• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do oxigênio nas propriedades anelásticas e biocompatibilidade das ligas de Ti-8%pTa e Ti-16%pTa utilizadas como biomaterial /

Ruiz, Samira Lea Medina. January 2010 (has links)
Orientador: Carlos Roberto Grandini / Banca: Paulo Afonso Silveira Francisconi / Banca: Ana Paula Rosifini Alves Claro / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: O crescente aumenta na expectativa de vida da população tem resultado numa igual demanda e procura por biomateriais metálicos. Biomateriais metálicos são utilizados na substituição ou recuperação de ombros, joelhos, quadril e cotovelos. As ligas a base de Ti são materiais promissores para tais fins, pois apresentam uma excelente biocompatibilidade, ótima resistência à corrosão em meio biológico. Essas características são grandemente influenciadas pela presença de elementos substitucionais e oxigênio intersticial e a técnica do atrito interno constitui um aliado bastante importante na análise dos resultados deste trabalho. Dessa forma, o objetivo deste trabalho é analisar a influência do exigênio intersticial nas propriedades das ligas Ti-8Ta e Ti-16Ta (% em peso). As medidas de atrito interno foram utilizadas para obtenção do módulo de elasticidade dinâmico das ligas estudadas, pois esta grandeza está experimentalmente associada ao amortecimento das vibrações livres do sistema, a dissipação de energia elástica e a frequencia de oscilação do sistema. Para tais medidas empregou-se um Pêndulo de Torção com frequencia de oscilação de aproximadamente 30Hz e temperatura na faixa de 230 a 350K. As ligas estudadas passaram por processos de tratamento térmico e dopagens com oxigênio e foram caracterizadas por medidas de densidade, difração de raios X e posterior refinamento de Rietveld, microdureza, módulo de elasticidade e testes de citotoxicidade in vitro. Os testes iniciais de biocompatibilidade mostram que não houve nenhuma resposta citotóxica, originando resposta celular satisfatória. As medidas de microdureza apresentam valores menores que os encontrados na literatura e as medidas de raios X mostram picos característicos da fase 'alfa' do titânio. Na análise de Rietveld verificou-se a presença de estrutura martensítica 'alfa' e fase 'beta' para ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The accelerating increase in life expectancy of the population has resulted in greater demand and more searches for metallic biomaterials. Metallic are extensively used in the replacement or restoration fo shoulders, knees, hips and elbows. Ti-based alloys are promising materials for such purposes, because they present excellent biocompatibility, a great mechanical strengh/density relation and a high corrosion resistance in a biological medium. These characteristics are greatly influenced by the presence of substitutional elements and interstitial oxygen. The internal friction technique is a very important ally in the analysis of the results of this work. Thus, the purpose of this work is to analyze the influence of insterstitial oxygen on the properties of Ti-8Ta and Ti-16Ta alloys (wt%). Internal friction measurements were used to obtain the dynamic elasticity modulus of the alloys studied, because this quantity is experimentally associated with the damping of free vibration of the sytem, which is related to the elastic energy dissipation and the oscillation frequency of the system. For such measurements, a torsion pendulum was employed, with an oscillation frequency of approximately 30 Hz and temperature in the range of 230-350 K. The alloys underwent heat treatment and oxygen doping processes, and were characterized by density, x-ray diffraction and subsequent refinement of Rietveld, microhardness and elasticity modulus measurements, and in vitro cytotoxicity tests. The initial biocompatibility tests showed that there was no cytotoxic answer, giving origin to a satisfactory cellular response. Microhardness measurements had values less than found in the literature, and x-rays showed characteristic peak of the titanium 'alfa' phase. In the Rietveld analysis, observed were the presence of martensitic 'alfa' structure and a 'beta' phase for all sample and conditions studied. The ... (Complete abstract click electronic access below) / Mestre
2

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo /

Martins Júnior, José Roberto Severino. January 2010 (has links)
Orientador: Carlos Roberto Grandini / Banca: Marize Varella de Oliveira / Banca: Nilson Tadeu Camarinho de Oliveira / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Desde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatível / Abstract: Since 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatible / Mestre

Page generated in 0.1084 seconds