• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 9
  • 8
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Reconstrução não-linear completa de imagens de tomografia por impedância elétrica utilizando o método D-bar 2D. / Reconstruction nonlinear full of images of electrical impedance tomography using the 2D D-bar method.

Montoya Vallejo, Miguel Fernando 16 October 2012 (has links)
Neste trabalho desenvolveu-se desenvolver uma versão sem linearizações do método D-bar para Tomografia por Impedância Elétrica (TIE). O problema inverso de TIE é não-linear e mal-posto. O algoritmo baseia-se na prova de existência e unicidade de Adrian Nachman [Ann. of Math. 143 (1996)] para domínios com distribuição de condutividade duas vezes diferenciáveis. O método faz uso de uma Transformada de Fourier não-linear chamada scattering transform, e o caráter mal-posto do Problema Inverso torna-se evidente no cálculo desta transformada, mais especificamente na determinação das soluções Complex Geometrical Optics (CGO). Atuais implementações práticas do método D-bar para padrões trigonométricos tem aproximado os valores na fronteira das soluções CGO por seu comportamento assintótico no cálculo da scattering transform, o que constitue uma linearização nesta etapa específica do método. Neste trabalho calcula-se a scattering transform a partir das soluções exponencialmente crescentes, o que implica calcular as funções Green de Faddeev, com o objetivo de encontrar imagens com maior resolução espacial e precisão nos valores de condutividade por ter resolvido o problema não-linear de forma completa. Dados de simulação numérica e experimentais usando padrões de injeção pula eletrodos e trigonométricos foram usados na avaliação do método. As imagens obtidas apresentam comportamento diferente em função do padrão de injeção utilizado. Do cálculo completo da transformada scattering resultam imagens com melhor resolução espacial. As imagens reconstruídas a partir de padrões de injeção trigonométricos apresentam também melhor resolução espacial comparadas as imagens reconstruídas a partir de padrões por pares, separados por três eletrodos. / This work proposes to develop a version of the D-bar method linearization for Electrical Impedance Tomography (EIT). The inverse problem of EIT is both nonlinear and very ill-posed. The version of the D-bar method implemented here is based on the existence and uniqueness proof of Adrian Nachman [Ann. of Math. 143 (1996)]. The method relies on the use of a nonlinear Fourier transform called the scattering transform, and the inherent ill-posedness of the inverse conductivity problem becomes evident in the computation of the scattering transform, more specifically in the determination of the Complex Geometrical Optics (CGO) solutions. Current practical implementations of the D-bar method using trigonometric patterns have replaced the boundary values of the CGO solutions by their asymptotic behavior in the calculation of the scattering transform, which is a linearization in this particular step of the overall method. This work proposes to calculate the scattering transform from exponentially growing solutions, which implies the calculation of the Faddeev Greens function, with the goal of obtaining images with higher resolution and accuracy in the conductivity values because the full nonlinear problem is solved. Numerical and experimental data using pairwise and trigonometric current injection patterns were used to evaluate the performance of the method. Better spatial resolution is obtained from the complete computation of the scattering transform. Reconstructed images from trigonometric current patterns also show better spatial resolution compared to pairwise current injection patterns, skipping three electrodes.
2

Um método D-bar para estimar admitividade em 2-D através de tomografia por impedância elétrica. / A D-bar method for recovering admittivity in 2-D electrical impedance tomography.

