Spelling suggestions: "subject:"oon cource"" "subject:"oon bource""
21 |
Understanding the plasma and improving extraction of the ISIS Penning H⁻ ions sourceLawrie, Scott January 2017 (has links)
A Penning-type surface-plasma negative hydrogen (H<sup>-</sup>) ion source has been delivering beam at the ISIS pulsed spallation neutron and muon facility for over thirty years. It is one of the most powerful and well-renowned H<sup>-</sup> sources in the world. Although long-term experience has allowed the source to be operated reliably and set up in a repeatable way, it is treated as something of a 'black box': the detailed plasma physics of why it works has always been unclear. A vacuum Vessel for Extraction and Source Plasma Analyses (VESPA) has been developed to understand the ISIS ion source plasma and improve the beam extracted from it. The VESPA ion source is operated in a completely new regime whereby the analysing sector dipole magnet housed inside a refrigerated 'cold box', presently used on ISIS, is replaced by an on-axis extraction system. The new extraction system incorporates a novel einzel lens with an elliptical aperture. This is the first demonstration of an elliptical einzel being used to focus an asymmetric H<sup>-</sup> ion beam. With the dipole magnet removed, the ion source has been shown to produce 85 mA of H<sup>-</sup> beam current at normal settings; of which 80 mA is transported through the new einzel lens system, with a normalised RMS emittance of 0.2 π mm mrad. Optical emission spectroscopy measurements have shown a plasma density of 10<sup>19</sup> m<sup>â3</sup>, an H<sub>2</sub> dissociation rate of 70%, an almost constant electron temperature of 3.5 eV and an atomic temperature which linearly increases above the electron temperature. In support of these principal measurements, rigorous particle tracking, electrostatic and thermal simulations were performed. In addition, a suite of new equipment was manufactured by the author. This includes a fast pressure gauge, a temperature controller, a high voltage einzel lens circuit, a fast beam chopper and a caesium detection system.
|
22 |
Analyse par ToF-SIMS de matériaux organiques pour les applications en électronique organique / ToF-SIMS analysis of organic multilayers for organic electronic applicationsTerlier, Tanguy 21 October 2015 (has links)
L'électronique organique a connu durant la dernière décennie un essor considérable. La production de dispositifs à base de matériaux organiques reste néanmoins freinée par différents verrous technologiques. La caractérisation de ce type de systèmes conduit à des besoins analytiques spécifiques et la spectrométrie de masse des ions secondaires à temps de vol (Timeof-Flight Secondary Ion Mass Spectrometry – ToF SIMS) est a priori très pertinente notamment grâce à l'utilisation d'un nouveau type de faisceau d'ions à base d'agrégats d'argon (Arn +). L'objectif principal de ce travail a donc été de comprendre l'interaction ions-matière d'un tel faisceau avec les matériaux organiques utilisés en électronique organique. Une étude fondamentale a d'abord été réalisée en comparant différents faisceaux d'ions de décapage (Cs+, C60 ++, Arn +) sur des échantillons organiques structurés (tels que les copolymères à blocs PS-b-PMMA) et il est apparu que, bien que la taille des agrégats et leur énergie ont peu d'effet sur l'endommagement observable sur les échantillons, les agrégats d'argon de grande taille induisent de la rugosité lors du profil en profondeur ToF SIMS, sans modification chimique, ce qui a été confirmé par des analyses complémentaires – AFM (Atomic Force Microscopy) et XPS (X-ray Photoelectron Spectroscopy) – et une modélisation géométrique. Ensuite, différents dispositifs du domaine de l'électronique organique ont été caractérisés. Ainsi, l'étude de l'auto structuration des copolymères à blocs PS-b-PMMA a permis d'évaluer l'influence du temps de recuit et de l'épaisseur de la couche. Par ailleurs, un protocole a été développé pour l'analyse d'empilements de couches inorganiques/organiques, notamment ceux des OLED. Il a ainsi été possible de caractériser par profil en profondeur ToF-SIMS les différents empilements d'un dispositif de l'électronique organique en conservant la détection d'un signal moléculaire et une haute résolution en profondeur de 2 nm. Parallèlement, nous avons identifié la dégradation chimique d'un matériau organique du multicouche constitutif de l'empilement et évalué la protection de celui-ci via des couches barrières. Plus précisément, les signatures de la réaction d'hydrolyse de la couche ont été identifiées ainsi que la teneur en humidité après encapsulation / During the last decade, organic electronics have developed rapidly. However, the production of organic electronic devices is still impeded because of various technological barriers. Such systems have specific analytical needs and time-of-flight secondary ion mass spectrometry (ToF-SIMS) is per se highly relevant, particularly when considering the use of a new type of ion source based on argon clusters (Arn +). The main objective of this work was therefore to understand the ion-matter interactions of such a cluster beam with the organic materials used in organic electronics. A fundamental study was carried out by comparing sputtering with three different ion beams (Cs+, C60 ++, Arn +) on organic structured samples (such as PS-b-PMMA block copolymers) and it transpired that although cluster size and energy has little effect on the observable damage to the sample, larger argon clusters induce more roughness during ToFSIMS depth profiling. This was confirmed by AFM (Atomic Force Microscopy) and XPS (Xray Photoelectron Spectroscopy) and a geometric model. Next, different devices in organic electronics were characterized by ToF-SIMS. The study of self-assembling PS-b-PMMA block copolymers made possible to evaluate the influence of the annealing duration and of the thickness of the layer. Furthermore, a protocol was developed to analyse stacks of inorganic/organic layers, in particular those contained in OLED devices. It was then possible to characterize the stacks of a complete organic light-emitting device whilst maintaining molecular signal and a high depth resolution of 2 nm. In parallel we identified the chemical degradation of an organic material in the stack and evaluated the efficiency of barrier layers designed to protect it. More precisely, specific signatures to the hydrolysis reaction of the layer as well as increase in moisture level after encapsulation were identified
|
23 |
High precision tests of QED : measurement of the alpha-particle and helion rms charge radius and the transition energies in highly-charged ions / Essais de haute précision du QED : mesures de la particule alpha et de la racine moyenne des rayons de charge de l'hélium et les énergies de transition en ions fortement chargésMachado, Jorge Felizardo Dias Cunha 26 February 2018 (has links)
Ce travail vise à contribuer à l’amélioration de notre connaissance de l’électrodynamique quantique des états liés, par des mesures de haute précision dans des états exotiques de la matière. Bien que notre connaissance de l’électrodynamique quantique des états liés et du problème relativiste à plusieurs corps aient fait des progrès importants ces dernières années, il reste des questions fondamentales dont la résolution nécessite d’augmenter le nombre et la précision des tests expérimentaux. La première partie de ce travail a été réalisée dans le cadre de l’expérience récente sur les ions muoniques d’hélium (μ4He+ et μ3He+) conduite par la collaboration CREMA. Cette expérience vise à fournir de nouvelles valeurs précises pour les rayons de charge moyens des noyaux des isotopes stables de l’hélium. Ces valeurs sont extraites de la mesure du déplacement de Lamb, c’est-à-dire, de la mesure de la différence d’énergie entre les États 2S − 2P. Une mesure des énergies de transition d’une précision d’au moins 50 ppm, permet de déterminer les rayons de charge des noyaux des isotopes d’hélium avec une incertitude de 0,03%, dix fois plus précise que les résultats précédents obtenus à partir de la diffusion d’électrons. La deuxième partie de ce travail a été de réaliser des mesures de haute précision de transitions de rayons X dans des ions fortement chargés, à l’aide d’un spectromètre à double cristal plan. Ces ions étaient produits dans le plasma d’une source d’ions de type ECRIS (electron-cyclotron resonance ion source). Le spectromètre utilisé est non seulement capable de fournir des mesures de haute précision, mais aussi des mesures sans référence à des énergies de transition théorique ou expérimentales. Quatre énergies de transition de n = 2 → n = 1 ont été mesurées pour des ions d’argon de trois états de charge différents, héliumoïde, lithiumoïde et berylliumoïde, avec une précision meilleure que 3 ppm. La largeur naturelle de chaque raie a également été obtenue expérimentalement. Les résultats trouvés sont en excellent accord avec les calculs théoriques les plus récents. / This work aims to provide insight on Bound-State Quantum-Electrodynamics (BSQED) by experimental fundamentals high-precision tests in exotic states of matter. Although BSQED and the relativistic many-body problem have been undergoing important progress, there are still some