• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia de la distribución de amortiguadores de masa sintonizada ubicados en el último piso de una edificación de concreto armado de 5 niveles para la reducción de los efectos torsionales ante respuestas sísmicas mediante un análisis estructural en Lima, Perú

Barja Rosas, Xiomara Mariela, Sotomayor Cerron, Aldahir Edgar 27 October 2021 (has links)
En este trabajo se analizará el control de la respuesta sísmica de una edificación asimétrica de 5 pisos mediante la incorporación de Amortiguadores de Masa Sintonizada (AMS) evaluando distintas distribuciones de porcentaje de masa del dispositivo para obtener una óptima ubicación en la última planta con el objeto de reducir los efectos torsionales producto de las irregularidades de planta. Para el desarrollo se designaron diversas variables para caracterizar el comportamiento de cada modelo. Estudios anteriores optaban por considerar independientemente cada variable y globalizaban la respuesta de estas a el resto de las variables. A raíz de esto, se decide analizar paralelamente y comparar en cada modelo estructural hasta obtener una óptima distribución. / A viable option to reduce seismic vibrations in structures is the use of passive control devices, within which are the Tuned Mass Dampers (AMS). In an asymmetric construction a greater flexional and torsional vibration is produced, this phenomenon leads to an increase in the forces present in the sections and an eventual collapse of the structure. In this way, the implementation of the Tuned Mass Damper in an asymmetric building, allows to dissipate the energy product of horizontal movements such as the earthquake, besides attenuating the torsional effects due to the asymmetry. In this research thesis the control of the seismic response of an asymmetric 5-story building, structured on the basis of porticos and reinforced concrete walls, will be analyzed, by incorporating Tuned Mass Dampers evaluating different distributions to obtain the optimal location and distribution in the last floor in order to control the torsional effects product of plant irregularities. / Tesis
2

Desempeño sísmico de una edificación de concreto armado dual mediante el análisis no lineal en el tiempo ubicado en el distrito de Lince, departamento de Lima-Perú / Seismic performance of a reinforced concrete building through nonlinear análisis over time

Ojeda Barrionuevo, Jean Paul, López Pizarro, Juan Américo 12 February 2021 (has links)
El tema de esta investigación aborda el desempeño sismorresistente de un edificio en Lima aplicando el análisis dinámico no lineal “Tiempo historia”. Por ello, la hipótesis plantea que el desempeño sísmico de un edificio destinado a vivienda en la ciudad de Lima debido a un sismo moderado y severo, cumple con lo indicado en la Norma Peruana Sismorresistente E-030 respecto a sus objetivos del no daño estructural y el no colapso respectivamente, si los puntos de desempeño obtenidos al comparar la curva de Capacidad con la curva de Demanda de la Norma E-030 se encuentran dentro del rango de desempeño establecido según el código de la Agencia Federal para el Manejo de Emergencias (FEMA). Consecuentemente, la investigación está dividida en 5 capítulos. En el primero, se presenta la descripción de la estructura a analizar, que abarca sus características arquitectónicas y estructurales. En el segundo, se expone una serie de conceptos fundamentales plasmados en el marco teórico, para entender el desempeño sísmico y todo lo relacionado con este análisis. En el tercero y cuarto, se realiza la evaluación del desempeño sismorresistente aplicando el Análisis Dinámico No lineal Tiempo Historia. Finalmente, se verificará si el desempeño sismorresistente de un edificio de albañilería confinada en la ciudad de Lima cumple o no con los objetivos de la Norma Peruana Sismorresistente E-030 2019. / The subject of this research deals with the seismic performance of a building in Lima applying the non-linear dynamic analysis "Time History". Therefore, the hypothesis states that the seismic performance of a building intended for housing in the city of Lima due to a moderate and severe earthquake, complies with the provisions of the Peruvian Seismic E-030 Standard regarding its objectives of structural and non-structural damage. the non-collapse respectively, if the performance points obtained when comparing the Capacity curve with the Demand curve of the E-030 Standard are within the performance range established according to the code of the Federal Emergency Management Agency (FEMA). Consequently, the investigation is divided into 5 chapters. In the first one, the description of the structure to be analyzed is presented, which covers its architectural and structural characteristics. In the second, a series of fundamental concepts embodied in the theoretical framework is exposed to understand the seismic performance and everything related to this analysis. In the third and fourth, the evaluation of the seismic performance is performed applying the dynamic nonlinear analysis Time History. Finally, it will be verified if the seismic performance of a reinforced concrete building in the city of Lima complies or not with the objectives of the Peruvian Seismic Standard E-030 2019. / Tesis
3

Análisis de la implementación de disipadores fluido-viscosos en el comportamiento torsional de una edificación de 5 niveles localizada en Lima / Analysis of the implementation of viscous fluid dissipators in the torsional behavior of a 5-level building located in Lima

Orihuela Allende, Giuliana Mercedes, Velazque Olarte, Cristopher Guy 14 April 2021 (has links)
El presente trabajo, consiste en la implementación de estos disipadores fluido-viscosos en una edificación con predominación de muros estructurales de 5 niveles que presenta un comportamiento torsional. El diseño de estos disipadores, parten con el objetivo de diseño de daño moderado y bajo un sismo de 475 años de periodo de retorno, es decir que la deriva objetivo necesario para el diseño es 0.58%. Se analiza bajo la colocación en diagonal para amortiguadores lineales y no lineales. La colocación se hace de manera uniforme, y de manera que compense el movimiento torsional. Se colocaron un total de 40 disipadores en todo el edificio. Entre los principales resultados, la fuerza fuerzas en los disipadores fueron en un orden de 213 ton-f y comportamiento torsional debido a zonas frágiles de la estructura fueran reducidas en 80%. La implementación de los disipadores fluido-viscosos permiten reducir la deriva en 60% y todas las derivas se mantienen por debajo de 0.58%, en teoría. En un futuro, en el Perú, será necesario implementar una normativa para el diseño y el aporte de amortiguamiento en el edificio. / The present work consists of the implementation of these fluid-viscous dissipators in a building with a predominance of structural walls, of 5 levels that presents a torsional behavior, as well as fails to comply with the permissible drift limit established by Norma Técnica E.030. The design of these dissipators starts with the design objective of moderate damage and under an earthquake of 475 years of return period, whose corresponding objective drift assumes a value of 0.58%. It is discussed under diagonal placement for linear and nonlinear dampers. The placement is done uniformly, and in a way that compensates for torsional movement. A total of 40 heatsinks were placed throughout the building, 8 per floor. Among the main results, the forces in the dissipators were in the order of 200 ton-f and torsional behavior due to flexible areas of the structure were reduced by 80%. The implementation of fluid-viscous heatsinks allows the drift to be reduced by 60%, and all drifts are kept below 0.58%, that is, both linear and non-linear devices meet the target drift, even though the latter have a higher drift, given their lower C, therefore, lower force, less drift control, even so, they are efficient, both structurally and economically, given their lower strength. In the future, in Peru, it will be necessary to implement a regulation for the design and the cushioning contribution in the building. / Trabajo de investigación

Page generated in 0.0294 seconds