Lara Herrera, Claudia Natalia 23 August 2012 (has links)
Propõe-se um novo método D-bar de Tomografia por Impedância Elétrica (TIE) para obter, simultaneamente, a condutividade e a permitividade de um domínio 2-D. O algoritmo direto baseia-se na prova de existência e unicidade do artigo de E. Francini [1]. A caracterização de tecidos biológicos é fortemente facilitada a partir do conhecimento de suas propriedades elétricas. Particularmente, nas aplicações médicas de TIE há grande interesse na permitividade, uma vez que, vários autores tem apresentado critérios para distinguir patologias baseados nesta propriedade, um exemplo constitui a determinação de presença ou ausência de sangue em líquidos acumulados no pulmão. Realizam-se testes com dados simulados numericamente e experimentais com o propósito de verificar e entender as propriedades, capacidades e limitações do algoritmo implementado. No caso dos testes numéricos, é desenvolvido um programa que resolve o problema direto da admitividade, o qual permite calcular conjuntos de dados de voltagem numéricos. São simulados dados aplicando padrões de corrente trigonométricos e por pares. As soluções exponencialmente crescentes do problema inverso são parte essencial do algoritmo e devem ser decompostas nas bases dos padrões de injeção de corrente. A compreensão da natureza destas decomposições para padrões de injeção trigonométricos e por pares, levou ao estabelecimento de especificações no projeto de um sistema de TIE para este algoritmo. Os resultados encorajadores numéricos e experimentais obtidos nas reconstruções de condutividade e permitividade, quanto à resolução espacial e às magnitudes, indicam que o algoritmo é promissor para uso clínico. / This work proposes a new D-bar method of Electrical Impedance Tomography (EIT) for reconstructing the conductivity and permittivity simultaneously in a 2-D domain. The direct algorithm presented is based on the existence and uniqueness proof by E. Francini [1]. Biological tissue characterization is strongly facilitated by the knowledge of its electric properties. In EIT medical applications there is great interest in the permittivity as an additional property for distinguishing pathologies. For instance, the determination of presence or absence of blood in fluid accumulation in the lung. Numerical and experimental data tests are carried out in order to verify and understand the properties, capabilities and limitations of the implemented algorithm. A numerical phantom to solve the forward admittivity problem is developed which allows to simulate voltage data sets. Trigonometric and pairwise injection current patterns are applied. Exponentially growing solutions of the inverse problem are a key part of the algorithm, which have to be expanded in terms of the current patterns. Understanding the nature of these expansions for trigonometric and pairwise injection current patterns leads to a set of specifications in the design of an EIT system for this algorithm. The encouraging numerical and experimental results obtained in conductivity and permittivity reconstructions, regarding the magnitude and spatial resolution, indicate that the algorithm is promising for clinical use.
3

Um método D-bar para estimar admitividade em 2-D através de tomografia por impedância elétrica. / A D-bar method for recovering admittivity in 2-D electrical impedance tomography.

Claudia Natalia Lara Herrera 23 August 2012 (has links)
Propõe-se um novo método D-bar de Tomografia por Impedância Elétrica (TIE) para obter, simultaneamente, a condutividade e a permitividade de um domínio 2-D. O algoritmo direto baseia-se na prova de existência e unicidade do artigo de E. Francini [1]. A caracterização de tecidos biológicos é fortemente facilitada a partir do conhecimento de suas propriedades elétricas. Particularmente, nas aplicações médicas de TIE há grande interesse na permitividade, uma vez que, vários autores tem apresentado critérios para distinguir patologias baseados nesta propriedade, um exemplo constitui a determinação de presença ou ausência de sangue em líquidos acumulados no pulmão. Realizam-se testes com dados simulados numericamente e experimentais com o propósito de verificar e entender as propriedades, capacidades e limitações do algoritmo implementado. No caso dos testes numéricos, é desenvolvido um programa que resolve o problema direto da admitividade, o qual permite calcular conjuntos de dados de voltagem numéricos. São simulados dados aplicando padrões de corrente trigonométricos e por pares. As soluções exponencialmente crescentes do problema inverso são parte essencial do algoritmo e devem ser decompostas nas bases dos padrões de injeção de corrente. A compreensão da natureza destas decomposições para padrões de injeção trigonométricos e por pares, levou ao estabelecimento de especificações no projeto de um sistema de TIE para este algoritmo. Os resultados encorajadores numéricos e experimentais obtidos nas reconstruções de condutividade e permitividade, quanto à resolução espacial e às magnitudes, indicam que o algoritmo é promissor para uso clínico. / This work proposes a new D-bar method of Electrical Impedance Tomography (EIT) for reconstructing the conductivity and permittivity simultaneously in a 2-D domain. The direct algorithm presented is based on the existence and uniqueness proof by E. Francini [1]. Biological tissue characterization is strongly facilitated by the knowledge of its electric properties. In EIT medical applications there is great interest in the permittivity as an additional property for distinguishing pathologies. For instance, the determination of presence or absence of blood in fluid accumulation in the lung. Numerical and experimental data tests are carried out in order to verify and understand the properties, capabilities and limitations of the implemented algorithm. A numerical phantom to solve the forward admittivity problem is developed which allows to simulate voltage data sets. Trigonometric and pairwise injection current patterns are applied. Exponentially growing solutions of the inverse problem are a key part of the algorithm, which have to be expanded in terms of the current patterns. Understanding the nature of these expansions for trigonometric and pairwise injection current patterns leads to a set of specifications in the design of an EIT system for this algorithm. The encouraging numerical and experimental results obtained in conductivity and permittivity reconstructions, regarding the magnitude and spatial resolution, indicate that the algorithm is promising for clinical use.
4