issues that require the increase of the number and accuracy of experimental fundamental tests. The first part of this work was done within the framework of the recent experiment in muonic helium ions (μ4He+ and μ3He+) by the CREMA collaboration. This experiment, aims to provide new accurate values for the root-mean-square (rms) charge radii of the helium isotopes nuclei that are extracted from the measurement of the Lamb Shift, i.e., the measurement of the energy difference between the 2S − 2P states. With the goal of measuring the transition energies with an accuracy of at least 50 ppm, the rms charge radii of the helium isotopes will be determined with an uncertainty of 0.03%, a factor of ten more precise than previous results obtained from electron scattering. The second part of this work aims the high-precision measurement of x-ray transitions in Highly-Charged Ions (HCI) using a Double-Crystal Spectrometer (DCS). These ions were produced in the plasma of an Electron-Cyclotron Resonance Ion Source (ECRIS). This kind of spectrometer is able not only to provide high-precision measurements but also reference-free measurements, without reference to any theoretical or experimental energy. Four transitions energies from n = 2 → n = 1 have been measured in an argon plasma in three different charge states, He-, Be- and Li-like, with an accuracy of better than 3 ppm. Besides the energies, the natural width of each transition has also been experimentally obtained. The obtained results are in excellent agreement with the most recent theoretical calculations.
|
24 |
Effect of shell closure N = 50 and N = 82 on the structure of very neutron-rich nuclei produced at ALTO. Measurements of neutron emission probabilities and half lives of nuclei at astrophysical r-processes pathTestov, Dmitry 17 January 2014 (has links) (PDF)
Nowadays we are all witnesses of a competition of facilities at different countries to study unknown regions of neutron rich nuclei. Much efforts are devoted to understand the role of neutron excess and its influence on nuclei in vicinity of closed neutron shells. One of the means to investigate nuclear structure is in beta-decay. Once a nucleus is proven to exist, its beta-decay properties, such as T1/2 and Pn (probability of beta-delayed neutron emission), which are relatively easy to measure, can provide the first hints on the nuclear structure. On the r-process site, "waiting points"(nuclei on closed neutron shells) has significant effects on the r-process dynamics and the abundance distribution. The actual side and the astrophysical conditions under which the nuclear synthesis takes place are still not certainly known - since r-process nuclei are difficult to produce and to study experimentally, input parameters for r-process calculations are mostly derived from theoretical models. As it has been seen lately, most of the theories have failed to reproduce newly measured data sets near shell closures. With new experimental data already (or shortly) available theoretical approaches can be adjusted. Since a beta-delayed neutron emission becomes strong if not dominating decaying channel for nuclei far stability, a proper neutron detector to study their properties is indispensable. To conduct the appropriate investigations, in the frame of the present thesis, in close collaboration with JINR (Dubna) a new detection system was constructed. It consists of 80 ³He-filled counters, 4π beta detector and a HPGe in order to measure simultaneously beta, gamma, neutron activity. The development of such a detection system system, currently installed at ALTO ISOL facility, was the first objective of the thesis. Then, during two experimental campaigns conducted to investigate beta decay properties of neutron rich nuclei in the neighborhood of N=50, N=82 the workability of the newly produced detection system was proven. In the vicinity of ⁷⁸Ni: half- lives and probability of beta-delayed neutron emission for ⁸º,⁸²,⁸³,⁸⁴Ga were measured. We were the first to observe the structure of ⁸¹,⁸² Ge via beta neutron gated gamma spectra. Thanks to the neutron detection channel the absolute intensities of beta decay were proposed for the first time. In the vicinity of ¹³²Sn the half lives of ¹²³Ag, ¹²⁴Ag, ¹²⁵Ag and ¹²⁷In, ¹²⁸In was measured. For the first time the beta delayed neutron emission was observed for ¹²⁶Cd, its Pn value also measured. Based on the data obtained we come to the conclusion that to figure out the relative contribution of allowed and forbidden decays more theoretical efforts should be done crossing the N=50 shell. Whereas in the vicinity of N=82 shell more experimental challenge are required.
