• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 9
  • Tagged with
  • 26
  • 26
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Localização de danos em estruturas anisotrópicas com a utilização de Ondas Guiadas / Damage localization in anisotropic structures using Guided Waves

Rosa, Vinicius Augusto Matheus [UNESP] 25 July 2016 (has links)
Submitted by Vinicius Augusto Matheus Rosa null (vinicius91027@aluno.feis.unesp.br) on 2016-09-25T14:21:09Z No. of bitstreams: 1 Vinicius Rosa-PDF_FINAL.pdf: 3807538 bytes, checksum: d62638a8fa9c1ae27ad1e162a2d1d068 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-09-27T14:30:43Z (GMT) No. of bitstreams: 1 rosa_vam_me_ilha.pdf: 3807538 bytes, checksum: d62638a8fa9c1ae27ad1e162a2d1d068 (MD5) / Made available in DSpace on 2016-09-27T14:30:43Z (GMT). No. of bitstreams: 1 rosa_vam_me_ilha.pdf: 3807538 bytes, checksum: d62638a8fa9c1ae27ad1e162a2d1d068 (MD5) Previous issue date: 2016-07-25 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho analisa um método de Monitoramento da Integridade de Estruturas (SHM, do inglês Structural Health Monitoring) usando funções erro calculadas a partir de ondas guiadas que são refletidas nos danos. Este método foi primeiro testado por Gorgin et al em 2014, que apresentou o método aplicado para materiais isotrópicos. A abordagem é testada experimentalmente em materiais anisotrópicos e isotrópicos. O sinal da estrutura intacta, que será referido como baseline e o sinal atual para cada caminho de propagação (entre dois transdutores PZT) são medidos e a energia do sinal de dispersão para cada caminho é calculada em um dado intervalo. Assumindo que existe dano no ponto avaliado, a onda irá refletir neste ponto e se propagar até o sensor. A técnica é baseada no tempo de propagação (time-of-flight) entre o atuador (primeiro transdutor PZT) até o ponto avaliado mais o tempo de propagação do ponto avaliado até o sensor (segundo transdutor PZT, em uma configuração pitch-catch) para cada ponto da estrutura. A velocidade de propagação em materiais anisotrópicos é dependente da direção de propagação. Isto não acontece em materiais isotrópicos, onde a velocidade de propagação é constante e não é dependente da direção de propagação. No caso de materiais anisotrópicos as velocidades de propagação para diferentes direções foram calculadas experimentalmente e incorporadas ao algoritmo para calcular o time-of-flight corretamente para todos os pontos da estrutura. A energia do sinal de dispersão é calculada em um intervalo baseado no time-of-flight de cada posição analisada. A estimativa da localização do dano é definida através de uma função erro resultante para cada ponto da área monitorada. Como a função erro é baseada na interferência do dano na propagação de ondas guiadas, o maior valor da função erro mostra uma menor probabilidade de dano naquela posição. Uma imagem é gerada com um valor da função erro para cada ponto avaliado da estrutura. A função erro compara valores de energia nos devidos intervalos para cada par de transdutores PZT. O método foi aplicado para várias frequências de excitação, afim de obter-se um resultado melhor. / This work highlights a method for Structural Health Monitoring using error functions computed from guided waves reflected from damage. This method was first tested by Gorgin et al in 2014, who presented the method for isotropic plates. The approach is experimentally tested on anisotropic and isotropic specimens such as composite and aluminum plates, respectively. The baseline and test signals of each sensing path (between two PZT transducers) are measured and the energy of the scatter signal for each path is calculated in a given range. The structure is meshed and the middle point of each component is considered in the calculations. Assuming that there is damage in the evaluated position, the wave will reflect at this point and propagate to the next transducer. The technique is based in the time-of-flight between the actuator (first PZT transducer) and the evaluated point plus the time-of-flight of the evaluated point to the sensor (second PZT transducer, for a pitch-catch configuration) for each mesh component of the structure. The wave speeds in anisotropic specimens are propagation direction dependent. It does not happen in isotropic materials, which have the wave speed constant and non-dependent of the propagation direction. In the case of anisotropic materials, the wave speed for different angles were experimentally computed and incorporated in the algorithm in order to calculate the proper time-of-flight. The energy of the scatter signal is computed in a time range based on the time of flight of each analyzed position. The estimated damage location is defined through a resultant error function for each evaluated point in the monitored area. As the error function is based on the interference of the damage in the propagation of guided waves, the higher value of the error implies the less likelihood of damage in that position. An image is generated with an error value for each mesh position in the plate. This error function compares the energy in the given ranges for each pair of transducers. In addition, several frequencies were tested and the results for each one were combined in order to get a better result. / CNPq: 160328/2014-4
22

Sistema de avaliação de qualidade de imagem em radiologia digital odontologica / Image quality evaluation system for dental digital radiology

