• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 8
  • 8
  • 7
  • 7
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo de técnicas de medição e aquisição de sinais de transdutores piezelétricos para detecção de dano baseada na impedância eletromecânica /

Budoya, Danilo Ecidir. January 2018 (has links)
Orientador: Fabricio Guimarães Baptista / Banca: Fernando de Souza Campos / Banca: Mário Anderson de Oliveira / Resumo: Sistemas de monitoramento de integridade estrutural (SHM - Structural Health Monitoring) são científica e economicamente relevantes como métodos de detecção de danos estruturais em diversos tipos de estruturas, aumentando assim a segurança e reduzindo os custos de manutenção. Entre os vários princípios de detecção de danos, o método da impedância eletromecânica (E/M) baseia-se na medição da impedância elétrica do transdutor piezelétrico fixado à estrutura monitorada. Aqui, a exatidão e precisão do sistema de medição são fundamentais para o diagnóstico correto da estrutura. Portanto, essa dissertação apresenta uma análise comparativa de duas técnicas de medição de impedância para detecção de danos que são tipicamente utilizadas em analisadores de impedância comerciais e em outros sistemas de medição alternativos: medições em estado transitório utilizando um sinal de excitação de varredura e medições em estado estacionário utilizando um sinal senoidal puro para cada frequência de excitação. Os testes foram realizados com cargas resistivas e capacitivas de valores nominais 100 Ω e 10 nF, respectivamente, e com um transdutor piezelétrico fixado em uma barra de alumínio que representa uma estrutura monitorada. As duas técnicas foram comparadas com base na exatidão, precisão, sensibilidade à danos e tempo necessário para as medições. Os resultados destacam as características importantes de cada técnica, as quais devem ser consideradas para o desenvolvimento de sistemas de SHM basea... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Structural health monitoring (SHM) systems are scientifically and economically relevant as methods of detecting structural damage to various types of structures, thus increasing safety and reducing maintenance costs. Among the various principles of damage detection, the electromechanical impedance (EMI) method is based on the electrical impedance measurement of piezoelectric transducers attached to the monitored structure. Here, the accuracy and precision of the measurement system are fundamental for the correct diagnosis of the structure. Therefore, this dissertation presents a comparative analysis of two impedance measurement techniques for damage detection that are typically used in commercial impedance analyzers and other alternative measurement systems: transient-state measurements using a sweep excitation signal and steady-state measurements using a pure sinusoidal signal for each excitation frequency. Tests were performed with resistive and capacitive loads with nominal values of 100 Ω e 10 nF, respectively, and a piezoelectric transducer fixed to an aluminum bar representing a monitored structure. The two techniques were compared based on the accuracy, precision, sensibility to damage and time required for the measurements. The results highlight the important features of each technique, which should be considered for the development of impedance-based SHM systems and the correct diagnosis of monitored structures. / Mestre
2

Desempenho dos métodos de instalação de transdutores piezelétricos em sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânica / Performance of installation methods in piezoelectrics transducers in structural integrity monitoring systems based on electromechanical impedance

