• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 1
  • Tagged with
  • 28
  • 14
  • 14
  • 10
  • 10
  • 10
  • 10
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Tensões residuais induzidas por shot-peening e durabilidade de molas em lâmina. / Residual stresses induced by shot-peening and fadigue life of leaf springs.

Bruno Geoffroy Scuracchio 26 November 2012 (has links)
O aumento da vida em fadiga em peças submetidas a esforços cíclicos devido à aplicação de processos de tratamento mecânico superficial já é bastante conhecido, tanto no meio industrial quanto no meio acadêmico. Para molas, o processo de shot-peening se torna etapa essencial no processo de fabricação, porém um estudo sistemático do efeito do shot-peening na vida em fadiga se faz necessário. O objetivo deste trabalho é aprofundar o conhecimento nos processos de jateamento superficial do tipo shot-peening para molas em lâminas de veículos, através da análise de tensões residuais por difração de raios-x e ensaios de fadiga em uma série de amostras que sofreram dez diferentes receitas de processos de jateamento. Dos dez diferentes processos, o de jateamento com granalha esférica fundida de aço com 1,0mm de diâmetro seguido de um segundo jateamento com granalha esférica fundida de aço de 0,3mm de diâmetro levou a uma maior vida em fadiga das amostras. A análise por difração de raios-x comprovou que a importância das tensões residuais de compressão se dá até a uma profundidade de 0,05mm, influenciando diretamente no modo de nucleação de trincas de fadiga. Acima desta profundidade, as tensões residuais induzidas por shot-peening não têm influência no modo de propagação destas trincas, e por consequência na vida em fadiga das peças. Correlações entre os resultados e a alta dureza e diminuída ductilidade do material utilizado são discutidas. / The improvement of fatigue life in parts subjected to cyclic stresses by application of mechanical surface treatment processes is already well known, both in the industry and in the academy. Dealing with automotive springs, the shot peening process becomes an essential step in manufacturing these parts. In the case of leaf springs, however, a systematic investigation of the effect of shot peening on fatigue life is still required. The aim of this work is to improve the knowledge of shot peening on leaf springs for vehicles, through the analysis of residual stresses by x-ray diffraction and fatigue tests on a series of samples that were subjected to ten different peening schedules. Among the investigated processes, the usage of 1.0 mm diameter cast steel shot followed by a second peening with 0.3 mm diameter cast steel shot leads to better performance, regarding fatigue life. X-ray diffraction analysis shows that this improved performance may be attributed to residual compressive stress maintained until a depth of 0.05 mm below the surface, which directly influences the fatigue crack nucleation. Residual stresses induced by shot-peening in larger depths, have no influence on sample fatigue life, showing that crack propagation is not affected by the induced residual stresses. Consequently, the durability of parts is improved by shot-peening exclusively due to this influence on crack nucleation at samples surface. Correlations with the increased hardness and decreased ductility of the employed material are discussed.
22

Influência de parâmetros de processo no crescimento de trincas curtas por fadiga em camada cementada do aço DIN 20MnCr5. / The influence of manufacturing process parameters on short fatigue crack growth in a carburized case.

Mauricio Carvalho da Cunha 09 June 2000 (has links)
Os tratamentos de cementação, têmpera, revenimento e jateamento por granalhas são muito utilizados na produção seriada de peças da indústria automobilística, como engrenagens e eixos. Variações destes processos podem influenciar a vida em fadiga por flexão dos componentes descritos. O objetivo deste trabalho foi estudar a influência de variações no tempo de jateamento por granalhas, variações na temperatura de revenimento e de diferentes profundidades de oxidação intergranular, no crescimento de trincas curtas por fadiga na camada cementada do aço DIN 20MnCr5. Para isso foram feitos ensaios de fadiga por flexão em quatro pontos, utilizando corpos de prova de seção retangular e sem entalhe. Para o acompanhamento do crescimento de trincas curtas foi utilizado o método de réplicas de acetato. Foram estudados seis níveis de jateamento, quatro níveis de revenimento e dois níveis de oxidação intergranular. Como resultados principais, foram obtidas curvas de comprimento de trinca por número de ciclos e taxa de crescimento de trinca por tamanho médio da trinca. Amostras jateadas entre trinta minutos e uma hora, revenidas à 160&#176C e com oxidação intergranular por volta de dez mícrons, apresentaram os melhores resultados em relação à vida em fadiga. / Carburizing, quenching, tempering and shot peening treatments are often used in mass production of automotive parts, such as gears and shafts. Changes in these treatments can influence the bending fatigue life of these parts. The purpose of this study was to measure the influence of different shot peening times, different tempering temperature and different internal oxidation depths, on the short fatigue crack growth in case carburized DIN 20MnCr5 steel. Four-point-bend fatigue tests were carried out in rectangular section specimens without notch. The surface short crack growth was monitored by means of acetate replication technique. Six levels of shot peening, four levels of tempering temperatures and two levels of internal oxidation were studied in this work. Crack length versus number of cycles and crack growth rate versus mean crack length were obtained as principal results. Shot peening from 30 minutes to one hour, tempering at 160#176C and a lO~m depth of internal oxidation showed the best results in fatigue life.
23

