Spelling suggestions: "subject:"impedance (electricity)"" "subject:"impedance (delectricity)""
41 |
Model development via delay extraction for the time-domain simulation of lossy transmission lines /Blevins, Chris. January 1900 (has links)
Thesis (M.S.)--Oregon State University, 2010. / Printout. Includes bibliographical references (leaves 107-110). Also available on the World Wide Web.
|
42 |
Sensor químico baseado em microponte de impedância = Chemical sensor based on impedance microbridge / Chemical sensor based on impedance microbridgeRibeiro, Luiz Eduardo Bento 21 August 2018 (has links)
Orientador: Fabiano Fruett / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T04:02:00Z (GMT). No. of bitstreams: 1
Ribeiro_LuizEduardoBento_M.pdf: 4022818 bytes, checksum: d2a40b9cee4f59bc80ec0b09a97c31a8 (MD5)
Previous issue date: 2012 / Resumo: A integração de sistemas microeletrônicos em lab-on-a-chip está sendo cada vez mais necessária para concretizar novas aplicações dentro do emergente campo da microfluídica. Tanto na química quanto na bioquímica e até mesmo na medicina e bioengenharia, a microfluídica evolui conquistando um espaço crescente. Entretanto, desafios tecnológicos residem na sua complexa fabricação e integração com sistemas eletrônicos. Neste trabalho, foi desenvolvido um sistema sensor que emprega métodos de fabricação compatíveis tanto com a microeletrônica quanto com a microfluídica. Este sistema sensor é baseado em uma microponte de impedância composta por quatro capacitores interdigitados. Neste sistema, o fluido, guiado por um canal ou armazenado em um reservatório fabricado em polidimetilsiloxano (PDMS), passa sobre a microponte enquanto um termistor, fabricado no mesmo substrato, permite monitorar a temperatura do sistema durante a medida. A microponte é formada de eletrodos interdigitados arranjados de forma a permitir a utilização de um circuito eletrônico de condicionamento que pode ser construído bem próximo do elemento sensor. O trabalho foi validado comparando-se a função de transferência experimental do sensor, usando como analito a mistura etanol-água, com a função de transferência teórica obtida através de simulação baseada em elementos finitos. Identificamos a importância da deposição de um filme fino de boa qualidade para a proteção dos eletrodos de referência e sua influência na função de transferência experimental. Ainda, devido à utilização de materiais inertes como ouro, vidro e PDMS, o sistema sensor, com alguns ajustes, pode ser empregado para outras aplicações: desde o monitoramento da pureza e concentração de líquidos até a caracterização de filmes finos sensíveis a patógenos e fármacos / Abstract: The integration of microelectronic systems in lab-on-a-chip is being increasingly required to implement new applications on the emerging field of microfluidics. Both in chemistry and biochemistry, and even in medicine and bioengineering, microfluidics evolves gaining a growing space. However, technological challenges lie in its complex manufacturing and integration with electronic systems. In this work, we developed a sensor system that employs both fabrication methods compatible with microelectronics and with microfluidics. This sensor system is based on an impedance microbridge composed of four interdigitated capacitors. In this system, the fluid which is guided by a channel or is stored in a reservoir made of polydimethylsiloxane (PDMS), passes over the microbridge while a thermistor fabricated on the same substrate allows monitoring of the system temperature during the measurement. The microbridge is made of interdigitated electrodes arranged so as to allow the use of an electronic conditioning circuit that can be built very close to the sensor element. The study was validated by comparing experimental transfer function of the sensor, using the ethanol-water mixture as analyte, with the theoretical transfer function obtained by simulation based on finite element method. We identified the importance of depositing a good quality thin film for the protection of reference electrodes and its influence on experimental transfer function. Also, due to the use of inert materials such as gold, glass and PDMS, the sensor system, with some adjustments, can be used for other applications: from monitoring of the concentration and purity of liquid to the characterization of thin films sensitive to drugs and pathogenic agents / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
|
43 |
Estudo das propriedades dielétricas e de bloqueio das monocamadas automontadas /Benites, Tiago Azevedo. January 2013 (has links)
Orientador: Paulo Roberto Bueno / Coorientador: Márcio de Sousa Góes / Banca: Antonio Pupim / Banca: Ernesto Chavez / Resumo: O estudo das propriedades dielétricas das monocamadas automontadas de alcanotióis sobre o ouro (SAMs) é importante no campo da biotecnologia, já que essas camadas proporcionam uma estrutura fundamental na construção dos eletrodos quimicamente modificados, com sua principal aplicação na confecção dos biossensores. A análise das propriedades de bloqueio pelas SAMs é frequentemente feita por meio de técnicas eletroquímicas e de resposta em frequência, pois são extremamente eficazes no entendimento das características físico-químicas interfaciais de modificação desses filmes, além de apresentarem praticidade e velocidade de realização. Uma forma bastante apropriada de analisar a capacidade dielétrica das SAMs é quantificando a velocidade de transferência eletrônica frente a uma espécie eletroativa. Nesse trabalho foram caracterizadas monocamadas