• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Multi-criteria decision aiding model for the evaluation of agricultural countermeasures after an accidental release of radionuclides to the environment

Turcanu, Catrinel 31 October 2007 (has links)
Multi-criteria decision aid has emerged from the operational research field as the answer given to a couple of important questions encountered in complex decisions problems. Firstly, as decision aiding tools, such methods do not replace the decision maker with a mathematical model, but support him to construct his solution by describing and evaluating his options. Secondly, instead of using a unique criterion capturing all aspects of the problem, in the multi-criteria decision aid methods one seeks to build multiple criteria, representing several points of view. <p>This work explores the application of multi-criteria decision aid methods for optimising food chain countermeasure strategies after a radioactive release to the environment. <p>The core of the thesis is dedicated to formulating general lines for the development of a multi-criteria decision aid model. This includes the definition of potential actions, construction of evaluation criteria and preference modelling and is essentially based on the results of a stakeholders’ process. The work is centred on the management of contaminated milk in order to provide a concrete focus and because of its importance as an ingestion pathway in short term after an accident.<p>Among other issues, the public acceptance of milk countermeasures as a key evaluation criterion is analysed in detail. A comparison of acceptance based on stochastic dominance is proposed and, based on that, a countermeasures’ acceptance ranking is deduced.<p>In order to assess “global preferences” taking into account all the evaluation criteria, an ordinal method is chosen. This method allows expressing the relative importance of criteria in a qualitative way instead of using, for instance, numerical weights. Some algorithms that can be used for robustness analysis are also proposed. This type of analysis is an alternative to sensitivity analysis in what concerns data uncertainty and imprecision and seeks to determine how and if a model result or conclusion obtained for a specific instance of a model’s parameters holds over the entire domain of acceptable values for these parameters.<p>The integrated multi-criteria decision aid approach proposed makes use of outranking and interactive methodologies and is implemented and tested through a number of case studies and prototype tools. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
12

Molybdophosphate d'ammonium immobilisé sur silice mésoporeuse pour l'adsorption sélective du radiocésium

Schneider, Solange 19 April 2018 (has links)
Les sources de radiocésium-137 (137Cs) sont utilisées commercialement dans les domaines médicaux et industriels. Il existe plusieurs méthodes, telle la spectroscopie-γ, permettant de détecter de faibles concentrations de 137Cs. Cependant, l’analyse du ratio 135Cs/137Cs, qui permet de caractériser la source, ne peut être obtenue que par spectrométrie de masse, et seulement si l’élément a été préalablement séparé chimiquement, et ce, pour éviter les interférences isobariques. Ce mémoire porte sur la séparation du Cs+ par l’utilisation d’adsorbants à base de molybdophosphate d’ammonium (AMP), sel connu pour être sélectif au Cs+, supportés sur silice mésoporeuse (SBA-15). Les silices mésoporeuses permettent d’augmenter la surface de contact avec l’échantillon et de stabiliser l’échangeur de cations pour des perspectives de régénération. Des analyses ont été faites quant aux caractéristiques chimiques des matériaux par plasma à couplage inductif-spectrométrie de masse, diffraction des rayons X, thermogravimétrie et spectroscopie de photoélectrons induits par rayons X. Les caractéristiques physiques des matériaux ont quant à elles été déterminées par microscopie électronique et par physisorption d’azote à -196 °C. Finalement, les capacités des matériaux ont été évaluées par analyse élémentaire par plasma à couplage inductif-spectrométrie de masse. / Radiocesium (137Cs) sources are commercially used in medical and industrial domains. Several methods, including γ-spectroscopy, can detect low concentrations of 137Cs. However, only mass spectroscopy can achieve the determination of the 135Cs/137Cs, which is important to characterize the radiosource. Radiocesium having several isobaric interferences, it is hence necessary to chemically separate the cesium from its matrix. Cesium separation has been studied by using ammonium molybdophosphate (AMP) based adsorbents, this salt being known to be selective to Cs+. These sorbents are supported on mesoporous silicas (SBA-15), which allows to enhance the specific surface of the material and thus stabilizes the cationic exchanger, allowing regeneration. Materials have been analysed by inorganic mass spectrometry, X-ray diffration, thermogravimetric analysis and by X-ray photoelectron spectroscopy to determine their chemicals characteristics. Physical characteristics have been determined by electronic microscopy and by nitrogen physisorption at -196 °C. Extraction capacities have also been studied by inorganic mass spectrometry.
13

Évaluation des teneurs de radionucléides dans le milieu aqueux en aval de la centrale nucléaire Gentilly-2

Latouche, Gaétan 13 April 2018 (has links)
Les opérations courantes de la centrale nucléaire Gentilly-2 nécessitent l'utilisation d'une grande quantité d'eau pour le refroidissement. En effet, les activités de la centrale nucléaire utilisent environ trente mètres cubes d'eau brute du fleuve par seconde. De plus, il faut considérer le caloporteur et le modérateur. Ces deux systèmes utilisent de l'eau lourde (D₂O). La conception de ces systèmes prévoit des systèmes de récupération en cas de fuites qui peuvent provenir par exemple des garnitures des pompes. Les deux systèmes ont aussi des systèmes de purification pour maintenir le caloporteur et le modérateur à des niveaux très bas d'impuretés et limiter ainsi la formation de produits d'activation. Ces systèmes de purification ont des filtres pour les particules solides et des résines cationiques et anioniques pour éliminer les impuretés solubles. Une fois saturées, ces résines sont dédeutérisées et envoyées dans des fosses d'entreposage avec une certaine quantité d'eau légère (pour faciliter la manipulation des résines). Le surplus est envoyé périodiquement dans les réservoirs de rejets radioactifs qui sont vidangés au fleuve et mélangés aux trente mètres cubes d'eau rejetée au canal de rejet de la centrale nucléaire. Cette étude s'intéresse au devenir des contaminants à partir de leurs rejets dans le fleuve Saint-Laurent et plus particulièrement aux trois radionucléides les plus rejetés à l'effluent liquide par la centrale nucléaire Gentilly 2 c'est-à-dire le carbone-14, le tritium et le cobalt-60. Des modèles informatiques ont été choisis pour étudier tout le phénomène de dispersion, de dilution, de sédimentation et de concentration dans les espèces de ces trois principaux contaminants rejetés dans le fleuve Saint-Laurent. Ces modèles permettent de traiter un grand nombre de contaminants différents. De plus, à partir des résultats obtenus, il a été possible de calculer les doses aux organismes qui se situent dans le panache de rejet de la centrale. Ces calculs de doses peuvent êtres ensuite extrapolés pour un grand nombre de rejets différents. En parallèle avec ce projet, plusieurs échantillons ont été recueillis dans la région sur une espèce implantée artificiellement dans la région, l'Eliptio Complanata, pour valider les valeurs obtenues à l'aide des modèles.

Page generated in 0.05 seconds