• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 639
  • 7
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 656
  • 403
  • 112
  • 66
  • 62
  • 47
  • 46
  • 43
  • 39
  • 39
  • 37
  • 36
  • 33
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Sistema de aquisição do ciclo pressão-volume cardíaco por métodos não-invasivos

Slomp, Marcio January 1999 (has links)
A aquisição do ciclo pressão-volume é de grande importância para diagnóstico de cardiopatias e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos hoje utilizados são caros e agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, o ciclo pressão-volume do ventrículo esquerdo de pacientes humanos. Isto consiste na aquisição dos sinais P(t) e V(t) simultaneamente e a apresentação de um gráfico P(V). Para tanto, após a revisão bibliográfica, decidiu-se utilizar a ecocardiografia com detecção automática de bordos, para obtenção do volume ventricular e a medição da onda de pressão transmitida através da artéria braquial para um manguito inflado com ar, conectado a um transdutor piezo-resistivo em ponte. A aquisição da pressão pelo método não-invasivo é comparada a dados resultantes da aquisição invasiva da pressão arterial por catéter intra-aórtico que é considerado padrãoouro. Os sinais são condicionados e digitalizados em uma placa de aquisição com conversor A/D de 8 bits e micro controlador 80c196. Os dados digitalizados são então enviados serialmente para um computador onde são gerados os gráficos. Obteve-se de cinco pacientes nove aquisições simultâneas da pressão invasiva através de catéter intra-aórtico e do protótipo desenvolvido resultando concordância segundo o método de Bland e Altman (1986) (r=0,989; d + 2s= 6,52; d - 2s =-6,07), comprovando a eficiência do método de aquisição. Obteve-se resultado satisfatório também quanto à operação sistema desenvolvido pois foram realizadas dez aquisições em cinco pacientes, registrando-se gráficos bastante similares aos apresentados na literatura disponível. / The pressure-volume loop acquisition is very important for diagnoses of cardiac abnormalities and principally to attend the evolution after interventions, but the methods presently used are expensive and aggressive to the patients. Then, due to these reasons their application is reduced. This research has been made with the intention of getting, for non-invasive methods, the left ventricular pressure-volume loop in human patients. This means that it is necessary to acquire the signals P(t) and V(t) and draw a graphic P(V). So, after the bibliographical review it was decided to use echocardiographic apparatus with automated border detection for the obtainment of the ventricular volume and the measurement of the pressure wave transmitted through the brachial artery for a compression cuff, inflated with air, connected to a piezo-resistive transducer. The pressure acquisition by a non-invasively method was compared with an invasively acquired data from arterial pressure performed by an intra-aortic catheter that is used as a golden standard. Nine acquisitions from five patients showed that there is a good correlation between the two methods (r=0,989; d + 2s= 6,52; d - 2s =-6,07) (Bland and Altman, 1986). The signals are conditioned and digitalized on an acquisition board with 8 bit A/D converter and micro controller 80c196. This digitalized data are sent through a serial port to a computer where the graphics are displayed. We obtained ten P(V) loops from five patients showing good similarity with the studied literature.
162

Um método para detectar falhas incipientes em máquinas rotativas baseado em análise de vibração e lógica Fuzzy