de diferentes espessuras em um meio com espécie eletroativa em concentrações variadas, a partir do cálculo da constante de transferência heterogênea de elétrons, feitas pelas metodologias propostas por diferentes autores e por uma metodologia inédita que será detalhada no corpo do trabalho / Abstract: The study of the dielectric properties of self-assembled monolayers of alkanethiols on gold (SAMs) is of paramount importance to biotechnology, as these layers provide a fundamental structure in the construction of chemically modified electrodes, with its main application in fabrication of biosensors. The analysis of the blocking properties of SAMs is often done by electroanalytical techniques and frequency response, as they are extremely effective in understanding the physico-chemical interfacial modification of these films, and offer convenience and speed of execution. A very appropriate manner of evaluating the blocking ability of SAMs is quantifying dielectric constant and the heterogeneous electron transfer rate across from one electroactive species in solution. In this study monolayers of different thicknesses were characterized in a medium with electroactive species in different concentrations to calculate of the heterogeneous electron transfer constant by classical methods which were compared with a new methodology detailed in the present work / Mestre
|
44 |
Avaliação experimental de um sistema não linear para extração de energia através de vibrações utilizando material piezelétrico /Carvalho, Felipe Carmo. January 2014 (has links)
Orientador: Vicente Lopes Junior / Co-orientador: Samuel da Silva / Banca: Joao Antonio Pereira / Banca: Milton Dias Junior / Resumo: Afim de suprir a necessidade por fontes alternativas de energia para a alimentação de sistemas microeletrônicos autônomos, os estudos têm se voltado para a utilização de materiais piezelétricos para a transformação de energia derivadas de vibrações mecânicas em energia elétrica. Como a potência fornecida pelas vigas com materiais piezelétricos é pequena e, geralmente, insuficientes para alimentar dispositivos eletrônico de forma autônoma, técnicas de extração, conversão e armazenamento de energia são utilizadas para otimizar a energia final acumulada. Neste sentido, este trabalho tem por objetivo a otimização de um sistema extrator de energia através de vibrações utilizando material piezelétrico, maximizando a potência extraída e melhorando o rendimento do sistema. Para isto, foram analisadas condições de linearidade e não linearidade no sistema e os respectivos circuitos conversores foram projetados e testados experimentalmente. A melhor configuração eletromecânica para extração de energia, o sistema será utilizada para alimentar um sistema autônomo. Foram projetados dois sistemas de monitoramentos com consumo de energia diferentes, para avaliar as limitações e potencialidades da proposta de sistema para extração de fontes alternativas de energia elétrica / Abstract: In order to meet the need for alternative energy sources to power autonomous microelectronic systems, studies have focused on the use of piezoelectric materials to transform energy derived from mechanical vibrations into electrical energy. Once the power delivered by the cantilever beams with piezoelectric materials are insufficient to power electronic devices autonomously, extraction techniques, conversion and energy storage was used to optimize the final accumulated energy. Considering that, this work aims at the optimization of an extractor system energy through vibrations using piezoelectric material, maximizing the power extracted and improving system performance. To this end, conditions of linearity and non-linearity in the mechanical system, as well as designed and tested converter circuits were analyzed. The best setup for electromechanical energy extraction, was used to feed an autonomous system. Two different power consumption-monitoring systems were designed to assess the limitation and potentialities of the proposed alternative for energy harvesting / Mestre
|
45 |
Estudo comparativo de técnicas de medição e aquisição de sinais de transdutores piezelétricos para detecção de dano baseada na impedância eletromecânica /Budoya, Danilo Ecidir. January 2018 (has links)
Orientador: Fabricio Guimarães Baptista / Banca: Fernando de Souza Campos / Banca: Mário Anderson de Oliveira / Resumo: Sistemas de monitoramento de integridade estrutural (SHM - Structural Health Monitoring) são científica e economicamente relevantes como métodos de detecção de danos estruturais em diversos tipos de estruturas, aumentando assim a segurança e reduzindo os custos de manutenção. Entre os vários princípios de detecção de danos, o método da impedância eletromecânica (E/M) baseia-se na medição da impedância elétrica do transdutor piezelétrico fixado à estrutura monitorada. Aqui, a exatidão e precisão do sistema de medição são fundamentais para o diagnóstico correto da estrutura. Portanto, essa dissertação apresenta uma análise comparativa de duas técnicas de medição de impedância para detecção de danos que são tipicamente utilizadas em analisadores de impedância comerciais e em outros sistemas de medição alternativos: medições em estado transitório utilizando um sinal de excitação de varredura e medições em estado estacionário utilizando um sinal senoidal puro para cada frequência de excitação. Os testes foram realizados com cargas resistivas e capacitivas de valores nominais 100 Ω e 10 nF, respectivamente, e com um transdutor piezelétrico fixado em uma barra de alumínio que representa uma estrutura monitorada. As duas técnicas foram comparadas com base na exatidão, precisão, sensibilidade à danos e tempo necessário para as medições. Os resultados destacam as características importantes de cada técnica, as quais devem ser consideradas para o desenvolvimento de sistemas de SHM basea... