171

Condition monitoring of transformer’s bushings using computational intelligence

Maumela, Joshua Tshifhiwa 16 April 2014 (has links)
M.Ing. (Electrical and Electronic Engineering) / Dissolved Gas-in-oil analysis (DGA) is used to monitor the condition of bushings on large power transformers. There are different techniques used in determining the conditions from the data collected, but in this work the Artificial Intelligence techniques are investigated. This work investigates which gases in DGA are related to each other and which ones are important for making decisions. When the related and crucial gases are determined, the other gases are discarded thereby reducing the number of attributes in DGA. Hence a further investigation is done to see how these new datasets influence the performance of the classifiers used to classify the DGA of full attributes. The classifiers used in these experiments were Backpropagation Neural Networks (BPNN) and Support Vector Machines (SVM) whereas the Principal Component Analysis (PCA), Rough Set (RS), Incremental Granular Ranking (GR++) and Decision Trees (DT) were used to reduce the attributes of the dataset. The parameters used when training the BPNN and SVM classifiers are kept fixed to create a controlled test environment when investigating the effects of reducing the number of gases. This work further introduced a new classifier that can handle high dimension dataset and noisy dataset, Rough Neural Network (RNN). This classifier was tested when trained using the full dataset and how it is affected by reducing the number of gases used to train it. The results in these experiments showed that ethane and total combustible gases attributes are core attributes chosen by the four algorithms as gases needed for decision making. The average results of the classification performance showed that the reduction of attributes helps improve the performance of classifiers. Hence the science of transformer condition monitoring can be derived from studying the relations and patterns created by the different gases attributes in DGA. This statement is supported by the classification improvements where the RNN classifier had 99.7% classification accuracy when trained using the three attributes determined by the PCA.
172

Phase Characterization Of Partial Discharge Distributions In An Oil-Pressboard Insulation System

Raja, K 10 1900 (has links) (PDF)
No description available.
173

Investigations On The Breakdown Of Paper-oil Insulation System Under AC, DC And Combined Voltages

Viswanatha, C 07 1900 (has links) (PDF)
No description available.
174

Investigations Into Internal Partial Discharge Ageing And Breakdown Of Thin Polypropylene Films

Thomas, Benny 09 1900 (has links) (PDF)
No description available.
175

Improved condition monitoring of composite insulators

Da Silva domingues, Elizabeth January 2012 (has links)
Although the cost of investment in power lines insulators is 3-5% of the total cost of the installation, the impact of their performance on reliability, failure costs, maintenance routines, etc in power systems is tens of times higher. Composite insulators were introduced 50 years ago and have been used around the world with consistently good experience. Low weight, easy handling, good performance under high pollution, low maintenance costs, and resistance to vandalism are some of their advantages. Nevertheless, acid rain, salty dust deposition, corona discharges, ozone, UV radiation, and humidity among other factors, deteriorate the quality of the polymeric housing reducing their hydrophobicity. The synergistic action of ageing factors is extremely complex and the whole degradation process may change when any one variable is slightly modified. Many studies have been carried out to increase understanding of the physicochemical processes which control the electrical and mechanical stability of polymers during in-service ageing with the objective of predicting remaining life-times. Vital areas of knowledge about polymer insulators are still incomplete and lacking; three of them are: (1) early stages of degradation in service under different environmental conditions, (2) monitoring and diagnosis techniques suitable for distribution installations and (3) steps to establish an insulators management plan based on condition and risk of failure. In this research these three topics are covered. A full review of literature about management of electrical distribution assets is included, followed by a specific plan developed for monitoring, diagnosis and ranking of insulators mainly supported by visual inspections. Diagnosis of medium voltages EPDM insulators recovered from service aged under different conditions is done using both traditional techniques and, uniquely, dielectric impedance. The relationship between surface roughness and static contact angle is also used to characterize insulators' surfaces. Early stages of degradation are studied focusing the experimental work to evaluate the electrohydrodynamic processes which occur on new samples under different conditions, giving special attention to leakage current pulse analysis, electric field enhancement, and resistance/capacitive behaviour including phase of leakage current. Results from each specific topic offer additional understanding of polymer insulators degradation providing insight to monitoring, diagnosis and management. Additionally, results open new topics in which new investigations are proposed.
176

