameter, surface area, volume and SMI after biomechanical preparation, using microcomputed tomography (&mu;TC), 2) percentage volume of voids in the obturation material by means of &mu;TC, 3) bond strength (BS) and type of failure after the pushout test, and 4) the analysis of the interface dentin / filling material using scanning electron microscopy (SEM). One-hundred human mandibular canines were scanned in the SkyScan 1174v.2 device. After preparing the coronal third of the canals, the teeth were divided into 4 groups (n=25), according to the biomechanical preparation system used: ProTaper, WaveOne, Reciproc, and Self-Adjusting File (SAF). After the second TC, eigthteen specimens of each group were assigned to two groups (n=9), according to the obturation technique: the Modified Continuous Wave of Condensation Technique and the technique recommended by the manufacturer. The remaining seven specimens of each group were used as negative and positive controls. After scanning, the obturated specimens were sectioned perpendicularly to its long axis into 1-mm slice thickness of the coronal, middle and apical thirds. The bond strength (BS) was performed by the push-out test and, after dislodgments, the failures were observed in a digital microscope. The specimens were processed for SEM analysis to observe bonding interface formation and resin tag density using a four-step scale method. Overall, the analysis of the biomechanical parameters showed that the most significant changes in the root canal occurred in the ProTaper group and WaveOne groups. Reciproc results were in an intermediate level and smaller changes were observed in the SAF group (ANOVA, p<0.05). In the coronal third, the Modified Continuous Wave of Condensation Technique showed a lower percentage volume of voids than the technique recommended by the manufacturer (Kruskal-Wallis test, p<0.05). After the push-out test, the analysis indicated the mean BS (MPa) was significantly higher in specimens filled by the manufacturer\'s technical than the Modified Continuous Wave of Condensation Technique (t test for independent samples, p<0.05). The adhesive failures were frequent in all groups. The Modified Continuous Wave of Condensation Technique showed the highest percentage of adhesive failure in dentin while in the technique recommended by the manufacturer, mixed failure was predominant. Overall, in SEM analysis, no tags were observed in most of the specimens filled by the Modified Continuous Wave of Condensation Technique. When present, they were small and irregularly distributed. The specimens filled by the technique recommended by the manufacturer showed long and well-distributed tags, especially in the apical third (Friedman test, p<0.05). It was concluded that all systems promoted root canal changes after the biomechanical preparation, the obturation technique recommended by the manufacturer resulted in a higher volume of voids in the coronal third and BS of the Modified Continuous Wave of Condensation Technique group.
6

"Influência da velocidade de rotação e do número de usos no tempo de trabalho e na fratura de instrumentos rotatórios de níquel-titânio" / Influence of rotational speed and simulated clinical use on breakage and instrumentation time of rotary nickel-titanium files

