Spelling suggestions: "subject:"image processing, computer assisted"" "subject:"image processing, coomputer assisted""
81 |
Correlação de imagens metabólicas (PET 18F-FDG) com imagens de fluxo sanguíneo (PET 11C-PIB) em idosos com queixa de memória / Carneiro CG. Correlation between metabolic images (18F-FDG PET) and blood flow images (11C-PIB PET) in elderly patients with memory complaintsCarneiro, Camila de Godoi 10 May 2019 (has links)
Introdução: A tomografia por emissão de pósitrons (PET) permite a avaliação in vivo de alvos moleculares em doenças neurodegenerativas, como a doença de Alzheimer (DA). A deposição de placa Beta-amiloide pode ser avaliada por PET 11C-PIB, enquanto o PET 18F-FDG é utilizado para avaliar o metabolismo da glicose cerebral, que pode ser um indicador de lesão neuronal e disfunção sináptica. Além disso, a captação cerebral precoce de radiofármacos de PETamiloide pode determinar o fluxo sanguíneo cerebral regional. Mais estudos correlacionando a fase inicial de perfusão do 11C-PIB (11C-pPIB) e 18F-FDG ainda são necessários, considerando que o fluxo sanguíneo e o metabolismo da glicose cerebral são geralmente acoplados em repouso e durante as ativações neuronais. Objetivo: Avaliar se existe concordância diagnóstica e/ou topográfica entre a imagem na fase de perfusão do 11C-PIB (11C-pPIB), obtida entre 0 e 10 minutos, e a imagem metabólica de PET 18F-FDG através da quantificação por SPM (Statistical Parametric Mapping) e por análise visual, em sujeitos com DA e CCLa comparados aos controles idosos saudáveis. Métodos: CAPEPesq: Nº1.454.598. Noventa e três sujeitos foram alocados em três grupos de acordo com o diagnóstico clínico: doença de Alzheimer (DA - n = 27); Comprometimento Cognitivo Leve amnéstico (CCLa - n = 39); Controle idosos saudáveis (n = 27), estes foram submetidos a exames de imagens de RM ponderada em T1 e de PET/CT. A PET/CT 18F-FDG foi realizada 30 minutos após a injeção do radiofármaco e a PET/CT 11C-pPIB foi adquirida imediatamente após a injeção do radiofármaco, e os primeiros 10 minutos da aquisição foram considerados na análise. Imagens de PET foram corrigidas para efeito de volume parcial e as imagens foram espacialmente normalizadas utilizando um modelo anatômico personalizado da própria amostra (template), para análise por Mapa Estatístico Paramétrico (SPM8). A análise visual e individual foi realizada por dois médicos nucleares com experiência na área, cegos em relação à identificação das imagens, seus respectivos radiofármacos e diagnóstico clínico. Eles foram solicitados a fornecer um diagnóstico e indicar uma classificação com base na inspeção visual das imagens de 18F-FDG e 11CpPIB, e também na avaliação individual dos mapas-t de SPM (análise baseada em voxel comparando um único sujeito do grupo DA com um grupo de controle cognitivamente normal). Resultados e Discussão: Na análise por SPM, o 11CpPIB mostrou menor captação difusa cortical do que 18F-FDG. Na análise entre grupos, há uma diferença na captação de 11C-pPIB e 18F-FDG, o que é esperado, uma vez que a biodistribuição é uma propriedade particular de cada biomarcador de PET. Na comparação do grupo DA em relação ao grupo controle, os indivíduos com DA apresentaram diminuição da captação de 11C-pPIB nas regiões temporo-límbicas: amígdala e hipocampo (E = esquerdo) P = 0,006, amígdala e hipocampo (D = direito) P = 0,023; giro parahipocampal (E) P = 0,008 (D) P = 0,015; temporal superior (E) P = 0,012 (D) P = 0,015. No 18F-FDG, houve diminuição da captação no grupo DA comparado ao grupo controle nas seguintes regiões: córtex do cíngulo posterior (E) P = 0,028; pré-cuneus (E) P= 0,029; giro temporal médio (E) P = 0,039; giro temporal inferior (E) P = 0,044. Na comparação do grupo CCLa em relação ao grupo controle, os indivíduos com CCLa apresentaram diminuição da captação de 11C-pPIB na região do giro parahipocampal (E) P = 0,012. Na identificação visual, 100% das imagens PET 18F-FDG e 99% das imagens PET 11C-pPIB foram corretamente identificadas. Na análise visual e individual, foram observadas reduções na captação de 11CpPIB envolvendo a região temporal medial nos indivíduos com DA que não foi detectada pelo 18F-FDG. Isso poderia significar algum tipo de dissociação entre a perfusão e o metabolismo. Conclusão: Nossos achados sugerem que não há concordância diagnóstica e topográfica perfeita entre a imagem do metabolismo de glicose por PET com 18F-FDG e o padrão de perfusão cerebral usando o marcador PET 11C-PIB em certas estruturas cerebrais em idosos saudáveis, CCLa e pacientes com DA, na quantificação por SPM e na análise visual. Como um biomarcador duplo, a PET 11C-pPIB pode fornecer informações complementares sobre alterações fisiológicas no envelhecimento, e ajudar a elucidar e entender melhor a patologia das doenças relacionadas a memória / Introduction: Positron emission tomography (PET) allows in vivo evaluation of molecular targets in neurodegenerative diseases, such as Alzheimer´s