Untersuchungen zu Gasphasentransporten in quasibinären Systemen von Bi2Se3 mit Bi2Te3, Sb2Se3, MnSe und FeSe zur Erzeugung von Nanokristallen

Nowka, Christian 16 January 2017 (has links) (PDF)
In Topologischen Isolatoren (TI) werden metallische Zustände an der Oberfläche beobachtet, während die entsprechenden Volumenzustände eine Bandlücke aufweisen. Der Volumenbeitrag zur Leitfähigkeit von TI-Materialien macht eine Synthese von Nanokristallen bzw. eine Dotierung nötig. Der Fokus der Untersuchungen dieser Arbeit liegt dabei auf der Erzeugung von Nanokristallen der TI-Materialien Bi2Te3- und Bi2Te2Se sowie dotierter Bi2Se3-Nanokristallen. Die Synthese der Nanokristalle erfolgte durch den Gasphasentransport im geschlossenen System über den Mechanismus einer Zersetzungssublimation bzw. unter dem Einsatz eines Transportmittels. Für eine erfolgreiche Erzeugung der Nanokristalle sind im Vorfeld thermodynamische Modellierungen des Gasphasentransports sowie Versuche zum chemischen Transport für die quasibinären Systeme Bi2Se3-Bi2Te3, Bi2Se3-Sb2Se3 und Bi2Se3-FeSe sowie für das ternäre System Mn-Bi-Se durchgeführt worden. Durch Versuche zum chemischen Transport konnten die Aussagen der Modellierung bestätigt und im Weiteren der Dotandengehalt in den abgeschiedenen Kristallen sowie der Einlagerungsmechanismus durch Ergebnisse aus XRD- und ICP-OES-Untersuchungen beschrieben werden. Die Synthese bzw. Dotierung der Nanokristalle wurde hauptsächlich durch die Transportrate und den Dampfdruck des Dotanden bestimmt. In den Systemen Bi2Se3-Bi2Te3 und Bi2Se3-Sb2Se3 ist ein Gasphasentransport über eine Zersetzungssublimation durchführbar und resultierte in einer erfolgreichen Darstellung von Bi2Te3- und Bi2Te2Se-Nanokristallen sowie von dotierten (SbxBi1-x)2Se3-Nanokristallen. Entgegen dessen erfolgte der Gasphasentransport in den Systemen Bi2Se3-FeSe und Mn-Bi-Se unter Verwendung eines Transportmittels. Hierbei verringerten die gesteigerten Transportraten das Wachtum von Nanokristallen. Im Weiteren gelang es dotierte (Fe,Mn)xBi2-xSe3-Volumenkristalle sowie MnBi2Se4-Einkristalle darzustellen und mittels XRD, ICP-OES, magnetischer Messungen sowie elektrischem Transport zu charakterisieren.
177

Modelo de elementos finitos aplicado na avaliação de desempenho de isolantes em ambientes contaminados