Avaliação da resistência ao cisalhamento da zircônia após diferentes tratamentos de superfície / Evaluation of shear bond strength of zirconia after different surface treatments

Livia Aguiar Santos 06 May 2011 (has links)
Cerâmicas de alto conteúdo cristalino, como a zircônia policristalina tetragonal estabilizada por ítrio (Y-TZP), apresentam ótimas propriedades mecânicas quando comparadas às cerâmicas convencionais, sendo cada vez mais empregadas como materiais restauradores indiretos. Entretanto, seu sucesso também depende da formação de uma união confiável com os agentes de cimentação. Porém, o aumento do conteúdo cristalino modificou as características de adesão entre cerâmica e cimento resinoso, não existindo um protocolo de cimentação bem estabelecido na literatura. Portanto, este estudo teve como objetivo avaliar o efeito na resistência ao cisalhamento de diferentes tratamentos de superfície sobre a zircônia, utilizando dois cimentos resinosos, assim como avaliar as possíveis diferenças no modo das fraturas. Cento e vinte amostras retangulares de zircônia foram incluídas em resina acrílica e divididas em 12 grupos (n=10), de acordo com os tratamentos de superfície e os cimentos (Panavia F e Rely X U100). Para cada cimento, os grupos experimentais foram formados da seguinte maneira: RU e Pa - controle (sem nenhum tratamento de superfície); ApRU e ApPa (aplicação do Alloy Primer); MzRU e MzPa (aplicação do Metal/Zircônia Primer); JatRU e JatPa (jateamento com partículas de óxido de alumínio de 50µm); JatApRU e JatApPa (jateamento e aplicação de Alloy Primer); JatMzRU e JatMzPa (jateamento e aplicação do Metal/Zircônia Primer). Os corpos de prova foram armazenados em água destilada à temperatura de 37°C por 24 horas, antes do teste de cisalhamento em uma máquina de ensaio universal (EMIC). Os valores foram submetidos primeiro a ANOVA a um critério (resistência ao cisalhamento) e teste de Tukey (p 0,05), independente do tratamento e do sistema de cimentação. Em seguida, ANOVA a dois critérios (tratamento de superfície e sistema de cimentação) e o teste de Tukey foram aplicados para observar com maior precisão a interação entre cimento e tratamento de superfície. Os resultados apresentados foram: RU - 11,71a, ApRU - 21,49b,e, MzRU - 30,38c,d, JatRU - 34,40c, JatApRU - 30,66c,d, JatMzRU - 38,06c, Pa - 11,35a, ApPa - 11,98a, MzPa - 11,46a, JatPa - 33,50c, JatApPa - 23,14b,d,e, JatMzPa - 18,66a,e. Por meio dos resultados obtidos foi possível concluir que a resistência ao cisalhamento pode ser melhorada ao utilizar o jateamento com partículas de óxido de alumínio e, para o RelyX U100, somente a aplicação do Metal/Zircônia Primer resultou em valores de adesão comparavéis ao tratamento mecânico. O cimento RelyX U100 apresentou maior resistência de união quando comparado ao Panavia F. / High crystalline content ceramics, such as yttria stabilized tetragonal zirconia polycrystal (Y-TZP), show great mechanical properties when compared to conventional ceramics, being increasingly used as indirect restorative materials. However, its success also depends on the reliable bond formation with luting agents. Though, the high crystalline content modified the adhesiveness between ceramic and resin cement although there isnt any cementing protocol established in literature. Therefore, the purpose of this study was to evaluate the effect of the shear bond strength after different surface treatments on the zirconia, using two resin cements and to evaluate possible differences in fracture modes. One hundred and twenty rectangular samples of zirconia were embedded in acrylic resin and divided into 12 groups (n=10) according to the surface treatments and the cements (Panavia F and RelyX U100). For each cement, the experimental groups were formed as follow: RU and Pa - control (no surface treatment); ApRU and ApPa (application of Alloy Primer); MzRU e MzPa (application of Metal/Zirconia Primer); JatRU and JatPa (air abrasion with 50µm Al2O3 particles); JatApRU and JatApPa (air abrasion and application of Alloy Primer); JatMzRU and JatMzPa (air abrasion and application of Metal/Zirconia Primer). The specimens were stored in distilled water at 37°C for 24 hours prior to the shear bond strength test in a universal testing machine (EMIC). The data were first analyzed by one-way ANOVA (shear bond strength) and Tukey test (p<0.05), regardless of the treatment and the luting system. Then two-way ANOVA (surface treatment and luting system) and the Tukey test were applied in order to observe more accurately the interaction between cement and surface treatments.The results presented were: RU 11.71a, ApRU 21.49b,e, MzRU 30.38c,d, JatRU 34.40c, JatApRU 30.66c,d, JatMzRU 38.06c, Pa 11.35a, ApPa 11.98a, MzPa 11.46a, JatPa 33.50c, JatApPa 23.14b,d,e, JatMzPa 18.66a,e. Based on the results obtained, it was possible to conclude that the shear bond strength can be improved when air abrasion was used with aluminum-oxide particles and for the RelyX U100, only the application of Metal / Zirconia Primer resulted in adhesion values comparable to mechanical treatment. The RelyX U100 cement showed higher bond strength when compared to Panavia F.
24

