• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 3
  • 1
  • Tagged with
  • 76
  • 76
  • 41
  • 32
  • 23
  • 23
  • 23
  • 17
  • 16
  • 15
  • 14
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Desenvolvimento da metodologia para síntese do poli(ácido lático-co-ácido glicólico) para utilização na produção de fontes radioativas / Development of methodology for the synthesis of poly(lactic acid-co-glycolic acid) for use in the production of radioactive sources

Fernando dos Santos Peleias Júnior 26 July 2013 (has links)
A Organização Mundial da Saúde (OMS) relata o câncer como uma das principais causas de morte no mundo. O câncer de próstata é o segundo tipo de câncer mais prevalente em homens. Uma modalidade de tratamento que vem sendo bastante utilizada é a braquiterapia, que consiste na introdução de sementes com material radioativo no interior do orgão. Sementes de Iodo-125 podem ser inseridas soltas ou em cordas poliméricas bioabsorvíveis. As sementes em cordas poliméricas apresentam algumas vantagens, pois reduzem a taxa de migração das sementes, evento que poderia afetar a dosimetria da região e causar danos desnecessários a tecidos ou órgãos sadios. Para as sementes de Iodo-125 em cordas poliméricas, utiliza-se a poliglactina 910, (poli(ácido lático-co-ácido glicólico)) (PLGA), com cobertura de poliglactina 370 (Vicryl®). Foi proposto neste trabalho, o estudo e desenvolvimento da metodologia de síntese do biopolímero PLGA, via polimerização por abertura de anéis, assim como sua caracterização, com o propósito de utilizar o material sintetizado para fabricar um material similar ao RAPID-Strand®. Os resultados obtidos demonstram que, através da metodologia utilizada, foi possível determinar os melhores parâmetros de reação (tempo e temperatura) para o PLGA na proporção 80/20 (lactídeo/glicolídeo). Com uma temperatura de 110ºC e tempo de reação de 24h, foi possível obter 86% de rendimento, e com o aumento o tempo de reação para 72h, o rendimento é superior a 90%. Os valores de massas moleculares obtidas entre os testes, ainda são muito baixos quando comparados com os valores obtidos por outros autores na literatura (cerca de 20%). Falhas na selagem das ampolas, deixando-os vulneráveis à umidade e oxigênio, ou a falta de uma sistema eficiente de agitação podem ser possíveis explicações para estes resultados. Um reator químico adequado poderia solucionar o problema. Em relação à caracterização, as técnicas utilizadas confirmaram a estrutura esperada do polímero, e a maior proporção das unidades provenientes do dímero lactídeo, em relação ao glicolídeo. / According to World Health Organization (WHO), cancer is a leading cause of death worldwide. Prostate cancer is the second most common cancer in men. A method of radiotherapy which has been extensively used is brachytherapy, where radioactive seeds are placed inside the area requiring treatment. Iodine-125 seeds can be placed loose or stranded in bioabsorbable polymers. Stranded seeds show some advantages, since they reduce the rate of seed migration, an event that could affect the dosimetry of the prostate and cause unnecessary damage to healthy tissues or organs. For Iodine-125 stranded seeds, polyglactin 910 (poly(lactic-co-glycolic acid)) (PLGA), with a coverage of polyglactin 370 (Vicryl ®) is used. It was purposed in this dissertation, the study and development of the synthesis methodology for PLGA via ring-opening polymerization, as well as its characterization, with the objective of using the synthesized material to manufacture a material similar to RAPID Strand®. The results obtained show that it was possible to determine the optimal reaction parameters (time and temperature) for PLGA in 80/20 (lactide/glycolide) ratio. Using a temperature of 110 ° C and reaction time of 24h, a yield of 86% was obtained, and increasing the reaction time to 72 hours, the yield was higher than 90%. The molecular mass values obtained from the samples are still very low compared to those obtained by other authors in the literature (about 20%). Failures in the sealing of vials, leaving them vulnerable to moisture and oxygen, or lack of an efficient stirring system might be possible explanations for these results. A suitable chemical reactor could solve the problem. Regarding polymer characterization, all techniques used not only confirmed the expected structure of the polymer, but also showed the highest proportion of lactide units compared to to glycolide units.
62

