• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 349
  • 79
  • 65
  • 30
  • 29
  • 12
  • 10
  • 9
  • 8
  • 7
  • 4
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 751
  • 751
  • 106
  • 85
  • 78
  • 77
  • 70
  • 65
  • 62
  • 60
  • 58
  • 50
  • 49
  • 48
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Extended High-frequency Audiometry and Distortion Product Otoacoustic Emissions in Normal-hearing Patients with Unilateral Tinnitus

Smurzynski, Jacek, Fabijanska, Anna, Kochanek, Krzysztof, Skarzynski, Henryk 24 June 2009 (has links)
Some tinnitus patients have normal hearing on the conventional audiogram. It has been suggested that the presence of a limited area of damaged outer hair cells (OHCs) with intact inner hair cells, which is not detected on the audiogram, results in unbalanced neural activity between Type I and Type II fibers leading to tinnitus. Distortion product otoacoustic emissions (DPOAEs) provided ambiguous data of OHC function in normal-hearing tinnitus patients when compared to non-tinnitus controls. It is known that hearing loss in the extended high frequency (EHF) region may decrease DPOAEs evoked at lower frequencies. Results of EHF audiometry in tinnitus patients are limited. The aim of the study was to evaluate DPOAEs and EHF thresholds in normal-hearing patients reporting unilateral tinnitus in left ear. Thus, each subject acted as their own control. Data were obtained for 25 subjects with bilateral hearing thresholds 3dB. Median audiometric data showed that thresholds in the left ears were significantly higher than those in the right ears at all four EHFs. Mean DPOAE levels of the left ears were lower than those of the right ears in the frequency range above 1 kHz. Additionally, a paired-comparison test of DPOAE levels of each patient’s right and left ear revealed significant differences at 6, and 8 kHz. The results indicate that: 1. OHC impairment in the most basal region reduces contribution to more apically generated DPOAEs; 2. OHC impairment in a limited area, which may be revealed by DPOAEs but not by conventional audiometry, can contribute to tinnitus generation; and 3. patients with unilateral tinnitus and normal hearing on the conventional audiogram are likely to demonstrate hearing loss in the EHF region.
322

An Initial-Fit Comparison of Two Generic Hearing Aid Prescriptive Methods (NAL-NL2 and CAM2) to Individuals Having Mild to Moderately Severe High-Frequency Hearing Loss

Johnson, Earl E. 01 February 2013 (has links)
Background: Johnson and Dillon (2011) provided a model-based comparison of current generic hearing aid prescriptive methods for adults with hearing loss based on the attributes of speech intelligibility, loudness, and bandwidth. Purpose: This study compared the National Acoustic Laboratories-Non-linear 2 (NAL-NL2) and Cambridge Method for Loudness Equalization 2-High-Frequency (CAM2) prescriptive methods using adult participants with less high-frequency hearing loss than Johnson and Dillon (2011). Of study interest was quantification of prescribed audibility, speech intelligibility, and loudness. The preferences of participants for either NAL-NL2 or CAM2 and preferred deviations from prescribed settings are also reported. Research Design: Using a single-blind, counter-balanced, randomized design, preference judgments for the prescriptive methods with regard to sound quality of speech and music stimuli were obtained. Preferred gain adjustments from the prescription within the 4-10 kHz frequency range were also obtained from each participant. Speech intelligibility and loudness model calculations were completed on the prescribed and adjusted amplification. Study Sample: Fourteen male Veterans, whose average age was 65 yr and whose hearing sensitivity averaged normal to borderline normal through 1000 Hz sloping to a moderately severe sensorineural loss, served as participants. Data Collection and Analysis: Following a brief listening time (∼10 min), typical of an initial fitting visit, the participants made paired comparison of sound quality between the NAL-NL2 and CAM2 prescriptive settings. Participants were also asked to modify each prescription in the range of 4-10 kHz using an overall gain control and make subsequent comparisons of sound quality preference between prescriptive and adjusted settings. Participant preferences were examined with respect to quantitative analysis of loudness modeling, speech intelligibility modeling, and measured high-frequency bandwidth audibility. Results: Consistent with the lack of difference in predicted speech intelligibility between the two prescriptions, sound quality preferences on the basis of clarity were split across participants while some participants did not have a discernable preference. Considering sound quality judgments of pleasantness, the majority of participants preferred the sound quality of the NAL-NL2 (8 of 14) prescription instead of the CAM2 prescription (2 of 14). Four of the 14 participants showed no preference on the basis of pleasantness for either prescription. Individual subject preferences were supported by loudness modeling that indicated NAL-NL2 was the softer of the two prescriptions and CAM2 was the louder. CAM2 did provide more audibility to the higher frequencies (5-8 kHz) than NAL-NL2. Participants turned the 4-10 kHz gain recommendation of CAM2 lower, on average, by a significant amount of 4 dB when making adjustments while no significant adjustment was made to the initial NAL-NL2 recommendation. Conclusions: NAL-NL2 prescribed gains were more often preferred at the initial fitting by the majority of participating veterans. For those patients with preference for a louder fitting than NAL-NL2, CAM2 is a good alternative. When the participant adjustment from the prescription between 4 and 10 kHz exceeded 4 dB from either NAL-NL2 (2 of 14) or CAM2 (11 of 14), the participants demonstrated a later preference for that adjustment 69% of the time. These findings are viewed as limited evidence that some individuals may have a preference for high-frequency gain that differs from the starting prescription.
323

