• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 67
  • 67
  • 41
  • 24
  • 14
  • 12
  • 12
  • 12
  • 12
  • 12
  • 10
  • 10
  • 10
  • 10
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da microbiota fúngica e presença de micotoxinas em amostras de plantas medicinais irradiadas, adquiridas no comércio varejista e atacadista / Evaluation of fungal bioburden and micotoxins presence in irradiated samples of medicinal plants purchased from wholesale and retail market

Simone Aquino 13 November 2007 (has links)
O presente estudo analisou os efeitos da radiação gama na sobrevivência de fungos em plantas medicinais embaladas, adquiridas do comércio atacadista e varejista, em diferentes períodos (0 e 30 dias) após o tratamento por irradiação. Cinco tipos de plantas medicinais [Peumus boldus, Cameilia sinensis, Maytenus ilicifolia, Pauilinia cupana and Cássia angustifolia), foram coletadas de diferentes municípios do Estado de São Paulo e submetidas ao tratamento por irradiação, utilizando-se uma fonte 60Co (tipo Gammacell 220), com doses de 5,0 kGy e 10 kGy e taxa de dose de 3,0 kGy/h. Amostras não irradiadas (grupo controle) foram usadas na contagem de fungos e diluições seriadas de 10-1 a 10-6 das amostras foram semeadas em duplicata e plaqueadas usando o método de cultura em superfície, em ágar Dicloran Glicerol 18% (DG18) e contadas após cinco dias a 25°C. O grupo controle revelou a presença dos gêneros Aspergilius e Penicillium, os quais são conhecidos como fungos toxigênicos e poucas amostras do grupo controle estavam dentro dos limites seguros, estabelecidos pela Organização Mundial de Saúde (OMS, 1998) para plantas medicinais. Em resposta a resistência do tratamento por ionização, na dose de 5 kGy, foi obsen/ado que os gêneros Aspergilius, Piioma e Syncephalastrum foram radiorresistentes, após o processo (dia 0 e 30° dia). O tratamento por radiação gama foi efetivo na descontaminação de todas as amostras de plantas medicinais, após 30 dias, com a dose de 10 kGy e mantidas em condições de vedação. Não foram detectadas aflatoxinas nas amostras do grupo controle, ainda que estas amostras estivessem intensamente contaminadas com Aspergilius flavus. / This present study evaluated the effect of gamma radiation on the fungal survival in packed medicinal plants, purchased from wholesale and retail market, in different period (0 and 30 days) after the treatment. Five kind of medicinal plants (Peurnus boldus, Camellia sinensis, Maytenus ilicifolia, Pauilinia cupana and Cassia angustifolia), were collected from different cities of São Paulo State, and submitted to irradiation treatment using a 60Co source (type Gammacell 220) with doses of 5,0 kGy and 10 kGy and at dose rate of 3.0 kGy/h. Non-irradiated samples (control group) were used for fungal counts and serial dilutions from 10-1 to 10-6 of the samples were seeded in duplicates and plated using the surface culture method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25°C. The control group revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi and a few samples of control group were within the safety limits of World Health Organization (WHO, 1998) to medicinal plants. In response to resistance of ionizing treatment, in the dose of 5 kGy, it was obsen/ed that the genera Aspergillus, Phoma and Syncephalastrum were radio-resistant after the process (day 0 and 30° day). The treatment by gamma radiation was effective in decontamination of all irradiated samples of medicinal plants, after 30 days, with the dose of 10 kGy and kept of veiled conditions. It was not detected aflatoxins in samples of control group, even though these samples were heavily contaminated with Aspergillus flavus.
52

Desempenho sob irradiação de elementos combustíveis do tipo U-Mo

ALMEIDA, CIRILA T. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:53Z (GMT). No. of bitstreams: 1 10885.pdf: 6800168 bytes, checksum: 564283882a42941e0a49be623bd8981e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
53

Câmara de ionização aplicada a medidas de altas taxas de dose

RODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
54

Medidas de seccoes de choque para reacoes de captura de neutrons no sup(57)Co, sup(137)Cs e sup(241)Am considerando a formacao de estados isomericos

MAIDANA, NORA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:38Z (GMT). No. of bitstreams: 1 06881.pdf: 7889902 bytes, checksum: 7e22a20905b1e2b2ff4ed4439b25e2bb (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
55

Caracterizacao do topazio natural para aplicacoes dosimetricas na faixa terapeutica

SOUZA, DIVANIZIA do N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:18Z (GMT). No. of bitstreams: 1 07923.pdf: 9394711 bytes, checksum: df7d9fe1d70a7a5ba73e4ffdbe4e11e8 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
56

Avaliação da microbiota fúngica e da presença de micotoxinas em amostras de plantas medicinais irradiadas adquiridas no comércio varejista e atacadista

AQUINO, SIMONE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:30Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:35Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
57

Análise do comportamento sob irradiação do combustível nuclear a altas queimas com os programas computacionais FRAPCON e FRAPTRAN / Analysis of the behavior under irradiation of high burnup nuclear fuels with the computer programs FRAPCON and FRAPTRAN