Silveira, Ricardo Zanni Mendes da [UNESP] 26 May 2017 (has links)
Submitted by RICARDO ZANNI MENDES DA SILVEIRA null (ricazanni@gmail.com) on 2017-06-07T16:11:41Z No. of bitstreams: 1 Dissertação_Mestrado_Eng_Eletrica_Ricardo_Zanni_2017.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-07T16:26:32Z (GMT) No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Made available in DSpace on 2017-06-07T16:26:32Z (GMT). No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) Previous issue date: 2017-05-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Transdutores piezelétricos são amplamente utilizados em muitos métodos não destrutivos para a detecção de danos estruturais em aplicações de monitoramento de integridade estrutural ou SHM (Structural Health Monitoring). Dentre os vários métodos não destrutivos, a técnica da impedância eletromecânica (E/M) é conhecida por utilizar cerâmicas piezelétricas pequenas e finas que desempenham simultaneamente as funções de atuador e sensor. O método convencional de instalação dessas cerâmicas piezelétricas na estrutura é utilizando um adesivo de alta rigidez como cola a base de epóxi ou cianoacrilato. No entanto, alguns estudos propõem métodos alternativos de instalação do transdutor, visando a sua reutilização ou que permitam o monitoramento em condições adversas sob as quais a instalação direta do sensor não seria possível. Assim, esta dissertação de mestrado apresenta uma análise experimental comparativa entre os principais métodos de acoplamento entre o transdutor piezelétrico e a estrutura monitorada em sistemas de SHM baseados na técnica da impedância eletromecânica (E/M). Os acoplamentos dos transdutores piezelétricos foram realizados pelos métodos da instalação direta, também conhecida como instalação convencional, por acoplamento magnético e lâminas de alumínio. O transdutor utilizado para os métodos de acoplamento foi o diafragma piezelétrico, comumente conhecido como buzzer. Testes com os três métodos de instalação foram realizados em estruturas de alumínio e o dano estrutural foi induzido por meio de adição de massa metálica (porca de aço), fixada diretamente na estrutura com cola a base de cianoacrilato. A análise comparativa entre os métodos de instalação foi realizada utilizando índices de danos obtidos das assinaturas de impedância elétrica dos diafragmas piezelétricos, além da função de resposta em frequência (FRF) e da densidade espectral de potência obtida pelo método da quebra do grafite. Os resultados experimentais apontam características importantes para os métodos de instalação, os quais têm influência significativa sobre a resposta em frequência e sensibilidade para a detecção de danos estruturais. / Piezoelectric transducers are widely used in many non-destructive methods for detecting structural damage in Structural Health Monitoring (SHM) applications. Among the various techniques for detecting structural damage, the electromechanical impedance (EMI) technique is known to use fine and small piezoelectric ceramics that simultaneously perform the actuator and sensor functions. The conventional method of installing these piezoelectric ceramics in the structure is by using a high stiffness adhesive such as epoxy or cyanoacrylate based glue. However, some studies propose alternative methods of installing the transducer for reuse or to allow monitoring under adverse conditions under which direct sensor installation would not be possible. Thus, this master's thesis presents a comparative experimental analysis between the main coupling methods between the piezoelectric transducer and the monitored structure in SHM systems based on the electromechanical impedance technique. The piezoelectric transducer couplings were made by direct installation methods, also known as conventional installation, by magnetic coupling and aluminum foils. The transducer used for the coupling methods was the piezoelectric diaphragm, commonly known as buzzer. Tests with these methods were carried out on aluminum structures and the structural damage was induced using metallic masses (steel nuts), fixed directly to the structure with cyanoacrylate-based glue. The comparison of the results analysis between the coupling methods was performed using the indices of damages obtained from electrical impedance signatures of the piezoelectric diaphragm, the frequency response function (FRF) and the power spectral density (PSD) obtained by pencil lead break (PLB) test. The experimental results indicate important characteristics for each installation method and that the mounting method has a significant influence on the frequency response and sensitivity for the detection of structural damage. / FAPESP: 2015/02500-6
3

Detecção de dano estrutural baseada na técnica da impedância eletromecânica em ambientes ruidosos / Detection of structural damage based on the electromechanical impedance technique in noisy environments

