• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 3
  • 1
  • Tagged with
  • 16
  • 16
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Electron interference within two one-dimensional ballistic channels

Simpson, Peter James January 1994 (has links)
No description available.
2

Determinação dos efeitos de vizinhança na resposta dinâmica de edifícios altos sob a ação do vento / Determination of the effects of neighbouring buildings on the dynamic response of tall buildings under wind loading

Bênia, Maria Cristina Dolz January 2013 (has links)
O processo de crescimento das cidades gerou uma necessidade pelo melhor aproveitamento do espaço urbano, contribuindo para os processos de verticalização e densificação das áreas construídas. Sendo assim, a tendência é de construção de edifícios cada vez mais altos e agrupados, duas características que influenciam na resposta das estruturas à ação do vento. Edifícios altos modernos são estruturas, em geral, leves, flexíveis e pouco amortecidas, o que os torna mais susceptíveis a problemas causados por vibrações induzidas pela ação do vento. Estes problemas podem gerar desconforto aos usuários ou até mesmo, em casos mais severos, danos estruturais. O agrupamento de edifícios propicia o surgimento de efeitos de interferência, que alteram o escoamento em torno das estruturas e, consequentemente, o carregamento devido à ação do vento. Forças aerodinâmicas e a resposta de edifícios altos a ação destas forças podem aumentar ou diminuir significativamente devido à presença de edificações vizinhas. Devido à complexidade dos efeitos de interferência entre edifícios, há ainda muitas lacunas no entendimento do fenômeno, embora o assunto seja estudado por diversos pesquisadores desde a década de 1930. Com o objetivo de contribuir para o estadoda- arte do conhecimento do fenômeno de efeitos de interferência em edifícios altos, neste trabalho foram realizados ensaios em túnel de vento com modelo reduzido do edifício padrão da Commonwealth Aeronautical Research Council (CAARC) para 18 configurações de vizinhança. Para determinação da resposta do edifício, em termos de suas componentes médias e flutuantes, para deslocamentos longitudinais e transversais à direção do vento incidente e a torção, utilizou-se uma balança dinâmica de três graus de liberdade (BD3GDL), dois em flexão, admitindo que são ortogonais entre si e aproximados de forma linear, e um torção, aproximado de forma constante. A presença de edificações vizinhas causou, em geral, o efeito de proteção esperado provocando a diminuição das respostas médias longitudinal e transversal do edifício principal, quando comparada à resposta da edificação isolada. No entanto, a resposta flutuante sofreu amplificações significativas, para os três graus de liberdade, para determinadas configurações de vizinhança. / The population explosion in modern cities has generated a need for the better use of urban spaces, contributing to the vertical growth and densification of built-up areas. Considering this, current trends are to build taller towers with minimal space between buildings; two characteristics which influence the structural response of buildings under wind loading. In general, modern tall buildings are lightweight, flexible structures with low levels of inherent structural damping, which render them highly susceptible to problems caused by windinduced vibrations. These problems include discomfort suffered by building tenants, and in severe cases, damage to the building’s structure. The close grouping of buildings increases interference effects, altering the flow around buildings, and consequentially the loading caused by the wind. The aerodynamic forces, and associated responses, of tall-buildings can be significantly increased or reduced by the presence of neighboring buildings. Due to the complexity of inference effects between buildings, there remain many unknowns in the understanding of the phenomenon, even though the subject has been studied by many researchers since the 1930s. It is with the objective of contributing to the state-of-the-art of the building interference effects that, in this study, wind-tunnel investigations were performed on the reduced scaled model building of the internationally recognized benchmark Commonwealth Aeronautical Research Council (CAARC) design for 18 different neighboring configurations. For the determination of the building’s response, in terms of mean and fluctuating components of along-wind and cross-wind displacements and torsion, the three degrees-of-freedom dynamic balance (BD3GDL) was utilized; which possesses two degreesof- freedom in linear bending along the orthogonal directions, and a constant rotation about its vertical axis. The presence of neighboring buildings generally provided the study building with protection, as was predicted, causing the reduction of mean displacements in both alongwind and cross-wind directions when compared against the isolated case. However, the fluctuating response in all three degrees-of-freedom suffered significant increases for certain proximity building configurations.
3

Determinação dos efeitos de vizinhança na resposta dinâmica de edifícios altos sob a ação do vento / Determination of the effects of neighbouring buildings on the dynamic response of tall buildings under wind loading