Leão, Tiago Freire Carneiro 13 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T16:14:16Z (GMT). No. of bitstreams: 1 Leao_TiagoFreireCarneiro_M.pdf: 2505362 bytes, checksum: 6d6b07198f62fd7206b28e629cc5ba41 (MD5) Previous issue date: 2009 / Resumo: Novas tecnologias e sistemas de detecção de radiação para a geração de imagens radiográficas odontológicas vêm sendo disponibilizados como alternativa aos filmes radiográficos. Sistemas baseados em tecnologia do tipo PSPL parecem superar algumas das restrições encontradas nos sistemas baseados em tecnologia CCD, tais como volume do detector, cabos de conexão, tamanho limitado da imagem e limitação da latitude. É importante que seja possível comparar sistemas de imagem concorrentes (diferentes tecnologias ou diferentes fabricantes com mesma tecnologia), utilizando ferramentas e protocolos de controle e certificação de qualidade. Foi desenvolvido um pacote computacional e um conjunto de simuladores e foi realizada a análise de dois sistemas comerciais baseados na tecnologia PSPL, de forma a validar o sistema desenvolvido. O programa desenvolvido permite obter e analisar: curva sensitométrica, função de transferência de modulação (MTF), densidade espectral de potência (NPS), quanta equivalente de ruído (NEQ) e eficiência na detecção de quanta (DQE). Os resultados mostraram que o pacote computacional e o conjunto de simuladores permitem realizar o controle de qualidade de sistemas de radiografia digital odontológica de maneira quantitativa e objetiva, facilitando a análise comparativa entre diferentes sistemas comerciais. Palavras-chave: Radiologia digital odontológica, controle de qualidade em radiodiagnóstico, curva sensitométrica, detecção equivalente de quanta, função de transferência de modulação, densidade espectral de ruído, quanta equivalente de ruído. / Abstract: New systems and technologies for radiation detection intended for dental radiology have become available as an alternative to dental radiographic film. Systems based on PSPL technology seems to overcome some of the restrictions of systems based on CCD technology such as the bulky detector, connecting wire, limited image size and limited exposure latitude. It is important that competing imaging systems can be compared (different technologies or different manufacturers of the same technology) by means of quality control tools and quality certification protocols. A software package and a set of specific phantoms were developed and the analyses of two competing PSPL systems were conducted to validate the developed system. The software allows the user to obtain and analyze: the characteristic curve, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). The results have shown that the developed software and phantom set allow quality control of digital dental radiology systems in a very objective and quantitative way, facilitating comparative analysis of competing commercial systems. Keywords: Digital dental radiology, quality assurance in radiodiagnostic, characteristic curve, detective quantum efficiency, modulation transfer function, noise power spectrum, noise equivalent quanta. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
23

Tamanduá-bandeira (Myrmecophaga tridactyla): Anatomia aplicada a radiografia e tomografia do aparato hióide e coluna vertebral / Giant anteater (Myrmecophaga tridactyla Linnaeus, 1758): Anatomy applied to radriography and tomography of hyoid apparatus and vertebral column

BOGOEVICH, Andria de Melo 20 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:07:36Z (GMT). No. of bitstreams: 1 Dissertacao Andria Bogoevich.pdf: 1442294 bytes, checksum: ab1d215a31c38e78aab1e4a97a85e070 (MD5) Previous issue date: 2011-09-20 / The giant anteater is a peculiar mammal which during its evolutionary process, has undergone several body changes due to their insect-base diet. Although it is distributed throughout the country, it is a species typical of the Cerrado, which is threatened with extinction. In the last decade there has been an improvement in access to methods of imaging diagnostic in veterinary medicine, the availability of modern and faster techniques. These techniques have revolutionized the ability to explore non-invasive body parts. For a better interpretation of these techniques, knowledge of regional anatomy is required. However, data on radiographic anatomy of giant anteaters have not been reported. The aim of this study is to characterize and describe the outline contour of the spine bone and the hyoid bone of the giant anteater using radiographic and computed tomography images. Seven giant anteaters at various ages, from IBAMA, were used for radiographic examination and two adults for CT. The spine along its entire length and the hyoid elements were evaluated in all animals using both imaging techniques. Radiography provided satisfactory images of the bony contours and location of these structures, although the CT was more efficient to provide images with less overlap between them, allowing details identification such as the Xenarthrous process in the lumbar vertebrae, characteristic of the species, and the visualization of the V-bone in the hyoid apparatus. / O tamanduá-bandeira é um mamífero peculiar que durante o processo evolutivo sofreu diversas adaptações em seu organismo devido a sua dieta composta de insetos. Embora distribuída por todo o território nacional, é uma espécie típica do cerrado que se encontra ameaçada de extinção. Na última década houve uma melhora no acesso aos métodos de diagnóstico por imagem na medicina veterinária, com a disponibilidade de técnicas mais modernas e velozes. Essas técnicas revolucionaram a habilidade de explorar de forma não-invasiva as partes do corpo. Para uma boa interpretação dessas técnicas é necessário o conhecimento anatômico regional. Apesar de sua ampla distribuição e de sua importância, dados sobre anatomia radiográfica do tamanduá-bandeira ainda não foram relatados na literatura. O objetivo desse trabalho é caracterizar e descrever o contorno ósseo da coluna vertebral e do osso hióide do tamanduá-bandeira utilizando para isso imagens radiográficas e tomográficas. Foram utilizados sete tamanduás-bandeiras de variadas idades, provenientes do IBAMA para os exames radiográficos e dois adultos para os tomográficos. A coluna vertebral em toda sua extensão e os elementos hióideos foram avaliados em todos os animais através de ambos as técnicas de imagem. A radiografia forneceu imagens satisfatórias sobre os contornos ósseos e a localização dessas estruturas, entretanto a tomografia se mostrou mais eficiente ao fornecer imagens com menor sobreposição entre as mesmas, possibilitando a identificação de detalhes ósseos como o processo xenarthro nas vértebras lombares, característico da espécie, e no aparato hióide a visualização do formato em V do basitireóide.
24