Campeiro, Leandro Melo 18 May 2018 (has links)
Submitted by Leandro Melo Campeiro (leandro_campeiro@yahoo.com.br) on 2018-05-24T19:40:02Z No. of bitstreams: 1 Dissertação de Leandro Melo Campeiro.pdf: 3027230 bytes, checksum: 32f869e7ce55b33b1e9c46a166e8cf5f (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-05-25T18:21:44Z (GMT) No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) / Made available in DSpace on 2018-05-25T18:21:44Z (GMT). No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) Previous issue date: 2018-05-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A técnica da impedância eletromecânica (E/M) tem sido amplamente estudada nas últimas décadas como um método não destrutivo para detectar danos estruturais em aplicações de monitoramento de integridade estrutural (SHM – structural health monitoring) usando transdutores piezelétricos de baixo custo. Esses transdutores operam simultaneamente como sensor e atuador e são fixados à estrutura monitorada utilizando um adesivo a base de cianoacrilato. Embora muitos estudos tenham relatado a eficácia desse método de detecção, inúmeros problemas práticos têm sido reportados, como os efeitos de ruído e vibração, que precisam ser considerados para permitir o uso eficaz desse método em aplicações reais. Portanto, esta dissertação de mestrado apresenta uma análise experimental dos efeitos do ruído e das vibrações na detecção de danos estruturais em sistemas de SHM baseados na técnica da impedância eletromecânica. Os experimentos foram realizados em uma barra de alumínio usando dois diafragmas piezelétricos, sendo que um deles foi usado para obter as assinaturas de impedância elétrica e o outro foi usado como atuador para introduzir ruído e vibração controlada. Para a simulação de dano foi utilizada uma pequena massa metálica fixada na estrutura com uso de adesivo a base de cianoacrilato. Os efeitos do ruído e da vibração sobre as assinaturas de impedância foram avaliados por meio do cálculo da função de coerência e de índices básicos de dano. Os resultados indicam que a vibração e o ruído afetam significativamente o limiar do menor dano detectável, o qual pode ser compensado pelo aumento do sinal de excitação do transdutor piezelétrico utilizado para a obtenção das assinaturas de impedância elétrica. / The electromechanical impedance (EMI) technique has been extensively studied in recent decades as a non-destructive method for detecting structural damage in structural health monitoring (SHM) applications using low-cost piezoelectric transducers. These transducers operate simultaneously as actuator and sensor and they are fixed to the structure using cyanoacrylate-based glue. Although many studies have reported the effectiveness of this detection method, a lot of practical problems shown up, such as the noise effects and vibration, that need to be addressed to enable this method’s effective use in real applications. Therefore, this master's thesis presents an experimental analysis of noise and vibration effects on the structural damage detection in impedance-based SHM systems. The experiments were performed on an aluminum bar using two piezoelectric diaphragms, where one was used to measure the electrical impedance signatures and the other was used as an actuator to introduce noise and controlled vibration. To simulate damage, a small metal mass was fixed to the structure using cyanoacrylate glue. The effects of noise and vibration on the impedance signatures were evaluated by computing the coherence function and basic damage indices. The results indicate that vibration and noise significantly affect the threshold of the lowest detectable damage, which can be compensated by increasing the excitation signal of the piezoelectric transducer that measure the electrical impedance signature.
4

Estudo comparativo de técnicas de medição e aquisição de sinais de transdutores piezelétricos para detecção de dano baseada na impedância eletromecânica / A Comparative Study of Measurement and Signal Acquisition Methods from Piezoelectric Transducers for Damage Detection Based on the Electromechanical Impedance

