1

Bone anchored hearing aids (BAHAs) in children /

Priwin, Claudia, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2006. / Härtill 4 uppsatser.
2

Ocorrência de alterações de orelha média em recém nascidos que falharam na triagem auditiva neonatal / Occurrence of condutive hearing loss in newborns who failed the hearing screening

Pereira, Priscila Karla Santana [UNIFESP] 28 January 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-28 / Objetivo: verificar a ocorrência das alterações auditivas em recém nascidos que participaram do Programa de triagem auditiva neonatal de um Hospital Público (UNIFESP- Brasil) no período de 2005 a 2007 e verificar se os recém nascidos que falharam na triagem auditiva por comprometimento condutivo tem mais episódios de perda condutiva durante os primeiros anos de vida do que aqueles que não falharam. Métodos: 0 estudo foi dividido em duas partes. A primeira parte foi retrospectiva analisando-se 0 diagnóstico audiol6gico de 231 (de mil novecentos e noventa e seis) recém nascidos que falharam na triagem auditiva e sua associação com a idade gestacional, 0 peso ao nascimento e as principais intercorrências neonatais. Na segunda parte compararam-se os 62 recém nascidos que falharam na triagem auditiva por comprometimento condutivo com os 221 recém nascidos que passaram na triagem auditiva. Foi feito 0 acompanhamento por meio de EOAT, imitanciometria e avaliação comportamental. Foram utilizados para analise estatística 0 teste Exato de Fisher e modelos de Regressão Logística. Resultados: A incidência de alterações auditivas na população estudada foi de 11,5%, sendo 8,4% de perda condutiva, 1 % de perda neurossensorial, 2% de alteração central. As crianças que falharam na triagem por alteração condutiva tiveram mais episódios de perda condutiva (estatisticamente significante) durante 0 primeiro ano de vida que as crianças que não falharam. Conclusões: Houve maior ocorrência de perda auditiva condutiva dentre as alterações auditivas estudadas. Os neonatos que falharam na triagem auditiva neonatal no primeiro mês de vida por alteração condutiva tem maior chance de terem perda auditiva condutiva ao longo do primeiro ano de vida. / TEDE / BV UNIFESP: Teses e dissertações
3

Maturação cortical e habilidades auditivas em usuários experientes de Vibrant Soundbridge: estudo eletrofisiológico e comportamental / Cortical maturation and auditory skills in experienced users of Vibrant Soundbridge: electrophysiological and behavioral study

