• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 4
  • Tagged with
  • 50
  • 18
  • 14
  • 13
  • 13
  • 12
  • 12
  • 11
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e avaliação de um escudo polimérico para minimizar a quebra de isoladores de vidro por vandalismo em linhas de transmissão

de Almeida Yanaguizawa, Juliana January 2003 (has links)
Made available in DSpace on 2014-06-12T17:39:35Z (GMT). No. of bitstreams: 2 arquivo7346_1.pdf: 5102666 bytes, checksum: 05f0152b2a216043985caeed3f1993f5 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Os isoladores são utilizados para isolar os condutores da terra, fixando-os e suportando-os nas linhas de transmissão. Na atualidade, existem vários tipos de isoladores. Especificamente, os isoladores de vidro possuem uma vida útil relativamente longa, podendo chegar a 40 anos ou mais. Do ponto de vista construtivo, o vidro do isolador é temperado e tem excelentes propriedades dielétricas; possui formato de um chapéu e é fixado entre duas partes metálicas denominadas campânula e pino. Eletricamente, o isolador de vidro comporta-se como um circuito RC. Em condições a seco e sem poluição,o isolador de vidro, na sua forma íntegra, suporta uma tensão próxima de 80 kV, e não mais que 12 kV quando quebrado. No campo, o isolador está sujeito a um ambiente vulnerável a cargas de natureza eletromecânica, à ação de intempéries e danificações por vandalismo. A quebra de isoladores de vidro por vandalismo é uma realidade nacional, responsável por um número significativo de desligamentos não programados, atingindo um valor em torno de 75%. Na presente dissertação, foi conduzido um estudo para projetar e construir um mecanismo de proteção da parte vítrea do isolador e avaliar a viabilidade de utilizá-lo nas linhas de transmissão. Dentre os vários materiais dielétricos, o policarbonato foi selecionado como material para escudo protetor, baseando-se num procedimento de engenharia. A resistência mecânica do sistema de escudos foi avaliada com ensaios de impacto e balístico. Ensaios de alta-tensão foram realizados para avaliar a performance do escudo na presença de descargas na freqüência industrial (60 Hz) e impulso de manobra no laboratório de alta tensão. Ademais, foi realizado um estudo sobre a possibilidade de aumentar a proteção do escudo de policarbonato contra raios ultravioleta provenientes do sol, utilizando radiação ionizante sobre o vidro. A resistência ao impacto do escudo de policarbonato de 6 mm de espessura foi avaliada com equipamento de impacto com pêndulo. Por exemplo, a quebra do vidro do isolador protegido com o escudo foi verificada com energia de impacto próxima de 515 J enquanto que sem proteção a quebra do vidro ocorreu com aproximadamente 205 J de energia. No ensaio balístico, projéteis disparados com Magnum 44, equivalente a um rifle, somente conseguiram quebrar até 3 isoladores de vidro em cadeia quando cada isolador é protegido com o escudo. Em termos de ensaios com alta-tensão, o policarbonato praticamente não exerceu influência sobre os valores de tensão disruptiva de uma cadeia de isoladores de vidro. Em freqüência industrial, uma cadeia com 16 isoladores de vidro, possuindo apenas 7 unidades inteiras distribuídas quase uniformemente ao longo da cadeia apresentou valor de tensão disruptiva igual a 500 kV sem escudos, contra 505 kV com 10 escudos (colocados nos isoladores mais superiores da cadeia). O policarbonato apresentou boa estabilidade dimensional quando da ocorrência de arco elétrico, e não propiciou a formação de chama. Medidas espectroscópicas de ultravioleta mostraram que a camada de proteção contra a radiação UV presente nas chapas de policarbonato permite que o material absorva substancialmente os raios nocivos e aumente sua durabilidade. Por outro lado, a técnica de irradiação do vidro com raios-γ possibilitou uma melhoria substancial nos valores de absorção UV do vidro dos isoladores. O cut-off que era observado em torno de 325 nm passou para valores acima de 600 nm após airradiação com diferentes doses de raios-γ de Co-60. Ensaios adicionais sobre o fator tempo e temperatura, como tratamento térmico das amostras irradiadas feito a 70°C por sete dias, mostraram que o vidro não sofreu degradação com relação ao poder de absorção UV induzido pela irradiação com raios-γ. As propriedades do vidro, características de vidros soda-cal, estabilizaram-se após os primeiros 30 dias de irradiação. Em termos do custo de cada placa de policarbonato sugerido para o escudo, foi encontrado o valor de R$ 27,73. Por ser leve (aproximadamente 485 g), o escudo de policarbonato não prejudica o desempenho mecânico da cadeia de isoladores. O material é facilmente usinável, sendo também inofensivo ao meio ambiente e não atrai a atenção de curiosos nas linhas de transmissão pela ausência de coloração
2