Bênia, Maria Cristina Dolz January 2013 (has links)
O processo de crescimento das cidades gerou uma necessidade pelo melhor aproveitamento do espaço urbano, contribuindo para os processos de verticalização e densificação das áreas construídas. Sendo assim, a tendência é de construção de edifícios cada vez mais altos e agrupados, duas características que influenciam na resposta das estruturas à ação do vento. Edifícios altos modernos são estruturas, em geral, leves, flexíveis e pouco amortecidas, o que os torna mais susceptíveis a problemas causados por vibrações induzidas pela ação do vento. Estes problemas podem gerar desconforto aos usuários ou até mesmo, em casos mais severos, danos estruturais. O agrupamento de edifícios propicia o surgimento de efeitos de interferência, que alteram o escoamento em torno das estruturas e, consequentemente, o carregamento devido à ação do vento. Forças aerodinâmicas e a resposta de edifícios altos a ação destas forças podem aumentar ou diminuir significativamente devido à presença de edificações vizinhas. Devido à complexidade dos efeitos de interferência entre edifícios, há ainda muitas lacunas no entendimento do fenômeno, embora o assunto seja estudado por diversos pesquisadores desde a década de 1930. Com o objetivo de contribuir para o estadoda- arte do conhecimento do fenômeno de efeitos de interferência em edifícios altos, neste trabalho foram realizados ensaios em túnel de vento com modelo reduzido do edifício padrão da Commonwealth Aeronautical Research Council (CAARC) para 18 configurações de vizinhança. Para determinação da resposta do edifício, em termos de suas componentes médias e flutuantes, para deslocamentos longitudinais e transversais à direção do vento incidente e a torção, utilizou-se uma balança dinâmica de três graus de liberdade (BD3GDL), dois em flexão, admitindo que são ortogonais entre si e aproximados de forma linear, e um torção, aproximado de forma constante. A presença de edificações vizinhas causou, em geral, o efeito de proteção esperado provocando a diminuição das respostas médias longitudinal e transversal do edifício principal, quando comparada à resposta da edificação isolada. No entanto, a resposta flutuante sofreu amplificações significativas, para os três graus de liberdade, para determinadas configurações de vizinhança. / The population explosion in modern cities has generated a need for the better use of urban spaces, contributing to the vertical growth and densification of built-up areas. Considering this, current trends are to build taller towers with minimal space between buildings; two characteristics which influence the structural response of buildings under wind loading. In general, modern tall buildings are lightweight, flexible structures with low levels of inherent structural damping, which render them highly susceptible to problems caused by windinduced vibrations. These problems include discomfort suffered by building tenants, and in severe cases, damage to the building’s structure. The close grouping of buildings increases interference effects, altering the flow around buildings, and consequentially the loading caused by the wind. The aerodynamic forces, and associated responses, of tall-buildings can be significantly increased or reduced by the presence of neighboring buildings. Due to the complexity of inference effects between buildings, there remain many unknowns in the understanding of the phenomenon, even though the subject has been studied by many researchers since the 1930s. It is with the objective of contributing to the state-of-the-art of the building interference effects that, in this study, wind-tunnel investigations were performed on the reduced scaled model building of the internationally recognized benchmark Commonwealth Aeronautical Research Council (CAARC) design for 18 different neighboring configurations. For the determination of the building’s response, in terms of mean and fluctuating components of along-wind and cross-wind displacements and torsion, the three degrees-of-freedom dynamic balance (BD3GDL) was utilized; which possesses two degreesof- freedom in linear bending along the orthogonal directions, and a constant rotation about its vertical axis. The presence of neighboring buildings generally provided the study building with protection, as was predicted, causing the reduction of mean displacements in both alongwind and cross-wind directions when compared against the isolated case. However, the fluctuating response in all three degrees-of-freedom suffered significant increases for certain proximity building configurations.
4

Determinação experimental em túnel de vento dos efeitos estáticos de proteção causados por edificações vizinhas : contribuição para a revisão dos fatores de vizinhança da NBR-6123 / Experimental determination in wind tunnel tests of statics protection effects caused by neighboring buildings : contribution to the review of neghborhood factors of NBR-6123