|
25 |
Structure des noyaux de gallium, de germanium et d’arsenic riches en neutrons autour de N=50 et : développement d’une source d’ionisation laser à ALTO / Nuclear structure of neutron rich gallium, germanium and arsenic around N=50 and : development of a laser ion source at ALTOTastet, Benoît 13 May 2011 (has links)
Durant cette thèse, nous avons étudié les décroissances β des noyaux de gallium autour de N=50 et préparé une source d'ionisation laser à ALTO. Le besoin d’accéder à des régions de plus en plus exotiques pour la production de faisceaux radioactifs requiert l’élimination des contaminants polluant le faisceau d’intérêt. Afin de résoudre ce problème, une source d’ionisation laser a été développée à ALTO. Le cuivre a été choisi comme premier élément à ioniser pour ses intérêts physiques et pour comparer le fonctionnement de la source laser avec celles des autres installations de recherche. Des lasers ont été ainsi installés et optimisés pour ioniser sélectivement ce type d’atome produits pour les expériences. Ce montage laser nous a permis de tester l’ionisation du cuivre stable avec succès.L'étude de la région des noyaux riches en neutrons autour de N=50 est encore à approfondir. Les connaissances des noyaux de cette région sont clairsemées ce qui ne permet pas de clore les différents débats dont ils sont le sujet. Nous avons donc étudié les noyaux 79,80,82,83,84,85Ga produits à ALTO. Pour cela, un faisceau d’électrons (50MeV et 10µA) délivré par l’accélérateur linéaire est envoyé sur une cible de carbure d’uranium portée à 2000°C. Les électrons y émettent un rayonnement de freinage qui entraine la fission des noyaux d’uranium. Les produits de fission diffusent jusqu’à une source d'ionisation de surface qui est installée en sortie de cible pour ioniser les atomes de gallium et produire le faisceaux d’ions. Ce système nous permet d'étudier les décroissance β- et β--n des isotopes 79,80,82,83,84,85Ga.L’analyse de cette expérience a produit de nouveaux résultats sur les décroissances de 80Ga, 84Ga et 84Ge. Pour 80Ga, l’étude des données a confirmé l’existence d’un état isomérique et a permis de mesurer les durées de vie de l’état fondamental et de l’isomère. De plus, l’analyse de la décroissance de 84Ge a permis de confirmer deux états et de proposer un troisième pour 84As. Enfin la comparaison des résultats expérimentaux avec des calculs théoriques a confirmé l’assignation de spin-parité des premiers états 2+ et 4+ mais aussi du caractère triaxial de 84Ge proposés antérieurement à cette thèse. Le deuxième état 2+ de cet isotope a aussi été identifié. Pour les états de 84As, l’assignation des spins et des parités de quatre états a été proposée et interprétée en terme de mélange de configurations. / During this thesis, we have studied β decays of gallium’s nuclei around N=50 and prepared a laser ionization source at ALTO.The production of exotic isotopes has brought new beam production challenges. The one addressed here relates to the elimination of isobar contaminants that create background for experiments. To address this issue a laser ionization source has been developed at ALTO. Copper has been chosen to be the first element to be ionized for physical interests and to compare the results of the laser ionization source with the ones at others facilities. A laser setup has been installed and optimized in order to ionize selectively the atoms of copper produced for experiments. After the optimization, a test of ionization of stable-copper was performed. This test has shown us that the laser system is able to successfully ionize atoms of copper.The studies of the region of the neutron-rich nuclei around N=50 are still to complete. The knowledge of this region is low what does not allow to close off the debates which they are the subject. 79,80,82,83,84,85Ga has been produced using photo-nuclear reactions at the experimental area of the on-line PARRNe mass-separator operating with the ALTO facility. The fission fragments are produced at the interaction of the 50 MeV electron beam delivered by the ALTO linear accelerator with a thick target of uranium in a standard UCx form. The oven is connected to a W ionizer heated up to 2000°C that selectively ionizes alkalies but also elements with low ionization potentials such as Ga. The ions are accelerated through 30 kV and magnetically mass-separated before being implanted on a mylar tape close to the detection setup, so that this system allows us to study β- and β- -n decays of 79,80,82,83,84,85Ga.The data analysis have produced new results concerning the decays of 80Ga, 84Ga and 84Ge. For 80Ga, the existence of an isomeric state has been confirmed and two different half-lives were measured for the ground state and the isomer. Furthermore, the analysis of 84Ga decay confirmed two states and allowed us to propose an other state in the decay of 84Ge. Finally, the comparison between experimental results and theoretical calculations has confirmed the assignment of spin-parity of the first states 2+ and 4+ but also the triaxial property of 84Ge that has been proposed previously. The second state 2+ of this isotope has also been identified. For the states of 84As, the assignment of spins and parities of four states have been proposed and interpreted in terms of configuration mixing.
