41

Microzonificación Sísmica del Sector Sur Poniente de Santiago, Comunas Buin y Paine

Brantt Hidalgo, Cristina Estefania January 2011 (has links)
El pasado terremoto del 27/02/2010 de magnitud Mw 8,8, afectó una extensa zona de Chile central. Dentro de las zonas que presentaron daño, se cuentan las comunas de Buin y Paine de la Región Metropolitana. Tras el sismo se generaron cuantiosos estudios, de diversas disciplinas, orientados a complementar el conocimiento del comportamiento sísmico de los suelos. En el marco anterior, el presente trabajo de título pretende ser uno de los tantos aportes, teniendo como objetivo general definir las unidades geológicas relacionadas con la respuesta sísmica observada en las comunas de Buin y Paine. A través de la clasificación del relleno cuaternario según su respuesta sísmica, se busca proveer de información útil a las autoridades para la planificación territorial de la zona. Para tales efectos, el estudio contempla el análisis geológico del relleno cuaternario y la evaluación de frecuencias fundamentales del suelo, mediante el método Nakamura, sumado a la incorporación de antecedentes de daños a través de la observación en terreno y estudios de intensidades. En el área de estudio se reconocen depósitos aluviales, fluviales y coluviales, constituidos principalmente por intercalaciones de gravas en matriz areno-limo-arcillosa, con variaciones de su granulometría y espesor. En base a la granulometría dominante y a la geomorfología, se definen unidades geológicas. En la definición de estas unidades se considera la información obtenida de pozos y calicatas disponibles. Los daños más severos, producto del terremoto del 2010, ocurrieron principalmente en las localidades de Valdivia de Paine, Rangue, Abrantes, Pintué y Champa. El daño en estas tres últimas localidades, se asocia a procesos de licuefacción. En cuanto a los resultados obtenidos mediante la técnica de Nakamura, se muestran tres dominios con diferentes tipos de señales: (a) señal plana, ausencia de pico; (b) tres picos de amplitud variable, en las frecuencias 0,5, 2,0 y 5,0 Hz y (c) dos picos de amplitud media, entre las frecuencias de 1,0 y 2,0 Hz. Finalmente, con los resultados obtenidos se distinguieron cuatro zonas de diferente respuesta sísmica: (1) Buena respuesta sísmica: asociada a depósitos principalmente compuestos de gravas, con señales correspondientes al dominio (a); (2) Regular respuesta sísmica: asociada a depósitos coluviales y de ceniza, caracterizadas por una señal correspondiente a los dominios (a) y (c); (3) Mala respuesta sísmica: asociada a depósitos fluviales y de remoción en masa, y (4) Mala respuesta sísmica – suelos potencialmente licuables: asociada a depósitos constituidos por arenas y sedimentos finos con nivel freático somero, relacionadas al dominio de señal (b). Esta última presentó fenómeno de licuefacción en ciertas localidades.
42

Estudio de Muelle Transparente de Contenedores con Aislación Sísmica

Castro Gutiérrez, Francisco Gabriel January 2011 (has links)
No autorizada por el autor a ser publicada a texto completo / El objetivo general del presente trabajo de título es evaluar la implementación de un sistema de aislamiento sísmico en una estructura de pilotes de acero-tablero de hormigón de un muelle transparente típico para transferencia de carga de contenedores. El estudio se focaliza en el caso de los sitios 3, 2 y 1 del Puerto de Valparaíso. Inicialmente, se evalúa un aumento en seguridad sísmica y operativa del terminal post-sismo de gran magnitud, para luego evaluar la factibilidad de operar, tanto grúas de mayor rendimiento para naves Post-Panamax., así como grúas de menor certificación sísmica, más económicas y disponibles en el mercado. En el comercio marítimo, la seguridad y confiabilidad de mantener operativo los terminales portuarios post sismo de gran magnitud, surge como una necesidad en lo que significa reducir el endeudamiento en primas y seguros, por parte de las empresas portuarias para enfrentar estos desastres eventuales. Por otro lado, los principales países proveedores de equipos industriales en el mundo, poseen una línea de fabricación cuya demanda esta orientada principalmente a países de baja actividad sísmica. La demanda internacional de equipos certificados para operar en zonas sísmicas altas es menor, por lo que adquirir equipamiento de este tipo, implica diseñar y construir, por parte de los proveedores, fuera de su línea de producción masiva, hecho que resulta en mayores costos y plazos de entrega. En el estudio se modeló la estructura de muelle transparente con dos grúas ZPMC Post-Panamax, de forma convencional y con aislamiento sísmico. Se determinó la estructuración adecuada en planta de aisladores sísmicos y se diseño el sistema de aislamiento de acuerdo a la norma Nch2745; se verificó el diseño de forma lineal y no-lineal. Se realizó un estudio de costos directos e indirectos para determinar el porcentaje de incidencia en el proyecto total. Como resultado se obtuvo un sistema de aislamiento hibrido compuesto por aisladores elastoméricos y con pilotes verticales. Se logró una disminución de aceleraciones sísmicas horizontales de un 80% en el muelle y de un 90% en las grúas. El aislamiento sísmico posibilita la instalación de equipamiento estándar en zonas sísmicas altas y tiene una baja incidencia en la inversión, logrando un aumento considerable de la seguridad sísmica portuaria, para un sismo de gran magnitud. Se concluye que es técnica y económicamente factible disponer de aislamiento sísmico en estructuras de muelle transparente, y que la alternativa desarrollada es una solución para el diseño sísmico en Chile en infraestructura portuaria.
43