Disease (AD). Beta-amyloid plaque deposition can be assessed by 11C-PIB PET while 18FFDG PET is used to assess cerebral glucose metabolism, which can be an indicator for neuronal injury and synaptic dysfunction. In addition, early cerebral uptake of PET-amyloid radiopharmaceuticals can determine regional cerebral blood flow. More studies correlating early-phase 11C-PIB (11C-pPIB) and 18F-FDG are still needed considering that blood flow and cerebral glucose metabolism are usually coupled at rest and during neuronal activations. The aim of this study is to evaluate topographic similarities and differences between cerebral perfusion images obtained with early 11C-PIB PET images and the metabolic images obtained with 18F-FDG PET. Methods: CAPEPesq: Nº1.454.598. Ninety-three subjects were allocated into three groups according to clinical diagnosis: Alzheimer\'s disease (AD, n=27); Mild Cognitive Impairment amnestic (aMCI, n=39); Elderly healthy control (n=27), they underwent T1-weighted MRI and PET/CT imaging. 18F-FDG PET/CT acquisition was performed 30 minutes after tracer injection and 11C-pPIB PET/CT was acquired immediately after the tracer injection and the first 10 minutes of the acquisition was considered in the analysis. PET images were corrected for partial volume effect and the images were spatially normalized using a custom anatomical template of the sample itself, for analysis by Statistical Parametric Mapping (SPM8). Visual and individual analysis were performed by two experient nuclear medicine physicians, blind in relation to the identification of the images, their respective radiopharmaceuticals and clinical diagnosis. They were asked to provide a diagnosis and to indicate their level of confidence on the basis of visual inspection of 18F-FDG and 11C-pPIB images, and also individual assessment of SPM t-maps (voxel-based analysis comparing a single subject of AD group to a cognitively normal control group). Results and Discussion: In the analysis by SPM, the 11C-pPIB showed lower cortical diffuse uptake than 18F-FDG. In the analysis between groups, there is a difference in 11CpPIB and 18F-FDG uptake, what is expected since biodistribution is a particular propriety of each PET tracer. The control group versus the AD group, individuals with AD presented a decreased 11C-pPIB uptake in the temporo-limbic regions: amygdala and hippocampal (L = left) P = 0.006; amygdala and hippocampal (R = right) P = 0.023; parahippocampal gyrus (L) P = 0.008 (R) P = 0.015; and superior temporal (L) P = 0.012 (R) P = 0.015. In the 18F-FDG, there was a decreased uptake in the AD group compared to the control group in the following regions: posterior cingulate cortex (L) P = 0.028; precuneus (L) P= 0.029; medial temporal gyrus (L) P = 0.039; and inferior temporal gyrus (L) P = 0.044. In the comparison of aMCI group versus the control group, individuals with aMCI presented a decreased 11C-pPIB uptake in the region: parahippocampal gyrus (L) P = 0.012. In the visual identification, 100% of 18F-FDG PET images and 99% of 11C-pPIB PET images were correctly recognized. In the visual and individual analysis, it was observed reductions in 11C-pPIB uptake involving medial temporal region in the AD subjects that was not detected by 18F-FDG.This could mean some kind of decoupling between perfusion and metabolism. Conclusion: Our findings suggest that there is no perfect diagnostic and topographical concordance between the imaging of 18F-FDG PET glucose and the cerebral perfusion pattern using the 11C-PIB PET marker in certain brain structures in healthy elderly, aMCI and patients suggestive of AD, quantification by SPM and visual analysis. As a double biomarker, 11C-PIB can provide complementary information on pathological aging of the brain, and it could help elucidate and better understand the pathology of memory-related diseases
|
82 |
Análises morfológica e dinâmica da coronária baseadas no processamento tridimensional de exames de ultrassonografia intravascular / Morphological and dynamic analysis of the coronary based on tridimensional image processing of intravascular ultrasound examinationMatsumoto, Monica Mitiko Soares 05 November 2010 (has links)
Na prática intervencionista, a ultrassonografia intravascular (USIV) é usada para se obter informações quantitativas e qualitativas do acometimento aterosclerótico, de forma complementar à angiografia. Esta tese teve como objetivos explorar a característica tomográfica do exame de USIV, bem como sua dinâmica dentro do ciclo cardíaco. Para isso, desenvolvemos técnicas de processamento de imagens médicas. Primeiramente, investigamos a reconstrução tridimensional da coronária baseando-nos apenas nas imagens de USIV, ou seja, sem a angiografia, como é feita a reconstrução atualmente. Na análise da dinâmica, fizemos um estudo para dispor volumes da coronária em diferentes fases do ciclo cardíaco de forma que estivessem alinhados espacialmente. Como consequência dos tratamentos