Alberti, Franco Augusto January 2015 (has links)
Efeitos de interferência aerodinâmica por vizinhança ocorrem inevitavelmente em edificações imersas em contexto urbano. Com base nas características da vizinhança que envolve o entorno de uma edificação, estes efeitos consequentemente podem reduzir ou majorar as ações do vento sobre a mesma. Tendo em vista a complexidade do problema em estimar o real ambiente em que um edifício estará situado e sua influência no comportamento do vento, torna-se muito difícil a codificação destes efeitos em documentos normativos, específicos para cada situação de projeto. No entanto, fatores de redução e majoração das ações do vento sobre as edificações podem ser determinados de acordo com as características da vizinhança presente no ambiente em que estão inseridas. Neste trabalho são analisados quatro modelos reduzidos de edifícios altos e suas vizinhanças adjacentes. Os modelos foram testados em túnel de vento, no Laboratório de Aerodinâmica das Construções da Universidade Federal do Rio Grande do Sul, sob duas configurações de ensaios, uma com a edificação isolada e outra com a edificação na presença da vizinhança na qual estará imerso. A partir dos resultados obtidos no túnel, foram calculados coeficientes de força para cada modelo, em relação a dois eixos ortogonais com origem próxima ao centro de torção da secção transversal correspondente ao pavimento tipo. Dos quatro casos estudados, todos apresentaram variações significativas dos coeficientes de força quando na presença de edificações vizinhas. Para estes edifícios, foram calculados fatores de vizinhança respectivos aos ângulos de vento mais influentes ao dimensionamento estrutural dos mesmos. A respeito das análises, notou-se que sob vizinhança densa, houve uma grande redução das ações do vento, enquanto que brechas entre as estruturas de interferência, traduziram em aumentos das ações do vento sobre as edificações estudadas. / Neighborhood interference effects due to nearby strucutres, inevitably occur on buildings immersed in urban context. Based on the characteristics of the neighborhood surrounding the vicinity of a building, these effects therefore can reduce or increase wind actions. Given the complexity of the problem in estimating the real environment where a building is located and its influence on wind behavior, it is extreme hard to encode these effects in regulation codes by specifying situations for each proposed project. However, reduction and increase factors on the wind actions over buildings can be determined according to the caracteristics of its neighborhood at the environment in which they locate. This paper analyzes four scale models of tall buildings and its surrounding structures. The models were tested in the wind tunnel at the Laboratório de Aerodinâmica das Construções of the Universidade Federal do Rio Grande do Sul, in two configurations tests, one with the building in isolated situation and the other with the building in the corresponding vicinity. The results obtained in the wind tunnel tests were used to determine strength coefficients for each model in relation to the both orthogonal axes with its origin near the torsional center of the transversal section correspondent to the standard floor of the buildings. For the four cases studied, all the test results showed significant variations at force coefficients in the presence of neighboring structures. For each case studied, interference factors were calculated due to sorrounding structures for the most influential wind angles for the structural design. Regarding the analysis it was noticed that under dense neighborhood, there was a large reduction of the wind loads, while gaps between interference structures resulted in increases of wind actions over the studied buildings.
5

Determinação dos efeitos de vizinhança na resposta dinâmica de edifícios altos sob a ação do vento / Determination of the effects of neighbouring buildings on the dynamic response of tall buildings under wind loading