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Structural health monitoring (SHM) systems are scientifically and economically relevant as methods of detecting structural damage to various types of structures, thus increasing safety and reducing maintenance costs. Among the various principles of damage detection, the electromechanical impedance (EMI) method is based on the electrical impedance measurement of piezoelectric transducers attached to the monitored structure. Here, the accuracy and precision of the measurement system are fundamental for the correct diagnosis of the structure. Therefore, this dissertation presents a comparative analysis of two impedance measurement techniques for damage detection that are typically used in commercial impedance analyzers and other alternative measurement systems: transient-state measurements using a sweep excitation signal and steady-state measurements using a pure sinusoidal signal for each excitation frequency. Tests were performed with resistive and capacitive loads with nominal values of 100 Ω e 10 nF, respectively, and a piezoelectric transducer fixed to an aluminum bar representing a monitored structure. The two techniques were compared based on the accuracy, precision, sensibility to damage and time required for the measurements. The results highlight the important features of each technique, which should be considered for the development of impedance-based SHM systems and the correct diagnosis of monitored structures. / Mestre
|
46 |
Control of penetration in gas-tungsten-arc welding : a puddle impedance approachZacksenhouse, Miriam January 1982 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1982. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING / Includes bibliographical references. / by Miriam Zacksenhouse. / M.S.
|
47 |
Surface impedance of normal and superconductors at 24,000 megacycles per secondJanuary 1949 (has links)
E. Maxwell, P.M. Marcus, J.C. Slater. / "This paper is based on a thesis submitted in partial fulfillment of the Degree of Doctor of Philosophy at M.I.T." "May 2, 1949." / Bibliography: p. 55. / Army Signal Corps Contract No. W36-039-sc-32037 Project No. 102B Dept. of the Army Project No. 3-99-10-022
|
48 |
The surface impedance of metals at 24,000 Mc/secJanuary 1949 (has links)
[by] W.B. Nowak. / "May 27, 1949." / Bibliography: p. [146]. / Army Signal Corps Contract No. W-36-039 sc-32037, Project no. 102B. Dept. of the Army Project No. 3-99-10-022.
|
49 |
Correlation of PDN impedance with jitter and voltage margin in high speed channelsLaddha, Vishal 19 November 2008 (has links)
Jitter and noise on package and printed circuit board interconnects are limiting factors in the performance of high speed digital channels. The simultaneous switching noise (SSN) induced by the return path discontinuities (RPDs) is a major source of noise and jitter on the signal interconnects of these channels. Therefore, optimal design of the power delivery network (PDN) is required to reduce SSN induced noise and jitter and improve the performance of high speed channels.
The design of PDN is done in frequency domain whereas jitter and noise are time domain events. As a result, multiple iterations between frequency domain design of PDN and time domain analysis of noise and jitter are required before a design is taped out.
A new methodology to correlate PDN impedance with jitter and voltage margin is presented in this thesis. Using this methodology, it would be possible to estimate jitter and noise from the PDN impedance and reduce the iterations involved in freezing the PDN design.
The SSN induced at a given RPD is proportional to the PDN impedance at that RPD. As a result, the jitter and the noise can be correlated to the PDN impedance. The PDN impedance is a function of frequency and has alternate local minima and local maxima at resonances and anti-resonances respectively. The anti-resonances in the PDN impedance at the RPD cause significant increase in the insertion loss of signal whose return current is disrupted at that RPD. The increase in the insertion loss attenuates significant harmonics of the signal degrading its rise/fall times and voltage levels. This results in
reduction of timing and voltage margins of the signal. Thus, based on the insertion loss profile and harmonic content of the signal, an estimate of jitter and noise on the signal can be made. Passive test vehicles consisting of microstrips with RPDs have been designed and fabricated to demonstrate the proof of concept through both simulations and measurements.
Suitable placement of decoupling capacitors is suggested to reduce the PDN impedance below the target impedance and to minimize coupling between two noise ports on the PDN. Genetic algorithm to optimize the selection and placement of decoupling capacitors has been implemented. The efficacy of the algorithm has been demonstrated by testing it on a power delivery networks consisting of a simple power/ground plane pair.
|
50 |
Predicting generator coupling using power system impedance matricesSayler, Kent Alexander, Halpin, S. Mark, January 2006 (has links) (PDF)
Thesis(M.S.)--Auburn University, 2006. / Abstract. Vita. Includes bibliographic references (p.43).
|
Page generated in 0.0576 seconds