Luis Guilherme Bertoni Lauretti 05 April 2006 (has links)
Inúmeras são as vantagens da utilização de instrumentos rotatórios de níquel-titânio no preparo químico-cirúrgico, como por exemplo, melhor modelagem dos canais curvos e uma diminuição significativa no tempo de trabalho. Todavia, a maior preocupação no uso desses instrumentos tem sido a sua fratura, principalmente, por sua ocorrência estar ligada a diferentes fatores. O objetivo do presente estudo foi avaliar a influência da velocidade de rotação e do número de usos, no tempo de trabalho e na ocorrência de fraturas de instrumentos de dois sistemas rotatórios de níquel-titânio (K3 e RaCe), em canais simulados com mesmo ângulo de curvatura. Foram avaliados os instrumentos 25/.04 dos dois sistemas nas velocidades de 180, 350, 600 rpm ao instrumentarem 5 mm referentes à curvatura dos canais simulados. Para cada velocidade foram utilizadas limas com 1, 2 e 3 usos. Um contra-ângulo foi adaptado a um dispositivo calibrado para realizar movimentos padronizados de penetração nos canais simulados. Foram mensurados: o tempo necessário para instrumentar a curvatura do canal e a quantidade de fraturas ocorridas. Os resultados obtidos foram submetidos a ANOVA sendo em seguida empregado o teste de Tukey (&#945;=5%). Sob as condições desse experimento, o aumento da velocidade diminuiu o tempo de instrumentação em ambos os sistemas. Os instrumentos RaCe prepararam o canal em menor tempo do que os instrumentos K3 nas velocidades de 350 e 600 rpm (p<0,05), não havendo diferença em 180 rpm (p>0,05). Ocorreu maior número de instrumentos fraturados nas velocidades de 180 e 600 rpm para o sistema RaCe e de 600 rpm para o K3, e nenhuma fratura na velocidade de 350 rpm para ambos. O número de usos não influenciou o tempo de trabalho para nenhum sistema (p>0,05), porém, o número de fraturas aumentou proporcionalmente ao aumento do número de usos, exceto na velocidade de 350 rpm na qual não ocorreram fraturas. Os instrumentos RaCe apresentaram maior índice de fratura para a velocidade de 180 rpm (30%) do que para 600 rpm (13,33%). A velocidade de 350 rpm foi a mais segura para os instrumentos de ambos os sistemas. / Use of nickel-titanium rotary instruments has many advantages like better shaping of curved canals and lower working time. However, instrument fracture has always been a serious concern in root canal treatment because it involves a lot of factors. The aim of this study was to evaluate the influence of rotational speed and number of uses on the preparation time and incidence of fractures of K3 and RaCe instruments, using simulated root canals with the same angle of curvature. Nickel-titanium 25/.04- tapered instruments of both rotary systems were tested at 180, 350 and 600 rpm during shaping of 5 mm curvature’s extent. The files were used 3 times in each rotational speed. A contra-angle electric handpiece was mounted on a machine that was calibrated to deliver a constant penetration movement. Working time and incidence of fractures were measured. The results were analyzed statistically using a one-way analysis of variance with a post-hoc Tukey test (&#945;=5%). Under the conditions of this study, higher rotational speeds reduced preparation time for both rotary systems. RaCe instruments showed lower preparation time than K3 instruments at 350 and 600 rpm (p<0,05). There was no significant difference at 180 rpm (p>0,05). There was a higher incidence of fractures at 180 and 600 rpm for RaCe instruments and at 600 rpm for K3 instruments. No file breakage occurred at 350 rpm for both instruments. Preparation time was not influenced significantly by the frequency that the files were used (p>0,05). Incidence of fractures increased with an increase in the number of file usage, unless at 350 rpm in which none of the files fractured. At 180 rpm, RaCe instruments showed a higher incidence of breakage than at 600 rpm. Rotational speed of 350 rpm was the safest for both kind of instruments tested in this study.
7

Avaliação das características superficiais de instrumentos rotatórios de NiTi antes e após o uso / Evaluation of the superficial characteristics of NiTi rotary instruments before and after they were used