Projecto de linha aérea de alta tensão com estudo do comportamento longitudinal das cadeias de isoladores

Figueiredo, Márcio Rúben de January 2009 (has links)
Estágio realizado na EDP Distribuição, Departamento de Projecto e Construção de Linhas Aéreas / Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Energia). Faculdade de Engenharia. Universidade do Porto. 2009
3

Avaliação da transmissão pela lâmina d’água do vírus da diarreia viral bovina em leitões desmamados experimentalmente infectados / Evaluation of the transmission by back pond pen of bovine viral diarrhea virus in experimentally infected weed pigs

Nascimento, Karla Alvarenga [UNESP] 09 February 2017 (has links)
Submitted by KARLA ALVARENGA NASCIMENTO null (karlanascimentovet@yahoo.com.br) on 2017-03-21T13:16:57Z No. of bitstreams: 1 Dissertação Karla.pdf: 1655729 bytes, checksum: 6cdf4bfec3aad9e315d583cdf42d5d1a (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-03-21T21:32:38Z (GMT) No. of bitstreams: 1 nascimento_ka_me_jabo.pdf: 1655729 bytes, checksum: 6cdf4bfec3aad9e315d583cdf42d5d1a (MD5) / Made available in DSpace on 2017-03-21T21:32:38Z (GMT). No. of bitstreams: 1 nascimento_ka_me_jabo.pdf: 1655729 bytes, checksum: 6cdf4bfec3aad9e315d583cdf42d5d1a (MD5) Previous issue date: 2017-02-09 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os pestivírus possuem importância significativa na suinocultura, sendo que os suínos podem ser infectados pelo Vírus da Diarreia Viral Bovina (BVDV) em condições naturais. O presente estudo teve como objetivo induzir a infecção experimental do BVDV-1 em leitões desmamados e avaliar a excreção e possível transmissão do vírus pelas vias lâmina d’água e naso-nasal. Foram conduzidos dois experimentos e uma repetição para cada via de transmissão avaliada. No total foram selecionados 24 leitões, sendo utilizados seis por experimento, divididos em grupos controle (n=2), sentinela (n=2) e infectado (n=2), utilizando isoladores, projetados para estabelecer o contato entre os animais apenas pela via de transmissão em estudo. O grupo infectado recebeu um inóculo contendo BVDV-1, estirpe Singer, enquanto que os grupos controle e sentinela foram inoculados com meio E-MEM. Os animais permaneceram nos isoladores por 25 dias, período em que foram coletadas amostras de suabe nasal diariamente e sangue a cada sete dias. Ao final, os animais foram eutanasiados e necropsiados, sendo realizada coleta de fragmentos de órgãos para histopatologia, imunohistoquímica e RT-PCR. Quando avaliada a via de transmissão lâmina d’água, apenas um animal infectado apresentou excreção de material genômico a partir do 6o dia pós-infecção (dpi), e um animal sentinela apresentou excreção no 20o dpi. Nestes animais, a soroconversão ocorreu no 25o dia apresentando título de anticorpos igual a 20. Um animal infectado não apresentou soroconversão durante o período amostrado, porém houve excreção a partir do 5o dpi. Na repetição do experimento, apenas um animal infectado soroconverteu ao 25o dia, com título de anticorpos de 20, cuja excreção do material genômico foi detectada ao 21o dpi. Nos animais sentinelas, apenas um apresentou excreção no 13o dpi. Em relação ao experimento naso-nasal, os animais infectados apresentaram excreção de material genético a partir do 17o dpi, porém a soroconversão não foi observada em todos os animais. Na repetição do experimento naso-nasal a soroconversão foi detectada em apenas um dos leitões infectados no último dia de experimento, com título de anticorpos de 20. A excreção do material genômico ocorreu nos dois animais infectados, sendo que um animal apresentou excreção a partir do dia 10 e o outro a partir do 18o dpi. Em relação à macroscopia e microscopia, os animais de todos os experimentos não apresentaram lesões significativas. O presente estudo demonstra que os suínos são susceptíveis ao BVDV, possibilitando a excreção e servir como fonte de infecção. Evidenciou-se que a lâmina d’agua pode veicular o BVDV de um suíno infectado para outro, ressaltando a importância e o risco de transmissão. A possibilidade de transmissão do BVDV pela via naso-nasal em leitões não foi provada dentro do período avaliado. / Pestiviruses have significant importance in swine breeding, and pigs can be infected by Bovine Viral Diarrhea Virus (BVDV) under natural conditions. The present study aimed to induce the experimental infection of BVDV-1 in weaned piglets and to evaluate the excretion and possible transmission of the virus through the water and naso-nasal routes. Two experiments and one replicate were conducted for each evaluated route of transmission. In total, 24 piglets were selected, and six were used per experiment, divided into control (n = 2), sentinel (n = 2) and infected (n = 2) groups using isolators, designed to establish contact between animals only by Route of study. The infected group received an inoculum containing BVDV-1, Singer strain, while the control and sentinel groups were inoculated with E-MEM medium. The animals remained in the isolators for 25 days, during which samples of nasal swab and blood were collected every seven days. At the end, the animals were euthanized and necropsied, and organ fragments were collected for histopathology, immunohistochemistry and RT-PCR. When the water-borne transmission pathway was evaluated, only one infected animal showed excretion of genomic material from day 6 post-infection (dpi), and one sentinel animal showed excretion at the 20th dpi. In these animals, seroconversion occurred on day 25 with an antibody titer equal to 20. An infected animal did not present seroconversion during the sampled period, but there was excretion from the 5th dpi. In the repeat of the experiment, only one infected animal was seroconverted at day 25, with antibody titer of 20, whose excretion of the genomic material was detected at 21o dpi. In sentinel animals, only one had excretion at the 13th dpi. In relation to the naso-nasal experiment, the infected animals presented excretion of genetic material from the 17th dpi, but seroconversion was not observed in all the animals. In the repetition of the nasonasal experiment, seroconversion was detected in only one of the infected piglets on the last day of the experiment, with an antibody titre of 20. Excretion of the genomic material occurred in the two infected animals, and one animal had excretion from the Day 10 and the other from the 18th dpi. Regarding macroscopy and microscopy, the animals of all experiments did not present significant lesions. The present study demonstrates that pigs are susceptible to BVDV, allowing excretion and serve as a source of infection. It has been shown that the water table can transport BVDV from one infected pig to another, emphasizing the importance and risk of transmission. The possibility of BVDV transmission by the nasal nasal route in piglets has not been proven within the evaluated period. / FAPESP: 2014/13590-3 / FAPESP: 2015/07098-1
4