OBTENÇÃO E AVALIAÇÃO DO COMPORTAMENTO À FADIGA DE COMPÓSITOS DE MATRIZ DE ALUMÍNIO SUBMETIDOS A DIFERENTES TRATAMENTOS SUPERFICIAIS MECÂNICOS / OBTENTION AND EVALUATION OF THE FATIGUE BEHAVIOUR OF ALUMINIUM MATRIX COMPOSITES SUBJECT TO DIFFERENT MECHANICAL SURFACE TREATMENTS

Edson Souza de Jesus Filho 27 March 2000 (has links)
O objetivo deste trabalho foi a avaliação do comportamento à fadiga de materiais compósitos de matriz metálica (CMM) obtidos pela rota da metalurgia do pó, tendo como variáveis a fração volumétrica de reforços e o tipo de tratamento superficial mecânico utilizado. Foram obtidos materiais compósitos com matriz de alumínio AA 1100 reforçados com partículas de carboneto de silício (SiC) nas frações volumétricas de 5, 10 e 15%. Uma quantidade de material de controle, constituído unicamente pelo material da matriz também foi produzida para fins de comparação. Os materiais obtidos foram caracterizados física, mecânica e microestruturalmente. Os resultados mostraram, de maneira geral, uma distribuição homogênea das partículas de reforço e melhoria do limite de resistência dos compósitos com relação ao material de controle. Entretanto, alguns defeitos como porosidades e veios de alumínio puro foram detectados esporadicamente. Em outra etapa, foram realizados ensaios de fadiga do tipo axial nos materiais em modo tensão-tensão, com razão de tensões R = 0,1 e frequência de 15 Hz. Os tipos de tratamentos superficiais utilizados na confecção dos corpos de prova de fadiga foram: usinagem e jateamento. As variáveis de usinagem foram: taxa de avanço e tipo de ferramenta. Os materiais jateados não apresentaram melhorias significativas de vida à fadiga com relação ao material de controle. Os usinados grosseiramente apresentaram a pior vida em fadiga e as marcas de usinagem, nestes casos, funcionaram como fortes concentradores de tensão. Os reforçados com 5% de SiC, diferentemente daqueles reforçados com 10 e 15%, apresentaram vida à fadiga inferior à do material de controle, ou por causa do menor limite de escoamento ou devido à menor fração volumétrica de reforços. Os materiais usinados com metal duro (MD) não apresentaram diferenças de vida à fadiga com relação aos usinados com PCD, provavelmente devido à classe do metal duro utilizado. Os materiais reforçados com 5% de SiC e jateados apresentaram resultados de fadiga com os maiores desvios padrões. Os materiais reforçados com 5% de SiC apresentaram as menores sensibilidades à fadiga com a variação da carga. / The objective of this work was the evaluation of the fatigue behaviour of aluminium metal matrix composites (MMC) obtained by powder metallurgy. The testing variables were the volumetric fraction of reinforcements and the type of mechanical surface treatment used. Initially, the composite materials were obtained from aluminium AA 1100 matrix, reinforced with silicon carbide (SiC) particles in the volumetric fraction of 5, 10 and 15%. An amount of control material (unreinforced) was produced for comparison purposes. The obtained materials were physically, mechanically and microstructurally characterised. The results showed a homogeneous distribution of the reinforcement particles and an improvement of the ultimate tensile strength of the composites with relation to the control material. However, some defects such as porosity and streaks of pure aluminium were detected. In a second stage, the fatigue tests of the composites were accomplished. The types of surface treatments used in the fabrication of the fatigue test specimens were machining and shot peening. For machining the variables were feed rate and tool type. The shot peened materials did not present a significant fatigue life improvement when compared to the control material. The coarse machined materials presented the worst fatigue life and the machining marks worked as strong stress concentrators. The material reinforced with 5% of SiC, differently of those reinforced with 10 and 15% showed inferior fatigue life when compared to the control material, probably because of a lower yielding strength, or lower reinforcement volumetric fraction. The material machined with hard metal (MD) did not present differences of fatigue life with relation to the machined with PCD, probably due to the class of the hard metal used. The material reinforced with 5% of SiC and shot peened, presented fatigue results with the largest standard deviations. The materials reinforced with 5% of SiC presented the smallest fatigue sensibility with the load variation.