Marcal, Rui Francisco Martins January 2000 (has links)
Este trabalho apresenta um método para detectar falhas no funcionamento de máquinas rotativas baseado em alterações no padrão de vibração do sistema e no diagnóstico da condição de operação, por Lógica Fuzzy. As modificações ocorridas são analisadas e servem como parâmetros para predizer falhas incipientes bem como a evolução destas na condição de operação, possibilitando tarefas de manutenção preditiva. Utiliza-se uma estrutura mecânica denominada de Sistema Rotativo (Figura 1), apropriada para as simulações das falhas. Faz-se a aquisição de dados de vibração da máquina usando-se um acelerômetro em chip biaxial de baixa potência. As saídas são lidas diretamente por um contador microprocessador não requerendo um conversor A/D. Um sistema de desenvolvimento para processamento digital de sinais, baseado no microprocessador TMS320C25, o Psi25, é empregado na aquisição dos sinais de vibração (*.dat), do Sistema Rotativo. Os arquivos *.dat são processados através da ferramenta matemática computacional Matlab 5 e do programa SPTOOL. Estabelece-se o padrão de vibração, denominado assinatura espectral do Sistema Rotativo (Figura 2) Os dados são analisados pelo sistema especialista Fuzzy, devidamente calibrado para o processo em questão. São considerados, como parâmetros para a diferenciação e tomada de decisão no diagnóstico do estado de funcionamento pelo sistema especialista, a freqüência de rotação do eixo-volante e as amplitudes de vibração inerentes a cada situação de avaria. As falhas inseridas neste trabalho são desbalanceamentos no eixovolante (Figura 1), através da inserção de elementos desbalanceadores. A relação de massa entre o volante e o menor elemento desbalanceador é de 1:10000. Tomando-se como alusão o conhecimento de especialistas no que se refere a situações normais de funcionamento e conseqüências danosas, utilizam-se elementos de diferentes massas para inserir falhas e diagnosticar o estado de funcionamento pelo sistema fuzzy, que apresenta o diagnóstico de formas qualitativa: normal; falha incipiente; manutenção e perigo e quantitativa, sendo desta maneira possível a detecção e o acompanhamento da evolução da falha.
163

Projeto e avaliação de um canal de medição de bioimpedâncias

Porto, Rodrigo Wolff January 2009 (has links)
Esta dissertação trata do projeto e avaliação de um canal de medição de bioimpedâncias multifrequencial cujo objetivo é a medida em módulo e fase de impedâncias até 1 k com desempenho reportado nas freqüências 100 kHz, 300 kHz e 1 MHz. Um modelo teórico foi desenvolvido para cada etapa do canal de medição incluindo as não idealidades dos componentes utilizados na implementação prática. A análise da sensibilidade à variação de parâmetros e da propagação de incertezas nas etapas do sistema foi realizada juntamente com a avaliação experimental da exatidão e precisão do protótipo desenvolvido. O circuito proposto apresenta incerteza experimental 0,008% nas medidas de amplitude e 0,05% nas medidas de fase. / This dissertation deals with the project and evaluation of a multifrequency bioimpedance measurement channel whose objective is to obtain the measure in module and phase of load impedances up to 1 k with performance reported in 100 kHz, 300 kHz and 1 MHz. A theoretical model was developed for each stage of the measurement channel having included non-idealities of the components used in the practical implementation. The sensitivity analysis with respect to parameter variation and uncertainty analysis in the stages of the system was carried through together with the experimental evaluation of the accuracy and precision of the developed prototype. The considered circuit presents experimental uncertainty of 0.008% in the measures of amplitude and 0.05% in the measures of phase.
164

Medidor não invasivo de alta tensão, tempo e exposição em aparelhos de raios x

Laan, Flavio Tadeu van der January 1996 (has links)
Neste trabalho, propõe-se desenvolver um medidor para controle de qualidade em RX diagnóstico, que permite medidas rápidas de alta tensão, tempo e exposição em aparelhos de RX, de modo não invasivo, baseado na leitura frontal do feixe. A unidade é composta de dois diodos fotovoltaicos como transdutores, amplificadores de corrente, como condicionadores de sinais e de um sistema de aquisição e processamento, para o tratamento do sinal digital. 0 medidor permite a medida da alta tensão de pico (kVp), taxa de exposição (R/min), e do tempo de exposição (s) em aparelhos de RX, na faixa de 50 a 150 kVp. As medidas são realizadas num sistema microprocessado, programadas por teclado e apresentadas num display alfanumérico. São memorizadas e transferidas a um microcomputador por meio de uma saída serial / This work contains a development of an instrument for non invasive as well fast measurement of essential parameters related to quality control of X-ray equipment's using only the frontal reading of the beam intensity. The unit is composed of a data acquisition system for reading two Photovoltaic diodes sensor, for measurement of Peak Kilovoltage (kVp), Exposure Rate (R/min) and Exposure Time (s) of the x-ray equipment. The measurements are performed with microprocessed instrumentation, with programmed keyboard ability, alphanumeric display, memory data storage and serial output to microcomputer connection.
165