Estudo de motores acionados por conversores de frequência e influências no sistema isolante

Karavasilis, Renato Gualda January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-23T19:07:58Z (GMT). No. of bitstreams: 1 256557.pdf: 4250360 bytes, checksum: 5915e30ad38f7acc1d13a45dfb69359c (MD5) / O presente trabalho apresenta os diversos fatores aos quais o sistema de isolação dos motores de indução são submetidos ao serem acionados por conversores de freqüência. Também são apresentadas soluções que fabricantes de motores elétricos e fornecedores de fios e materiais isolantes têm buscado com o objetivo de obter boas interações entre o motor elétrico e o conversor de freqüência. Foram realizados testes de um motor de indução de 2.500 CV, 4.160V, 04 pólos, 60Hz sendo acionado direto na rede e, também através de um inversor de freqüência. Parâmetros tais como elevação de temperatura, distorção harmônica total da corrente, fator de potência e rendimento foram registrados para ambas as condições. Os resultados obtidos mostraram para uma das fases do motor elevação de temperatura de até 9,8% superior na situação com conversor de freqüência. Para o caso com conversor de freqüência a distorção harmônica total da corrente apresentou-se 9,3% e 4,8% superior quando operando com o motor a vazio e com carga nominal respectivamente, comprovando então a condição mais severa em que o sistema de isolação do motor é submetido quando acionado por conversor de freqüência.
5