25

Comparação de molas de suspensão temperadas e revenidas enroladas a quente e a frio

Hattori, Carolina Sayuri 10 February 2012 (has links)
Made available in DSpace on 2016-03-15T19:36:36Z (GMT). No. of bitstreams: 1 Carolina Sayuri Hattori.pdf: 7042218 bytes, checksum: 0bc43ea853ac897f08d717277994e267 (MD5) Previous issue date: 2012-02-10 / IPEN - Instituto de Pesquisas Energéticas e Nucleares / The fatigue and toughness resistance are properties that exerts a strong influence on the spring suspension performance in the vehicles. The choice of SAE 9254 steel is due to the wide utilization in the springs fabrication and to have fatigue and toughness properties. The manufacture of SAE 9254 spring steel has been made by hot rolling process and submitted to heat treatment of quenching and tempering by conventional process or by cold process with induction heat treatment. Therefore, it is important to study the performance of this steel in these two processes. This study investigated the effect of the two production process and compared hardness and fatigue mechanical properties. The hardness is compatible with the heat treatment and the microstructure present in each condition. The shot peening induced a compressive residual stress which increased the fatigue life of SAE 9254 steel. The residual stress profile from the surface of springs showed a peak in the values of compressive stress for both manufacturing processes. The maximum residual stress in the cold processed spring was higher than the hot processed spring and maintained much higher values along the thickness of the spring from the surface, resulting from manufacturing processes. The fatigue cracking of the springs, produced by both process without shot peening, started by torsional fatigue process, with typical macroscopic propagation, showing stretch marks with high plastic deformation depending on the request type that accentuates the shear stresses. / A resistência à fadiga e a tenacidade são propriedades que exercem uma grande influência no desempenho das molas de suspensão dos veículos. A escolha do aço SAE 9254 ocorreu devido à sua ampla utilização na fabricação dessas molas e por possuir propriedades de fadiga e tenacidade. A fabricação de molas do aço SAE 9254 tem sido feita pelo processo de enrolamento a quente e submetido a tratamentos térmicos de têmpera e revenimento convencional ou pelo processo a frio e têmpera e revenimento por indução. Portanto, torna-se importante estudar o desempenho desse aço nesses dois processos. Esse trabalho investigou o efeito dos dois processos de produção e comparou as propriedades mecânicas em fadiga e dureza. Os valores de dureza das molas nas diversas condições investigadas estão compatíveis com o tratamento térmico e com a microestrutura presente em cada condição. O jateamento das molas induziu a uma tensão residual compressiva que aumentou consideravelmente a resistência à fadiga do aço SAE 9254. O perfil de tensão residual a partir da superfície das molas jateadas apresentou um pico nos valores de tensão de compressão para ambos os processos de fabricação. A tensão residual máxima na mola processada a frio e jateada foi superior à da mola processada a quente e mantiveram valores bem mais elevados ao longo da espessura da mola a partir da superfície, decorrentes dos processos de fabricação. As trincas por fadiga das molas fabricadas por ambos os processos sem jateamento tiveram seu início pelo processo de fadiga torcional, com propagação macroscópica típica, apresentando sinais de estrias com elevada deformação plástica em função do tipo de solicitação que acentua as tensões de cisalhamento.
26