Bênia, Maria Cristina Dolz January 2013 (has links)
O processo de crescimento das cidades gerou uma necessidade pelo melhor aproveitamento do espaço urbano, contribuindo para os processos de verticalização e densificação das áreas construídas. Sendo assim, a tendência é de construção de edifícios cada vez mais altos e agrupados, duas características que influenciam na resposta das estruturas à ação do vento. Edifícios altos modernos são estruturas, em geral, leves, flexíveis e pouco amortecidas, o que os torna mais susceptíveis a problemas causados por vibrações induzidas pela ação do vento. Estes problemas podem gerar desconforto aos usuários ou até mesmo, em casos mais severos, danos estruturais. O agrupamento de edifícios propicia o surgimento de efeitos de interferência, que alteram o escoamento em torno das estruturas e, consequentemente, o carregamento devido à ação do vento. Forças aerodinâmicas e a resposta de edifícios altos a ação destas forças podem aumentar ou diminuir significativamente devido à presença de edificações vizinhas. Devido à complexidade dos efeitos de interferência entre edifícios, há ainda muitas lacunas no entendimento do fenômeno, embora o assunto seja estudado por diversos pesquisadores desde a década de 1930. Com o objetivo de contribuir para o estadoda- arte do conhecimento do fenômeno de efeitos de interferência em edifícios altos, neste trabalho foram realizados ensaios em túnel de vento com modelo reduzido do edifício padrão da Commonwealth Aeronautical Research Council (CAARC) para 18 configurações de vizinhança. Para determinação da resposta do edifício, em termos de suas componentes médias e flutuantes, para deslocamentos longitudinais e transversais à direção do vento incidente e a torção, utilizou-se uma balança dinâmica de três graus de liberdade (BD3GDL), dois em flexão, admitindo que são ortogonais entre si e aproximados de forma linear, e um torção, aproximado de forma constante. A presença de edificações vizinhas causou, em geral, o efeito de proteção esperado provocando a diminuição das respostas médias longitudinal e transversal do edifício principal, quando comparada à resposta da edificação isolada. No entanto, a resposta flutuante sofreu amplificações significativas, para os três graus de liberdade, para determinadas configurações de vizinhança. / The population explosion in modern cities has generated a need for the better use of urban spaces, contributing to the vertical growth and densification of built-up areas. Considering this, current trends are to build taller towers with minimal space between buildings; two characteristics which influence the structural response of buildings under wind loading. In general, modern tall buildings are lightweight, flexible structures with low levels of inherent structural damping, which render them highly susceptible to problems caused by windinduced vibrations. These problems include discomfort suffered by building tenants, and in severe cases, damage to the building’s structure. The close grouping of buildings increases interference effects, altering the flow around buildings, and consequentially the loading caused by the wind. The aerodynamic forces, and associated responses, of tall-buildings can be significantly increased or reduced by the presence of neighboring buildings. Due to the complexity of inference effects between buildings, there remain many unknowns in the understanding of the phenomenon, even though the subject has been studied by many researchers since the 1930s. It is with the objective of contributing to the state-of-the-art of the building interference effects that, in this study, wind-tunnel investigations were performed on the reduced scaled model building of the internationally recognized benchmark Commonwealth Aeronautical Research Council (CAARC) design for 18 different neighboring configurations. For the determination of the building’s response, in terms of mean and fluctuating components of along-wind and cross-wind displacements and torsion, the three degrees-of-freedom dynamic balance (BD3GDL) was utilized; which possesses two degreesof- freedom in linear bending along the orthogonal directions, and a constant rotation about its vertical axis. The presence of neighboring buildings generally provided the study building with protection, as was predicted, causing the reduction of mean displacements in both alongwind and cross-wind directions when compared against the isolated case. However, the fluctuating response in all three degrees-of-freedom suffered significant increases for certain proximity building configurations.
6

Determinação experimental em túnel de vento dos efeitos estáticos de proteção causados por edificações vizinhas : contribuição para a revisão dos fatores de vizinhança da NBR-6123 / Experimental determination in wind tunnel tests of statics protection effects caused by neighboring buildings : contribution to the review of neghborhood factors of NBR-6123

Alberti, Franco Augusto January 2015 (has links)
Efeitos de interferência aerodinâmica por vizinhança ocorrem inevitavelmente em edificações imersas em contexto urbano. Com base nas características da vizinhança que envolve o entorno de uma edificação, estes efeitos consequentemente podem reduzir ou majorar as ações do vento sobre a mesma. Tendo em vista a complexidade do problema em estimar o real ambiente em que um edifício estará situado e sua influência no comportamento do vento, torna-se muito difícil a codificação destes efeitos em documentos normativos, específicos para cada situação de projeto. No entanto, fatores de redução e majoração das ações do vento sobre as edificações podem ser determinados de acordo com as características da vizinhança presente no ambiente em que estão inseridas. Neste trabalho são analisados quatro modelos reduzidos de edifícios altos e suas vizinhanças adjacentes. Os modelos foram testados em túnel de vento, no Laboratório de Aerodinâmica das Construções da Universidade Federal do Rio Grande do Sul, sob duas configurações de ensaios, uma com a edificação isolada e outra com a edificação na presença da vizinhança na qual estará imerso. A partir dos resultados obtidos no túnel, foram calculados coeficientes de força para cada modelo, em relação a dois eixos ortogonais com origem próxima ao centro de torção da secção transversal correspondente ao pavimento tipo. Dos quatro casos estudados, todos apresentaram variações significativas dos coeficientes de força quando na presença de edificações vizinhas. Para estes edifícios, foram calculados fatores de vizinhança respectivos aos ângulos de vento mais influentes ao dimensionamento estrutural dos mesmos. A respeito das análises, notou-se que sob vizinhança densa, houve uma grande redução das ações do vento, enquanto que brechas entre as estruturas de interferência, traduziram em aumentos das ações do vento sobre as edificações estudadas. / Neighborhood interference effects due to nearby strucutres, inevitably occur on buildings immersed in urban context. Based on the characteristics of the neighborhood surrounding the vicinity of a building, these effects therefore can reduce or increase wind actions. Given the complexity of the problem in estimating the real environment where a building is located and its influence on wind behavior, it is extreme hard to encode these effects in regulation codes by specifying situations for each proposed project. However, reduction and increase factors on the wind actions over buildings can be determined according to the caracteristics of its neighborhood at the environment in which they locate. This paper analyzes four scale models of tall buildings and its surrounding structures. The models were tested in the wind tunnel at the Laboratório de Aerodinâmica das Construções of the Universidade Federal do Rio Grande do Sul, in two configurations tests, one with the building in isolated situation and the other with the building in the corresponding vicinity. The results obtained in the wind tunnel tests were used to determine strength coefficients for each model in relation to the both orthogonal axes with its origin near the torsional center of the transversal section correspondent to the standard floor of the buildings. For the four cases studied, all the test results showed significant variations at force coefficients in the presence of neighboring structures. For each case studied, interference factors were calculated due to sorrounding structures for the most influential wind angles for the structural design. Regarding the analysis it was noticed that under dense neighborhood, there was a large reduction of the wind loads, while gaps between interference structures resulted in increases of wind actions over the studied buildings.
7