Budoya, Danilo Ecidir 20 April 2018 (has links)
Submitted by Danilo Ecidir Budoya (dbudoya.eng@gmail.com) on 2018-04-25T21:17:47Z No. of bitstreams: 1 Dissertação - Danilo Budoya.pdf: 3474646 bytes, checksum: 301f48ae4a6c065e915f91fe3d764dd8 (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-04-26T12:29:49Z (GMT) No. of bitstreams: 1 budoya_de_me_bauru.pdf: 3415870 bytes, checksum: 35422f7801e20a052d2c9a303aa7e2dd (MD5) / Made available in DSpace on 2018-04-26T12:29:49Z (GMT). No. of bitstreams: 1 budoya_de_me_bauru.pdf: 3415870 bytes, checksum: 35422f7801e20a052d2c9a303aa7e2dd (MD5) Previous issue date: 2018-04-20 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Sistemas de monitoramento de integridade estrutural (SHM – Structural Health Monitoring) são científica e economicamente relevantes como métodos de detecção de danos estruturais em diversos tipos de estruturas, aumentando assim a segurança e reduzindo os custos de manutenção. Entre os vários princípios de detecção de danos, o método da impedância eletromecânica (E/M) baseia-se na medição da impedância elétrica do transdutor piezelétrico fixado à estrutura monitorada. Aqui, a exatidão e precisão do sistema de medição são fundamentais para o diagnóstico correto da estrutura. Portanto, essa dissertação apresenta uma análise comparativa de duas técnicas de medição de impedância para detecção de danos que são tipicamente utilizadas em analisadores de impedância comerciais e em outros sistemas de medição alternativos: medições em estado transitório utilizando um sinal de excitação de varredura e medições em estado estacionário utilizando um sinal senoidal puro para cada frequência de excitação. Os testes foram realizados com cargas resistivas e capacitivas de valores nominais 100 Ω e 10 nF, respectivamente, e com um transdutor piezelétrico fixado em uma barra de alumínio que representa uma estrutura monitorada. As duas técnicas foram comparadas com base na exatidão, precisão, sensibilidade à danos e tempo necessário para as medições. Os resultados destacam as características importantes de cada técnica, as quais devem ser consideradas para o desenvolvimento de sistemas de SHM baseados na impedância e o diagnóstico correto das estruturas monitoradas. / Structural health monitoring (SHM) systems are scientifically and economically relevant as methods of detecting structural damage to various types of structures, thus increasing safety and reducing maintenance costs. Among the various principles of damage detection, the electromechanical impedance (EMI) method is based on the electrical impedance measurement of piezoelectric transducers attached to the monitored structure. Here, the accuracy and precision of the measurement system are fundamental for the correct diagnosis of the structure. Therefore, this dissertation presents a comparative analysis of two impedance measurement techniques for damage detection that are typically used in commercial impedance analyzers and other alternative measurement systems: transient-state measurements using a sweep excitation signal and steady-state measurements using a pure sinusoidal signal for each excitation frequency. Tests were performed with resistive and capacitive loads with nominal values of 100 Ω e 10 nF, respectively, and a piezoelectric transducer fixed to an aluminum bar representing a monitored structure. The two techniques were compared based on the accuracy, precision, sensibility to damage and time required for the measurements. The results highlight the important features of each technique, which should be considered for the development of impedance-based SHM systems and the correct diagnosis of monitored structures. / 2015/23272-1
5

Projeto de transdutores piezocompósitos de casca multi-camada utilizando o método de otimização topológica. / Design of piezocomposite multi-layered shell transducers using the topology optimization method.