Síntese do poli(etileno-co-álcool vinílico-g-norbixina) para aplicação em isoladores elétricos de redes elétricas compacta protegida

Albach, Breidi January 2014 (has links)
Orientador : Ronilson Vasconcelos Barbosa / Co-orientador : Vitoldo Suinka Filho / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Exatas, Programa de Pós-Graduação em Química. Defesa: Curitiba, 05/08/2014 / Inclui referências : f. 64-67 / Resumo: Rede elétrica compacta protegida é a designação atual para a rede elétrica que distribui energia elétrica nas cidades. É composta por três condutores cobertos com uma camada de material polimérico e isoladores poliméricos tipo pino, bastão e os acessórios de amarração (anéis, laços e fios). Quando em operação está sujeita a estresses múltiplos, que podem levar o sistema à perda de requisitos mínimos para continuar em operação. Um dos fatores que podem acelerar o processo de deterioração dos componentes é uma atmosfera poluída, pois propicia a formação de uma camada constituída por substâncias que dissolvidas em água produzem soluções condutoras sobre a superfície isolante, desta maneira pode ocorrer o fenômeno de pré-ruptura que está associado principalmente à existência de vazios e impurezas no interior da isolação e com a ocorrência de descargas parciais quando o dielétrico está submetido a um campo elétrico. Uma maneira de detectar essas descargas parciais é a detecção através da mudança de cor de um pigmento que degrade à temperaturas elevadas. Este trabalho teve como meta o enxerto de um pigmento natural, a norbixina, em poli(etileno-co-álcool vinílico) para utilização em assessórios poliméricos de rede elétrica compacta protegida ou em qualquer outra aplicação, em que possa ser realizada colorimetricamente a identificação do aumento de temperatura em materiais poliméricos. Como resultado a síntese do polímero Eval-g-norbixina foi realizada mais não pode ser caracterizada por métodos espectroscópicos como espectroscopia no infravermelho com transformada de Fourier e ressonância magnética nuclear, pois o polímero apresentou dificuldade em solubilização. Acredita-se que isso seja devido ao fato de que haja reticulação entre as estruturas do EVAL e da norbixina. A mistura física do Eval-g-norbixina em polietileno de alta densidade (PEAD) pode ser feita onde observou-se a degradação do material por conta do processamento. Por último verificou-se que a norbixina sofre degradação no ultravioleta perdendo toda sua coloração avermelhada em 72 horas de exposição, desta maneira indica-se a utilização do pigmento em ambientes internos. Palavras-chave: rede elétrica, isoladores, dielétrico, EVAL, urucum. / Abstract: A Spacer Cable Grid is the current designation for the electrical grid which distributes electrical energy in the cities. It is composed of three conductors covered with a layer of polymeric material and polymer pin type insulators, dead-end insulators and binding accessories (ring ties and covered tie wires). When in operation is subjected to multiple stresses, that can drive the system to loss of the minimum requirements to continue operational. One of the factors that can accelerate the process of component deterioration is atmospheric pollution, which promotes the formation of a layer composed of substances that when dissolved in water result in conductive solutions on the insulating surface, thus creating the possibility of a pre-rupture phenomenon that is mainly associated with the existed of empty spaces and impurity inside the insulation with the occurrence of partial discharges when the dielectric is subjected to an electrical field. A method of detecting these partial discharges is detection through color change of a pigment that degrades at high temperatures. This work aims to insert a natural pigment, the norbixin, in poly (ethylene-co-vinyl alcohol) for use in polymer accessories of spacer cable grid as well as any other applications in which temperature increases on polymeric materials could be detected colorimetrically. As a result the synthesis of the polymer Eval-g-norbixin was produced, although it could not be characterized by spectroscopic methods such as infra-red spectroscopy with Fourier Transform and nuclear magnetic resonance, since the polymer exhibited solubility problems. It is believed that this is due to the fact that there is no bonding between the structures of the EVAL and the norbixin. The physical mixing of Eval-g-norbixin in high-density polyethylene (HDPE) could be made, in which it was observed that the degradation of the material because of the processing. Finally it was found that the norbixin suffers degradation under ultraviolet light losing its red coloration in 72 hours of exposure, therefore it is suggested the use of this pigment in indoor environments. Keywords: Electrical network, insulators, dielectric, EVAL, annatto.
6