Werington Borges Arantes 08 October 2010 (has links)
Objetivos: Avaliaram-se, por meio de MEV, instrumentos endodônticos do sistema rotatório Ni-Ti, antes e após o uso, considerando limpeza defeitos e deformações. Método: Vinte instrumentos, das marcas Twisted File, BioRaCe, Mtwo e EndoWave foram fotografados com aumento de 190 vezes quanto à presença de sujidade. As limas foram lavadas e novamente fotografadas para visualizar defeitos tendo como critérios a presença ou não de borda irregular, ranhura, microcavidade e rebarba. Realizou-se preparo dos canais radiculares simulados, nova limpeza e análise microscópica dos instrumentos após cinco usos. Após análise em MEV e de posse dos escores dos avaliadores, os dados foram submetidos à análise estatística utilizando o Teste Exato de Fisher para os itens sujidade e defeitos e Teste U de Mann-Whitney com estatística descritiva, média, desvio padrão, coeficiente de variação e inferência estatística utilizando nível de significância de 5% no teste de Kolmogorov-Smirnov para o item deformações. A determinação do Coeficiente de Correlação Intraclasse para verificar concordância entre os avaliadores foi realizada pelo Teste de Kappa. Resultados: A diferença estatisticamente significante ocorreu entre Mtwo com outros instrumentos no item sujidade (p<0,05). Houve diferença estatisticamente significante entre Twisted File e outros instrumentos (p<0,05) quanto a defeitos. Não houve diferença estatisticamente significante quanto a deformações entre os grupos (p>0,05). Conclusão: Todos os instrumentos estavam sujos, exceto a marca Mtwo. A presença de defeitos foi observada em todos os instrumentos Twisted File, enquanto que para os instrumentos BioRaCe e Mtwo este índice foi menor. Os instrumentos EndoWave não apresentaram os defeitos citados. Quanto à deformação para os grupos avaliados, os mesmos comportaram-se de forma semelhante. / Objectives: It was assessed, by using SEM, some endodontic instruments of Ni-ti rotary systemb, before and after using them, considering their cleanness, defects and deformities. Method: Twenty instruments from the trademarks Twisted File, BioR&#261;Ce, Mtwo and EndoWave were micrographed by increasing them 190 times to check their cleanness. The files were washed and micrographed again to visualize alterations as the presence or absence of irregular edge, groove, microcavity and scraping. Simulated root canal preparation was performed using these instruments. The instruments were cleaned and received a microscopic analysis after they were used five times. After the analysis using SEM and having the avaliators scores, the results were statistically compared using the Fishers Exact Test for the items dirt and defects, and the "U" Mann-Whitneys Test with descriptive statistics, the average data, the standard deviation, the coefficient variation and statistical inference, using a significance level of 5% in the Kolmogorov-Smirnov Test for the item deformations. The determination of the intraclass correlation coefficient for evaluating agreement between the avaliators was done using the Kappa Test. Results: A statistically significant difference occurred between Mtwo and the other instruments analyzed, on the item dirt (p<0.05). There was, also, a statistically significant difference related to deformities between the Twisted File and the other instruments (p<0.05). There was no statistically significant difference on deformities between the groups (p>0.05). Conclusion: All instruments were dirty, except the brand Mtwo. All instruments Twisted File showed some defects, however damage was lower on the BioR&#261;Ce and Mtwo. The EndoWave instruments didnt show the related defects. On the other hand, all groups of instruments evaluated showed similar deformation.
8

The efficacy of rotary and manual instruments in root canal debridement

Madlabane, Duduzile January 2009 (has links)
Magister Chirurgiae Dentium (MChD)
9

Evaluation of dentine damage after rotary NiTi preparation

Ahmed, Suwayda January 2016 (has links)
Magister Scientiae Dentium - MSc(Dent) / NiTi rotary instruments have shape memory and are highly flexible and super-elastic. These properties of the metal alloy allows for ease of root canal preparation to ultimately result in a root canal preparation that has a continuous taper, while canal shape and curvature is maintained. It must be noted that the NiTi rotary instrumentation may have an effect on root canal dentine, which may manifest as dentine damage. Different NiTi rotary systems on the market vary with regards to their design features and kinematics, which may influence dentine damage. The purpose of this in-vitro study was to compare the effect of four different NiTi rotary systems, as well as stainless steel files on root canal dentine. One hundred and eighty permanent human mandibular molar mesial roots were used for the study. The total samples were randomly divided into six groups, where one group (n=30) was left unprepared to serve as the control group. The remaining five groups were randomly assigned to a nickel-titanium rotary instrumentation system and one stainless steel hand file group. Group 1: Control group; Group 2: Stainless steel files group; Group 3: Wave One (Dentsply Maillefer) rotary group; Group 4: ProTaper NEXT (Dentsply Maillefer) rotary group; Group 5: iRaCe (FKG Dentaire) rotary group; Group 6: BT-Race (FKG Dentaire) rotary group.The root canal preparations were carried out according to the manufacturers' recommendations, after decoronation of the tooth crowns. Sodium hypochlorite (5,25%) and 17% EDTA was used as a root canal irrigant and a chelating agent during canal preparation. Each root segment was sectioned at 3mm, 6mm and 9mm from the apex. The root segments were observed under a stereomicroscope at 12x magnification and digital camera at 40 x magnification for the appearance of dentine damage. The images were observed by the author and an impartial second observer. Root segments were observed for the appearance of dentine damage (microcracks, craze lines or fractures), and samples were described as having 'dentine defect' or 'no dentine defect'. Data for the different groups were collected and results were calculated and the total incidence of dentine damage was as follows: Control group = 0% Stainless steel hand files group = 0% Wave One group = 56, 67% ProTaper NEXT group = 60% iRaCe group = 60% BT-Race group = 56, 67% There are no significant differences between the groups: WaveOne, ProTaper NEXT, iRACE and BT-Race. However, there is a significant difference between the four groups and the stainless steel group (p<0.0001).
10