Kiyono, César Yukishigue 15 January 2013 (has links)
Transdutores baseados em cascas piezocompósitas têm uma vasta aplicação no campo de estruturas inteligentes, principalmente como atuadores, sensores e coletores de energia. Essas estruturas piezocompósitas são geralmente compostas por dois ou mais tipos de materiais, como por exemplo materiais piezelétricos, ortotrópicos elásticos (possuem fibras de reforçamento) e isotrópicos (materiais homogêneos). Vários fatores devem ser considerados no projeto de transdutores baseados em cascas piezocompósitas, como o tamanho, a forma, a localização e a polarização do material piezelétrico, bem como a orientação das fibras do material ortotrópico. O projeto desses transdutores é complexo e trabalhos anteriores envolvendo esses tipos de materiais sugerem utilizar Método de Otimização Topológica (MOT) para aprimorar o desempenho dos transdutores distribuindo o material piezelétrico sobre substratos fixos de materiais isotrópicos e ortotrópicos, ou otimizar a orientação das fibras dos materiais ortotrópicos com material piezelétrico com tamanho, forma e localização previamente estabelecidos. Assim, nesta tese, propõe-se o desenvolvimento de uma metodologia baseada no MOT para projetar transdutores piezocompósitos de casca considerando, simultaneamente, a otimização da distribuição e do sentido de polarização do material piezelétrico, e também a otimização da orientação das fibras de materiais ortotrópicos, que é livre para assumir valores diferentes ao longo da mesma camada compósita. Utilizando essa metodologia, são obtidos resultados numéricos para atuadores e sensores em regime estático e para coletores de energia com circuito elétrico acoplado, em regime dinâmico amortecido. Para os casos dos sensores e dos coletores de energia, também são consideradas as tensões mecânicas na estrutura, as quais devem obedecer os critérios de von Mises (para materiais isotrópicos) e de Tsai-Wu (para materiais ortotrópicos) para que não haja falhas na estrutura, que está sujeita a esforços mecânicos. / Transducers based on laminated piezocomposite shell structures have a wide application in the field of smart structures, especially as actuators, sensors and energy harvesting devices. These piezocomposite structures are generally composed by two or more kinds of materials, such as piezoelectric, isotropic, and elastic orthotropic (fiber reinforcement) materials. Several factors must be considered in the design of piezocomposite transducers, such as size, shape, location and polarization of the piezoelectric material and the fiber orientation of the orthotropic material. The design of these transducers is complex and previous studies involving these types of materials suggest using \"Topology Optimization Method\" (TOM) to enhance the performance of piezoelectric transducers by distributing piezoelectric material over fixed isotropic and orthotropic substrate or to optimize the fiber orientation of orthotropic materials with piezoelectric patches previously established. Thus, this thesis proposes the development of a methodology based on the TOM to design laminated piezocomposite shell transducers by considering simultaneously the optimization of distribution and the polarization direction of the piezoelectric material, and also the optimization of the fiber orientation orthotropic material, which is free to assume different values along the same composite layer. By using this methodology, numerical results are obtained for actuators and sensors under static response, and energy harvesting devices with an electrical circuit coupled, in dynamic damped analysis. In the case of sensors and energy harvesting devices, which are subjected to mechanical loads, the mechanical stresses in the structure are also considered, which must satisfy two stress criteria to prevent failure: von Mises for isotropic materials and Tsai-Wu for orthotropic materials.
6

Projeto de transdutores piezocompósitos de casca multi-camada utilizando o método de otimização topológica. / Design of piezocomposite multi-layered shell transducers using the topology optimization method.

César Yukishigue Kiyono 15 January 2013 (has links)
Transdutores baseados em cascas piezocompósitas têm uma vasta aplicação no campo de estruturas inteligentes, principalmente como atuadores, sensores e coletores de energia. Essas estruturas piezocompósitas são geralmente compostas por dois ou mais tipos de materiais, como por exemplo materiais piezelétricos, ortotrópicos elásticos (possuem fibras de reforçamento) e isotrópicos (materiais homogêneos). Vários fatores devem ser considerados no projeto de transdutores baseados em cascas piezocompósitas, como o tamanho, a forma, a localização e a polarização do material piezelétrico, bem como a orientação das fibras do material ortotrópico. O projeto desses transdutores é complexo e trabalhos anteriores envolvendo esses tipos de materiais sugerem utilizar Método de Otimização Topológica (MOT) para aprimorar o desempenho dos transdutores distribuindo o material piezelétrico sobre substratos fixos de materiais isotrópicos e ortotrópicos, ou otimizar a orientação das fibras dos materiais ortotrópicos com material piezelétrico com tamanho, forma e localização previamente estabelecidos. Assim, nesta tese, propõe-se o desenvolvimento de uma metodologia baseada no MOT para projetar transdutores piezocompósitos de casca considerando, simultaneamente, a otimização da distribuição e do sentido de polarização do material piezelétrico, e também a otimização da orientação das fibras de materiais ortotrópicos, que é livre para assumir valores diferentes ao longo da mesma camada compósita. Utilizando essa metodologia, são obtidos resultados numéricos para atuadores e sensores em regime estático e para coletores de energia com circuito elétrico acoplado, em regime dinâmico amortecido. Para os casos dos sensores e dos coletores de energia, também são consideradas as tensões mecânicas na estrutura, as quais devem obedecer os critérios de von Mises (para materiais isotrópicos) e de Tsai-Wu (para materiais ortotrópicos) para que não haja falhas na estrutura, que está sujeita a esforços mecânicos. / Transducers based on laminated piezocomposite shell structures have a wide application in the field of smart structures, especially as actuators, sensors and energy harvesting devices. These piezocomposite structures are generally composed by two or more kinds of materials, such as piezoelectric, isotropic, and elastic orthotropic (fiber reinforcement) materials. Several factors must be considered in the design of piezocomposite transducers, such as size, shape, location and polarization of the piezoelectric material and the fiber orientation of the orthotropic material. The design of these transducers is complex and previous studies involving these types of materials suggest using \"Topology Optimization Method\" (TOM) to enhance the performance of piezoelectric transducers by distributing piezoelectric material over fixed isotropic and orthotropic substrate or to optimize the fiber orientation of orthotropic materials with piezoelectric patches previously established. Thus, this thesis proposes the development of a methodology based on the TOM to design laminated piezocomposite shell transducers by considering simultaneously the optimization of distribution and the polarization direction of the piezoelectric material, and also the optimization of the fiber orientation orthotropic material, which is free to assume different values along the same composite layer. By using this methodology, numerical results are obtained for actuators and sensors under static response, and energy harvesting devices with an electrical circuit coupled, in dynamic damped analysis. In the case of sensors and energy harvesting devices, which are subjected to mechanical loads, the mechanical stresses in the structure are also considered, which must satisfy two stress criteria to prevent failure: von Mises for isotropic materials and Tsai-Wu for orthotropic materials.
7

