• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • Tagged with
  • 45
  • 45
  • 13
  • 12
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Restabelecimento da atividade ovariana em vacas nelore (Bos taurus indicus) tratadas com implante subcutâneo de agonista de GnRH (deslorelina) durante 70 dias

Destro, Flavia Caroline [UNESP] 25 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:16Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-25Bitstream added on 2014-06-13T18:58:54Z : No. of bitstreams: 1 destro_fc_me_botfmvz.pdf: 752446 bytes, checksum: f518354aa765561a5fac57e44fd72386 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Avaliar em vacas Nelore (Bos indicus) tratadas por longo prazo (70 dias) com implantes subcutâneos de agonista de GnRH (deslorelina- -Suprelorin® 4,7 mg) a dinâmica folicular ovariana e as concentrações plasmáticas do hormônio folículo estimulante (FSH), do hormônio luteinizante (LH) e da progesterona (P4) durante os últimos 20 dias do tratamento, e a dinâmica folicular ovariana e as concentrações de P4 da remoção do implante até a ovulação. Quinze vacas Nelore com escore de condição corporal (ECC) 3 tiveram sua ovulação sincronizada. No dia da detecção da ovulação, 10 animais foram selecionados para serem submetidos ao tratamento com implante subcutâneo de deslorelina. Nos últimos 20 dias do período de tratamento, foram realizados exames ultrassonográficos, a cada 2-3 dias, para caracterização da dinâmica folicular e registro dos folículos, que foram classificados de acordo com o diâmetro como: I (< 0,4 cm), II (0,4-0,6cm) e III (> 0,6cm). Neste mesmo período foram coletadas amostras de sangue para mensuração das concentrações plasmáticas de FSH, LH e P4. Os resultados foram submetidos à análise de variância e as diferenças entre as médias foram determinadas através do teste de Tukey. Durante os 70 dias de tratamento com a deslorelina nenhum animal ovulou, apesar de não ter sido observado a supressão do desenvolvimento folicular. Esse achado ultrassonográfico foi confirmado pelos resultados da concentração plasmática de P4, que se manteve em média abaixo de 0,16 ng/mL. Durante os últimos 20 dias de tratamento, quatro animais apresentaram desenvolvimento folicular com diâmetro máximo variando entre 0,4 a 0,6 cm, enquanto que nos três restantes foram observados diâmetros superiores a 0,9 a 1,2 cm. As secreções de FSH e LH não foram abolidas ao longo do estudo. Após a remoção... / The objective of the present study was to evaluate in Nelore cows (Bos indicus) treated for a long period (70 days) with subcutaneous implants of deslorelin (GnRH agonist-Suprelorin® 4,7mg) the ovarian follicular dynamics and plasma concentrations of follicle-stimulating hormone (FSH), luteinizing hormone (LH) and progesterone (P4) during the last 20 days of treatment and the ovarian follicular dynamics and plasma concentrations of P4 from the removal of the implant until the ovulation. Fifteen Nelore cows with body condition score (BCS) 3 had their ovulation synchronized. At the day of the detection of ovulation 10 animals were randomly selected to receive subcutaneous implant of deslorelin. In the last 20 days of the period of implantation, ultrasonographic scans were realized, every 2-3 days, in order to characterize the follicular dynamics and to register the follicles which were classified according to diameter as: I (< 0,4 cm), II (0,4-0,6cm) and III (> 0,6cm). Simultaneously, blood samples were collected to measure plasma concentrations of FSH, LH and P4. Results were tested by analysis of variance and difference between means were defined using Tukey’s test. During the 70 days of deslorelin implantation none of the animals ovulated, despite of the implant not suppressing all follicular development. This ultrasonographic finding was confirmed by the results of P4 plasma concentrations, which was kept in average below 0,16 ng/mL. During the last 20 days of implantation, four animals presented follicular development with maximum diameter ranging through 0,4 to 0,6 cm while in the three remaining animals the observed diameter ranged through 0,9 to 1,2 cm. The secretion of LH and FSH was not entirely suppressed during the study. After the removal of the deslorelin subcutaneous implant (Suprelorin® 4,7 mg), the period of... (Complete abstract click electronic access below)
42