LOPES, Diego Soares 19 July 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-07-11T12:20:54Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Diego_Lopes_Dissertacao.pdf: 4018850 bytes, checksum: a5aa0e7bd17e5fbdc23ed085f38eca0c (MD5) / Made available in DSpace on 2017-07-11T12:20:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Diego_Lopes_Dissertacao.pdf: 4018850 bytes, checksum: a5aa0e7bd17e5fbdc23ed085f38eca0c (MD5) Previous issue date: 2016-07-19 / CAPES / A presente dissertação aplica um modelo computacional para mapeamento da distribuição de potencial e campo elétrico ao longo de dispositivos isolantes na presença de uma camada condutiva em sua superfície. Na natureza, a formação dessa camada se dá através da deposição de poluição juntamente com a umidade ambiental. A pesquisa teve como base outros estudos presentes na literatura que abordam a mesma temática. A avaliação do comportamento da distribuição de potencial e campo elétrico em peças isolantes é de fundamental importância na determinação de possíveis regiões, as quais esses dispositivos apresentem maior estresse elétrico, tais regiões podem levar a descargas parciais e possíveis desgastes dos acessórios levando assim à sua falha. O modelo aplicado foi implementado utilizando o MEF (Método dos Elementos Finitos) através da construção do ambiente nosoftwareCOMSOLMultiphysicse da representação gráfica do acessório noAutoCAD. O estudo foi realizado em isoladores de vidro e polimérico, bem como em espaçadores, sob diferentes níveis de poluição. Os resultados obtidos são coerentes e apresentam consonância com a teoria envolvida neste estudo. / This dissertation applies a computational model to map the voltage distribution and electric field along dielectric devices in presence of a thin conductive layer on its surface. In the nature this thin layer may appear due to pollution deposition with environmental humidity. The base of this research are another studies found in literature with the same theme. The behavior of voltage distribution and electric field in dielectric devices has significant importance helping to determine possible regions where this devices present higher stress levels, causing partial discharges and possible damage to the accessories leading them to a failure condition. The applied model was implemented using FEM (finite element method) building an environment in COMSOL Multiphysics software and graphically representing each accessory through using AutoCAD. The present study was done in insulators made of glass and polymer, as well as spacers, under several pollution levels. The obtained results are consistent and show consonance with the whole theory involved in this research.
178

Triboeletrização : evidências da participação de reações mecanoquimicas / Triboelectrification : evidences for the participation of mechanochemical reactions

Balestrin, Lia Beraldo da Silveira, 1991- 02 December 2015 (has links)
Orientador: Fernando Galembeck / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-27T09:01:49Z (GMT). No. of bitstreams: 1 Balestrin_LiaBeraldodaSilveira_M.pdf: 4255591 bytes, checksum: c4d0f9d5952dc35354bfb9f0d111643b (MD5) Previous issue date: 2015 / Resumo: Quando dois materiais isolantes são atritados, ocorre a triboeletrização de suas superfícies, isto é, a formação de cargas estáticas, distribuídas em padrões fractais. Uma das hipóteses para explicar a eletrização de isolantes é a ocorrência de reações mecanoquímicas seguidas da transferência mútua de massa. Esta dissertação apresenta mapas de potencial elétrico de superfícies atritadas, que também foram examinadas por microscopia eletrônica de varredura (SEI, BEI) e microanálise EDX. Os resultados verificam a hipótese mecanoquímica associada à transferência de fragmentos poliméricos iônicos, sendo as reações iniciadas pela quebra de cadeias seguida da formação de várias espécies de alta energia e produtos de oxidação. Microanálises também detectaram a fixação de N2 nestas superfícies, evidenciando a participação da atmosfera e a formação de triboplasma. As imagens BEI revelam uma distribuição fractal de composição química consistente com a distribuição de fragmentos limitada por difusão, mas superior à dimensão fractal de distribuição de cargas. Esta diferença é atribuída à supressão de cargas devido a microdescargas elétricas desencadeadas por gradientes superiores à rigidez dielétrica do sólido ou do ar. As microdescargas diminuem os gradientes elétricos, mas, ao mesmo tempo, geram novas espécies muito reativas, aumentando a heterogeneidade química das superfícies. Essa dissertação descreve também alguns experimentos acerca da eletrização produzida por simples contato, obtendo-se padrões bem definidos com tempo de contato de 1 h, porém não revelam a transferência de fragmentos poliméricos mutuamente, sugerindo que o cisalhamento desempenhe um papel importante na transferência de fragmentos poliméricos eletrizados. Em um menor grau de aprofundamento, esta dissertação contempla outras consequências de cargas estáticas, como alterações no coeficiente de atrito / Abstract: Triboelectrification occurs when two insulators are rubbed, i.e. static charges are formed on the surface with a fractal distribution pattern. One of the hypotheses raised by the literature indicates that the electrification is accompanied by mutual mass transfer. This dissertation presents electric potential maps of rubbed surfaces, which were also examined by scanning electron microscopy (SEI, BEI) and EDX microanalysis. The results verify the hypothesis that the electrification is due to mechanochemical reactions associated with transfer of charged polymeric fragments. The reaction is initiated by breaking the chains, generating reactive species and oxidation products. Microanalysis also detected N2 fixation on these surfaces, evidencing the contribution of the atmosphere and the formation of triboplasma. The BEI images show a fractal distribution of chemical composition consistent with a fragment distribution limited by diffusion, but higher than the fractal dimension of the charge distribution. This difference is attributed to the suppression of charges due to electrical micro discharge triggered by gradients higher than the dielectric strength of solid or air. The micro discharges decrease electrical gradients, but at the same time, generates very reactive species further increasing the chemical heterogeneity of surfaces. This dissertation also describes some experiments about the electrification produced by single contact, resulting in well-defined patterns with a contact time of 1 h, but do not show the mutual transfer of polymeric fragments, suggesting that the shearing plays an important role in transferring electrified fragments. This work also includes other consequences of static charges, such as changes in the friction coefficient / Mestrado / Físico-Química / Mestra em Química
179