Análisis sísmico comparativo entre un edificio de gran altura con sistema convencional y disipadores de energía

Oblitas Gonzales, Mario January 2024 (has links)
El Perú está ubicado en la franja del cinturón de fuego donde han sucedido más del 80% de sismos de gran magnitud. Entre los sismos más relevantes se tuvo en abril del 2016 en Manta Ecuador y el de Concepción Chile en febrero del 2010 donde colapsaron edificaciones de varios niveles ocasionando 602 y 525 muertes respectivamente. Por lo tanto, es de mucha importancia implementar sistemas de protección sísmica a las edificaciones para disipar la energía ante un evento sísmico moderado a severo y salvaguardar la vida de sus ocupantes. Teniendo en cuenta ello en la presente investigación se hace una comparación entre un sistema convencional y otro implementado con disipadores de fluido viscoso Chevron (DFVC) en un edificio de gran altura en la ciudad de Chiclayo. Como primer paso de la metodología se hizo la caracterización del sitio a través del ensayo de penetración estándar (SPT), estudios geofísicos de refracción sísmica (RS) y análisis multicanal de ondas superficiales (MASW). Posteriormente se realizó el modelado y análisis dinámico modal espectral (ADME) según la norma E.030 para la estructura convencional y el análisis tiempo historia no lineal (ATHNL) para la estructura implementada con DFVC con la Norma ASCE7-16. Como resultados se determinó un suelo S₂, los desplazamientos de la estructura con DFVC se redujeron en 66.66 % y 56.46 % estos disipadores absorben un 60.38 % y 61.26 % de la energía del sismo en dirección X-X e Y-Y respectivamente. / Peru is located in the belt of fire where more than 80% of large earthquakes have occurred. Among the most relevant earthquakes were in April 2016 in Manta Ecuador and Concepción Chile in February 2010 where multi-level buildings collapsed, causing 602 and 525 deaths respectively. Therefore, it is very important to implement seismic protection systems in buildings to dissipate energy in the event of a moderate to severe seismic event and save the lives of its occupants. Taking this into account, in the present investigation, a comparison is made between a conventional system and another implementation with Chevron viscous fluid dissipators (DFVC) in a high-rise building in the city of Chiclayo. As the first step of the methodology, the characterization of the site was carried out through the standard (SPT) penetration test, geophysical studies of seismic refraction (RS) and multichannel analysis of surface waves (MASW). Subsequently, spectral modal dynamic modeling and analysis (ADME) was carried out according to the E.030 standard for the conventional structure and the nonlinear time history analysis (ATHNL) for the structure implemented with DFVC with the ASCE7-16 Standard. As a result, a floor S₂ is calculated, the displacements of the structure with DFVC were reduced by 66.66% and 56.46% these dissipators absorbed 60.38% and 61.26% of the earthquake energy in the X-X and Y-Y direction respectively.es el resumen traducido al idioma inglés.
44

Comportamiento de un Tramo Elevado de la Línea 5 del Metro durante el Sismo del 27/02/2010

