• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 6
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimization of novel developments in Positron Emission Tomography (PET) imaging

January 2012 (has links)
Positron Emission Tomography (PET) is a widely used imaging modality for diagnosing patients with cancer. Recently, there have been three novel developments in PET imaging aiming to increase PET image quality and quantification. This thesis focuses on the optimization of PET image quality on these three developments. The first development is the fully 3D PET data acquisition and reconstruction. 3D Acquisitions are not constrained in collecting events in single 2D planes and can span across different planes. 3D acquisition provides better detection since it can accept more events. Also it can result in lower radiation dose to the patient and shorter imaging times. With the application of 3D acquisition, a fully 3D iterative reconstruction algorithm was also developed. The aim of the first project in this thesis is to evaluate the PET image and raw data quality when this fully 3D iterative reconstruction algorithm is applied. The second development in PET imaging is the time-of-flight (TOF) PET data acquisition and reconstruction. TOF imaging has the ability to measure the difference between the detection times, thus localize the event location more accurately to increase the image quality. The second project in this thesis focuses on optimizing the TOF reconstruction parameters on a newly developed TOF PET scanner. Then the improvement of TOF information on image quality is assessed using the derived optimal parameters. Finally the effect of scan duration is evaluated to determine whether similar image quality could be obtained between TOF and non-TOF while using less scan time for TOF. The third development is the interest in building PET / magnetic resonance (MR) multi-modality scanner. MR imaging has the ability to show high soft tissue contrast and can assess physiological processes, which cannot be achieved on PET images. One problem in developing PET/MR system is that it is not possible with current MR acquisition schemes to translate the MR image into an attenuation map to correct for PET attenuations. The third project in this thesis proposed and assessed an approach for the attenuation correction of PET data in potential PET/MR systems to improve PET image quality and quantification.
2

Evaluating a multi-hospital quality improvement strategy to implement clinical guidelines for radiographic contrast agents

Hernandez, John B. January 1998 (has links)
Thesis (Ph. D.)--RAND Graduate School, 1998. / "RGSD-146"--Cover p. 4. Includes bibliographical references (p. 105-111).
3

Evaluating a multi-hospital quality improvement strategy to implement clinical guidelines for radiographic contrast agents

Hernandez, John B. January 1998 (has links)
Thesis (Ph. D.)--RAND Graduate School, 1998. / "RGSD-146"--Cover p. 4. Includes bibliographical references (p. 105-111).
4

Criteria to Evaluate the Quality of Pavement Camera Systems in Automated Evaluation Vehicles

Sokolic, Iván 17 July 2003 (has links)
The use of high technology in common daily tasks is boarding all areas of civil engineering; pavement evaluation is not the exception. Accordingly, current pavement imaging systems have been able to collect images at highway speeds and with the use of proper software, this digital information can be translated into pavement distress reports in which all distresses are classified and presented by their type, extent, severity, and location. However, a number of issues regarding the quality of pavement images and the appropriate conditions to acquire them, remain to be addressed. These issues surfaced during the development of a pavement evaluation vehicle for the Florida Department of Transportation (FDOT). The work involved in this thesis proposes basic criteria to evaluate the performance of pavement imaging systems. Mainly four parameters (1) spatial resolution, (2) brightness resolution, (3) optical distortion, and (4) signal to noise ratio, have been identified to assess the quality of a pavement imaging system. First, each of the four parameters is studied in detail in USF's Visual Imaging Laboratory to formulate relevant criteria that can be used to evaluate imaging systems. Then, the developed criteria are used to evaluate the FDOT Survey Vehicle's pavement imaging system. The evaluation speed does not seem to have any significant influence on the spatial resolution, brightness resolution and signal to noise ratio. Little or no optical distortion was observed on the images on wheel paths. Limitations of the imaging system were also determined in terms of the brightness resolution and noise. The conclusions drawn from this study can be used to (1) enhance pavement imaging systems and (2) setup appropriate guidelines to perform automated distress surveys, under varying lighting conditions and speeds to obtain good quality images.
5

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Marques, Paulo Mazzoncini de Azevedo 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.
6

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Paulo Mazzoncini de Azevedo Marques 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.

Page generated in 0.0835 seconds