Reconstrução não-linear completa de imagens de tomografia por impedância elétrica utilizando o método D-bar 2D. / Reconstruction nonlinear full of images of electrical impedance tomography using the 2D D-bar method.

Miguel Fernando Montoya Vallejo 16 October 2012 (has links)
Neste trabalho desenvolveu-se desenvolver uma versão sem linearizações do método D-bar para Tomografia por Impedância Elétrica (TIE). O problema inverso de TIE é não-linear e mal-posto. O algoritmo baseia-se na prova de existência e unicidade de Adrian Nachman [Ann. of Math. 143 (1996)] para domínios com distribuição de condutividade duas vezes diferenciáveis. O método faz uso de uma Transformada de Fourier não-linear chamada scattering transform, e o caráter mal-posto do Problema Inverso torna-se evidente no cálculo desta transformada, mais especificamente na determinação das soluções Complex Geometrical Optics (CGO). Atuais implementações práticas do método D-bar para padrões trigonométricos tem aproximado os valores na fronteira das soluções CGO por seu comportamento assintótico no cálculo da scattering transform, o que constitue uma linearização nesta etapa específica do método. Neste trabalho calcula-se a scattering transform a partir das soluções exponencialmente crescentes, o que implica calcular as funções Green de Faddeev, com o objetivo de encontrar imagens com maior resolução espacial e precisão nos valores de condutividade por ter resolvido o problema não-linear de forma completa. Dados de simulação numérica e experimentais usando padrões de injeção pula eletrodos e trigonométricos foram usados na avaliação do método. As imagens obtidas apresentam comportamento diferente em função do padrão de injeção utilizado. Do cálculo completo da transformada scattering resultam imagens com melhor resolução espacial. As imagens reconstruídas a partir de padrões de injeção trigonométricos apresentam também melhor resolução espacial comparadas as imagens reconstruídas a partir de padrões por pares, separados por três eletrodos. / This work proposes to develop a version of the D-bar method linearization for Electrical Impedance Tomography (EIT). The inverse problem of EIT is both nonlinear and very ill-posed. The version of the D-bar method implemented here is based on the existence and uniqueness proof of Adrian Nachman [Ann. of Math. 143 (1996)]. The method relies on the use of a nonlinear Fourier transform called the scattering transform, and the inherent ill-posedness of the inverse conductivity problem becomes evident in the computation of the scattering transform, more specifically in the determination of the Complex Geometrical Optics (CGO) solutions. Current practical implementations of the D-bar method using trigonometric patterns have replaced the boundary values of the CGO solutions by their asymptotic behavior in the calculation of the scattering transform, which is a linearization in this particular step of the overall method. This work proposes to calculate the scattering transform from exponentially growing solutions, which implies the calculation of the Faddeev Greens function, with the goal of obtaining images with higher resolution and accuracy in the conductivity values because the full nonlinear problem is solved. Numerical and experimental data using pairwise and trigonometric current injection patterns were used to evaluate the performance of the method. Better spatial resolution is obtained from the complete computation of the scattering transform. Reconstructed images from trigonometric current patterns also show better spatial resolution compared to pairwise current injection patterns, skipping three electrodes.
5