The Effect of Extending High-Frequency Bandwidth on the Acceptable Noise Level (anl) of Hearing-Impaired Listeners

Johnson, Earl E., Ricketts, Todd, Hornsby, Benjamin 01 January 2009 (has links)
This study examined the effects of extending high-frequency bandwidth, for both a speech signal and a background noise, on the acceptable signal-to-noise ratio (SNR) of listeners with mild sensorineural hearing loss through utilization of the Acceptable Noise Level (ANL) procedure. In addition to extending high-frequency bandwidth, the effects of reverberation time and background noise type and shape were also examined. The study results showed a significant increase in the mean ANL (i.e. participants requested a better SNR for an acceptable listening situation) when high-frequency bandwidth was extended from 3 to 9 kHz and from 6 to 9 kHz. No change in the ANL of study participants was observed as a result of isolated modification to reverberation time or background noise stimulus. An interaction effect, however, of reverberation time and background noise stimulus was demonstrated. These findings may have implications for future design of hearing aid memory programs for listening to speech in the presence of broadband background noise.
324

Tone-Burst-Evoked Otoacoustic Emissions and the Influence of High Frequency Hearing Loss in Humans

Murnane, Owen D., Kelly, J. K., Prieve, B., Murnane, Owen D. 01 January 2000 (has links)
No description available.
325

Ultra-high Frequency (UHF) Hearing and DPOAE Levels at Lower Frequencies

Fabijanska, Anna, Smurzynski, Jacek, Kochanek, Krzysztof, Pilka, Adam, Skarzynski, Henryk 01 January 2008 (has links)
No description available.
326

Extended High-frequency Audiometry and DPOAEs in Patients with Unilateral Tinnitus

Smurzynski, Jacek, Fabijanska, Anna, Kochanek, Krzysztof 01 January 2010 (has links)
No description available.
327

High Frequency Transformer for Switching Mode Power Supplies

Wong, Fu Keung, n/a January 2004 (has links)
A power supply is an essential part of all electronic devices. A switching mode power supply is a light weight power solution for most modern electronic equipment. The high frequency transformer is the backbone of modern switched mode power supplies. The skin effect and proximity effects are major problems in high frequency transformer design, because of induced eddy currents. These effects can result in transformers being destroyed and losing their power transferring function at high frequencies. Therefore, eddy currents are unwanted currents in high frequency transformers. Leakage inductance and the unbalanced magnetic flux distribution are two further obstacles for the development of high frequency transformers. Winding structures of power transformers are also a critical part of transformer design and manufacture, especially for high frequency applications. A new planar transformer with a helical winding structure has been designed and can maintain the advantages of existing planar transformers and significantly reduce the eddy currents in the windings. The maximum eddy current density can be reduced to 27% of the density of the planar transformer with meander type winding structure and 33% of the density of the transformer with circular spiral winding structure at an operating frequency of 1MHz. The voltage ratio of the transformer with helical winding structure is effectively improved to 150% of the voltage ratio of the planar transformer with circular spiral coils. With the evenly distributed magnetic flux around the winding, the planar transformer with helical winding structure is excellent for high frequency switching mode power supplies in the 21st Century.
328