Pizarro, Luzia Maria Pozzobom Ventura 15 June 2018 (has links)
Introdução: A atresia congênita de orelha constitui uma deformidade presente ao nascimento, de prevalência unilateral, decorrente da alteração no desenvolvimento das estruturas das orelhas externa e média. Geralmente, provoca perda auditiva condutiva, e pode ser acompanhada por componente sensorioneural. Dentre as formas de tratamento disponíveis, encontra-se o implante de orelha média Vibrant Soundbridge (VSB), que tem se mostrado eficaz no tratamento deste tipo de alteração. A literatura mostra melhora nos limiares tonais e nos resultados dos testes de percepção auditiva da fala, realizados com o uso do processador de fala após a cirurgia. Considerando que os indivíduos com este tipo de malformação podem passar por um período de privação sensorial auditiva anterior à reabilitação, torna-se interessante avaliar o estágio maturacional das estruturas auditivas corticais e o processamento das informações auditivas em nível central, bem como, verificar o benefício da indicação do VSB unilateral em situação de escuta difícil. Não foram encontrados estudos que abordam este aspecto e o emprego dos potenciais evocados auditivos corticais (PEAC) e do P300 em usuários de VSB. Objetivo: Analisar o impacto da perda auditiva condutiva e mista nos PEAC e P300 em usuários de VSB unilateral, com atresia de orelha bilateral, e verificar as habilidades auditivas, em situação de escuta difícil, considerando a indicação do VSB unilateral. Casuística e método: Vinte indivíduos, divididos em dois grupos, pareados em idade, sexo e grau de escolaridade. G1: dez indivíduos com perda auditiva condutiva ou mista bilateral, usuários de VSB unilateral, atendidos na Instituição de realização da pesquisa. Todos fizeram uso de aparelhos auditivos convencionais antes do VSB. G2: Dez indivíduos normo-ouvintes. Realização de audiometria em campo livre com o uso do VSB (apenas o G1), avaliação das habilidades auditivas pelo Hearing in Noise Test, pesquisa dos componentes P1, N1, P2, N2 e P300, em campo calibrado. Resultados: A média dos limiares tonais nas frequências de 500 a 3000 Hz, de 20 a 36 dB NA, mostrou que o VSB possibilitou o acesso aos sons da fala. Não foi observada diferença estatisticamente significante entre os valores de latência dos PEAC e P300 entre os grupos. Foi observada diferença estatisticamente significante entre o limiar de reconhecimento de sentenças e a relação sinal/ruído entre os grupos, sendo os melhores resultados apresentados pelo G2. Conclusão: Indivíduos com atresia de orelha e perda auditiva condutiva ou mista bilateral, quando adequadamente reabilitados, podem atingir a maturação das vias auditivas centrais e o processamento da informação auditiva em nível cortical. As habilidades de reconhecimento auditivo, sem e com ruído competitivo, mostraram-se defasadas quanto à normalidade, apontando para a indicação do VSB bilateral / Introduction: Congenital aural atresia is a congenital deformity. It is unilaterally prevalent due to alterations in the development of the external and middle ear structures. Congenital aural atresia causes conductive hearing loss and can be accompanied by sensorineural component. Among the available forms of treatment is the middle ear implant, Vibrant Soundbridge (VSB), which has been shown to be effective in treating this type of alteration. The literature shows improvement in tonal thresholds and in the results of tests of auditory perception of speech that were performed using the speech processor after surgery. Individuals with this type of malformation often experience a period of auditory sensory deprivation prior to rehabilitation. Hence, it is important to evaluate the maturation stage of the cortical auditory structures, the processing of auditory information at the central level, and to verify the benefit of unilateral VSB in difficult listening situations. There are no previous data on this aspect and with the use of cortical auditory evoked potentials (CAEP) and event-related potential (P300) in users of VSB. Aim: To analyze the impact of conductive and mixed hearing loss on CAEP and P300 in unilateral VSB users with bilateral ear atresia. To verify the auditory abilities in a difficult listening situation considering the indication for unilateral VSB. Materials and methods: Twenty individuals were divided into two groups matched for age, sex, and educational level. G1 comprised ten individuals with bilateral conductive or mixed hearing loss and users of unilateral VSB, who visited the research institution. All subjects used conventional hearing aids prior to VSB. G2 comprised ten normal hearing individuals. Audiometry in the free field was performed with the use of VSB (G1 only) and evaluation of hearing skills by the Hearing in Noise Test was conducted; components P1, N1, P2, N2, and P300 in a calibrated field were recorded. Results: Evaluation of the mean tonal thresholds in the frequencies between 500 and 3000 Hz, from 20 to 36 dB HL, demonstrated that VSB allowed access to speech sounds. There was no statistically significant difference in the CAEP and P300 latency values between the two groups. A statistically significant difference was observed in the sentence recognition threshold and the signal-to-noise ratio between the groups, with best results presented by G2. Conclusion: Individuals with congenital aural atresia and bilateral conductive or mixed hearing loss may reach maturation of the central auditory pathway and achieve adequate processing of auditory information at the cortical level, when rehabilitated. The auditory recognition skills, with and without competitive noise, were shown to be out of phase with normality, indicating the need for a bilateral VSB
4

Maturação cortical e habilidades auditivas em usuários experientes de Vibrant Soundbridge: estudo eletrofisiológico e comportamental / Cortical maturation and auditory skills in experienced users of Vibrant Soundbridge: electrophysiological and behavioral study