Estudo dos parâmetros dosimétricos de sementes de Iodo-125 desenvolvidas pelo IPEN-CNEN/SP utilizadas em braquiterapia por simulação computacional pelo método de Monte Carlo / Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo Method

Tiago Batista de Oliveira 09 March 2016 (has links)
As expectativas da Organização Mundial de Saúde para o ano de 2030 são que o número de mortes por câncer seja de aproximadamente 13,2 milhões, evidenciando a elevada parcela desta doença no problema de saúde mundial. Com relação ao câncer de próstata, de acordo com o Instituto Nacional do Câncer, o número de casos diagnosticados no mundo em 2012 foi de aproximadamente 1,1 milhão, enquanto que no Brasil os dados indicam a incidência de 68 mil novos casos. O tratamento deste tipo de neoplasia pode ser realizado com cirurgia (prostatectomia) ou radioterapia. Dentre a radioterapia, podemos destacar a técnica de braquiterapia, a qual consiste na introdução (implante) de pequenas fontes radioativas (sementes) no interior da próstata, onde será entregue um valor elevado de dose no volume de tratamento e baixa dose nos tecidos ao redor. No Brasil, a classe médica estima uma demanda de aproximadamente 8000 sementes/mês, sendo o custo unitário de cada semente de pelo menos U$ 26,00. A Associação Americana de Físicos na Medicina publicou alguns documentos descrevendo quais parâmetros e análises devem ser realizadas para avaliações da distribuição de dose, como por exemplo, os parâmetros Constante de taxa de dose, Função radial e Função de anisotropia. Estes parâmetros podem ser obtidos através de medidas experimentais da distribuição de dose ou por simulações computacionais. Neste trabalho foram determinados os parâmetros dosimétricos da semente OncoSeed-6711 da empresa Oncura-GEHealthcare e da semente desenvolvida pelo Grupo de Dosimetria de Fontes de Braquiterapia do Centro de Tecnologia das Radiações (CTR IPEN-CNEN/SP) por simulação computacional da distribuição de dose utilizando o código MCNP5, baseado no Método de Monte Carlo. A semente 6711 foi modelada, assim como um sistema dosimétrico constituído por um objeto simulador cúbico de 30x30x30 cm3 preenchido com água. Os valores obtidos da semente 6711 foram comparados com alguns apresentados na literatura, onde o parâmetro Constante de taxa de dose apresentou erro relativo em relação ao valor publicado no TG- 43 de 0,1%, sendo que os outros parâmetros analisados também apresentaram boa concordância com os valores publicados na literatura. Deste modo, pode-se considerar que os parâmetros utilizados nas simulações (espectro, modelagem geométrica e avaliação de resultados) estão compatíveis com outros estudos, sendo estes parâmetros também utilizados nas simulações da semente do IPEN. Considerando as análises de incerteza estatística, os valores obtidos da semente do IPEN são semelhantes aos valores da semente 6711. / Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, anIPEN seed and the 30x30x30cm3phantom filled with water were modeled to simulatethe dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty.
63

Sintese e caracterizacao do hormonio tireotrofico humano recombinante (rec-hTSH) contendo uma sub unidade beta quimerica (rec-hTSHbeta-CTEP hCGbeta)

MURATA, YOKO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:11Z (GMT). No. of bitstreams: 1 06041.pdf: 4212913 bytes, checksum: fd1c8026a141fe44d8a936d7cfcd904d (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
64

Projeto e confecção de simuladores oftálmicos para aplicações clínicas

SANCHEZ, ANDREA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:32Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
65

Estudo e desenvolvimento de uma nova metodologia de produção de iodo-125 a partir de xenônio-124 pelo método de ativação neutrônica / Study and development of a new methodology for production of iodine-125 from xenon-124 through the method of neutron activation

COSTA, OSVALDO L. da 10 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T17:38:32Z No. of bitstreams: 0 / Made available in DSpace on 2015-12-10T17:38:32Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
66

Estudo dos parâmetros dosimétricos de sementes de Iodo-125 desenvolvidas pelo IPEN-CNEN/SP utilizadas em braquiterapia por simulação computacional pelo método de Monte Carlo / Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo Method

OLIVEIRA, TIAGO B. de 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T14:06:41Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T14:06:41Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
67

Desenvolvimento e construção de sistema automatizados para controle de qualidade na produção de sementes de iodo-125 / Development and construction of an automated system for quality control in the iodine-125 seeds production