Design and fabrication of GaPO4 ultrasonic transducer for NDT at high temperatures

Kostan, Mario January 2018 (has links)
There is a critical need for inspection and condition monitoring of high temperature critical components such as pipelines and welds in electrical power generation and other plants operating at temperatures as high as 580°C. The high temperatures and pressures experienced in these pipelines, particularly for ageing plants lead to creep, fatigue and corrosion type defects. Safety of these plants is of paramount importance, and regular maintenance is carried out during planned outages at ambient temperatures. Ultrasonic non-destructive testing can be used to detect defects in the weld at ambient temperatures. However, at high operational temperatures, this technique cannot be applied due to the lack of high temperature transducers. This research has achieved significant advances towards enabling ultrasonic inspection and condition monitoring of high temperature critical points, by developing an ultrasonic transducer around an advanced piezoelectric single crystal material, called Gallium Orthophosphate (GaPO4), which can operate at the required temperature of 580°C. Based on its reported piezoelectric and other properties, and its commercial availability, GaPO4 was chosen as a candidate active material for application in a prototype high temperature transducer. In a series of confidence building tests with the selected piezoelectric material (electrical characterisation via the impedance method), it has been demonstrated that the GaPO4 piezoelectric elements are stable when subjected to 580°C for more than 600 hours. Ultrasonic thickness gauging has shown that GaPO4 works as a functional transducer generating and receiving ultrasound waves at 580°C for at least 360 hours. Furthermore, the sensitivity of the GaPO4 transducer to detect defects with simple geometry was successfully tested through measurements on steel blocks containing artificial defects (side-drilled holes) up to the same high temperatures. Based on the characterisation results from the impedance and ultrasonic measurements, a prototype ultrasonic transducer for operation at high temperatures has been designed and manufactured. The new ultrasonic transducer was tested in a laboratory environment using a steel calibration block, high temperature couplant, SONO 1100, and an electric furnace. In the range from ambient temperatures up to the target of 580°C, the ultrasonic transducer kept a signal-to-noise (SNR) level sufficiently high, above the threshold of 6 dB, which is high enough for practical non-destructive testing and condition monitoring.
6

Impedance-Based Structural Health Monitoring of Wind Turbine Blades

Pitchford, Corey 21 November 2007 (has links)
Wind power is a fast-growing source of non-polluting, renewable energy with vast potential. However, current wind technology must be improved before the potential of wind power can be fully realized. One of the key components in improving wind turbines is their blades. Blade failure is very costly because blade failure can damage other blades, the wind turbine itself, and possibly other wind turbines. A successful structural health monitoring (SHM) system incorporated into wind turbines could extend blade life and allow for less conservative designs. Impedance-based SHM is a method which has shown promise on a wide variety of structures. The technique utilizes small piezoceramic (PZT) patches attached to a structure as self-sensing actuators to both excite the structure with high-frequency excitations, and monitor any changes in structural mechanical impedance. By monitoring the electrical impedance of the PZT, assessments can be made about the integrity of the mechanical structure. Recent advances in hardware systems with onboard computing, including actuation and sensing, computational algorithms, and wireless telemetry, have improved the accessibility of the impedance method for in-field measurements. The feasibility of implementing impedance-based SHM on wind turbine blades is investigated in this work. Experimentation was performed to determine the capability of the method to detect damage on blades. First, tests were run to detect both indirect and actual forms of damage on a section of an actual wind turbine blade provided by Sandia National Laboratories. Additional tests were run on the same blade section using a high-frequency response function method of SHM for comparison. Finally, based on the results of the initial testing, the impedance method was utilized in an attempt to detect damage during a fatigue test of an experimental wind turbine blade at the National Renewable Energy Laboratory's National Wind Technology Center. / Master of Science
7

Caracterização da anisotropia na permissividade de osso cortical utilizando o método da impedância. / Characterizantion of anisotropy in the permittivity of cortical bone using the impedance method.