Restabelecimento da atividade ovariana em vacas nelore (Bos taurus indicus) tratadas com implante subcutâneo de agonista de GnRH (deslorelina) durante 70 dias /

Destro, Flavia Caroline. January 2012 (has links)
Orientador: João Carlos Pinheiro Ferreira / Banca: Eunice Oba / Banca: Lindsay Unno Gimenes / Banca: Sony Dimas Bicudo / Banca: Thales Ricardo Rigo Barreiros / Resumo: Avaliar em vacas Nelore (Bos indicus) tratadas por longo prazo (70 dias) com implantes subcutâneos de agonista de GnRH (deslorelina- -Suprelorin® 4,7 mg) a dinâmica folicular ovariana e as concentrações plasmáticas do hormônio folículo estimulante (FSH), do hormônio luteinizante (LH) e da progesterona (P4) durante os últimos 20 dias do tratamento, e a dinâmica folicular ovariana e as concentrações de P4 da remoção do implante até a ovulação. Quinze vacas Nelore com escore de condição corporal (ECC) 3 tiveram sua ovulação sincronizada. No dia da detecção da ovulação, 10 animais foram selecionados para serem submetidos ao tratamento com implante subcutâneo de deslorelina. Nos últimos 20 dias do período de tratamento, foram realizados exames ultrassonográficos, a cada 2-3 dias, para caracterização da dinâmica folicular e registro dos folículos, que foram classificados de acordo com o diâmetro como: I (< 0,4 cm), II (0,4-0,6cm) e III (> 0,6cm). Neste mesmo período foram coletadas amostras de sangue para mensuração das concentrações plasmáticas de FSH, LH e P4. Os resultados foram submetidos à análise de variância e as diferenças entre as médias foram determinadas através do teste de Tukey. Durante os 70 dias de tratamento com a deslorelina nenhum animal ovulou, apesar de não ter sido observado a supressão do desenvolvimento folicular. Esse achado ultrassonográfico foi confirmado pelos resultados da concentração plasmática de P4, que se manteve em média abaixo de 0,16 ng/mL. Durante os últimos 20 dias de tratamento, quatro animais apresentaram desenvolvimento folicular com diâmetro máximo variando entre 0,4 a 0,6 cm, enquanto que nos três restantes foram observados diâmetros superiores a 0,9 a 1,2 cm. As secreções de FSH e LH não foram abolidas ao longo do estudo. Após a remoção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of the present study was to evaluate in Nelore cows (Bos indicus) treated for a long period (70 days) with subcutaneous implants of deslorelin (GnRH agonist-Suprelorin® 4,7mg) the ovarian follicular dynamics and plasma concentrations of follicle-stimulating hormone (FSH), luteinizing hormone (LH) and progesterone (P4) during the last 20 days of treatment and the ovarian follicular dynamics and plasma concentrations of P4 from the removal of the implant until the ovulation. Fifteen Nelore cows with body condition score (BCS) 3 had their ovulation synchronized. At the day of the detection of ovulation 10 animals were randomly selected to receive subcutaneous implant of deslorelin. In the last 20 days of the period of implantation, ultrasonographic scans were realized, every 2-3 days, in order to characterize the follicular dynamics and to register the follicles which were classified according to diameter as: I (< 0,4 cm), II (0,4-0,6cm) and III (> 0,6cm). Simultaneously, blood samples were collected to measure plasma concentrations of FSH, LH and P4. Results were tested by analysis of variance and difference between means were defined using Tukey's test. During the 70 days of deslorelin implantation none of the animals ovulated, despite of the implant not suppressing all follicular development. This ultrasonographic finding was confirmed by the results of P4 plasma concentrations, which was kept in average below 0,16 ng/mL. During the last 20 days of implantation, four animals presented follicular development with maximum diameter ranging through 0,4 to 0,6 cm while in the three remaining animals the observed diameter ranged through 0,9 to 1,2 cm. The secretion of LH and FSH was not entirely suppressed during the study. After the removal of the deslorelin subcutaneous implant (Suprelorin® 4,7 mg), the period of... (Complete abstract click electronic access below) / Mestre
43