Estudo e desenvolvimento de um sensor de CO2 de baixo custo

Schaeffer, Robson Dagmar January 2004 (has links)
Este trabalho descreve um estudo e desenvolvimento de um sensor de dióxido de carbono (CO2), de baixo custo, para monitoramento da qualidade do ar em ambientes climatizados. O sensor aqui proposto baseia-se na técnica de absorção em infravermelho não dispersivo (NDIR). Este trabalho avalia alguns métodos já empregados e propõe um modelo alternativo visando uma solução de baixo custo que possa ser incorporada a sistemas de monitoramento e/ou condicionamento existentes, permitindo o controle do teor de CO2. A metodologia inclui o estudo dos diferentes tipos de sensores de CO2, a seleção da técnica mais apropriada para medição, o estudo das alternativas para implementação da técnica selecionada, o desenvolvimento, testes e avaliações da solução. Especificamente desenvolveu-se uma solução em termos de sensor de CO2 que utiliza componentes comerciais, sendo facilmente reprodutível e de custo reduzido. O sensor desenvolvido tem faixa de medição entre 330 a mais de 10000 ppm, com resolução estimada em torno de 20 a 30 ppm, com erro em relação ao padrão menor que 10% da medição ou 150 ppm,o que for maior.
166

O valor da video-eletrencefalografia na localização da zona de início ictal durante a avaliação para o diagnóstico e tratamento cirúrgico de epilepsias refratárias ao tratamento medicamentoso