Desenvolvimento de ferramenta computacional para o pré-diagnóstico de câncer de pele / Development of a computational tool for skin cancer pre-diagnosis

Gilvan Sampaio Santos 28 August 2008 (has links)
Um dos mais freqüentes tumores existentes é o câncer de pele. Quando identificado precocemente este tipo de câncer apresenta altos percentuais de cura. Para isso é necessário o reconhecimento de suas características. As características analisadas fundamentam-se em identificadores como: Assimetria da lesão (A); Irregularidade das Bordas (B); Cor (C) e Diâmetro (D). Neste trabalho utiliza-se como ferramenta o Processamento de Imagens digitais para o pré-diagnóstico do câncer de pele. / Skin cancer is one of the most frequent tumors . When early diagnosticated this kind of cancer reachs high percentage of cure. But the identification of its characteristics is necessary. The characteristics to be analised are: Asymmetry (A); Irregularity border (B); Color (C) and diameter (D). The present work uses as tool for first diagnostic of skin cancer the digital images processing.
25

Desenvolvimento de ferramenta computacional para o pré-diagnóstico de câncer de pele / Development of a computational tool for skin cancer pre-diagnosis

Gilvan Sampaio Santos 28 August 2008 (has links)
Um dos mais freqüentes tumores existentes é o câncer de pele. Quando identificado precocemente este tipo de câncer apresenta altos percentuais de cura. Para isso é necessário o reconhecimento de suas características. As características analisadas fundamentam-se em identificadores como: Assimetria da lesão (A); Irregularidade das Bordas (B); Cor (C) e Diâmetro (D). Neste trabalho utiliza-se como ferramenta o Processamento de Imagens digitais para o pré-diagnóstico do câncer de pele. / Skin cancer is one of the most frequent tumors . When early diagnosticated this kind of cancer reachs high percentage of cure. But the identification of its characteristics is necessary. The characteristics to be analised are: Asymmetry (A); Irregularity border (B); Color (C) and diameter (D). The present work uses as tool for first diagnostic of skin cancer the digital images processing.
26

The development of CT urography for investigating haematuria

Cowan, Nigel Christopher January 2013 (has links)
This thesis addresses the three principal questions concerning the development of CT urography for investigating haematuria and each question is the subject of a separate chapter. The questions are: What is the reasoning behind using CT urography? What is the optimum diagnostic strategy using CT urography? What are the problems with using CT urography and how may solutions be provided? Haematuria can signify serious disease such as urinary tract stones, renal cell cancer, upper tract urothelial cancer (UTUC) and bladder cancer (BCa). CT urography is defined as contrast enhanced CT examination of kidneys, ureters and bladder. The technique used here includes unenhanced, nephrographic and excretory-phases for optimized diagnosis of stones, renal masses and urothelial cancer respectively. The reasoning behind using excretory-phase CT urography for investigating haematuria is based on results showing its high diagnostic accuracy for UTUC and BCa. Patients with haematuria are classified as low risk or high risk for UTUC and BCa, by a risk score, determined by the presence/absence of risk factors: age > 50 years, visible or nonvisible haematuria, history of smoking and occupational exposure. The optimum diagnostic strategy for patients at high risk for urothelial cancer, uses CT urography as a replacement test for ultrasonography and intravenous urography and as a triage test for flexible and rigid cystoscopy, resulting in earlier diagnosis and potentially improving prognosis. For patients at low risk, ultrasonography, unenhanced and nephrographic-phase CT urography are proposed as initial imaging tests. Problems with using CT urography include false positive results for UTUC, which are eliminated by retrograde ureteropyelography-guided biopsy, an innovative technique, for histopathological confirmation of diagnosis. Recommendations for the NHS and possible future developments are discussed. CT urography, including excretory-phase imaging, is recommended as the initial diagnostic imaging test before cystoscopy for patients with haematuria at high risk for urothelial cancer.

Page generated in 0.0643 seconds