Determinação experimental em túnel de vento dos efeitos estáticos de proteção causados por edificações vizinhas : contribuição para a revisão dos fatores de vizinhança da NBR-6123 / Experimental determination in wind tunnel tests of statics protection effects caused by neighboring buildings : contribution to the review of neghborhood factors of NBR-6123

Alberti, Franco Augusto January 2015 (has links)
Efeitos de interferência aerodinâmica por vizinhança ocorrem inevitavelmente em edificações imersas em contexto urbano. Com base nas características da vizinhança que envolve o entorno de uma edificação, estes efeitos consequentemente podem reduzir ou majorar as ações do vento sobre a mesma. Tendo em vista a complexidade do problema em estimar o real ambiente em que um edifício estará situado e sua influência no comportamento do vento, torna-se muito difícil a codificação destes efeitos em documentos normativos, específicos para cada situação de projeto. No entanto, fatores de redução e majoração das ações do vento sobre as edificações podem ser determinados de acordo com as características da vizinhança presente no ambiente em que estão inseridas. Neste trabalho são analisados quatro modelos reduzidos de edifícios altos e suas vizinhanças adjacentes. Os modelos foram testados em túnel de vento, no Laboratório de Aerodinâmica das Construções da Universidade Federal do Rio Grande do Sul, sob duas configurações de ensaios, uma com a edificação isolada e outra com a edificação na presença da vizinhança na qual estará imerso. A partir dos resultados obtidos no túnel, foram calculados coeficientes de força para cada modelo, em relação a dois eixos ortogonais com origem próxima ao centro de torção da secção transversal correspondente ao pavimento tipo. Dos quatro casos estudados, todos apresentaram variações significativas dos coeficientes de força quando na presença de edificações vizinhas. Para estes edifícios, foram calculados fatores de vizinhança respectivos aos ângulos de vento mais influentes ao dimensionamento estrutural dos mesmos. A respeito das análises, notou-se que sob vizinhança densa, houve uma grande redução das ações do vento, enquanto que brechas entre as estruturas de interferência, traduziram em aumentos das ações do vento sobre as edificações estudadas. / Neighborhood interference effects due to nearby strucutres, inevitably occur on buildings immersed in urban context. Based on the characteristics of the neighborhood surrounding the vicinity of a building, these effects therefore can reduce or increase wind actions. Given the complexity of the problem in estimating the real environment where a building is located and its influence on wind behavior, it is extreme hard to encode these effects in regulation codes by specifying situations for each proposed project. However, reduction and increase factors on the wind actions over buildings can be determined according to the caracteristics of its neighborhood at the environment in which they locate. This paper analyzes four scale models of tall buildings and its surrounding structures. The models were tested in the wind tunnel at the Laboratório de Aerodinâmica das Construções of the Universidade Federal do Rio Grande do Sul, in two configurations tests, one with the building in isolated situation and the other with the building in the corresponding vicinity. The results obtained in the wind tunnel tests were used to determine strength coefficients for each model in relation to the both orthogonal axes with its origin near the torsional center of the transversal section correspondent to the standard floor of the buildings. For the four cases studied, all the test results showed significant variations at force coefficients in the presence of neighboring structures. For each case studied, interference factors were calculated due to sorrounding structures for the most influential wind angles for the structural design. Regarding the analysis it was noticed that under dense neighborhood, there was a large reduction of the wind loads, while gaps between interference structures resulted in increases of wind actions over the studied buildings.
8