REIS, REGIS 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:11:38Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:11:38Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
58

Desempenho sob irradiação de elementos combustíveis do tipo U-Mo

ALMEIDA, CIRILA T. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:53Z (GMT). No. of bitstreams: 1 10885.pdf: 6800168 bytes, checksum: 564283882a42941e0a49be623bd8981e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
59

Radiografia com elétrons induzida por nêutrons: Neutron induced eletron radiography

ANDRADE, MARCOS L.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:58Z (GMT). No. of bitstreams: 1 12342.pdf: 14453245 bytes, checksum: d663bec3e62922a0d773fb585931e4de (MD5) / No presente trabalho foi desenvolvida uma nova técnica radiográfica que utiliza feixes de elétrons de baixa energia como radiação penetrante para inspecionar amostras finas com espessuras da ordem de micra. Esta técnica é denominada, radiografia com elétrons induzida por nêutrons e os feixes são obtidos mediante a irradiação de uma tela de gadolínio com nêutrons térmicos. Foram determinadas as condições ótimas para a obtenção de radiografias no filme convencional para raios - X, Kodak Industrex AA, utilizando um sistema digital para análise do grau de enegrecimento dos filmes. Todas as irradiações foram realizadas em um equipamento radiográfico instalado no canal de irradiação 08 do reator nuclear de pesquisas IEA-R1 do IPEN-CNEN/SP. O tempo de irradiação necessário para se obter a radiografia com o melhor contraste foi de 100 segundos e nesta condição foi possível discernir 1 ?m em 24 ?m de alumínio com uma resolução máxima de 32 ?m. As imagens radiográficas obtidas no IPENCNEN/ SP por esta técnica apresentam visualmente uma qualidade superior quando comparadas as obtidas pelas outras técnicas radiográficas usuais que utilizam elétrons como radiação penetrante e filmes para o registro da imagem. Além disto, o sistema digital propiciou uma maior praticidade referente à aquisição e a análise dos dados e uma melhor visualização das imagens radiográficas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
60

Câmara de ionização aplicada a medidas de altas taxas de dose

RODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Irradiadores comerciais de grande porte são projetados para processarem grandes quantidades de produtos com altas doses, por exposição à radiação gama. A irradiação em escala industrial é efetuada de forma dinâmica, em que os produtos percorrem um caminho em torno de uma fonte de radiação, geralmente de 60Co, cuja atividade é da ordem de TBq a PBq (kCi a MCi). A dose será diretamente proporcional ao tempo transcorrido pelo material para percorrer este trajeto em torno da fonte. Entretanto, em algumas situações, principalmente para pesquisas ou processos de validação de clientes seguindo a norma ISO 11137, se faz necessário irradiar pequenas amostras com doses fracionadas na posição de irradiação estática. Nesta posição as amostras são colocadas dentro da sala de irradiação a uma distância fixa da fonte e as doses recebidas são determinadas utilizando-se dosímetros. Portanto, a dose somente será conhecida depois da irradiação, pela leitura dos mesmos. Entretanto, em irradiadores industriais, diferentes tipos de produtos com diferentes densidades atravessam o caminho entre a fonte e a posição de irradiação estática, onde estão as amostras. Conseqüentemente, a taxa de dose variará dependendo da densidade do produto, que está sendo irradiado dinamicamente. Uma metodologia adequada seria monitorar a dose recebida pelas amostras em tempo real, medindo a dose por meio de um detector de radiação, com uma melhor precisão e exatidão. Neste trabalho foi desenvolvida uma câmara de ionização cilíndrica de 0.9 cm3, para monitorar as altas doses recebidas por amostras em tempo real, na posição de irradiação estática de um irradiador gama de 60Co. Os gases de nitrogênio e de argônio a pressão de 10exp5 Pa (1 bar) foram utilizados para preencherem a câmara de ionização e determinar uma configuração de trabalho apropriada, para o detector ser utilizado em medidas de altas doses. Cabos de isolação mineral foram soldados diretamente ao corpo da câmara de ionização, para a transmissão do sinal gerado pelo detector até a eletrônica associada, distante cerca de 20 m. O sinal obtido foi cerca de 100 vezes maior do que o ruído de fundo. Este sistema dosimétrico foi testado em um irradiador gama de categoria I e na posição de irradiação estática de um irradiador de grande porte, em que diferentes taxas de dose foram obtidas utilizando materiais absorvedores. Foi encontrada uma boa linearidade do detector entre a dose e a carga, independentemente das diferentes taxas de dose. As incertezas de todas as curvas ficaram abaixo dos +/- 5 %, valor de incerteza máxima recomendada para um sistema dosimétrico de rotina. A câmara de ionização desenvolvida se mostrou adequada para ser utilizada como um dosímetro em tempo real, independente da degradação do espectro causada pela absorção dos fótons da fonte de 60Co, pelo material em irradiação dinâmica. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0206 seconds