Resistência de união de tratamentos de superfície realizados anteriormente à realização de restaurações em resina composta / Bonding strength of surface treatments performed prior to composite resin restorations

Colombini, Caio Piccolo 30 January 2019 (has links)
As lesões cervicais não cariosas (LCNCs) são definidas pela perda de estrutura dental na junção cemento/esmalte que envolve três mecanismos de estresse mecânico (tensão), atrito (fricção) e erosão (degradação química).. Existem tratamentos preventivos e dessensibilizantes para o principal sintoma das LCNCs, a hipersensibilidade dentinária cervical (HDC), porém, em casos que há perda de estrutura dental maior que 1mm é necessário realizar uma intervenção restauradora. Dessa forma, o objetivo deste estudo foi avaliar a resistência de união da dentina erodida e abrasionada modificada com diferentes pré-tratamentos e posteriormente restauradas com resina composta, através do teste de microtração. Para tanto, foram selecionados 40 molares humanos íntegros, que tiveram as porções oclusais seccionadas até exposição da dentina. Os espécimes passaram por desafio erosivo e abrasivo em uma ciclagem de 5 dias. Após os desafios, os espécimes receberam os tratamentos de superfície (n=10): G1: controle sem tratamento; G2: tratamento de superfície com ponta diamantada; G3: jateamento com óxido de alumínio, G4: ciclagem com enxaguatório fluoretado Elmex Erosion. Feito isso os espécimes foram restaurados, seccionados em palitos e submetidos ao teste de microtração em uma máquina universal de ensaios a 0,5mm/min. Para a analise estatística, foi utilizado o teste paramétrico de análise de variância (ANOVA) um fator e o teste auxiliar de Tukey. Foi observado que não houve diferença entre os tratamentos com ponta diamantada, óxido de alumínio e enxaguatório fluoretado. O único grupo a se diferenciar dos demais foi o grupo controle que apresentou valores de resistência de união inferiores. Dentro das limitações de um trabalho in vitro, conclui-se que os tratamentos de superfície estudados são procedimentos indicados para melhorar a adesão dental frente à necessidade de restaurar uma LCNC. / Non-carious cervical lesions (NCCLs) are defined by loss of dental structure at the cement/enamel junction involving three mechanisms of mechanical stress (tension), friction and erosion (chemical degradation). There are preventive and desensitizing treatments for the the main symptom of NCCLs, cervical dentin hypersensitivity (CDH), but in cases where there is loss of tooth structure greater than 1mm, a restorative intervention is necessary. Thus, the objective of this study was to evaluate the bond strength of the eroded and abraded dentin modified with different pre-treatments and later restored with composite resin, through the microtensile test. For this, 40 sound human molars were selected, which had the occlusal portions sectioned until exposure of the dentin. The specimens underwent erosive and abrasive challenge in a 5-day cycling. After the challenges, the specimens received the surface treatments (n = 10): G1: control without treatment; G2: surface treatment with diamond tip; G3: sandblasting with aluminum oxide, G4: cycling with fluoridated rinse Elmex Erosion. After this, the specimens were restored, sectioned on sticks and subjected to the microtensile test in a universal test machine at 0.5mm/min. For statistical analysis, the parametric analysis of variance (ANOVA) one factor and the Tukey auxiliary test were used. It was observed that there was no difference between treatments with diamond tip, aluminum oxide and fluoride. The only group to differentiate from the others was the control group that presented inferior bond strength values. Within the limitations of an in vitro work, it is concluded that the surface treatments studied are procedures indicated to improve dental adhesion in view of the need to restore NCCL.
27