Volkmann, Ana Fátima January 2014 (has links)
Orientador : Prof. Dr. Carlos Eduardo Soares Silvado / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Medicina Interna. Defesa : Curitiba, 18/12/2014 / Inclui referências : f. 48-53 / Resumo: Aproximadamente 30% das pessoas com epilepsia (PCE) não controlam as crises epilépticas apenas com medicação antiepiléptica, necessitando realizar uma avaliação para confirmação diagnóstica e eventual tratamento cirúrgico de epilepsia (ADCE). O ponto crucial da ADCE é o registro com vídeo-eletrencefalograma (VEEG) das crises típicas e a definição da região cerebral onde se iniciam as crises epilépticas (zona de início ictal - ZII). Porém a definição sobre a duração, número de crises necessárias para uma adequada localização da ZII e as possíveis intercorrências durante o VEEG não estão bem determinadas, o que tem implicações óbvias no planejamento das avaliações das epilepsias refratárias. Com o objetivo de: a) identificar o valor do VEEG na classificação das crises epilépticas e na localização da ZII; b) identificar a duração mínima do VEEG para registrar um número suficiente de crises epilépticas típicas; c) avaliar o risco de intercorrências durante o VEEG; d) definir o período do dia com maior ocorrência de crises epilépticas e e) comparar as características acima entre os diversos grupos de epilepsia de ADCEs realizados durante a avaliação para tratamento cirúrgico de epilepsia no Serviço de Epilepsia e EEG do Hospital de Clínicas UFPR. Foram revisados as fichas técnicas, laudos e prontuários de 1.044 VEEGs, sendo incluídos aqueles com duração superior a 24 h contínuas e excluídos os com dados incompletos, com registro exclusivo de eventos não epilépticos; que utilizaram eletrodos intracranianos e os registros com mais de 10 crises epilépticas. As ADCE foram classificadas em 5 grupos conforme a classificação final do tipo de epilepsia (anterior - ANT, temporal - TEMP, posterior - POST, não definida - ND e generalizada - GEN). Foram incluídos 655 exames de VEEGs, sendo que 57% deles em homens. A duração média do registro foi de 56,7 ± 46,5 h nas GEN e de 99,9 ±16,4 nas epilepsias localizadas, sendo de 102,5 ± 62,5 h no grupo TEMP (524 VEEGs). Durante o VEEG a medicação antiepiléptica foi reduzida em 50,6% das TEMP; 48,6% das ANT, 33,3% das POST e em 50% das GEN. As intercorrências ocorreram com maior frequência no grupo GEN com 5,2% de crises não registras e no grupo POST 0,9% das crises com estado de mal/crise prolongada. A duração média até o registro da primeira crise considerada ideal foi de 56,6 ± 52,1 h nas ANT; 53,2 ± 48,5 h nas TEMP; 39.7 ±32,4 nas POST. A definição da localização da zona de início ictal foi possível em 67,7% das TEMP, 63% das POST, 40% das ANT. Entre as epilepsias localizadas 70,1% ocorreram durante a vigília, com 24,4% pela manhã; 33,7% à tarde e 41,9% à noite. Pelos resultados estima-se que para a localização da ZII deve-se realizar VEEG com duração variando de 53 h (1ª crise ideal) a 79 h (última crise), incluindo o período noturno (42% das crises). Esses dados serão úteis no planejamento das avaliações para o diagnóstico e tratamento cirúrgico de epilepsia. Palavras-chave: Epilepsia, Vídeo-eletrencefalograma, Vídeo-EEG, Zona de Início Ictal, Tratamento Cirúrgico de Epilepsia. Diagnóstico de Epilepsia. / Abstract: Approximately 30% of people with epilepsy (PWE) cannot control their seizures only with antiepileptic medication, needing to perform an evaluation to confirm the diagnosis and possible surgical epilepsy treatment (DSET). DSET's crucial point is recording the typical seizures with video-EEG (VEEG) and defining the cortical area where the episodes begin (ictal onset zone - IOZ). However, the definition around the duration and number of necessary seizures necessary for an adequate location of the IOZ and possible complications during the VEEG are not well determined, and this has obvious implications in planning the evaluation of refractive epilepsies. With the goals of identifying the a) value of VEEG in the classification of epileptic seizures and location of the IOZ; b) identifying the minimum duration of VEEG to record a sufficient number of typical epileptic seizures; c) assess the risk of intercorrências during the VEEG; d) define time of day with the largest occurrences of epileptic seizures; and e) compare the characteristics above between the diverse groups of epilepsies of DSETs performed during evaluation for epilepsy surgery in the Division of Epilepsy and EEG Hospital Clinical UFPR. We reviewed medical and VEEG records of 1044 VEEGs, these we included the ones with duration over 24 continuous hours and excluded those with incomplete data, with exclusively nonepileptic events, those with intracranial electrodes and VEEG with more than 10 epileptic seizures. They were classified the DSET according to localization into five groups (frontal- ANT, temporal - TEMP, posterior quadrant - POST, undetermined definida - UD e generalized - GEN). We included 655 VEEGs, 57% of them of male patients. Mean duration of VEEG recordings was 56.7± 46.5 hr for GEN and 99.9±16.4 for localized onset; with a mean duration of 102.5 ± 62.5 hr for temporal onset (524 VEEGs). Antiepileptic drugs were tampered down in 50.6% of TEMP, in 48.6% of ANT, 33.3% of POST and in 50% of GEN. Complications were more frequent in the GEN group with 5,2% unrecorded seizures and the POST group 0.9% of seizures with prolonged seizures or status. Mean duration of VEEG recording until the first ideal seizures was 56.6 (± 52.1) hr for ANT; 53.2 (± 48.5) hr for TEMP; 39.7 (±32.4) for POST. The zone of ictal onset was adequately localized in 67.7% of TEMP, in 63% of POST, in 40% of ANT. For the group of localized epilepsies,70.1 % of seizures occurred during arousal, 24.4 % of seizures occurred in the morning; 33.7 % in the afternoom and 41.9 % at nigth. The minimum recording time of VEEG for determining the zone of ictal onset should range from 53 hr (1st ideal seizures) to 79 hr (last recorded seizures). VEEGs recordings should include all night and day, as much as 42% of all seizures occurred only during night time. These data will be useful in planning evaluations for diagnosis and surgical treatment of epilepsy Key Words: Epilepsy, Video-eletrencephalograma, Video-EEG, Ictal Onset Zone, Surgical Treatment of Epilepsy, Diagnosis of Epilepsy.
167