Avaliação da integração de implantes de silicone com superfícies lisa, texturizada e de poliuretano em cavidades anoftálmicas evisceradas de coelhos /

Abreu, Cristiano Ricardo de. January 2014 (has links)
Orientador: Silvana Artioli Schellini / Banca: Mariangela Marques / Banca: Suzana Mayayoshi / Banca: Giovanni Viana / Banca: Aristides Palhares / Resumo: Objetivo: Visando acrescentar novos conceitos na área da reconstrução da cavidade anoftálmica e utilizando conhecimento adquirido na Cirurgia Plástica, o presente estudo foi desenvolvido com o objetivo de avaliar a integração dos implantes hemi-esféricos de silicone em gel coesivo com três diferentes tipos de superfície (lisa, texturizada e de poliuretano), empregados para devolução do volume perdido de cavidades evisceradas de coelhos. Método: Foram utilizados 45 coelhos albinos, machos, espécie Orictolagus cuniculus, que tiveram o olho direito eviscerado, sendo feita a colocação de implantes hemi-esféricos de silicone em gel coesivo na cavidade orbitária. Os implantes diferiram entre si pelos revestimentos, que foram de três tipos: liso (Grupo (GI)), texturizado (GII) ou de poliuretano (GIII). Cada grupo foi constituído por 15 animais, sendo que 5 animais de cada grupo foram sacrificados 7 (M7), 30 (M30) ou 90 (M90) dias após a cirurgia de evisceração e colocação do implante. Foram realizadas avaliações clínica, laboratorial (exame de creatinina sérica e de 2,4 toluenodiamina - TDA), tomográfica usando o programa OsiriX® (posição e área do implante), histológica e morfométrica (medida da espessura da pseudocápsula e da celularidade). Os resultados obtidos foram submetidos à avaliação estatística comparando-se os grupos com diferentes tipos de revestimentos dos implantes, nos três momentos de sacrifício. Resultados: Houve boa evolução em todos os grupos experimentais, não se observando extrusão ou processos infecciosos ao longo do período experimental. A avaliação histológica mostrou que os implantes de superfície lisa (GI), texturizada (GII) ou de poliuretano (GIII) tiveram boa integração tecidual, com maior reação inflamatória e espessura da pseudocápsula nos implantes de GIII. No exame tomográfico, os implantes de GI mudaram mais de posição e foram evidenciadas deformidades nos ... / Abstract: Purpose: In order to add new concepts in the area of the anophthalmic socket reconstruction and using knowledge acquired in Plastic Surgery, this study was developed to evaluate the integration of hemi-spherical cohesive gel silicone implants coated by three different surfaces (smooth, textured and polyurethane) used to replace the missed volume in eviscerated cavities of rabbits. Methods: Forty-five albino male rabbits of the specie Oryctolagus cuniculus had their right eye eviscerated and hemi-spherical cohesive gel silicone implants were inserted in the orbital socket to replace volume. The implants were coated by three different types of surfaces: smooth (Group (IG)), textured (GII) or polyurethane (GIII). Each group was composed by 15 animals and five of them in each group were sacrificed seven (M7), 30 (M30) and 90 (M90) days after evisceration surgery and implant placement. Clinical and laboratorial assessments (creatinine test and 2,4 toluene diamine- TDA), histologic and morphometric exam (measurement of the thickness of pseudocapsule and cellularity) and tomographic (CT scan) evaluation using the OsiriX program (position and area of the implant) were performed. The results were analyzed statistically comparing groups that differ by the coating of implants in the three moments of sacrifice. Results: There was good evolution in all experimental groups and extrusion or infectious processes was not observed throughout the experimental period. Histological evaluation showed that implants with a smooth (GI), textured (GII) or polyurethane surface (GIII) had good tissue integration and GIII implants showed greater inflammatory reaction and thickness of the pseudocapsule. On CT scan, the GI implants changed over position and deformities were observed in the GIII implants. Using OsiriX® program was possible to evaluate the area of the implants. The 2,4 TDA was not found in any of the experimental groups. Conclusion: Cohesive gel ... / Doutor
44

