Spelling suggestions: "subject:"hormônios estrogênio e urine"" "subject:"hormônios estrogênica e urine""
1 |
Desenvolvimento de um método por ponto nuvem dos hormônios naturais E1 e E2 em amostras de urina e determinação por CLAE/EC utilizando eletrodo de diamante dopado com boro / Development of a cloud point method of E1 and E2 natural hormones from urine samples and determination by HPLC/EC using boron doped diamondAmorim, Kamila Pereira de 06 August 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:39:40Z
No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:41:11Z (GMT) No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-08T08:41:11Z (GMT). No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-08-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Cloud point extraction method (CPE) was used for the determination of estrone (E1) and 17β-estradiol (E2) hormones in human urine. The combination of the electrochemical detection techniques with high-performance liquid chromatography (HPLC-EC) was used for the detection and quantification of these hormones. A boron doped diamond electrode (BDD) pretreated cathodically was used as electrode material for all electrochemical measurements. The optimized chromatographic parameters resulted in a mobile phase composition of KH2PO4 (0.01 mol L-1; pH 5.0) / ACN (72:28 V/V), flow 1.2 ml min-1. An applied potential for electrochemical detection of 1.0 V x Ag/AgCl (3.0 mol L-1) was selected from hydrodynamic voltammograms constructed for each hormone changing the potential between 0.3 V and 1.2 V x Ag/AgCl (3.0 mol L-1). Limits of detection (S/N = 3) of 500 ng mL-1 and limits of quantification of 800 ng mL-1 were obtained for both E1 and E2 hormones without any extraction process. Urine samples at pH 5.0 and 7.0 were investigated aiming the influence of pH on the efficiency of the CPE process, and the optimum results for the most current signal of the hormones was obtained at pH 7.0. Extractor solvent volumes were changed in the 0.5-2.5 mL range, and the optimum results were obtained when using 1.0 mL of Tergitol TMN-6 surfactant (10% aqueous solution). From the equation of the calibration curves obtained with and without the CPE procedure it was possible to determine the pre-concentration factor (FC) and all the other parameters involving the efficiency of CPE method. A comparison of the efficiency of CPE method with direct liquid-liquid extraction with the organic solvent CCl4 was carried out and the results showed that the CPE method was quite superior to liquid-liquid extraction. The validation of the method was carried out from intra-day recovery experiments and inter-day and evaluated the accuracy, precision and repeatability. The proposed method was applied to individual samples of urine of 1 man, 1 pregnant woman, 1 woman in fertile age, and 1woman in lactating stage. The values of the variation coefficients of the recovery percentages were lower than 15%. / Método de extração por ponto nuvem (EPN) foi usado para a determinação dos hormônios estrona (E1) e 17β-estradiol (E2) em urina humana. A combinação entre as técnicas de detecção eletroquímica e cromatografia líquida de alta eficiência (CLAE-EC) foi usada para a detecção e quantificação desses hormônios. Um eletrodo de diamante dopado com boro (DDB) pré-tratado catodicamente foi usado como material de eletrodo para todas as determinações eletroquímicas. Os parâmetros cromatográficos otimizados resultaram em uma composição de fase móvel de KH2PO4 (0,01 mol L-1; pH 5,0) / ACN (72:28 V/V) vazão de 1,2 mL min-1. Um potencial aplicado para a detecção eletroquímica de 1,0 V x Ag/AgCl (3 mol L-1) foi selecionado a partir de voltamogramas hidrodinâmicos construídos para cada hormônio variando-se o potencial entre 0,3 V e 1,2 V x Ag/AgCl (3,0 mol L-1). Limites de detecção (S/R = 3) de 500 ng mL-1 e limites de quantificação de 800 ng mL-1 foram obtidos para ambos os padrões dos hormônios E2 e E1 sem qualquer processo de extração. Amostras de urina em pH 5,0 e 7,0 foram investigadas quanto a influência do pH na eficiência do processo de extração, e o melhor resultado referente ao maior sinal de corrente dos hormônios foi obtido em pH 7,0. Os volumes de solvente extrator foram variados na faixa de 0,5-2,5 mL e o melhor resultado referente ao sinal de corrente dos hormônios foi obtido pelo uso de 1,0 mL de solução aquosa 10% do surfactante Tergitol TMN-6. A partir da equação da reta obtida das curvas analíticas, com e sem o procedimento de EPN, foi possível determinar o fator de pré-concentração (FC) e todos os demais parâmetros envolvendo a eficiência do método de EPN. Uma comparação sobre a eficiência dos métodos de EPN com extração direta líquido-líquido com o solvente orgânico CCl4 foi realizada e os resultados mostraram que método de EPN mostrou-se bastante superior a extração líquido-líquido. A validação do método foi feita a partir de ensaios de recuperação intra-dia e inter-dia, sendo avaliadas a exatidão, precisão e repetitividade. O método proposto foi aplicado em amostras individuais de urina de 1 homem, 1 mulher gestante, 1 mulher em idade fértil e 1 mulher lactante. Os valores dos coeficientes de variação das porcentagens de recuperação foram menores que 15%.
|
Page generated in 0.1065 seconds