Yasmara Conceição De Polli 04 April 2008 (has links)
O conhecimento das propriedades dielétricas do osso tem se mostrado importante na medicina ortopédica para aplicações em diagnóstico e tratamento da osteoporose, de fraturas, controle da osteonecrose e, também, na área de cerâmicas industriais (porcelana de osso). Neste trabalho, apresenta-se uma metodologia de avaliação das permissividades complexas de osso cortical de fêmur bovino desidratado, utilizando-se o método de impedância em uma linha de transmissão. Esta se constitui de um condutor coaxial, do tipo N, de uma porta, e um terminal aberto, que é conectado a um analisador de impedância. A faixa de freqüência considerada está compreendida entre 100 Hz e 1 MHz. Em particular, apresenta-se uma metodologia de caracterização dielétrica de osso, com ênfase nas avaliações das suas características anisotrópicas. Alguns resultados das propriedades dielétricas são comparados com os valores experimentais e teóricos disponíveis na literatura. Este procedimento é justificado, haja vista que os valores experimentais encontrados na literatura são esparsos e pontuais, quando se considera toda a faixa do espectro eletromagnético avaliado. Ressalta-se que não existe um consenso entre especialistas da área sobre a precisão e metodologia de obtenção destes. O mesmo ocorre com relação aos protocolos de medição propostos nas normas internacionais, em particular, quando se buscam padrões de avaliações de materiais biológicos sólidos. Os valores da permissividade obtidos com as medidas realizadas entre 100 Hz e 1 MHz evidenciam a presença de uma anisotropia efetiva, sendo esta característica ressaltada em freqüências da ordem de algumas dezenas de kHz. Embora o fenômeno de anisotropia não se manifeste nas faixas superiores à anteriormente mencionada, algumas medidas foram realizadas, também, numa faixa de freqüências superiores, entre 50 MHz e 3 GHz. Utilizou-se um analisador de redes conectado a um dispositivo coaxial de duas portas, visando avaliar a adequabilidade dos procedimentos de preparação do tecido ósseo na avaliação das características de materiais biológicos em altas freqüências, já que se dispunha da instrumentação necessária e de alguns resultados, obtidos na literatura, para sua validação. / The knowledge of the dielectric properties of bones has become important to orthopedic therapy, for applications in the diagnosis and treatment of osteoporosis, fractures, and osteonecrosis, as well as is the industrial ceramics field (bone china). This work proposes a methodology for the evaluation of the complex permittivity of a dehydrated cortical bone of bovine femur, using an impedance method in a transmission line. The transmission line is composed by an one-port open-ended N-type coaxial conductor, connected to an impedance analyzer. The frequency range studied was 100 Hz - 1 MHz. The methodology proposed is proper for the dielectric characterization of bone and this work emphasizes the evaluation of its anisotropic characteristics. Some dielectric properties experimentally found in this work are compared to the experimental and theoretical results available in literature, which are sparse and punctual in the considered electromagnetic spectrum. It is pointed out that there is no agreement among the experts when the subject is the proper measuring methodology and its precision. The same occurs when the subject is the measuring protocols proposed by the international standards, especially for solid biological materials. The permittivity results obtained in frequencies between 100 Hz and 1 MHz evince an effective anisotropy, which stands out in frequencies of a few tens of kHz. Although the anisotropy phenomenon does not occur in a frequency range higher than the one previously mentioned, some measures were taken in the 50 MHz - 3 GHz range for validation, based on results from literature. A network analyzer and a two-port coaxial device were then used in such measures, which aimed the evaluation of the adequacy of the procedure used in the preparation of the bone tissue in high-frequency measurements.
8

Caracterização da anisotropia na permissividade de osso cortical utilizando o método da impedância. / Characterizantion of anisotropy in the permittivity of cortical bone using the impedance method.