Metodologia para determinação do índice de colheitabilidade para avaliar a colheita mecanizada de cana-de-açúcar / Methodology to set the harvestability index to evaluate the mechanized harvest of sugar cane

Ramos, Carlos Renato Guedes [UNESP] 20 July 2016 (has links)
Submitted by CARLOS RENATO GUEDES RAMOS null (carlosguedes.al@hotmail.com) on 2016-10-25T14:36:04Z No. of bitstreams: 1 METODOLOGIA PARA DETERMINAÇÃO DO ÍNDICE DE COLHEITABILIDADE PARA AVALIAR A COLHEITA MECANIZADA DE CANA-DE-AÇÚCAR (2).pdf: 5874875 bytes, checksum: 6432f3f5c2216c27ad9fcf0b543b7637 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-26T17:20:31Z (GMT) No. of bitstreams: 1 ramos_crg_dr_bot.pdf: 5874875 bytes, checksum: 6432f3f5c2216c27ad9fcf0b543b7637 (MD5) / Made available in DSpace on 2016-10-26T17:20:31Z (GMT). No. of bitstreams: 1 ramos_crg_dr_bot.pdf: 5874875 bytes, checksum: 6432f3f5c2216c27ad9fcf0b543b7637 (MD5) Previous issue date: 2016-07-20 / A expansão das lavouras de cana-de-açúcar no Brasil favorece a utilização do sistema de colheita mecanizada, contudo as diferenças de relevo, solo e clima das regiões produtoras impactam na tomada de decisão quanto às características das colhedoras que serão utilizadas, a fim de promover o rendimento operacional e econômico, com melhor qualidade da matéria-prima colhida. Este trabalho teve como objetivo elaborar e avaliar uma metodologia para verificar do estado do canavial em pré colheita, considerando-se as condições culturais, de solo, plantio e sistematização, utilizando uma ferramenta de análise qualitativa para determinação do índice de colheitabilidade em diferentes canaviais e a partir deste, avaliar o desempenho operacional e a qualidade da colheita de colhedoras de cana-de-açúcar, visando a adequação da operação de colheita. Foram realizados dois ensaios, com delineamento em faixas, onde cada tratamento foi aplicado em uma faixa e representou a colheita de uma parcela experimental. O ensaio 1 foi realizado utilizando-se duas colhedoras (A e B), três rotações do extrator primário (Baixa, Intermediária e Alta), duas áreas com produtividade agrícola distintas (Baixa e Alta) e duas velocidades de trabalho (Padrão de 4,0 km h-1 e máxima alcançada), constituindo-se 24 tratamentos ou parcelas experimentais. O ensaio 2 foi realizado utilizando-se duas colhedoras (C e D), três rotações do extrator primário (Baixa, Intermediária e Alta), duas áreas com produtividade agrícola distintas (Baixa e Alta) e duas velocidades de trabalho (Padrão de 5,0 km h-1 e máxima alcançada), constituindo-se 24 tratamentos ou parcelas experimentais. Observou-se que os fatores porte do canavial, produtividade agrícola, sistematização/nivelamento, declividade do terreno, alinhamento entre fileiras e posição das soqueiras, respectivamente, tiveram influência nos resultados que compuseram o índice de colheitabilidade dos canaviais estudados. A produtividade agrícola do canavial apresentou influência nos resultados de desempenho operacional e qualidade da colheita. Em canaviais com pior índice colheitabilidade foram encontrados piores resultados de altura de toco e abalo de soqueira. As perdas de matéria-prima variaram em função da velocidade de colheita e da produtividade agrícola, sendo maiores quando aumentou-se tanto a velocidade quanto a produtividade agrícola.
168