|
26 |
Probing the nuclear structure in the vicinity of 78Ni via beta decay spectroscopy of 84Ga / Etude de la structure nucléaire au voisinage de 78Ni par décroissance de 84GaKolos, Karolina 24 September 2012 (has links)
Grâce aux progrès de la production de faisceaux radioactifs au cours de deux dernières décennies, nous sommes à présent capables d'étudier les systèmes nucléaires très loin de la vallée de stabilité. La région de 78Ni reste encore inexplorée. Cette région, avec de très riches en neutrons 78Ni, noyau encore inconnu supposé doublement magique, est très intéressante en termes de structure nucléaire. En effet, les informations expérimentales obtenues sur l’espace de valence ouvert au dessus de 78Ni, nous permettront de construire des interactions effectives pour cette région. Nous avons étudié la désintégration de l’isotope 84Ga riche neutrons auprès de l'installation ALTO à l'IPN d'Orsay. Les fragments de fission ont été produites par photo-fission induite par l’interaction d’un faisceau d’électron de 50 MeV avec une cible épaisse de carbure d’uranium. Pour la première fois, ALTO a été utilisé dans ses conditions optimales, tant du point de vue de l’intensité du faisceau primaire (10 µA d’électrons à 50 MeV) que de la méthode d’ionisation. En effet, les atomes de gallium ont été sélectivement ionisés à l’aide d’une source d'ions laser. Grâce à cette nouvelle source l'ionisation du gallium était plus de dix fois supérieure à celui de la source à ionisation de surface utilisée précédemment par notre groupe. Les ions séparés par le séparateur de masse PARRNe ont été implantés sur une bande de mylar mobile, entourée de deux détecteurs germanium placés en géométrie rapprochés d’ un détecteur plastique pour le marquage des désintégrations bêta. Je présenterai les résultats de notre expérience obtenus pour les noyaux riches en neutrons 83,84Ge et 84As. Nous discuterons de leur structure et les comparerons aux résultats obtenus avec des calculs « modèle en couches » effectués avec la nouvelle interaction ni78 - jj4b construite dans le cadre de cette thèse. / Thanks to advances in production of radioactive nuclear beams in the last two decades, we are able to study nuclear systems very far from stability. The region of the nuclear landscape in the vicinity of 78Ni remains still unexplored. This region, with very neutron-rich 78Ni hypothetically considered as a doubly magic core, is interesting in terms of nuclear structures. The experimental information is equally important to guide the emerging shell-model effective interactions in this region. We have studied -decay of a neutron rich 84Ga isotope at the ALTO facility in IPN Orsay (France). The fission fragments were produced with photo-fission reaction induced by 50 MeV electron beam in a thick UCx target. For the first time the maximum electron driver beam intensity at ALTO - 10uA - was used. The gallium atoms were selectively ionized with a newly developed laser ion source. With this ion source the ionization of the gallium was more than ten times higher compared to the surface ion source previously used by our group. The ions were separated with the PARRNe mass separator and implanted on a movable mylar tape. Two germanium detectors in close geometry were used for the detection of gamma-rays and gamma-gamma coincidence measurement, and a plastic for beta tagging. We present the results of our experiment: the improved level schemes of the neutron-rich 83,84Ge and 84As isotopes. We discuss their structure and compare the experimental results with the shell model calculations made with the new effective interaction ni78-jj4b with 78Ni core, constructed in the framework of this thesis.