Liens entre mémoire et perception : vers des mécanismes communs / Links between memory and perception : towards common mechanisms

Rey, Amandine 22 September 2014 (has links)
Dans notre vie quotidienne, nous recueillons et intégrons constamment un grand nombre d’informations sensorielles (Calvert & Thesen, 2004). Tout au long de nos activités perceptives, les connaissances que nous avons sur l’environnement sont continuellement "récupérées" en mémoire. Le cadre de la cognition incarnée et située proposent que les processus cognitifs (i.e. processus mnésiques, processus langagiers) sont ancrés dans les mêmes systèmes sensorimoteurs que ceux engagés dans les processus perceptivo-moteurs (Glenberg, 1997 ; Slotnick, 2004 ; Pecher & Zwaan, 2005).La mémoire contient des traces sensori-motrices encodées lors des multiples expériences de l’individu dans son environnement (Versace, Labeye, Badard, & Rose, 2009). De nombreux travaux en psychologie cognitive et en neurosciences démontrent que les connaissances sont construites et (re)émergent à partir de l’activation des systèmes neuronaux typiquement associés aux mécanismes perceptivo-moteurs. Le contenu et le fonctionnement de notre mémoire sont intrinsèquement liés à nos activités sensori-motrices passées et présentes. Pour être efficace, les connaissances impliquées dans nos activités cognitives doivent être étroitement liées à la situation présente. Cette capacité à s’adapter à des situations spécifiques ne serait pas possible à moins que les connaissances, y compris les connaissances conceptuelles, soientissues de la réactivation de traces mnésiques d’expériences passées (Barsalou, 2008 ; Versace et al., 2014). Réciproquement, les activités sensori-motrices sont totalement dépendantes des traces mnésiques d’expériences sensori-motrices passées. Ainsi, la différence entre perception et mémoire réside dans le fait que, dans le premier cas, les propriétés sont perceptivement présentes, tandis que, dans le deuxième cas, celles-ci sont absentes mais réactivées.Ce travail de thèse avait pour objectif d’étudier les liens entre mémoire et perception et, plus précisément, d’apporter des arguments en faveur de la similarité entre les processus mnésiques et perceptifs qui résultent de l’activation de composants de même nature sensorimotrice.Nous avons testé l’hypothèse selon laquelle des effets perceptifs devraient pouvoir être obtenus avec des composants réactivés en mémoire. Pour cela, nous avons utilisé des effets perceptifs - tels que l’effet de masquage ou les biais de jugement perceptif - afin d’explorer la possibilité de répliquer ce type d’effets avec l’intervention des dimensions mnésiques. / In everyday life, each of us is constantly processing perceptual input from the environment, we collect and then integrate numerous items of sensory information (Calvert & Thesen, 2004). Alongside these perceptual activities, knowledge related to our environment is continually "recovered" from memory. Embodied cognition and grounded cognition theories suggest that cognitive processes (e.g., memory processes, language processes) are grounded in the same sensory-motor systems as those used in perceptual and motor processes (Glenberg, 1997 ; Slotnick, 2004 ; Pecher & Zwaan, 2005).Memory is composed of sensorimotor traces encoded during the several experiences of an individual in his environment (Versace et al., 2009). A large number of studies in cognitive psychology and neurosciences demonstrated that knowledge is constructed and (re)emerged from the activation of neural systems typically associated with perceptual-motor mechanisms. The contents and the functioning of our memory are intrinsically linked to our past and present sensorimotor activities. To be effective, knowledge involved in our cognitive activities must be closely linked to the actual situation. This ability to adapt to specific situations would not be possible unless knowledge, including conceptual knowledge, is derived from the reactivation of memory traces of past experiences (Barsalou, 2008 ; Versace et al., 2014). Conversely, sensorimotor activities are totally dependent on memory traces of past sensorimotor experiences. Thus, the difference between perception and memory is that, in the former, properties are perceptually present, whereas, in the latter, they are absent but reactivated. This PhD research focused on the link between memory and perception and, more precisely, aims to provide arguments in favor of the similarity of memory and perceptual processes that result from the activation of components of same sensorimotor nature. We tested the hypothesis that perceptual effects should be observed with reactivated components in memory. We used well-known perceptual effects (such as masking effect or perceptual bias invisual illusion) to investigate the possibility to replicate these effects by replacing the sensorial present components by reactivated components in memory.
9