Método para identificar simultaneamente duas características elétricas moduláveis por parâmetros fisiológicos de microcircuitos RLC injetáveis

Oliveira, Raul José Fernandes de 10 2011 (has links)
Este trabalho propõe um método biotelemétrico para a determinação simultânea de duas características elétricas (moduláveis por parâmetros fisiológicos) de circuitos RLC passivos para microsensores injetáveis. Como o ambiente sob monitoração envolve a presença de íons (tecidos biológicos), a utilização de dipolos torna-se inviável, desta forma, o estabelecimento de um acoplamento indutivo entre o sensor e o dispositivo para o registro das medidas é necessário. Tratando-se de um dispositivo injetável, as dimensões da bobina do sensor são diminutas (diâmetro da ordem de mm), sugerindo cuidados especiais quanto ao acoplamento indutivo do circuito RLC com o dispositivo de registro das medidas. Desta forma, foi desenvolvido um detector digital de freqüências, associado a um conjunto otimizado de bobinas para obter, a determinada distância (5 mm), a melhor indutância mútua possível com o microcircuito RLC remoto. Este dispositivo monitora o sensor em tempo real, informando a freqüência de ressonância, a sua respectiva amplitude a partir de uma varredura em freqüência. Um estudo analítico modelando a resposta em tensão do circuito detector segundo os estímulos e respostas que este fornece e recebe do circuito RLC remoto foi desenvolvido. O resultado desta análise, verificada praticamente, possibilitou a identificação da constante de tempo que cada degrau de freqüência deve ser mantido no sensor para que a resposta indicada seja a mais precisa possível. Decorrente desta análise foi possível modelar teoricamente a resistência total que o circuito RLC remoto apresenta. Assim, a partir das medidas de freqüência e amplitude do detector e do modelo teórico da resistência total do sensor o método foi estabelecido. Para verificar na prática a validade do método um micro sensor (2,8 x 23 mm) foi desenvolvido. O sensor foi encapsulado dentro de um tubo de silicone, apresentando um indutor montado junto a um bastão de ferrite, um capacitor SMD e um NTC, todos associados em paralelo. Com a alteração da distância entre o bastão de ferrite e o indutor (através da tração do tubo de silicone) a freqüência do sensor é alterada e a variação da resistência do NTC, através da temperatura, altera o fator de qualidade do sensor. A utilização do método para monitorar o sensor apresentou erros inferiores a 0,57 % para a indicação da freqüência e 0,77 % para a indicação da temperatura. A influência medida da variação da temperatura sobre a indicação da freqüência foi inferior a 0,16 %, indicando que o método é viável. / This work proposes a biotelemetric method to determine simultaneously two electrical characteristics (modulated by physiological parameters) from a passive injectable RLC microcircuit. Due to the presence of free ions inside the biological tissue, inductive links (loop antennas) must be employed, instead of dipole antennas. As the coil of the sensor presents small dimensions (diameter of about mm) its magnetic coupling to the monitoring device requires special attention. To monitor the sensor, a digital device assembled with a group of coils to maximize the mutual inductance (at a distance of 5 mm) between them was developed, detecting its resonance frequencies and the respective amplitude (through a frequency sweep) in real-time. The electrical response acquired by the detector from the sensor was analytically modeled. The model indicates a time constant to consider for each change of the signal frequencies to prevent errors in the response. From that theoretical model, an equation to determine the total resistance from the RLC circuit was obtained and confirmed by experiments. Then, a method to determine the resonance frequency and the total resistance from remote RLC circuit was proposed. A sensor was developed to verify the accuracy and the limits from this method. A parallel RLC circuit was built inside a silicone rubber tube. When the tube is stretched, a ferrite rod assembled beside the inductor is displaced varying the resonance frequency and, changing the environmental temperature, a NTC varies the quality factor of the circuit. Tests using the proposed method to monitor the sensor were realized. Errors small than 0.57 % in the resonance frequencies and 0.77 % in the temperature were obtained. The measured influence of the temperature variation over frequency determination was less than 0.16 %, indicating that the method is feasible.
169