|
27 |
Vývoj atomárních a iontových svazkových zdrojů / Development of Atomic- and Ion Beam SourcesŠamořil, Tomáš January 2009 (has links)
The objective of this master thesis was to provide the optimization of an ion-atom beam source for the improvement of its properties. The improvement of the parameters increases the efficiency of the source during the deposition of gallium nitride ultrathin films (GaN) being important in microeletronics and optoelectronics. After optimization, the depositions of GaN ultrathin films on Si(111) 7x7 at lower temperatures (
|
28 |
Untersuchung der Erzeugung hochgeladener Ionen in einer Raumtemperatur-Elektronenstrahl-IonenfalleUllmann, Falk 31 December 2005 (has links)
Hochgeladene Ionen stellen einen extremen Zustand der Materie dar, wie sie vornehmlich in kosmischen Plasmen zu finden ist. Die labormäßige Erzeugung und (spektroskopische) Untersuchung hochgeladener Ionen liefert wichtige Daten und Erkenntnisse für die Astrophysik und Fusionsforschung. Aufgrund ihrer zum Teil exotischen Eigenschaften besitzen hochgeladene Ionen ein großes Potential für eine Vielzahl neuer Anwendungen. Die bisher weltweit einzige Elektronenstrahl-Ionenfalle, die hochgeladene Ionen bis hin zu vollständig ionisierten Ionen unter Raumtemperaturbedingungen erzeugen und bereitstellen kann, die Dresden EBIT, ist Gegenstand der vorgelegten Arbeit. Die Dresden EBIT zeichnet sich neben ihrer Kompaktheit und einer einfachen Bedienung durch ihre Langzeitstabilität aus. Sowohl über Röntgenspektren als auch über die Extraktion der Ionen aus der EBIT konnte für eine Reihe von Elementen der Nachweis der Erzeugung von vollständig ionisierten Ionen bis Z=28 erbracht werden. Für schwere Elemente können Ionenladungszustände bis hin zu neonähnlichen Ionen erzeugt werden. Entscheidenden Einfluss auf den erzielten mittleren Ladungszustand hat die Ioneneinschlusszeit. Die zeitliche Entwicklung der Ladungszustandsverteilung, wie sie im Zusammenspiel der verschiedenen atomaren Prozesse simuliert werden kann, ist sowohl an einer Reihe von röntgenspektroskopischen Messungen als auch anhand von Extraktionsspektren untersucht worden. Neben der Beladung der EBIT mit gasförmigen Elementen ist insbesondere die Beladung mit Metallen, d. h. mit einem möglichst breiten Spektrum an Elementen gefordert. Die Beladung mit leichtflüchtigen metallorganischen Verbindungen, die über das Gaseinlassventil eingebracht werden können, hat sich als erfolgreiche und preiswerte Alternative zu einer MEVVA-Quelle erwiesen. Die Beladung mit Metallionen ist am Beispiel verschiedener Untersuchungen gezeigt. Der monoenergetische Elektronenstrahl gestattet neben der Untersuchung von Anregungs- und Ionisationsprozessen insbesondere die der wichtigen Rekombinationsprozesse des Strahlenden Einfangs und der Dielektronischen Rekombination. Der Einsatz eines Kristalldiffraktionsspektrometers erlaubt trotz einer aufwendigen Kalibrierung und sehr langen Messzeiten die Auflösung einzelner Übergänge in hochgeladenen Ionen. Hauptanwendungsfeld der Dresden EBIT wird der Einsatz als Ionenquelle sein. Aus den Untersuchungen des extrahierten Gesamtionenstroms können die Bedingungen für einen möglichst großen Ionenstrom und einen optimalen Ionenstrahltransport abgeleitet werden. Eine optimale Ausnutzung der Eigenschaften hochgeladener Ionen erfordert die Separation der einzelnen Ladungszustände. Der Nachweis der sehr kleinen Ionenströme erfolgt über die kapazitive Messung in einem Faradaycup. Die Messung der Ladungszustandsverteilung in Abhängigkeit von den Parametern der EBIT gibt zusätzliche Aufschlüsse über die Eigenschaften der Ionenfalle.