Caracterização aerodinâmica de edifícios altos com planta em formato de “V” através de análise espectral

Vogado, Monique Wesz January 2018 (has links)
Nas últimas décadas, tem-se observado uma forte tendência de edificações cada vez mais altas, esbeltas e flexíveis, o que exigiu novas considerações no cálculo estrutural de edifícios, tornando a ação do vento um elemento de grande relevância nos projetos. Além disso, o denso agrupamento de edificações nos centros de grandes cidades adicionou uma variável para um fenômeno que já era complexo: devido à proximidade, um edifício passa a influenciar o campo aerodinâmico de outros, podendo provocar grandes alterações nas pressões, além de fenômenos dinâmicos difíceis de determinar por métodos analíticos. Instruções normativas, em geral, limitam-se a prédios altos com padrões arquitetônicos regulares, afastando-se da realidade dos projetos construídos na prática, que vêm exibindo geometrias cada vez mais complexas e não convencionais. Este cenário justifica a realização de extensos estudos dentro do tema em questão, a fim de que se obtenha uma melhor compreensão dos fenômenos dinâmicos envolvidos e uma orientação mais abrangente na etapa de pré-dimensionamento da estrutura. Neste contexto, a proposta desta pesquisa consiste em dois estudos de caso, de edifícios construídos no Brasil e ensaiados em túnel de vento, que possuem uma geometria similar (em formato de “V”), mas com dimensões e detalhes arquitetônicos distintos. O objetivo é o de promover uma caracterização aerodinâmica, avaliando os carregamentos atuando global e localmente, tanto para o modelo considerado isolado quanto incluindo as condições de vizinhança. Além das ações, estudou-se o espectro do vento que se aproxima, e determinou-se as funções de admitância aerodinâmica correspondentes. Em ambos os edifícios, verificou-se que a incidência do vento aproximadamente perpendicular a uma das abas corresponde a uma direção crítica em termos de efeitos dinâmicos: os espectros dos carregamentos globais se mostraram muito similares, apresentando picos pronunciados que indicam a possibilidade de desprendimento cadenciado de vórtices; as funções de admitância aerodinâmica também evidenciaram um formato muito semelhante. O estudo em questão oferece um meio de validação para estudos futuros que utilizem modelos de ensaio simplificados, além de servir de referência para uma possível revisão da norma brasileira NBR 6123/1988 – Forças devidas ao vento em edificações, contribuindo com os avanços do conhecimento relativo a efeitos dinâmicos do vento em edifícios altos e irregulares. / In the last decades we observed a strong trend in constructing buildings increasingly tall, slender and flexible, which has asked for new consideration in the structural calculus of buildings, making the wind a relevant element in the design procedures. The grouping of buildings downtown in big cities has added another variable to an already complex phenomenon: due to the proximity, a building influences in the aerodynamic field of others, leading to pressure modifications and dynamic effects hard to determine by analytical methods. Instruction codes, in general, are limited to regular tall buildings, in contrast to the reality of projects built in practice, which have been exhibiting architectonic patterns increasingly complex and unconventional. This scenario justifies extensive studies among aerodynamic of irregular tall buildings, with the purpose of acquiring a better comprehension regarding the dynamic phenomena involved and a more accurate direction on the pre-design phase. In this context, the proposal of this research consists of two case studies about buildings constructed in Brazil and tested in wind tunnel, which have a similar geometry (V-shaped) but different dimensions and architectonic details. The objective is to promote a complete aerodynamic characterization, assessing the loads acting as a whole and also locally, with both isolated and interference conditions. Besides the action, the velocity spectrum of the approaching wind and the corresponding aerodynamic admittance were studied. Either case, it was verified that the wind incidence nearly perpendicular to one of the frontal facades is a critical direction from the perspective of dynamic effects: the spectra of global loads were very similar, with a peak emerging on the graphs, which indicate the possibility of vortex shedding; the admittance function also showed a very close format. This study offers an instrument of validation for future researches that use simplified test models, besides to fit as a reference to a possible revision of the Brazilian code NBR 6123/1988 – Wind load on building structures, contributing to the knowledge advances regarding dynamic effects on irregular tall buildings.
10