Metodo de calculo de isolamento de torres de transmissão de energis eletrica face ao risco desejado para surto de manobra

Negrisoli, Manoel Eduardo Miranda, 1950- 07 July 1989 (has links)
Orientador: Ioshiaki Doi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T22:56:14Z (GMT). No. of bitstreams: 1 Negrisoli_ManoelEduardoMiranda_D.pdf: 7386370 bytes, checksum: e4b3aa34076d1b46932aa612fbc23701 (MD5) Previous issue date: 1989 / Resumo: O dimensionamento das distâncias elétricas de isolamento de linhas de transmissão de energia é feito em função dos níveis de isolação desejado para os vários tipos de solicitações elétricas e mecânicas a que estarão submetidas. Quanto maior a tensão de transmissão maior é a predominância relativa às solicitações de surtos de manobra.No presente trabalho é dimensionado o isolamento de uma torre de transmissão de energia elétrica em função do risco de falha total desejado, face aos surtos de manobra, considerando-se a probabilidade estatística de ocorrência de condições atmosféricas (pressão, temperatura, umidade e velocidade dos ventos), distribuição estatística dos valores dos surtos de manobra nas três fases, gaps compostos de uma torre, torres em paralelo e o balanço parcial das cadeias de isoladores de toda a linha. Inicialmente o dimensionamento das distâncias elétricas de isolamento, é feito pelas expressões convencionais de calculo para todos os tipos de solicitações elétricas. Com este projeto básico, e calculado o risco de falha, considerando-se as condições atmosféricas ambientais no trajeto da linha de transmissão. Sendo este risco de falha, maior que o previamente estipulado, realimenta-se o projeto inicial de isolamento, aumentando-se a distância onde o risco de falha for maior e assim iterativamente. o método apresentado, possibilita o dimensionamento das torres, da forma mais compacta possível ,reduzindo suas dimensões e por conseqüência seu peso e custo, em função do risco que se deseja, evitando-se isolamentos exagerados por falta de recursos de cálculo e do perfeito conhecimento das condições ambientais ao longo da linha. Para que o projeto seja completado, necessita-se ainda do posicionamento dos cabos de blindagem contra descargas elétricas atmosféricas e a avaliação do desempenho neste caso. As dimensões da torre, principalmente a cadeia de isoladores, podem ser alteradas em função deste efeito, caso não se consiga, o desempenho desejado através do posicionamento dos cabos guarda, em termos do ângulo de blindagem e acoplamento magnético com os condutores fase / Abstract: The cost of an electrical transmission line depends greatly on the cost of its towers, which in turn are priced according to their dimensions and weight. These factors are greatly influenced by the insulation and particulary by the dimensions of the air-gaps. Large air-gaps have lower risks-of-failure when submitted to a given electrical stress than srnaller ones. But there is a price to pay for the added safety in the form of higher prices.The purpose of this work is to present a method which permits an optimized design of the transmission towers insulating structures for a specified risk-of-failure, under different types of electrical stresses to which they might be submitted, considering statistica1 probabilities of unfavorable atmospheric conditions (pressure, temperature, humidity and wind speeds), amplitudes of voltage surges and its distribution along the line, as well as the number of parallel tower gaps and insulator swings. Conventional design methods are used for a preliminary design based on all .the types of overvoltage stresses and its risk of failure is calculated, considering the existing atmospheric conditions along the line route. If the calculated risk-of-failure does not comply to the.specified one, adjustments are made on the gap distances of the original design which presented highest risk and new values for the whole structure are calculated. New comparisons may indicate the netessity of new adjustments, which are made. This procedure is repeateduntil the design can be considered satisfactory andits risk-of-failure complies with the specified.one. To complete the tower insulation coordination project, a evaluation of lightining impulse performance, should be made.The tower dimensions might be changed, mainly with the aspects to insulators strings, if satisfactory performance is not achieved by the shielding cable position, with respect to the shielding angle and mutual coupling with phase cables / Doutorado / Automação / Doutor em Engenharia Elétrica
7