Desenvolvimento de uma câmara de pressão positiva para estudos em fisiologia espacial

Disiuta, Leandro January 2014 (has links)
Made available in DSpace on 2014-08-16T02:01:15Z (GMT). No. of bitstreams: 1 000460260-Texto+Completo-0.pdf: 4336940 bytes, checksum: dca359fe8c5ae44e193444e9c8fcfd08 (MD5) Previous issue date: 2014 / Missions to Mars and return astronauts to the Moon may be true in the near future, which will expose them upon hypogravity environments. Some techniques are applied to simulate gravitational force reduced to prepare the crew to better adapt to those environments. This study aimed to develop a prototype of a lower body positive pressure (LBPP), as an alternative to the simulations currently used. This device is able to unload a volunteer on a physical exercise device, creating a hypogravity environment, simulating the human gait, for studies in space physiology. For development of the LBPP was necessary planning since its conception until the final prototype with functionality testing. A control system has been implemented for closed-loop pressure control. Equipment were identified and adapted such as blower, frequency inverter to control the blower, sensors (pressure, temperature and humidity), load cells to measure apparent weight of volunteer, microcontroller, treadmill for gait simulation and Neoprene short for connection of volunteer to a Neoprene membrane. Equipment and instrumentation were also developed to integrate and facilitate the system. Was developed the main chamber of a flexible PVC material, a metallic structure for height adjustment. Also was developed the instrumentation of load cells, as well as instrumentations of the sensors to adapt and read by the microcontroller. Furthermore it was necessary to develop software for data acquisition, the instrumentation of the blower and the frequency inverter to digital control by the microcontroller and an emergency circuit to ensure safety operation of the equipment. Experimental results shown that the LBPP is able to reduce the apparent weight of a load with similar weight values on Mars and the Moon, reaching the goal, where it was possible to verify that the pressure ratio and apparent weight is inversely proportional, which confirmed the theory. / Missões tripuladas para Marte e o retorno a Lua poderão concretizar-se em um futuro próximo, onde irão expor os astronautas a ambientes de hipogravidade. Técnicas de redução da força gravitacional são aplicadas como medidas para preparação da tripulação a uma melhor adaptação a tais ambientes. O presente trabalho objetivou desenvolver um protótipo funcional de uma câmara de pressão positiva (CPP), sendo uma alternativa às simulações utilizadas atualmente. Tal dispositivo é capaz de diminuir o peso aparente do voluntário sobre um sistema de exercícios físicos, gerando um ambiente de hipogravidade para estudos em fisiologia espacial. Para o desenvolvimento da CPP foi necessário um planejamento desde sua idealização até o protótipo final com testes de funcionalidade. Primeiramente foi idealizado um sistema de controle em malha-fechada para o controle da pressão. Para isso foram identificados e adaptados diversos equipamentos como soprador, inversor de frequência para o controle do soprador, sensores de pressão, temperatura e umidade, células de carga para mensurar o peso aparente do voluntário, microcontrolador, esteira ergométrica para simulação da marcha em hipogravidade e um short para conectar o voluntário à membrana de Neoprene. Equipamentos e instrumentação também foram desenvolvidos para integrar e viabilizar o sistema. Foi desenvolvida uma câmara composta de material flexível de PVC, uma estrutura metálica para ajuste de altura e também instrumentação das células de carga e dos sensor de pressão, temperatura e umidade para adaptação e leitura pelo microcontrolador. Além disso foi necessária o desenvolvimento de um software para aquisição de dados a instrumentação do soprador e do inversor de frequência para o controle digital do microcontrolador e um circuito de emergência para garantir a segurança do voluntário. Resultados experimentais mostram que a CPP é capaz de diminuir o peso aparente de uma carga com valores semelhantes ao peso em Marte e Lua, atingindo seu objetivo, onde foi possível verificar que a relação de pressão e peso aparente é inversamente proporcional, confirmando a teoria.
170

Método para identificar simultaneamente duas características elétricas moduláveis por parâmetros fisiológicos de microcircuitos RLC injetáveis