Efeito de diferentes tratamentos de superfície na resistência de união de um cimento resinoso à zircônia

Scaffa, Polliana Mendes Cándia 13 March 2009 (has links)
As ceramicas a base de zirconia (Y-TZP) apresentam propriedades mecanicas superiores as das demais ceramicas odontologicas. Entretanto, o aumento do conteudo cristalino modificou suas caracteristicas de adesao a cimentos resinosos, tornando necessario o desenvolvimento de metodos mais efetivos de uniao a estes materiais. Este trabalho in vitro pretende, portanto, avaliar a influencia de diferentes tratamentos de superficie e de diferentes agentes de uniao na resistencia ao cisalhamento entre uma zirconia estabilizada por itrio e um agente cimentante autoadesivo (RelyX U100®/3M ESPE). Para tal, cilindros de PROCERA® Allzircon receberam como tratamento de superficie jateamento com oxido de aluminio (Al2O3 - 50 m) ou jateamento com o sistema Rocatec. Sobre a superficie tratada dos cilindros foram aplicados, de acordo com os diferentes grupos experimentais, o sistema adesivo Clearfil SE Bond® (Kuraray Co.), e os primers Metal Zirconia Primer (Ivoclar Vivadent) e Alloy Primer (Kuraray Co.) e, finalmente, o cimento resinoso adotado. Cada especime foi, entao, submetido ao teste de cisalhamento (0,05 mm/min), por meio da acao de uma alca de fio ortodontico passando o mais próximo possivel da interface adesiva. A analise de variancia a um criterios (ANOVA) e o teste de Tukey (p<0,05) mostraram que a realizacao do tratamento de superfície aumentou os valores de resistencia de uniao entre a ceramica e o cimento resinoso. O jateamento com o sistema Rocatec (15,33 MPa) apresentou valores significantemente maiores que o jateamento com Al2O3 (11,93 MPa). A aplicacao dos agentes de uniao resultou em uma maior resistencia adesiva, sendo que o sistema adesivo Clearfill SE Bond (17,07 MPa) teve um comportamento estatisticamente superior aos demais materiais. Entre os primers, o Metal Zirconia Primer (11,26 MPa) apresentou maior valor de resistencia de uniao que o Alloy Primer (10,01 MPa). Portanto, a associacao de um tratamento superficial com um agente de união e valida, ja que promoveu os maiores valores de resistencia adesiva. / Yttrium-stabilized tetragonal zircon polycrystal (Y-TZP) ceramics show better mechanical properties than other dental ceramics. However, the high crystalline content modified their adhesiveness to resin cements, making it extremely necessary to develop a more effective adhesive strategy between them. This in vitro study intends to evaluate the influence of different surface treatments and different bond agents on the shear bond strength between a Y-TZP and self-adhesive resin cement. PROCERA® Allzircon cylinders (3.5 mm in diameter) received a surface airborne abrasion treatment with 50 m aluminum-oxide (Al2O3) particles or with the Rocatec system. According to the experimental groups, the adhesive system Clearfil SE Bond® (Kuraray Co.), and the primers Metal Zirconia Primer (Ivoclar Vivadent) and Alloy Primer (Kuraray Co.) were applied on the treated surface of the cylinders, before the application of the adopted resin cement (RelyX U100®/3M ESPE). Each specimen was submitted to the shear bond strength test (0.5 mm/min), by the action of an orthodontic stainless steel ligature wire (0.5 mm in diameter) loop, wrapped around the resin cement, as close as possible to the adhesive interface. One way-ANOVA and Tukey´s post hoc tests (p<0.05) revealed that surface treatment increased bond strength between the ceramic and the resin cement. Silica coating with the Rocatec system (15.33 MPa) showed significantly higher values than airborne abrasion with Al2O3 (11.93 MPa). Application of all bond agents improved shear bond strength: adhesive system Clearfil SE Bond (17.07 MPa) showed better performance than the other evaluated materials, and Metal Zirconia Primer (11.26 MPa) showed higher bond strength values than Alloy Primer (10.01 MPa). Therefore, the association of a surface treatment with a bond agent is suitable, once it resulted in higher values of adhesive strength.
28