Vliv aditiv na elektrické vlastnosti epoxidových pryskyřic / Additives effect on electrical properties of the epoxy resins

Šebesta, Petr January 2016 (has links)
Work was carried out in collaboration with SYNPO, Inc. Pardubice, which provided samples resins with various additives for measurement. The work is divided into three theoretical and one practical chapters. The first chapter focuses on dielectrics in general. It deals with their properties and storyline running in them. The second chapter discusses epoxy resins, their formulation, production and application in manufacturing. The third chapter offers a view of the measurement methods used for diagnosing electrical dielectrics. The practical part describes the preparation of samples and their composition, and consequently their measurement with the evaluation of measurement data.
180

Das mechanische Verhalten von Verbundisolatoren für die elektrische Energietechnik

Papailiou, Konstantin 13 August 2020 (has links)
Diese Arbeit ist das Ergebnis von mehr als 35 Jahren Erfahrung mit Hochspannungsfreileitungen, 25 Jahre davon sind durch die intensive Beschäftigung mit Silikonverbundisolatoren stark geprägt worden. Verbundisolatoren werden inzwischen als gleichwertige Alternative zu Porzellan- und Glasisolatoren anerkannt und weltweit in großen Stückzahlen eingesetzt. Durch die Verschiedenartigkeit seiner Komponenten ist die Wechselwirkung zwischen mechanischer und elektrischer Integrität bei einem Verbundisolator von großer Bedeutung. Man denke z.B. an die Auswirkung von Rissen im glasfaserverstärkten Kern, die durch unzureichende mechanische Auslegung entstehen und Teilentladungen bzw. im schlimmsten Fall einen inneren Durchschlag verursachen können. In diesem Sinne untersucht diese Arbeit , nach einer kurzen Einleitung, die verschiedenen Bauarten von Verbundisolatoren, d.h. Verbundlangstäbe, Verbundstützer, Isoliertraversen für Kompaktleitungen und Phasenabstandshalter; insbesondere für letztere werden neue Erkenntnisse zu deren mechanischen Bemessung hier erstmalig veröffentlicht.:1 Einleitung 1.1 Vorteile und Entwicklung von Verbundisolatoren 1.2 Erfahrungen mit Verbundisolatoren 1.3 Einsatz von Verbundisolatoren in Hochspannungsfreileitungen 1.4 Einsatz von Verbundisolatoren bei elektrischen Apparaten und Freiluftschaltanlagen. 1.5 Stand der Normung 2 Verbundlangstabisolatoren 2.1 Anwendungen von Verbundlangstabisolatoren 2.2 Das Verhalten von Verbundlangstabisolatoren unter mechanischer Beanspruchung 2.2.1 Die Dauerstandfestigkeit von Verbundlangstabisolatoren 2.2.1.1 Die Dauerkraftkurve von Verbundisolatoren nach IEC 61109/92 2.2.1.2 Mechanisches Modell für das Langzeitverhalten von Verbundisolatoren 2.3 Verhalten von Verbundlangstabisolatoren bei dynamischer Belastung 2.4 Auslegung und Montage von Endarmaturen für Verbundlangstäbe 2.4.1 Entwicklung und Stand der Technik der Metallarmaturen 2.4.2 Grundsätzliche Überlegungen zu der