Oliveira, Raul José Fernandes de 10 2011 (has links)
Este trabalho propõe um método biotelemétrico para a determinação simultânea de duas características elétricas (moduláveis por parâmetros fisiológicos) de circuitos RLC passivos para microsensores injetáveis. Como o ambiente sob monitoração envolve a presença de íons (tecidos biológicos), a utilização de dipolos torna-se inviável, desta forma, o estabelecimento de um acoplamento indutivo entre o sensor e o dispositivo para o registro das medidas é necessário. Tratando-se de um dispositivo injetável, as dimensões da bobina do sensor são diminutas (diâmetro da ordem de mm), sugerindo cuidados especiais quanto ao acoplamento indutivo do circuito RLC com o dispositivo de registro das medidas. Desta forma, foi desenvolvido um detector digital de freqüências, associado a um conjunto otimizado de bobinas para obter, a determinada distância (5 mm), a melhor indutância mútua possível com o microcircuito RLC remoto. Este dispositivo monitora o sensor em tempo real, informando a freqüência de ressonância, a sua respectiva amplitude a partir de uma varredura em freqüência. Um estudo analítico modelando a resposta em tensão do circuito detector segundo os estímulos e respostas que este fornece e recebe do circuito RLC remoto foi desenvolvido. O resultado desta análise, verificada praticamente, possibilitou a identificação da constante de tempo que cada degrau de freqüência deve ser mantido no sensor para que a resposta indicada seja a mais precisa possível. Decorrente desta análise foi possível modelar teoricamente a resistência total que o circuito RLC remoto apresenta. Assim, a partir das medidas de freqüência e amplitude do detector e do modelo teórico da resistência total do sensor o método foi estabelecido. Para verificar na prática a validade do método um micro sensor (2,8 x 23 mm) foi desenvolvido. O sensor foi encapsulado dentro de um tubo de silicone, apresentando um indutor montado junto a um bastão de ferrite, um capacitor SMD e um NTC, todos associados em paralelo. Com a alteração da distância entre o bastão de ferrite e o indutor (através da tração do tubo de silicone) a freqüência do sensor é alterada e a variação da resistência do NTC, através da temperatura, altera o fator de qualidade do sensor. A utilização do método para monitorar o sensor apresentou erros inferiores a 0,57 % para a indicação da freqüência e 0,77 % para a indicação da temperatura. A influência medida da variação da temperatura sobre a indicação da freqüência foi inferior a 0,16 %, indicando que o método é viável. / This work proposes a biotelemetric method to determine simultaneously two electrical characteristics (modulated by physiological parameters) from a passive injectable RLC microcircuit. Due to the presence of free ions inside the biological tissue, inductive links (loop antennas) must be employed, instead of dipole antennas. As the coil of the sensor presents small dimensions (diameter of about mm) its magnetic coupling to the monitoring device requires special attention. To monitor the sensor, a digital device assembled with a group of coils to maximize the mutual inductance (at a distance of 5 mm) between them was developed, detecting its resonance frequencies and the respective amplitude (through a frequency sweep) in real-time. The electrical response acquired by the detector from the sensor was analytically modeled. The model indicates a time constant to consider for each change of the signal frequencies to prevent errors in the response. From that theoretical model, an equation to determine the total resistance from the RLC circuit was obtained and confirmed by experiments. Then, a method to determine the resonance frequency and the total resistance from remote RLC circuit was proposed. A sensor was developed to verify the accuracy and the limits from this method. A parallel RLC circuit was built inside a silicone rubber tube. When the tube is stretched, a ferrite rod assembled beside the inductor is displaced varying the resonance frequency and, changing the environmental temperature, a NTC varies the quality factor of the circuit. Tests using the proposed method to monitor the sensor were realized. Errors small than 0.57 % in the resonance frequencies and 0.77 % in the temperature were obtained. The measured influence of the temperature variation over frequency determination was less than 0.16 %, indicating that the method is feasible.

Page generated in 0.1909 seconds