Aplicações das resinas poliuretanas derivadas do óleo de mamona, como materiais isolantes elétricos / not available

Murakami, Cacilda Ribeiro 14 August 2002 (has links)
Isoladores poliméricos vêm gradualmente competindo com os isoladores cerâmicos nas aplicações do sistema elétrico de potência. Embora os isoladores poliméricos ainda apresentem alguns inconvenientes, como alto custo e forte degradação no meio ambiente, principalmente diante dos raios ultravioleta, possuem outras características importantes e altamente relevantes, como por exemplo, forte resistência mecânica à compressão e à flexão, ótima resistência elétrica e facilidade de instalação e de manutenção. Por causa disso, o desenvolvimento desses novos isoladores está sendo um fator predominante na competitividade do mercado, onde se observam a constante busca de qualidade e baixo custo. No Brasil, um sério obstáculo atrapalha este avanço tecnológico devido à maioria das matérias-primas serem importadas. As resinas poliuretanas derivadas de óleo de mamona, neste contexto, apresentam um papel crucial, uma vez que elas são produzidas com 100% de tecnologia brasileira no Laboratório de Química Analítica e Tecnologia de Polímeros do Instituto de Química da Universidade de São Paulo. Portanto, neste trabalho são apresentados os processos utilizados no desenvolvimento deste novos isoladores poliméricos produzidos com resinas puras, com os seus compósitos e com granitos sintéticos. E também são apresentados os diversos ensaios realizados nas resinas e nos isoladores. Destacando-se entre eles, os ensaios de envelhecimento acelerado, os ensaios elétricos e os ensaios mecânicos realizados nos isoladores tipo Suporte, os quais resultaram em um forte indicativo para uma ótima aplicação deles em ambiente interno e com custo competitivo em relação aos isoladores comerciais. / Polymeric isolators have been competing increasingly with ceramic isolators in electric power system applications. Although polymeric isolators still present a few disadvantages, such as high cost and strong degradation in the environment (poor weathering capacity), particularly from ultraviolet rays, they possess other important and highly relevant characteristics, among them high compressive and flexural strength, excellent electric resistance and easy installation and maintenance. For these reasons, the development of these new isolators has become a predominant factor in market competitiveness, where the combination of high quality and low cost is much sought after. A major obstacle to this technological advance in Brazil is the fact that most of the raw materials are imported. Hence, castor oil polyurethane resins play a crucial role, since they are produced with 100 per cent Brazilian technology at the Laboratory of Analytical Chemistry and Polymer Technology of the Institute of Chemistry, University of Sao Paulo. This thesis, therefore, presents and discusses the processes used in the development of these new polymeric isolators produced with pure resins, with their composites, and with synthetic granites. Also discussed are the various tests carried out on the resins and on isolators, highlighting, among these, the accelerated aging, electrical and mechanical tests performed on Support type isolators, whose results are strongly indicative of their excellent applicability for indoor environments, coupled with their competitive cost in comparison to commercial isolators.
8

Aplicações das resinas poliuretanas derivadas do óleo de mamona, como materiais isolantes elétricos / not available