Auslegung von Pressarmaturen 2.4.3 Montagetechnik von Pressarmaturen 2.4.4 Berechnungssystematik 2.4.5 Einfache analytische Methode 2.4.6 Fortgeschrittene analytische Methode 2.4.6.1 Verpressung 2.4.6.2 Relaxation 2.4.6.3 Zugbelastung/Pull-out 2.4.7 Numerische Simulation 2.4.7.1 Finite Elemente Modell 2.4.7.2 Rechenergebnisse der Simulation 2.4.7.3 Ergebnisse der numerischen Versagenssimulation 2.4.7.4 Versuchsergebnisse 2.4.7.5 Sensitivitätsanalyse 2.5 Formelzeichen und Abkürzungen 3 Verbundstützisolatoren 3.1 Wesentliche Eigenschaften 3.2 Anwendungen von Verbundstützisolatoren 3.3 Das Verhalten von Verbundstützisolatoren unter Biegung 3.3.1 Allgemeines 3.3.2 Einführung einer Schadensgrenze (damage limit) 3.3.2.1 Versuche zur Bestimmung der Schadensgrenze 3.3.2.2 Versuch zur Bestimmung der maximalen Betriebsbiegelast (MDCL) 3.3.2.3 Bestimmung der MDCL und der SCL im gleichen Versuch 3.4 Herstellerangaben zum SCL/MDCL Konzept 3.5 Das sichere Verhalten beim Versagen von Verbundstützern (safe failure mode) 3.6 Kombinierte Belastungen 3.6.1 Lastdiagramme 3.6.2 Beispiele 3.6.2.1 Horizontale Lage des Isolators 3.6.2.2 Isolator bildet einen Winkel von β = 15° zur Horizontalen 3.6.3 Computersimulation 3.6.4 Versuche 3.7 Dynamische Belastungen 3.7.1 Prüflinge 3.7.2 Prüfverfahren 3.7.3 Versuchsergebnisse 3.8 Konstruktive Anforderungen der Endarmaturen 3.9 Analytische Berechnungsmethoden 3.9.1 Einfache analytische Methode 3.9.2 Fortgeschrittene analytische Methode 3.9.2.1 Radiale Druckspannung an der Öffnung der Metallarmatur 3.9.2.2 Axialspannung im GFK-Stab innerhalb der Metallarmatur 3.9.2.3 Schubspannung in der neutralen Achse des Stabes 3.10 Numerische Simulation 3.10.1 Finite Elemente Modell 3.10.2 Versuchsanordnung 3.11 Das Versagensverhalten von Verbundstützisolatoren 3.12 Sensitivitätsanalyse 3.13 Formelzeichen und Abkürzungen 4 Isoliertraversen für Kompaktleitungen 4.1 Einleitung 4.2 Grundsätze der Kompaktierung 4.2.1 Einfluss der Seilaufhängung auf das Mastbild 4.2.2 Möglichkeiten der Leitungskompaktierung 4.2.2.1 V-Ketten 4.2.2.2 Leitungsstützer (horizontal) 4.2.2.3 Abgehängter Leitungsstützer 4.2.2.4 Isoliertraverse 4.3 Die mechanische Auslegung von Isoliertraversen 4.3.1 Die starr gelagerte Isoliertraverse 4.3.2 Die gelenkig gelagerte Isoliertraverse (horizontal-V) 4.3.3 Dynamische Belastungen 4.3.4 Stabilitätsuntersuchungen 4.4 Innovative Anwendungen von Kompaktleitungen 4.4.1 420 kV Leitung mit Hohlkörperisolatoren in der Schweiz 4.4.2 Notgestänge mit Verbundisolatoren 4.4.3 Erste 420 kV Doppelleitung mit Volkernverbundtraversen 4.5 Formelzeichen und Abkürzungen 5 Phasenabstandshalter 5.1 Einleitung 5.2 CIGRE Umfrage 5.2.1 Auswertung Fragebogen 5.2.2 Betriebserfahrungen 5.3 Anschlusstechnik 5.4 Mechanische Auslegung von Phasenabstandshaltern 5.4.1 Galloping 5.4.1.1 Galloping Amplituden 5.4.1.2 Bauweisen 5.4.1.3 Einbauempfehlungen 5.4.1.4 Belastungen der PAH durch Galloping 5.4.2 Abwurf von Eislasten 5.4.2.1 Stosskräfte auf die PAH . 