De Polli, Yasmara Conceição 04 April 2008 (has links)
O conhecimento das propriedades dielétricas do osso tem se mostrado importante na medicina ortopédica para aplicações em diagnóstico e tratamento da osteoporose, de fraturas, controle da osteonecrose e, também, na área de cerâmicas industriais (porcelana de osso). Neste trabalho, apresenta-se uma metodologia de avaliação das permissividades complexas de osso cortical de fêmur bovino desidratado, utilizando-se o método de impedância em uma linha de transmissão. Esta se constitui de um condutor coaxial, do tipo N, de uma porta, e um terminal aberto, que é conectado a um analisador de impedância. A faixa de freqüência considerada está compreendida entre 100 Hz e 1 MHz. Em particular, apresenta-se uma metodologia de caracterização dielétrica de osso, com ênfase nas avaliações das suas características anisotrópicas. Alguns resultados das propriedades dielétricas são comparados com os valores experimentais e teóricos disponíveis na literatura. Este procedimento é justificado, haja vista que os valores experimentais encontrados na literatura são esparsos e pontuais, quando se considera toda a faixa do espectro eletromagnético avaliado. Ressalta-se que não existe um consenso entre especialistas da área sobre a precisão e metodologia de obtenção destes. O mesmo ocorre com relação aos protocolos de medição propostos nas normas internacionais, em particular, quando se buscam padrões de avaliações de materiais biológicos sólidos. Os valores da permissividade obtidos com as medidas realizadas entre 100 Hz e 1 MHz evidenciam a presença de uma anisotropia efetiva, sendo esta característica ressaltada em freqüências da ordem de algumas dezenas de kHz. Embora o fenômeno de anisotropia não se manifeste nas faixas superiores à anteriormente mencionada, algumas medidas foram realizadas, também, numa faixa de freqüências superiores, entre 50 MHz e 3 GHz. Utilizou-se um analisador de redes conectado a um dispositivo coaxial de duas portas, visando avaliar a adequabilidade dos procedimentos de preparação do tecido ósseo na avaliação das características de materiais biológicos em altas freqüências, já que se dispunha da instrumentação necessária e de alguns resultados, obtidos na literatura, para sua validação. / The knowledge of the dielectric properties of bones has become important to orthopedic therapy, for applications in the diagnosis and treatment of osteoporosis, fractures, and osteonecrosis, as well as is the industrial ceramics field (bone china). This work proposes a methodology for the evaluation of the complex permittivity of a dehydrated cortical bone of bovine femur, using an impedance method in a transmission line. The transmission line is composed by an one-port open-ended N-type coaxial conductor, connected to an impedance analyzer. The frequency range studied was 100 Hz - 1 MHz. The methodology proposed is proper for the dielectric characterization of bone and this work emphasizes the evaluation of its anisotropic characteristics. Some dielectric properties experimentally found in this work are compared to the experimental and theoretical results available in literature, which are sparse and punctual in the considered electromagnetic spectrum. It is pointed out that there is no agreement among the experts when the subject is the proper measuring methodology and its precision. The same occurs when the subject is the measuring protocols proposed by the international standards, especially for solid biological materials. The permittivity results obtained in frequencies between 100 Hz and 1 MHz evince an effective anisotropy, which stands out in frequencies of a few tens of kHz. Although the anisotropy phenomenon does not occur in a frequency range higher than the one previously mentioned, some measures were taken in the 50 MHz - 3 GHz range for validation, based on results from literature. A network analyzer and a two-port coaxial device were then used in such measures, which aimed the evaluation of the adequacy of the procedure used in the preparation of the bone tissue in high-frequency measurements.
9

Cross-sectional study of the association between day-to-day home blood pressure variability and visceral fat area measured using the dual impedance method / 自宅血圧日間変動とデュアルインピーダンス法を用いて計測した内臓脂肪面積の関連についての検討

Kuwabara, Junko 25 March 2019 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(医学) / 乙第13233号 / 論医博第2173号 / 新制||医||1036(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 川村 孝, 教授 横出 正之, 教授 福原 俊一 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
10

DEVELOPMENT AND INTEGRATION OF HARDWARE AND SOFTWARE FOR ACTIVE-SENSORS IN STRUCTURAL HEALTH MONITORING

OVERLY, TIMOTHY G. S. 03 July 2007 (has links)
No description available.

Page generated in 0.0432 seconds