Efeito de diferentes tratamentos de superfície na resistência de união de um cimento resinoso à zircônia

Polliana Mendes Cándia Scaffa 13 March 2009 (has links)
As ceramicas a base de zirconia (Y-TZP) apresentam propriedades mecanicas superiores as das demais ceramicas odontologicas. Entretanto, o aumento do conteudo cristalino modificou suas caracteristicas de adesao a cimentos resinosos, tornando necessario o desenvolvimento de metodos mais efetivos de uniao a estes materiais. Este trabalho in vitro pretende, portanto, avaliar a influencia de diferentes tratamentos de superficie e de diferentes agentes de uniao na resistencia ao cisalhamento entre uma zirconia estabilizada por itrio e um agente cimentante autoadesivo (RelyX U100®/3M ESPE). Para tal, cilindros de PROCERA® Allzircon receberam como tratamento de superficie jateamento com oxido de aluminio (Al2O3 - 50 m) ou jateamento com o sistema Rocatec. Sobre a superficie tratada dos cilindros foram aplicados, de acordo com os diferentes grupos experimentais, o sistema adesivo Clearfil SE Bond® (Kuraray Co.), e os primers Metal Zirconia Primer (Ivoclar Vivadent) e Alloy Primer (Kuraray Co.) e, finalmente, o cimento resinoso adotado. Cada especime foi, entao, submetido ao teste de cisalhamento (0,05 mm/min), por meio da acao de uma alca de fio ortodontico passando o mais próximo possivel da interface adesiva. A analise de variancia a um criterios (ANOVA) e o teste de Tukey (p<0,05) mostraram que a realizacao do tratamento de superfície aumentou os valores de resistencia de uniao entre a ceramica e o cimento resinoso. O jateamento com o sistema Rocatec (15,33 MPa) apresentou valores significantemente maiores que o jateamento com Al2O3 (11,93 MPa). A aplicacao dos agentes de uniao resultou em uma maior resistencia adesiva, sendo que o sistema adesivo Clearfill SE Bond (17,07 MPa) teve um comportamento estatisticamente superior aos demais materiais. Entre os primers, o Metal Zirconia Primer (11,26 MPa) apresentou maior valor de resistencia de uniao que o Alloy Primer (10,01 MPa). Portanto, a associacao de um tratamento superficial com um agente de união e valida, ja que promoveu os maiores valores de resistencia adesiva. / Yttrium-stabilized tetragonal zircon polycrystal (Y-TZP) ceramics show better mechanical properties than other dental ceramics. However, the high crystalline content modified their adhesiveness to resin cements, making it extremely necessary to develop a more effective adhesive strategy between them. This in vitro study intends to evaluate the influence of different surface treatments and different bond agents on the shear bond strength between a Y-TZP and self-adhesive resin cement. PROCERA® Allzircon cylinders (3.5 mm in diameter) received a surface airborne abrasion treatment with 50 m aluminum-oxide (Al2O3) particles or with the Rocatec system. According to the experimental groups, the adhesive system Clearfil SE Bond® (Kuraray Co.), and the primers Metal Zirconia Primer (Ivoclar Vivadent) and Alloy Primer (Kuraray Co.) were applied on the treated surface of the cylinders, before the application of the adopted resin cement (RelyX U100®/3M ESPE). Each specimen was submitted to the shear bond strength test (0.5 mm/min), by the action of an orthodontic stainless steel ligature wire (0.5 mm in diameter) loop, wrapped around the resin cement, as close as possible to the adhesive interface. One way-ANOVA and Tukey´s post hoc tests (p<0.05) revealed that surface treatment increased bond strength between the ceramic and the resin cement. Silica coating with the Rocatec system (15.33 MPa) showed significantly higher values than airborne abrasion with Al2O3 (11.93 MPa). Application of all bond agents improved shear bond strength: adhesive system Clearfil SE Bond (17.07 MPa) showed better performance than the other evaluated materials, and Metal Zirconia Primer (11.26 MPa) showed higher bond strength values than Alloy Primer (10.01 MPa). Therefore, the association of a surface treatment with a bond agent is suitable, once it resulted in higher values of adhesive strength.

Page generated in 0.3037 seconds