Avaliação da eficiência de sistemas rotatórios para desobturação em canais curvos, por meio de tomografia computadorizada por feixe cônico / Evaluation of the efficiency of rotary systems for remove filling materials in curved canals through cone beam computed tomography

Costa, Giovana Borba Gazzinelli 02 December 2013 (has links)
O presente estudo teve por objetivo avaliar ex vivo a eficiência de sistemas para retratamento (ProTaper Universal Retratamento, Mtwo Retratamento e D-Race), na desobturação de canais mésio vestibulares curvos de molares superiores, por meio de tomografia computadorizada por feixe cônico. Foram utilizados canais mésio vestibulares com curvatura entre 20° e 40°, de 36 molares superiores, preparados com Protaper Universal (até instrumento F2), obturados com cone ProTaper F2 e cimento AH Plus, pela técnica de condensação lateral. Para a desobturação, os dentes foram divididos em grupos (I: ProTaper Universal Retratamento, II: Mtwo Retratamento e III: D-Race). A captura das imagens foi realizada após a obturação e após a desobturação dos canais radiculares, por meio de tomografia computadorizada por feixe cônico de pequeno volume (Prexion 3D XTrillion Inc). As imagens foram segmentadas utilizando o programa InVesalius, para verificar o material obturador remanescente. O tempo para desobturação também foi analisado. De posse dos valores, iniciais e finais, de volume de material obturador e de estrutura dentinária, a proporção dos volumes foi calculada. Para a análise estatística, os resultados foram avaliados pelos testes de ANOVA e de Múltiplas Comparações de Bonferroni. Os grupos ProTaper Universal Retratamento (13,97%) e D-Race (9,87%), apresentaram os menores volumes percentuais médios de material obturador remanescente, não havendo diferença estatística significante entre eles; porém, apresentaram diferença estatística significante (p 0,05) do grupo Mtwo Retratamento (33,88%). Os três sistemas provocaram desgaste semelhante de dentina após a desobturação. O grupo D-Race apresentou menor tempo para desobturação, estatisticamente diferente em relação aos demais sistemas. As características dos sistemas de retratamento podem interferir na eficiência de desobturação quanto ao tempo e volume de material remanescente. / The present study aimed to evaluate, ex vivo, the efficiency of systems for retreatment (ProTaper Universal Retreatment, Mtwo Retreatment and D-Race), in removal filling material of curved mesiobuccal canals of maxillary molars, using cone beam computed tomography. Were used mesiobuccal canals with curvature between 20 ° and 40 °, of 36 molars prepared with ProTaper Universal (until instrument F2), filled with cone F2 ProTaper and AH Plus sealer by lateral condensation. For the removal procedure of filling material, the teeth were divided into groups (I: Protaper Universal Retreatment, II: Mtwo Retreatment and III: D-Race). The capture of images was performed after filling and after the removal procedure of root canal through cone beam computed tomography of small volume (Prexion 3D - XTrillion Inc). The images were segmented using the software InVesalius to check the remaining filling material. The time for removal procedure was also analyzed. Possession of values, initial and final, of volume filling material and dentin structure, the ratio of the volumes was calculated. For statistical analysis, the results were evaluated by ANOVA and Bonferroni\'s Multiple Comparisons. ProTaper Universal Retreatment (13.97 %) and D-Race (9.87 %) groups had the lowest average percent volume remaining filling material, with no statistically significant difference between them, but showed a statistically significant difference (p 0.05) group Mtwo Retreatment (33.88 %). The three systems caused similar wear dentin after removal procedure. The group D-Race had less time for removal procedure, statistically different compared to the other systems. The characteristics of retreatment systems may interfere with the efficiency of removal procedure on the time and volume remaining material.

Page generated in 0.1002 seconds