Cacilda Ribeiro Murakami 14 August 2002 (has links)
Isoladores poliméricos vêm gradualmente competindo com os isoladores cerâmicos nas aplicações do sistema elétrico de potência. Embora os isoladores poliméricos ainda apresentem alguns inconvenientes, como alto custo e forte degradação no meio ambiente, principalmente diante dos raios ultravioleta, possuem outras características importantes e altamente relevantes, como por exemplo, forte resistência mecânica à compressão e à flexão, ótima resistência elétrica e facilidade de instalação e de manutenção. Por causa disso, o desenvolvimento desses novos isoladores está sendo um fator predominante na competitividade do mercado, onde se observam a constante busca de qualidade e baixo custo. No Brasil, um sério obstáculo atrapalha este avanço tecnológico devido à maioria das matérias-primas serem importadas. As resinas poliuretanas derivadas de óleo de mamona, neste contexto, apresentam um papel crucial, uma vez que elas são produzidas com 100% de tecnologia brasileira no Laboratório de Química Analítica e Tecnologia de Polímeros do Instituto de Química da Universidade de São Paulo. Portanto, neste trabalho são apresentados os processos utilizados no desenvolvimento deste novos isoladores poliméricos produzidos com resinas puras, com os seus compósitos e com granitos sintéticos. E também são apresentados os diversos ensaios realizados nas resinas e nos isoladores. Destacando-se entre eles, os ensaios de envelhecimento acelerado, os ensaios elétricos e os ensaios mecânicos realizados nos isoladores tipo Suporte, os quais resultaram em um forte indicativo para uma ótima aplicação deles em ambiente interno e com custo competitivo em relação aos isoladores comerciais. / Polymeric isolators have been competing increasingly with ceramic isolators in electric power system applications. Although polymeric isolators still present a few disadvantages, such as high cost and strong degradation in the environment (poor weathering capacity), particularly from ultraviolet rays, they possess other important and highly relevant characteristics, among them high compressive and flexural strength, excellent electric resistance and easy installation and maintenance. For these reasons, the development of these new isolators has become a predominant factor in market competitiveness, where the combination of high quality and low cost is much sought after. A major obstacle to this technological advance in Brazil is the fact that most of the raw materials are imported. Hence, castor oil polyurethane resins play a crucial role, since they are produced with 100 per cent Brazilian technology at the Laboratory of Analytical Chemistry and Polymer Technology of the Institute of Chemistry, University of Sao Paulo. This thesis, therefore, presents and discusses the processes used in the development of these new polymeric isolators produced with pure resins, with their composites, and with synthetic granites. Also discussed are the various tests carried out on the resins and on isolators, highlighting, among these, the accelerated aging, electrical and mechanical tests performed on Support type isolators, whose results are strongly indicative of their excellent applicability for indoor environments, coupled with their competitive cost in comparison to commercial isolators.
9

Modelagem numérica e análise do acoplamento dinâmico estrutural por isoladores de vibração em aeronaves

Isabel Lima Hidalgo 06 December 2012 (has links)
Com o intuito de reduzir o ruído interno na cabine de aeronaves, isoladores de vibração fabricados com elastômero são montados entre a fuselagem e os painéis do interior da aeronave. Uma avaliação precisa dos caminhos de transmissão das vibrações e a correta predição dos níveis de ruído interno pode ser obtida através de modelos numéricos adequados dos isoladores e da forma com que estes acoplam a fuselagem aos painéis internos da cabine. Em geral, modelos simplificados não são capazes de prever o desempenho do isolador em frequências médias e altas, uma vez que não consideram modos naturais de vibração do próprio material do isolador. Além disto, as propriedades dinâmicas do material visco-elástico utilizado nestes isoladores não são adequadamente identificadas pelos fabricantes. Neste trabalho, testes experimentais foram realizados para se caracterizar a rigidez dinâmica do isolador. As propriedades mecânicas do elastômero foram obtidas para uma correta análise do modelo de elementos finitos, e a partir do modelo numérico atualizado, foi possível obter frequências naturais e modos de vibração e, conhecer parâmetros do real comportamento do isolador. Diferentes abordagens e complexidades para os modelos clássico de massa-mola-amortecedor e de matriz de transferência foram utilizadas para obter o comportamento dinâmico dos isoladores de vibração. Para a avaliação das diferentes formas de modelagem do isolador, considerou-se um modelo contendo um painel reforçado e um painel simples conectados por isoladores, os quais remetem a uma estrutura fuselagem-isolador-painel interior. Com este modelo foi possível comparar a resposta dinâmica e valores do fator de perda por acoplamento obtidos a partir de modelos numéricos, baseados em FEM, SEA, e híbrido SEA-FEM. Neste último, o modelo dos painéis em SEA foi combinado com o modelo em FEM do isolador. Esta combinação em modelo híbrido proporcionou obter maior fidelidade no acoplamento fuselagem-isolador-painel interno, e consequentemente levaria a predição mais acurada dos níveis de ruído dentro da cabine da aeronave.
10

Estudo e caracterização de contaminantes em isoladores de regiões rurais /

Oldoni, Claudemir Rogério, 1969-, Meyer, Luiz Henrique, 1968-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2009 (has links) (PDF)
Orientador: Luiz Henrique Meyer. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.

Page generated in 0.0558 seconds