Desenvolvimento de um transdutor ultrassônico de potência aplicado em perfuração de rochas e usinagem de metais. / Development of a power ultrasonic transducer applied in drilling machining of metals and rock perforation.

Tayra, Victor Thomas 25 June 2014 (has links)
A sobreposição de frequências ultrassônicas a uma ferramenta em operações de perfuração, utilizando transdutores piezelétricos, resulta em melhorias na usinagem de metais, garantindo melhor acabamento (ausência de rebarba), redução do tamanho do cavaco e menor desgaste ferramental. A utilização desse tipo de técnica na perfuração de rochas reduz a carga axial e aumenta a velocidade do processo, possibilitando maior profundidade de perfuração, podendo vir a ser muito útil em pesquisas aplicadas à perfuração de reservas petrolíferas e exploração mineral. Este trabalho teve como objetivo simular e aplicar um transdutor piezelétrico ultrassônico de potência para perfuração de rochas e metais. Para as simulações numéricas duas técnicas foram utilizadas: o método dos elementos finitos (MEF) e o método das matrizes em cadeia (MMC). O MEF permitiu análises harmônicas e modais de forma rápida e precisa enquanto o MMC resultou em expressão analítica, possibilitando melhor compreensão dos parâmetros físicos e geométricos envolvidos na performance do transdutor. Ambos os métodos nortearam o projeto do protótipo a ser usado em ensaios de perfuração. Para a construção do protótipo, foi projetado um mandril para a fixação da broca, que foi adaptado a um transdutor de potência de 20 kHz. Ensaios de perfuração de rochas e de discos de alumínio foram realizados com o protótipo. A aplicação do protótipo à perfuração de rochas carbonáticas demonstrou redução no tempo de furação, quando comparada ao método convencional (sem aplicação de ultrassom). Na furação de discos de alumínio, a redução de rebarbas, quebra do cavaco durante a operação e melhor acabamento da peça, são conclusões evidentes das melhorias proporcionadas pela sobreposição de frequências ultrassônicas à broca. / Superposition of high frequency vibration in the tool, driven by a piezoelectric actuator, in a drilling machining process of metals results in some improvements such as finishing quality (without burr), reduction of tool wear and chip dimensions. Similar techniques applied in rock perforation reduce the axial load in the tool, which enhances the process velocity, resulting in deeper perforation. This might be useful in oil and mineral exploration, opening the feasibility of researches in this field. The aim of this work is to simulate and implement an ultrasonic piezoelectric transducer to perforate rocks and metals. Concerning numerical simulation, two techniques were performed: finite element method (FEM) and chain matrix method (CMM). FEM simulations provide fast and effective modal and harmonic analysis. CMM provide mathematical expressions, analytically exposing geometrical and physical parameters involved in the transducer performance. Both methods were the guide and basement for the prototype project, able to perform perforation experiments. For the construction of the prototype, a drill chuck were designed and adapted for a 20 kHz power ultrasonic transducer. Aluminum drilling and rock perforation experiments were carried out with this prototype. A lower perforation time was achieved in carbonate rocks when the ultrasound-aided method was used as opposed to the conventional method. Results in aluminum disks presented burr reduction, better part finishing and breakage of chips during operation. Those results evidently appoint some improvements due to the power ultrasonic superposition in the drilling process.
8