Luzia Maria Pozzobom Ventura Pizarro 15 June 2018 (has links)
Introdução: A atresia congênita de orelha constitui uma deformidade presente ao nascimento, de prevalência unilateral, decorrente da alteração no desenvolvimento das estruturas das orelhas externa e média. Geralmente, provoca perda auditiva condutiva, e pode ser acompanhada por componente sensorioneural. Dentre as formas de tratamento disponíveis, encontra-se o implante de orelha média Vibrant Soundbridge (VSB), que tem se mostrado eficaz no tratamento deste tipo de alteração. A literatura mostra melhora nos limiares tonais e nos resultados dos testes de percepção auditiva da fala, realizados com o uso do processador de fala após a cirurgia. Considerando que os indivíduos com este tipo de malformação podem passar por um período de privação sensorial auditiva anterior à reabilitação, torna-se interessante avaliar o estágio maturacional das estruturas auditivas corticais e o processamento das informações auditivas em nível central, bem como, verificar o benefício da indicação do VSB unilateral em situação de escuta difícil. Não foram encontrados estudos que abordam este aspecto e o emprego dos potenciais evocados auditivos corticais (PEAC) e do P300 em usuários de VSB. Objetivo: Analisar o impacto da perda auditiva condutiva e mista nos PEAC e P300 em usuários de VSB unilateral, com atresia de orelha bilateral, e verificar as habilidades auditivas, em situação de escuta difícil, considerando a indicação do VSB unilateral. Casuística e método: Vinte indivíduos, divididos em dois grupos, pareados em idade, sexo e grau de escolaridade. G1: dez indivíduos com perda auditiva condutiva ou mista bilateral, usuários de VSB unilateral, atendidos na Instituição de realização da pesquisa. Todos fizeram uso de aparelhos auditivos convencionais antes do VSB. G2: Dez indivíduos normo-ouvintes. Realização de audiometria em campo livre com o uso do VSB (apenas o G1), avaliação das habilidades auditivas pelo Hearing in Noise Test, pesquisa dos componentes P1, N1, P2, N2 e P300, em campo calibrado. Resultados: A média dos limiares tonais nas frequências de 500 a 3000 Hz, de 20 a 36 dB NA, mostrou que o VSB possibilitou o acesso aos sons da fala. Não foi observada diferença estatisticamente significante entre os valores de latência dos PEAC e P300 entre os grupos. Foi observada diferença estatisticamente significante entre o limiar de reconhecimento de sentenças e a relação sinal/ruído entre os grupos, sendo os melhores resultados apresentados pelo G2. Conclusão: Indivíduos com atresia de orelha e perda auditiva condutiva ou mista bilateral, quando adequadamente reabilitados, podem atingir a maturação das vias auditivas centrais e o processamento da informação auditiva em nível cortical. As habilidades de reconhecimento auditivo, sem e com ruído competitivo, mostraram-se defasadas quanto à normalidade, apontando para a indicação do VSB bilateral / Introduction: Congenital aural atresia is a congenital deformity. It is unilaterally prevalent due to alterations in the development of the external and middle ear structures. Congenital aural atresia causes conductive hearing loss and can be accompanied by sensorineural component. Among the available forms of treatment is the middle ear implant, Vibrant Soundbridge (VSB), which has been shown to be effective in treating this type of alteration. The literature shows improvement in tonal thresholds and in the results of tests of auditory perception of speech that were performed using the speech processor after surgery. Individuals with this type of malformation often experience a period of auditory sensory deprivation prior to rehabilitation. Hence, it is important to evaluate the maturation stage of the cortical auditory structures, the processing of auditory information at the central level, and to verify the benefit of unilateral VSB in difficult listening situations. There are no previous data on this aspect and with the use of cortical auditory evoked potentials (CAEP) and event-related potential (P300) in users of VSB. Aim: To analyze the impact of conductive and mixed hearing loss on CAEP and P300 in unilateral VSB users with bilateral ear atresia. To verify the auditory abilities in a difficult listening situation considering the indication for unilateral VSB. Materials and methods: Twenty individuals were divided into two groups matched for age, sex, and educational level. G1 comprised ten individuals with bilateral conductive or mixed hearing loss and users of unilateral VSB, who visited the research institution. All subjects used conventional hearing aids prior to VSB. G2 comprised ten normal hearing individuals. Audiometry in the free field was performed with the use of VSB (G1 only) and evaluation of hearing skills by the Hearing in Noise Test was conducted; components P1, N1, P2, N2, and P300 in a calibrated field were recorded. Results: Evaluation of the mean tonal thresholds in the frequencies between 500 and 3000 Hz, from 20 to 36 dB HL, demonstrated that VSB allowed access to speech sounds. There was no statistically significant difference in the CAEP and P300 latency values between the two groups. A statistically significant difference was observed in the sentence recognition threshold and the signal-to-noise ratio between the groups, with best results presented by G2. Conclusion: Individuals with congenital aural atresia and bilateral conductive or mixed hearing loss may reach maturation of the central auditory pathway and achieve adequate processing of auditory information at the cortical level, when rehabilitated. The auditory recognition skills, with and without competitive noise, were shown to be out of phase with normality, indicating the need for a bilateral VSB