|
29 |
A Homologous Study of Lifetimes and Oscillator Strengths of Ultraviolet Transitions in Singly Ionized Lead, Tin, and GermaniumHeidarian, Negar January 2017 (has links)
No description available.
|
30 |
Entwicklung und Charakterisierung einer Elektron-Zyklotron-Resonanz-Ionenquelle mit integriertem Sputtermagnetron für die Erzeugung intensiver Ströme einfach geladener AluminiumionenWeichsel, Tim 12 July 2016 (has links) (PDF)
Es wurde eine Elektron-Zyklotron-Resonanz-Ionenquelle mit einer Mikrowellenfrequenz von2,45 GHz für die Produktion intensiver Ströme einfach geladener Metallionen entwickelt. Deren Beladung mit Metalldampf erfolgt über ein integriertes zylindrisches Sputtermagnetron, welches speziell für diese Aufgabe entworfen wurde. Die entstandene MECRIS, engl. Magnetron Electron Cyclotron Resonance Ion Source, vereinigt die ECR-Ionenquellentechnologie mit der Magnetron-Sputtertechnologie auf bisher einzigartige Weise und verkörpert so ein neues Metallionen-Quellenkonzept. Unter Verwendung eines Al-Sputtertargets konnte die Funktionsfähigkeit der MECRIS an dem Beispiel der Al+-Ionenerzeugung erfolgreich demonstriert werden. Der extrahierbare Al+-Ionenstrom wurde über einen neuartigen, im Rahmen der Arbeit entwickelten, Hochstrom-Faraday-Cup gemessen.
Auf Basis numerischer Berechnungen wurde das Gesamtmagnetfeld so ausgelegt, dass die Permanentmagnete des Magnetrons und die Spulen der ECR-Quelle eine Minimum-B-Struktur erzeugen, welche einen effektiven Elektroneneinschluss nach dem magnetischen Spiegelprinzip ermöglicht. Gleichzeitig wird durch eine geschlossene ECR-Fläche, mit der magnetischen Resonanzflussdichte von 87,5 mT, eine optimale Heizung der Plasmaelektronen realisiert. Die mithilfe einer Doppel-Langmuir-Sonde gemessene Elektronentemperatur steigt in Richtung Quellenmitte an und beträgt maximal 11 eV. Geheizte Elektronen erlauben die effiziente Stoßionisation der Al-Atome, welche mit einer Rate von über 1E18 Al-Atome/s eingespeist werden und eine höchstmögliche Dichte von 2E10 1/cm³ aufweisen.
Die MECRIS erzeugt hauptsächlich einfach geladene Ionen des gesputterten Materials (Al+) und des Prozessgases (Ar+). Der Al+-Ionenextraktionsstrom ist über die Erhöhung der Prozessparameter Sputterleistung, Mikrowellenleistung, Spulenstrom und Extraktionsspannung um eine Größenordnung bis auf maximal 135 μA steigerbar, was einer Stromdichte von 270 μA/cm² über die Extraktionsfläche von rund 0,5 cm² entspricht. Dies steht im Einklang mit der Prozessparameterabhängigkeit der anhand der Sonde bestimmten Plasmadichte, welche einen größtmöglichen Wert von etwa 6E11 1/cm³ annimmt. Das Verhältnis von extrahiertem Al+- zu Ar+-Ionenstrom kann durch Optimierung der Prozessparameter von 0,3 auf maximal 2 angehoben werden.
Sondenmessungen des entsprechenden Ionendichteverhältnisses bestätigen diesen Sachverhalt. Um möglichst große Extraktionsströme und Al+/Ar+-Verhältnisse zu generieren, muss die ECR-Fläche demnach in dem Bereich der höchsten Al-Atomdichte in der Targetebene lokalisiert sein. Gegenüber dem alleinigen Magnetronplasma (ohne Mikrowelleneinspeisung) können mit dem MECRIS-Plasma um bis zu 140 % höhere Al+-Ionenströme produziert werden. Aus Sondenuntersuchungen geht hervor, dass dies eine Folge der um etwa eine Größenordnung gesteigerten Plasmadichte und der um rund 7 eV größeren Elektronentemperatur des MECRIS-Plasmas ist.