5.4.3 Elektrodynamische Kurzschlusskräfte 5.4.4 Das Knickverhalten von Phasenabstandshaltern 5.5 Elektrische Auslegung von Phasenabstandshaltern 5.5.1 Mindestlänge 5.5.2 Koronaeffekte 5.5.3 Verschmutzung 5.6 Anwendungen 5.6.1 Kompaktleitung für Mittelspannung 5.6.2 Phasenabstandshalter gegen Seiltanzen durch Eisabwurf 5.6.3 Der Tennisschlägermast 5.7 Formelzeichen und Abkürzungen 6 Ausblick 7 Anhang IEC Normen betreffend Verbundisolatoren 8 Quellenverzeichnis. / This work is the result of more than 35 years of experience with high-voltage overhead lines, 25 years of which have been devoted to silicone composite insulators. Composite insulators are nowadays regarded as an equivalent alternative to porcelain and glass insulators and are used worldwide in large quantities. Due to the diverse properties of the individual insulator components, the interaction between mechanical and electrical integrity in a composite insulator is of paramount importance. For example, cracks in the glass fiber reinforced core, caused by poor mechanical design, can lead to partial discharges and in the worst case to a catastrophic internal electrical breakdown ('flashunder'). In this sense this publication examines, after a short introduction, the different types of composite insulators, i.e. composite long rods, composite posts, insulating cross-arms for compact lines and phase-to-phase spacers; for the latter a new mechanical design concept considering large deflection theory is presented here for the first time.:1 Einleitung 1.1 Vorteile und Entwicklung von Verbundisolatoren 1.2 Erfahrungen mit Verbundisolatoren 1.3 Einsatz von Verbundisolatoren in Hochspannungsfreileitungen 1.4 Einsatz von Verbundisolatoren bei elektrischen Apparaten und Freiluftschaltanlagen. 1.5 Stand der Normung 2 Verbundlangstabisolatoren 2.1 Anwendungen von Verbundlangstabisolatoren 2.2 Das Verhalten von Verbundlangstabisolatoren unter mechanischer Beanspruchung 2.2.1 Die Dauerstandfestigkeit von Verbundlangstabisolatoren 2.2.1.1 Die Dauerkraftkurve von Verbundisolatoren nach IEC 61109/92 2.2.1.2 Mechanisches Modell für das Langzeitverhalten von Verbundisolatoren 2.3 Verhalten von Verbundlangstabisolatoren bei dynamischer Belastung 2.4 Auslegung und Montage von Endarmaturen für Verbundlangstäbe 2.4.1 Entwicklung und Stand der Technik der Metallarmaturen 2.4.2 Grundsätzliche Überlegungen zu der Auslegung von Pressarmaturen 2.4.3 Montagetechnik von Pressarmaturen 2.4.4 Berechnungssystematik 2.4.5 Einfache analytische Methode 2.4.6 Fortgeschrittene analytische Methode 2.4.6.1 Verpressung 2.4.6.2 Relaxation 2.4.6.3 Zugbelastung/Pull-out 2.4.7 Numerische Simulation 2.4.7.1 Finite Elemente Modell 2.4.7.2 Rechenergebnisse der Simulation 2.4.7.3 Ergebnisse der numerischen Versagenssimulation 2.4.7.4 Versuchsergebnisse 2.4.7.5 Sensitivitätsanalyse 2.5 Formelzeichen und Abkürzungen 3 Verbundstützisolatoren 