Desenvolvimento de um transdutor ultrassônico de potência aplicado em perfuração de rochas e usinagem de metais. / Development of a power ultrasonic transducer applied in drilling machining of metals and rock perforation.

Victor Thomas Tayra 25 June 2014 (has links)
A sobreposição de frequências ultrassônicas a uma ferramenta em operações de perfuração, utilizando transdutores piezelétricos, resulta em melhorias na usinagem de metais, garantindo melhor acabamento (ausência de rebarba), redução do tamanho do cavaco e menor desgaste ferramental. A utilização desse tipo de técnica na perfuração de rochas reduz a carga axial e aumenta a velocidade do processo, possibilitando maior profundidade de perfuração, podendo vir a ser muito útil em pesquisas aplicadas à perfuração de reservas petrolíferas e exploração mineral. Este trabalho teve como objetivo simular e aplicar um transdutor piezelétrico ultrassônico de potência para perfuração de rochas e metais. Para as simulações numéricas duas técnicas foram utilizadas: o método dos elementos finitos (MEF) e o método das matrizes em cadeia (MMC). O MEF permitiu análises harmônicas e modais de forma rápida e precisa enquanto o MMC resultou em expressão analítica, possibilitando melhor compreensão dos parâmetros físicos e geométricos envolvidos na performance do transdutor. Ambos os métodos nortearam o projeto do protótipo a ser usado em ensaios de perfuração. Para a construção do protótipo, foi projetado um mandril para a fixação da broca, que foi adaptado a um transdutor de potência de 20 kHz. Ensaios de perfuração de rochas e de discos de alumínio foram realizados com o protótipo. A aplicação do protótipo à perfuração de rochas carbonáticas demonstrou redução no tempo de furação, quando comparada ao método convencional (sem aplicação de ultrassom). Na furação de discos de alumínio, a redução de rebarbas, quebra do cavaco durante a operação e melhor acabamento da peça, são conclusões evidentes das melhorias proporcionadas pela sobreposição de frequências ultrassônicas à broca. / Superposition of high frequency vibration in the tool, driven by a piezoelectric actuator, in a drilling machining process of metals results in some improvements such as finishing quality (without burr), reduction of tool wear and chip dimensions. Similar techniques applied in rock perforation reduce the axial load in the tool, which enhances the process velocity, resulting in deeper perforation. This might be useful in oil and mineral exploration, opening the feasibility of researches in this field. The aim of this work is to simulate and implement an ultrasonic piezoelectric transducer to perforate rocks and metals. Concerning numerical simulation, two techniques were performed: finite element method (FEM) and chain matrix method (CMM). FEM simulations provide fast and effective modal and harmonic analysis. CMM provide mathematical expressions, analytically exposing geometrical and physical parameters involved in the transducer performance. Both methods were the guide and basement for the prototype project, able to perform perforation experiments. For the construction of the prototype, a drill chuck were designed and adapted for a 20 kHz power ultrasonic transducer. Aluminum drilling and rock perforation experiments were carried out with this prototype. A lower perforation time was achieved in carbonate rocks when the ultrasound-aided method was used as opposed to the conventional method. Results in aluminum disks presented burr reduction, better part finishing and breakage of chips during operation. Those results evidently appoint some improvements due to the power ultrasonic superposition in the drilling process.

Page generated in 0.4806 seconds