Metodologia para desenvolvimento de implantes cranianos personalizados / Methodology for development of cranial customized implants

Saura, Carlos Eduardo, 1958- 26 August 2018 (has links)
Orientador: Cecilia Amélia de Carvalho Zavaglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T13:44:25Z (GMT). No. of bitstreams: 1 Saura_CarlosEduardo_D.pdf: 6545554 bytes, checksum: 6e172e4f392006d2c809c0f86185aff1 (MD5) Previous issue date: 2014 / Resumo: Esta tese demonstra os benefícios relacionados ao uso efetivo de uma metodologia que visa guiar todo processo de cranioplastia, utilizando-se de implantes personalizados para regenerar falhas cranianas. Sabe-se que diferentes técnicas de implante, geralmente atreladas a casos médicos específicos, têm sido aplicadas já há vários anos. Isso acarretou uma grande e valiosa evolução nesta área, porem também gerou dúvidas sobre qual técnica seria a mais eficaz a ser empregada em cada caso. A metodologia aqui explanada visa auxiliar desde o diagnóstico, passando pela coleta de imagens médicas, elaboração do modelo tridimensional do paciente contendo sua falha óssea, modelamento do implante, criação física do mesmo através do uso da Manufatura Aditiva (MA) e finalmente a aplicação do implante no paciente. Esta metodologia é aplicável aos implantes personalizados metálicos, poliméricos ou cerâmicos, e direcionados para serem executados pela tecnologia de MA que também é conhecida como prototipagem rápida. Na origem do processo está a captura de imagens médicas do crânio e da falha óssea através de tomografia computadorizada. As fatias tomográficas são transformadas em um modelo tridimensional no sistema InVesalius® (CTI ¿ Brasil) e os arquivos neles criados são transferidos para um programa específico utilizado na MA chamado Magics RP ¿, nele então o biomodelo tridimensional é analisado e preparado para execução de um modelo físico. Na criação do implante em caso de falhas pequenas ou médias que estão alocadas totalmente em um dos hemisférios do crânio pode-se usar apenas o Magics RP ¿. Em casos de falhas grandes laterais (que invadem o hemisfério oposto) ou frontais, utiliza-se o programa de CAD, neste caso o SolidWorks ¿, no qual são trabalhadas superfícies e sólidos com o objetivo de reconstruir fielmente o perfil craniano através do implante que está sendo desenvolvido. Os resultados obtidos com o uso da metodologia são implantes de adequação perfeita, diminuição no tempo de cirurgia e rápida recuperação e integração social do paciente. Conclui-se que o grande benefício de se ter uma Metodologia para Desenvolvimento de Implantes Cranianos Personalizados é que esta orienta através de um conjunto de diretrizes as equipes multidisciplinares compostas de cirurgiões, radiologistas, técnicos e engenheiros, estejam orientadas e preparadas a atender a crescente necessidade de implantes cranianos personalizados / Abstract: This thesis demonstrates the benefits related to the effective use of a methodology that aims to guide the whole process of cranioplasty, using custom implants to regenerate cranial defects. Known is that different implant techniques, usually linked to specific medical cases, has being applied for several years. This led to large and valuable developments in this area, but also raised questions about which one would be the most effective technique employed in each case. The methodology here explained aims to give an assistance from diagnosis, through the collection of medical imaging, three-dimensional model of patient preparation containing your bone gap, modeling of the implant, creating physically the implant with the Additive Manufacturing (MA) and finally the application of implant into the patient. This methodology is applicable to custom metallic implants, polymeric or ceramic and produced with MA technology, which is also known as rapid prototyping. The process is capturing medical images of skull and bone gap through computerized tomography. Tomographic slices are transformed into a three-dimensional model in InVesalius ® system (CTI-Brazil) and the files in them created are transferred to a specific program used in MA, called Magics RP ¿, it then the three-dimensional biomodelo is parsed and prepared for execution of a physical model. In the creation of the implant in case of small or medium failures allocated fully in one of the skull hemisphere can only use the Magics RP ¿. In cases of large lateral faults (invading the opposite hemisphere) or front, we use CAD program, in this case the SolidWorks ¿, in which we work with surfaces and solids in order to be faithfully reconstruct cranial profile through the implant is being developed. The results obtained with the use of the methodology are perfect adequacy implants, decreased at the time of surgery and speedy recovery and social integration of the patient. Concluded is that the major benefit of having a methodology for developing Custom Cranial Implants is that this leads you through a set of guidelines the multidisciplinary teams composed of surgeons, radiologists, technicians and engineers, are targeted and prepared to meet the growing need for custom cranial implants / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
45