Das MECRIS-Plasma wurde außerdem mittels optischer Emissionsspektroskopie charakterisiert und durch ein globales sowie ein zweidimensionales Modell simuliert. Die gewonnenen Prozessparameterabhängigkeiten der Plasmadichte, Elektronentemperatur sowie Al+- und Ar+-Ionendichte stimmen mit den Sondenergebnissen überein. Teilweise treten jedoch Absolutwertunterschiede von bis zu zwei Größenordnungen auf.
Die Erhöhung der Sputterleistung und Extraktionsspannung über die derzeitigen Grenzen von 10 kW bzw. 30 kV sowie die Optimierung der Extraktionseinheit hinsichtlich minimaler Elektrodenblindströme bietet das Potential, den Al+-Ionenstrom bis in den mA-Bereich zu steigern. / An electron cyclotron resonance ion source working at a microwave frequency of 2.45 GHz has been developed in order to generate an intense current of singly charged metal ions. It is loaded with metal vapor by an integrated cylindrical sputter magnetron, which was especially designed for this purpose. The MECRIS (Magnetron Electron Cyclotron Resonance Ion Source) merges ECR ion source technology with sputter magnetron technology in a unique manner representing a new metal ion source concept. By using an Al sputter target, the efficiency of the MECRIS was demonstrated successfully for the example of Al+ ion production. The extractable ion current was measured by a newly developed high-current Faraday cup.
On the basis of numerical modeling, the total magnetic field was set in a way that the permanent magnets of the magnetron and the coils of the ECR source are forming a minimum-B-structure, providing an effective electron trap by the magnetic mirror principle.
Simultaneously, optimal electron heating is achieved by a closed ECR-surface at resonant magnetic flux density of 87.5 mT. Electron temperature increases towards the center of the source to a maximum of about 11 eV and was measured by a double Langmuir probe. Due to the heated electron population, efficient electron impact ionization of the Al atoms is accomplished. Al atoms are injected with a rate of more than 1E18 Al-atoms/s resulting in a maximum Al atom density of 2E10 1/cm³.
The MECRIS produces mainly singly charged ions of the sputtered material (Al+) and the process gas (Ar+). The Al+ ion extraction current is elevated by one order of magnitude to a maximum of 135 μA by increasing the process parameters sputter magnetron power, microwave power, coil current, and acceleration voltage. Related to the extraction area of about 0.5 cm², the highest possible Al+ ion current density is 270 μA/cm². A corresponding process parameter dependency was found for the plasma density showing a peak value of about 6E11 1/cm³, which was deduced from probe measurements. The ratio of the extracted Al+ ion current to the Ar+ ion current can be enhanced from 0.3 to a maximum of 2 by optimization of the process parameters. This was confirmed by probe investigations of the appropriate ion density ratio. In conclusion, the ECR-surface needs to be located in the area of the highest Al atom density in the target plane in order to improve the extraction current and Al+/Ar+ ratio.
The MECRIS plasma produces an Al+ ion current, which is up to 140 % higher compared to that of the sole sputter magnetron plasma (without microwave injection). As revealed by probe measurements, this effect is due to the higher plasma density and electron temperature of the MECRIS plasma, leading to a difference of one order of magnitude and 7 eV, respectively.
Additionally, the MECRIS plasma has been characterized by optical emission spectroscopy and simulated by a global and a two-dimensional model. Retrieved process parameter dependencies of plasma density, electron temperature, Al+ ion density, and Ar+ ion density coincide with probe findings. Although a discrepancy of the absolute values of partly up to two orders of magnitude is evident.
Potentially, the Al+ ion current can be enhanced to the mA-region by optimizing the ion extraction system for minimal idle electrode currents and by rising sputter magnetron power as well as acceleration voltage above the actual limits of 10 kW and 30 kV, respectively.
|
Page generated in 0.0555 seconds