MOURA, JOAO A. 01 July 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-07-01T11:08:37Z No. of bitstreams: 0 / Made available in DSpace on 2016-07-01T11:08:37Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
68

Sintese e caracterizacao do hormonio tireotrofico humano recombinante (rec-hTSH) contendo uma sub unidade beta quimerica (rec-hTSHbeta-CTEP hCGbeta)

MURATA, YOKO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:11Z (GMT). No. of bitstreams: 1 06041.pdf: 4212913 bytes, checksum: fd1c8026a141fe44d8a936d7cfcd904d (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
69

Projeto e confecção de simuladores oftálmicos para aplicações clínicas

SANCHEZ, ANDREA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:32Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta uma metodologia de cálculo para a obtenção de doses em estruturas do olho humano, como: esclera, coróide, retina, nervo óptico, corpo vítreo, câmara anterior, lente, além do tumor devido ao tratamento com placas oftálmicas. Construiu-se um modelo de olho humano com suas principais estruturas e dimensões fieis, além de um modelo matemático para uma placa de Co-60 e uma placa de sementes de I-125, levando-se em conta tamanho e disposição geométrica das fontes reais, com o código de Monte Carlo MCNP-4C. Esse modelo é capaz de calcular as distribuições de dose axiais e radiais para qualquer ponto do olho e para cada uma de suas estruturas. Construiu-se, também, um simulador de acrílico para o olho. Esse simulador é formado por uma esfera de acrílico fatiada em lâminas de 1 mm de espessura para simular as mesmas condições de simulação realizada pelos código MCNP-4C, fornecendo as doses axiais e radiais em filmes radiográficos. O simulador foi utilizado para validar os cálculos realizados com o código MCNP-4C. Os dados obtidos desse modelo matemático servirão para montar um banco de dados de doses para todas as estruturas do olho, posições e tamanhos de tumores e quaisquer placas oftálmicas utilizadas para tratamento. Esse banco de dados será a parte principal para a construção de um “software” nacional para cálculos de dose, que poderá fazer parte de um sistema de planejamento confiável para ser utilizado em radioterapia/braquiterapia. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
70

Estudo e desenvolvimento de uma nova metodologia de produção de iodo-125 a partir de xenônio-124 pelo método de ativação neutrônica / Study and development of a new methodology for production of iodine-125 from xenon-124 through the method of neutron activation

COSTA, OSVALDO L. da 10 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T17:38:32Z No. of bitstreams: 0 / Made available in DSpace on 2015-12-10T17:38:32Z (GMT). No. of bitstreams: 0 / Neste trabalho foi desenvolvida uma nova metodologia de produção de iodo-125, que resultou na primeira produção deste radionuclídeo no Brasil. Cápsulas de alumínio foram projetadas, fabricadas e avaliadas para que suportassem condições de pressão, temperatura e fluxo de nêutrons no reator nuclear IEA-R1 do IPEN sem a ocorrência de liberação de material radioativo. Foram projetados, desenvolvidos e fabricados sistemas de carregamento, descarregamento e recuperação dos gases para a manipulação do gás xenônio e do iodo. Foi desenvolvido um novo método de lavagem da cápsula, para dissolução do iodo-125 adsorvido nas paredes, por meio de imersão em banho ultrassônico. Foram irradiadas três cápsulas no reator nuclear IEA-R1, por um período de aproximadamente 60 h contínuas, a um fluxo de nêutrons de 5,5 x 1013 n cm-2 s-1. Foi produzido um total de 13,53 GBq (365,73 mCi) de iodo-125, e o único contaminante encontrado foi o radionuclídeo iodo-126. Na análise radioquímica, pelo método de cromatografia em papel ascendente, o iodo-125 em solução de NaOH apresentou percentual de iodeto acima de 98%, superior à exigência da farmacopeia americana para soluções de iodo radioativo que é de 95%. Para a análise radionuclídica foi desenvolvida uma fonte planar, a base de resina epoxídica, para a contagem do iodo-125 em detector de germânio de alta pureza. A correlação entre o iodo-125 e o iodo-126 produzido apresentou valores entre 0,5 e 0,7% após um período de decaimento de 10 d, grau de pureza suficiente para a utilização em técnicas de radioimunoensaio. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0441 seconds