Determinação da posição de bobinas implantáveis via sistema de transferência de energia sem fio / Implantable coil determination position via wireless power transfer system

Garcia, Lucas Ricken 26 September 2016 (has links)
CNPq / Este trabalho apresenta o estudo de um método para a determinação da posição e orientação de uma bobina implantável em relação à bobina transmissora localizada externamente ao paciente. No aspecto elétrico, conhecer a posição e orientação da bobina implantada permite um maior domínio sobre o posicionamento do enlace e, consequentemente, das características de eficiência e potência entregue ao secundário, i.e. ao IMD. Já no aspecto clínico, detectar e determinar a posição da bobina implantável e, se possível, do IMD, pode auxiliar na determinação de possíveis movimentações do dispositivo na região implantada que podem influenciar o seu desempenho. Neste sentido, realizou-se análises teóricas a cerca da indutância mútua, do coeficiente de acoplamento magnético e de sistemas de transferência de energia sem fio (WPT) a duas bobinas. Por meio do modelo matemático implementado no software Matlab e o projeto experimental de sistemas de WPT a duas bobinas, avaliou-se a influência de desalinhamentos laterais e angulares sobre o acoplamento magnético. A partir das características observadas, descreveu-se os procedimentos necessários para estimar a posição e orientação relativa da bobina do dispositivo implantável apenas mensurando os parâmetros elétricos do primário. Em uma avaliação preliminar, por meio de testes virtuais, observou-se um erro médio e incerteza padrão na determinação da posição relativa de 2,4 mm e 1,1 mm, respectivamente, que se comparada às dimensões das bobinas (40 mm de diâmetro para bobina externa e 5,5 mm para a bobina implantável) indicam uma exatidão adequada. Para a determinação do ângulo relativo o método também apresentou resultados promissores, uma vez que o erro médio foi de 7º e a incerteza padrão obtida de 8,2º. Desta forma, o método estudado possibilita o desenvolvimento de equipamentos para determinação da posição e orientação relativa de uma bobina implantável mensurando apenas a corrente no primário, sem a necessidade de circuitos adicionais no IMD ou a utilização de equipamentos de imagem médicos. / This paper presents the study of a method for determining the implanted coil position and orientation relative to the transmitter coil externally located to the patient. In the electrical aspect, knowing the implanted coil position and orientation allows greater control over the placement of the link and thus the efficiency of features and power delivered to the secondary, i.e. the IMD. In the clinical aspect, detect and determine the implantable coil position, if possible, the IMD can assist in determining possible device movements in the implanted area that can influence their performance. In this sense, a theoretical analysis about the mutual inductance, the magnetic coupling coefficient and two coils wireless power transfer (WPT) systems was realized. Through mathematical model implemented in Matlab and experimental design of two coil WPT systems, the influence of lateral and angular misalignment on the magnetic coupling was assessed. From the observed characteristics, was described the necessary procedures to estimate the relative position and orientation of the implantable device coil only measuring the primary electrical parameters. In a preliminary evaluation, through virtual testing, there was an average error and standard deviation in determining the relative position of 2.4 mm and 1.1 mm, respectively, compared to the dimensions of the coils (40 mm diameter to external coil and 5.5 mm for implantable coil) indicate adequate accuracy. To the relative angle the method also yielded promising results, since the average error was 7° and the standard deviation obtained 8.2°. Thus, the method studied enables the development of equipment for determining the implanted coil relative position and orientation measuring only the primary current without the need for additional circuitry in IMD or the use of medical imaging equipment.

Page generated in 0.0656 seconds