propostos anteriormente, realizamos estudos sobre a quantificação de propriedades mecânicas dentro das condições oferecidas no intervalo de um ciclo cardíaco. As metodologias propostas foram aplicadas em simulações numéricas desenvolvidas neste trabalho e em exames reais. Obtivemos resultados compatíveis com os objetivos iniciais para reconstrução tridimensional da USIV em simulações numéricas. Na análise da dinâmica, a reconstrução de volumes em diferentes fases do ciclo e o alinhamento espacial possibilitaram a quantificação da variação setorial de volume da luz do vaso durante o ciclo cardíaco / In percutaneous coronary interventions, intravascular ultrasound (IVUS) examination is used to retrieve quantitative and qualitative information about the atherosclerotic plaque progression, complementary to angiography examination. This thesis has as objectives to explore the tomographic characteristic of the IVUS examination, as well as its dynamics within a cardiac cycle. For that purpose, medical image processing techniques were developed. Firstly, we have investigated how to reconstruct the tridimensional coronary based only on IVUS images, that is, without angiography, as it is done nowadays. Regarding dynamic analysis, we have studied models to build volumes of the coronary in distinct phases of the cardiac cycle in a spatial aligned way. Conversantly, as a consequence of the previous image processing methods, we have studied the quantification of mechanical properties of the vessel wall within a cardiac cycle. The methodologies proposed were applied in numeric phantoms developed in this work and also in real IVUS examinations. As result, tridimensional reconstruction was successful in the numeric phantom approach. In dynamics analysis, the reconstruction in distinct cardiac phases and volumes spatial alignment enabled the quantification of lumen volume variation during the cardiac cycle
|
83 |
Análises morfológica e dinâmica da coronária baseadas no processamento tridimensional de exames de ultrassonografia intravascular / Morphological and dynamic analysis of the coronary based on tridimensional image processing of intravascular ultrasound examinationMonica Mitiko Soares Matsumoto 05 November 2010 (has links)
Na prática intervencionista, a ultrassonografia intravascular (USIV) é usada para se obter informações quantitativas e qualitativas do acometimento aterosclerótico, de forma complementar à angiografia. Esta tese teve como objetivos explorar a característica tomográfica do exame de USIV, bem como sua dinâmica dentro do ciclo cardíaco. Para isso, desenvolvemos técnicas de processamento de imagens médicas. Primeiramente, investigamos a reconstrução tridimensional da coronária baseando-nos apenas nas imagens de USIV, ou seja, sem a angiografia, como é feita a reconstrução atualmente. Na análise da dinâmica, fizemos um estudo para dispor volumes da coronária em diferentes fases do ciclo cardíaco de forma que estivessem alinhados espacialmente. Como consequência dos tratamentos propostos anteriormente, realizamos estudos sobre a quantificação de propriedades mecânicas dentro das condições oferecidas no intervalo de um ciclo cardíaco. As metodologias propostas foram aplicadas em simulações numéricas desenvolvidas neste trabalho e em exames reais. Obtivemos resultados compatíveis com os objetivos iniciais para reconstrução tridimensional da USIV em simulações numéricas. Na análise da dinâmica, a reconstrução de volumes em diferentes fases do ciclo e o alinhamento espacial possibilitaram a quantificação da variação setorial de volume da luz do vaso durante o ciclo cardíaco / In percutaneous coronary interventions, intravascular ultrasound (IVUS) examination is used to retrieve quantitative and qualitative information about the atherosclerotic plaque progression, complementary to angiography examination. This thesis has as objectives to explore the tomographic characteristic of the IVUS examination, as well as its dynamics within a cardiac cycle. For that purpose, medical image processing techniques were developed. Firstly, we have investigated how to reconstruct the tridimensional coronary based only on IVUS images, that is, without angiography, as it is done nowadays. Regarding dynamic analysis, we have studied models to build volumes of the coronary in distinct phases of the cardiac cycle in a spatial aligned way. Conversantly, as a consequence of the previous image processing methods, we have studied the quantification of mechanical properties of the vessel wall within a cardiac cycle. The methodologies proposed were applied in numeric phantoms developed in this work and also in real IVUS examinations. As result, tridimensional reconstruction was successful in the numeric phantom approach. In dynamics analysis, the reconstruction in distinct cardiac phases and volumes spatial alignment enabled the quantification of lumen volume variation during the cardiac cycle
|
Page generated in 0.1397 seconds