DEVELOPMENT OF HIGH FREQUENCY POWER CONVERSION TECHNOLOGIES FOR GRID INTERACTIVE PV SYSTEMS

Li, Quan, q.li@cqu.edu.au January 2002 (has links)
This thesis examines the development of DC-DC converters that are suitable for Module Integrated Converters, (MICs), in grid interactive photovoltaic (PV) systems, and especially concentrates on the study of the half bridge dual converter, which was previously developed from the conventional half bridge converter. Both hard-switched and soft-switched half bridge dual converters are constructed, which are rated at 88W each and transform a nominal 17.6Vdc input to an output in the range from 340V to 360Vdc. An initial prototype converter operated at 100kHz and is used as a base line device to establish the operational behaviours of the converter. The second hard-switched converter operated at 250kHz and included a coaxial matrix transformer that significantly reduced the power losses related to the transformer leakage inductance. The soft-switched converter operated at 1MHz and is capable of absorbing the parasitic elements into the resonant tank. Extensive theoretical analysis, simulation and experimental results are provided for each converter. All three converters achieved conversion efficiencies around 90%. The progressive increases in the operation frequency, while maintaining the conversion efficiency, will translate into the reduced converter size and weight. Finally different operation modes for the soft-switched converter are established and the techniques for predicting the occurrence of those modes are developed. The analysis of the effects of the transformer winding capacitance also shows that soft switching condition applies for both the primary side mosfets and the output rectifier diodes.
329

Microsturcture des marchés et modelistion des flux de trading.

Dayri, Khalil Antoine 16 January 2012 (has links) (PDF)
On propose une perspective originale d'analyser les différents flux hautes fréquences d'information provenant des marchés financiers et fournit des modèles simples et intuitives qui reflètent étroitement la réalité. On observe les données empiriques et note certains faits stylisés et propose des modèles pour capturer ces faits. Dans le chapitre 1, on passe en revue les définitions et propriétés de base des marchés électroniques. En particulier, on revoit les travaux de microstructure et de modélisation du marché, et leurs relations à ce travail. On introduit la taille du "tick", qu'on utilise pour classifier les actifs et interpréter les différents résultats. Dans le chapitre 2, on montre empiriquement que l'impact d'une seule transaction dépend de la durée inter-transactions. En effet, lorsque le taux des échanges devient plus rapide, la variance des rendements des transactions augmente fortement et que ce comportement persiste à des échelles de temps plus grossières. On montre également que la valeur du spread augmente avec l'activité et on en déduit que les carnets d'ordres sont plus vide lorsque le taux des échanges est élevé. Dans le chapitre 3, on présente un modèle pour capturer le bruit de microstructure. Les prix des actifs sont représentés par la somme des rendements "tick" arrivant à des temps de Poisson aléatoires. Le modèle se compose d'une martingale diffusive contaminée par un bruit autocorrélé mais disparaissant aux échelles grossières. On est capable de capturer la signature de la variance et l'autocorrélation faible mais significative des rendements "tick". Dans le chapitre 4, on utilise les processus ponctuels de Hawkes pour modéliser l'arrivée aléatoire des transactions. On modélise la transformation échelle fine - échelle grossière des prix et en particulier l'effet sur les moments des rendements des prix. On propose une technique simple d'estimation non paramétrique de la structure de dépendance des processus de Hawkes dans le cas unidimensionnel et dans quelques cas particuliers multidimensionnels. On applique la méthode à des actifs de Future et trouve des noyaux de dépendance en loi de puissance.
330

En oscillatorbank till en lågfrekvensradar : LORA/VHF / An oscillator bank for a low-frequency radar : LORA/VHF

Blom, Martin January 2004 (has links)
<p>The goal of this thesis work is to enable an existing UHF radar to operate in the VHF band instead. In order to achieve this, new coherent local oscillators are required. Different options are suggested and one of them is implemented and analyzed.</p>

Page generated in 0.2479 seconds