Caracterização aerodinâmica de edifícios altos com planta em formato de “V” através de análise espectral

Vogado, Monique Wesz January 2018 (has links)
Nas últimas décadas, tem-se observado uma forte tendência de edificações cada vez mais altas, esbeltas e flexíveis, o que exigiu novas considerações no cálculo estrutural de edifícios, tornando a ação do vento um elemento de grande relevância nos projetos. Além disso, o denso agrupamento de edificações nos centros de grandes cidades adicionou uma variável para um fenômeno que já era complexo: devido à proximidade, um edifício passa a influenciar o campo aerodinâmico de outros, podendo provocar grandes alterações nas pressões, além de fenômenos dinâmicos difíceis de determinar por métodos analíticos. Instruções normativas, em geral, limitam-se a prédios altos com padrões arquitetônicos regulares, afastando-se da realidade dos projetos construídos na prática, que vêm exibindo geometrias cada vez mais complexas e não convencionais. Este cenário justifica a realização de extensos estudos dentro do tema em questão, a fim de que se obtenha uma melhor compreensão dos fenômenos dinâmicos envolvidos e uma orientação mais abrangente na etapa de pré-dimensionamento da estrutura. Neste contexto, a proposta desta pesquisa consiste em dois estudos de caso, de edifícios construídos no Brasil e ensaiados em túnel de vento, que possuem uma geometria similar (em formato de “V”), mas com dimensões e detalhes arquitetônicos distintos. O objetivo é o de promover uma caracterização aerodinâmica, avaliando os carregamentos atuando global e localmente, tanto para o modelo considerado isolado quanto incluindo as condições de vizinhança. Além das ações, estudou-se o espectro do vento que se aproxima, e determinou-se as funções de admitância aerodinâmica correspondentes. Em ambos os edifícios, verificou-se que a incidência do vento aproximadamente perpendicular a uma das abas corresponde a uma direção crítica em termos de efeitos dinâmicos: os espectros dos carregamentos globais se mostraram muito similares, apresentando picos pronunciados que indicam a possibilidade de desprendimento cadenciado de vórtices; as funções de admitância aerodinâmica também evidenciaram um formato muito semelhante. O estudo em questão oferece um meio de validação para estudos futuros que utilizem modelos de ensaio simplificados, além de servir de referência para uma possível revisão da norma brasileira NBR 6123/1988 – Forças devidas ao vento em edificações, contribuindo com os avanços do conhecimento relativo a efeitos dinâmicos do vento em edifícios altos e irregulares. / In the last decades we observed a strong trend in constructing buildings increasingly tall, slender and flexible, which has asked for new consideration in the structural calculus of buildings, making the wind a relevant element in the design procedures. The grouping of buildings downtown in big cities has added another variable to an already complex phenomenon: due to the proximity, a building influences in the aerodynamic field of others, leading to pressure modifications and dynamic effects hard to determine by analytical methods. Instruction codes, in general, are limited to regular tall buildings, in contrast to the reality of projects built in practice, which have been exhibiting architectonic patterns increasingly complex and unconventional. This scenario justifies extensive studies among aerodynamic of irregular tall buildings, with the purpose of acquiring a better comprehension regarding the dynamic phenomena involved and a more accurate direction on the pre-design phase. In this context, the proposal of this research consists of two case studies about buildings constructed in Brazil and tested in wind tunnel, which have a similar geometry (V-shaped) but different dimensions and architectonic details. The objective is to promote a complete aerodynamic characterization, assessing the loads acting as a whole and also locally, with both isolated and interference conditions. Besides the action, the velocity spectrum of the approaching wind and the corresponding aerodynamic admittance were studied. Either case, it was verified that the wind incidence nearly perpendicular to one of the frontal facades is a critical direction from the perspective of dynamic effects: the spectra of global loads were very similar, with a peak emerging on the graphs, which indicate the possibility of vortex shedding; the admittance function also showed a very close format. This study offers an instrument of validation for future researches that use simplified test models, besides to fit as a reference to a possible revision of the Brazilian code NBR 6123/1988 – Wind load on building structures, contributing to the knowledge advances regarding dynamic effects on irregular tall buildings.