Neira Sepúlveda, Carlos Roberto January 2011 (has links)
Este trabajo tiene como objetivo analizar el comportamiento de un tramo elevado de la línea 5 del Metro de Santiago durante el sismo del 27/02/2010. En dicho tramo, existe una red de acelerómetros de 12 sensores, que registró dicho sismo, que es el de mayor magnitud que ha afectado a la estructura. La estructuración del tramo es tipo viaducto. Cuenta con un sistema de aislación consistente en placas de neopreno reforzadas, apoyadas sobre capiteles de hormigón postensado soportados por pilares tipo cajón. Sobre las placas de neopreno, se apoyan vigas de hormigón pre y postensado que soportan la losa de hormigón postensado del viaducto. Este estudio comprende un análisis de los registros obtenidos para el sismo del 27/02/2010, tanto en el espacio del tiempo, como en el espacio de las frecuencias. Se comparan las aceleraciones máximas en campo libre, cepa y superestructura; y se determinan desplazamientos por doble integración de los registros en el tiempo. Del análisis de aceleraciones máximas se desprende que en dirección longitudinal, sobre el tablero la aceleración es menor que en la cepa y en las direcciones transversal y vertical son mayores. Además, existe amplificación de las aceleraciones en el tope de la columna, respecto a la base de ésta, en ambas direcciones horizontales. En dirección transversal, es notorio el cambio de frecuencias predominantes entre la viga y la cepa. A través de un análisis espectral, se identifican tres modos en la dirección longitudinal: 1,36 Hz, 2,47 Hz y 6,96 Hz; tres modos en la dirección transversal: 1,25 Hz, 3,03 Hz y 6,76 Hz; y dos modos en la dirección vertical: 5,04 Hz y 7,21 Hz. Además, se calibra un modelo computacional considerando comportamiento no lineal, de manera que reproduzca la respuesta real de la estructura durante el evento sísmico mencionado. Esto se realiza variando la rigidez de los resortes horizontales que modelan el suelo, la rigidez de los apoyos de neopreno, la rigidez del hormigón de la estructura, y el amortiguamiento modal de la estructura.
45

Análisis de Métodos de Identificación de Variación de Propiedades Dinámicas

Hernández Prado, Francisco Javier January 2009 (has links)
No description available.
46

Análisis del comportamiento sísmico y reforzamiento estructural del bloque I de Centro Comercial Ripley del distrito y provincia Chiclayo, departamento de Lambayeque, 2017

Guerrero La Chira, Maria del Carmen January 2019 (has links)
La siguiente investigación parte de la construcción de una edificación de acero con uso de centro comercial cuyo antecedente es un patrimonio cultural de adobe la que actualmente está convertido solo en una fachada en condiciones estructurales desconocidas, sabiendo solo que se cuenta con una junta mínima entre fachada y estructura de acero se analizó el comportamiento sísmico de la estructura interior de acero para controlar sus desplazamientos para que este no sea motivo de derrumbe de la fachada de adobe durante un sismo, para ello se propuso según los resultados del análisis un reforzamiento estructural.
47

Análisis y diseño comparativo entre un edificio con amortiguadores de masa sintonizada y un edificio convencional en la ciudad de Chiclayo

Llontop Izquierdo, Kevin Antonio January 2023 (has links)
Perú está ubicado en uno de los continentes que presentan mayor actividad sísmica causando muchas pérdidas humanas y daños excesivos en elementos estructurales y no estructurales, así mismo para disminuir estos movimientos sísmicos se ha estudiado un sistema de protección sísmica llamado Amortiguamiento de masa sintonizada con el fin de aumentar el desempeño sísmico, El edificio analizado es: las dos torres de Salaverry ubicado en la ciudad de Chiclayo del territorio Peruano, Dicho amortiguamiento de masa sintonizada se ha colocado en la parte final del edifico con el propósito de disminuir los desplazamientos laterales ,Los Análisis utilizados han sido el Estatico,Dinamico Y el Análisis tiempo historia cumpliendo también con los requisitos de la Norma E030 , Para el análisis tiempo historia se han seleccionado los sismos ocurridos en Piura el 18 de octubre de 2021 y el 3 de febrero Condorcanqui Amazonas y uno de los sismos más fuertes de Perú que es de lima 1974, de los resultados obtenidos se ha concluido que este sistema de amortiguamiento de masas sintonizada al incorporar a edificios reduce considerablemente los desplazamientos laterales, resultando ser uno de sistemas de protección sísmica favorable / Peru is located in one of the continents that present the greatest seismic activity, causing many human losses and excessive damage to structural and non-structural elements. Likewise, in order to reduce these seismic movements, a seismic protection system called Tuned mass damping has been studied in order to increase the seismic performance, The analyzed building is the two Salaverry towers located in the city of Chiclayo in the Peruvian territory, This tuned mass damping has been placed in the final part of the building with the purpose of reducing lateral displacements, The Analyzes used have been the Static, Dynamic and Time History Analysis, also complying with the requirements of Standard E030. For the time history analysis, the earthquakes that occurred in Piura on October 18, 2021 and February 3, Condorcanqui Amazonas and one of the strongest earthquakes in Peru, which is from Lima 1974, of the results obtained It has been concluded that this tuned mass damping system when incorporated into buildings considerably reduces lateral displacements, turning out to be one of the favorable seismic protection systems.