3.1 Wesentliche Eigenschaften 3.2 Anwendungen von Verbundstützisolatoren 3.3 Das Verhalten von Verbundstützisolatoren unter Biegung 3.3.1 Allgemeines 3.3.2 Einführung einer Schadensgrenze (damage limit) 3.3.2.1 Versuche zur Bestimmung der Schadensgrenze 3.3.2.2 Versuch zur Bestimmung der maximalen Betriebsbiegelast (MDCL) 3.3.2.3 Bestimmung der MDCL und der SCL im gleichen Versuch 3.4 Herstellerangaben zum SCL/MDCL Konzept 3.5 Das sichere Verhalten beim Versagen von Verbundstützern (safe failure mode) 3.6 Kombinierte Belastungen 3.6.1 Lastdiagramme 3.6.2 Beispiele 3.6.2.1 Horizontale Lage des Isolators 3.6.2.2 Isolator bildet einen Winkel von β = 15° zur Horizontalen 3.6.3 Computersimulation 3.6.4 Versuche 3.7 Dynamische Belastungen 3.7.1 Prüflinge 3.7.2 Prüfverfahren 3.7.3 Versuchsergebnisse 3.8 Konstruktive Anforderungen der Endarmaturen 3.9 Analytische Berechnungsmethoden 3.9.1 Einfache analytische Methode 3.9.2 Fortgeschrittene analytische Methode 3.9.2.1 Radiale Druckspannung an der Öffnung der Metallarmatur 3.9.2.2 Axialspannung im GFK-Stab innerhalb der Metallarmatur 3.9.2.3 Schubspannung in der neutralen Achse des Stabes 3.10 Numerische Simulation 3.10.1 Finite Elemente Modell 3.10.2 Versuchsanordnung 3.11 Das Versagensverhalten von Verbundstützisolatoren 3.12 Sensitivitätsanalyse 3.13 Formelzeichen und Abkürzungen 4 Isoliertraversen für Kompaktleitungen 4.1 Einleitung 4.2 Grundsätze der Kompaktierung 4.2.1 Einfluss der Seilaufhängung auf das Mastbild 4.2.2 Möglichkeiten der Leitungskompaktierung 4.2.2.1 V-Ketten 4.2.2.2 Leitungsstützer (horizontal) 4.2.2.3 Abgehängter Leitungsstützer 4.2.2.4 Isoliertraverse 4.3 Die mechanische Auslegung von Isoliertraversen 4.3.1 Die starr gelagerte Isoliertraverse 4.3.2 Die gelenkig gelagerte Isoliertraverse (horizontal-V) 4.3.3 Dynamische Belastungen 4.3.4 Stabilitätsuntersuchungen 4.4 Innovative Anwendungen von Kompaktleitungen 4.4.1 420 kV Leitung mit Hohlkörperisolatoren in der Schweiz 4.4.2 Notgestänge mit Verbundisolatoren 4.4.3 Erste 420 kV Doppelleitung mit Volkernverbundtraversen 4.5 Formelzeichen und Abkürzungen 5 Phasenabstandshalter 5.1 Einleitung 5.2 CIGRE Umfrage 5.2.1 Auswertung Fragebogen 5.2.2 Betriebserfahrungen 5.3 Anschlusstechnik 5.4 Mechanische Auslegung von Phasenabstandshaltern 5.4.1 Galloping 5.4.1.1 Galloping Amplituden 5.4.1.2 Bauweisen 5.4.1.3 Einbauempfehlungen 5.4.1.4 Belastungen der PAH durch Galloping 5.4.2 Abwurf von Eislasten 5.4.2.1 Stosskräfte auf die PAH . 5.4.3 Elektrodynamische Kurzschlusskräfte 5.4.4 Das Knickverhalten von Phasenabstandshaltern 5.5 Elektrische Auslegung von Phasenabstandshaltern 5.5.1 Mindestlänge 5.5.2 Koronaeffekte 5.5.3 Verschmutzung 5.6 Anwendungen 5.6.1 Kompaktleitung für Mittelspannung 5.6.2 Phasenabstandshalter gegen Seiltanzen durch Eisabwurf 5.6.3 Der Tennisschlägermast 5.7 Formelzeichen und Abkürzungen 6 Ausblick 7 Anhang IEC Normen betreffend Verbundisolatoren 8 Quellenverzeichnis.