• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 8
  • 8
  • 8
  • 8
  • 7
  • 1
  • Tagged with
  • 24
  • 24
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Tratamento a plasma para melhoria na metalização de placas de circuito impresso / Plasma treatment for improved metallization of printed circuit boards

Laraia, André Bianchi 31 July 2018 (has links)
Submitted by André Bianchi Laraia (andreblaraia@yahoo.com.br) on 2018-08-29T22:49:26Z No. of bitstreams: 1 Dissertacao-Andre-Bianchi-Laraia.pdf: 2142300 bytes, checksum: 9264414d38ac4ce5ec3be46acb98ca44 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: • Necessário fazer ajuste no sumario na lateral direita nas numerações. • A palavra APÊNDICE A deve ser centralizada A palavra APÊNDICE A deve ser centralizada • Referências. A palavra Referências deve ser centralizada, As referencias devem ser justificadas, espaço simples com um espaço simples(enter) entre elas. • Sobre a elaboração das referencias e citações favor solicitar orientação para ajuste com a bibliotecária Pâmella - pamella.benevides@unesp.br • A palavra APÊNDICE A deve ser centralizada Mais informações acesse o link: http://www2.feg.unesp.br/Home/Biblioteca21/diretrizes-2016.pdf Agradecemos a compreensão. on 2018-08-30T12:07:55Z (GMT) / Submitted by André Bianchi Laraia (andreblaraia@yahoo.com.br) on 2018-09-12T01:58:28Z No. of bitstreams: 1 Tese-Andre-Bianchi-Laraia-v20-converted.pdf: 2144718 bytes, checksum: eef37a1c04c8a387ddbff2e31f67db35 (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-09-12T17:38:03Z (GMT) No. of bitstreams: 1 laraia_ab_me_guara.pdf: 2144718 bytes, checksum: eef37a1c04c8a387ddbff2e31f67db35 (MD5) / Made available in DSpace on 2018-09-12T17:38:03Z (GMT). No. of bitstreams: 1 laraia_ab_me_guara.pdf: 2144718 bytes, checksum: eef37a1c04c8a387ddbff2e31f67db35 (MD5) Previous issue date: 2018-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta o desenvolvimento de um processo de tratamento com plasma para melhorar ametalização química de placas de circuito impresso (PCI). A pluma de plasma é gerada em argônio a partir da descarga de barreira dielétrica (DBD) promovida entre uma agulha cirúrgica e um cilindro usando capilar de borosilicato como dielétrico. A tensão picoa-pico aplicada foi de 5 kV, com forma de onda senoidal na frequência de 37 kHz e potência de descarga em torno de 765 mW. O substrato é um composto de fibra de vidro e resina epóxi. Com incidência perpendicular da pluma de plasma na superfície, o diâmetro da área tratada circular é de 10 mm. Desta forma, o ângulo de contato reduz de 75 ° a 45 ° com 3 s de interação entre superfície da amostra e a ponta do plasma e o ângulo atinge o mínimo de 33 ° após 180 s de tempo de tratamento. A metalização química foi feita com banhos seqüenciais de solução de paládio e finalizada com banho de solução aquosa de cobre. Testes de adesão padrão mostraram uma forte adesão das camadas de metal nas superfícies previamente tratadas com as plumas de plasma. Esta adesão melhora com o tempo de tratamento. A melhoria na metalização foi observada em superfície plana e também em furos usados para conectar diferentes camadas em PCIs. A área metalizada na superfície dos buracos é maior nos orifícios tratados. Quanto maior o tempo de tratamento, maior é essa área. Todos os resultados indicaram que a técnica de tratamento por plasma de placas de fibra de vidro melhora a sua metalização química pelo cobre, levando a uma adesão mais uniforme e eficaz do metal à superfície com um método ambientalmente amigável / This work reports the development of a plasma treatment process to improve the chemical metallization of printed circuit boards (PCB). The plasma plume is generated in argon from a dielectric barrier discharge (DBD) promoted between a surgical needle and a cylinder using a borosilicate capillary as dielectric. The applied peak-to-peak voltage was 5 kV, with sinusoidal waveform at 37 kHz frequency and power in the discharge around 765 mW. The substrate was a composite of fiberglass and epoxy resin. With perpendicular incidence of the plasma plume on the surface the diameter of the circular treated area was 10 mm. In this area the contact angle reduces from 75° to 45° with 3 s of the plasma-surface interaction and the angle reaches the minimum of 33° after 180 s of treatment time. Chemical metallization was made with sequential baths of solution of palladium and finished with bath of aqueous solution of copper. Standard adhesion tests showed a strong adhesion of the metal layer on surfaces previously treated with the plasma plumes. This adhesion improves with the treatment time. The improvement in the metallization was observed on flat surface and also in holes used to connect different layers in PCB’s. The metallized area on the surface of the holes is larger in treated holes. The longer the treatment time the larger is this area. All these results indicated that the technique of plasma treatment of fiberglass boards improves its chemical metallization by copper leading to a more uniform and effective adhesion of the metal to the surface with an environmental friendly method
22

Otimização e fabricação de dispositivos piezelétricos com gradação funcional de material. / Optimization and manufacturing of piezoelectric devices with functionally graded materials.

Ricardo Cesare Román Amigo 18 January 2013 (has links)
Cerâmicas piezelétricas possibilitam posicionamento e sensoriamento de precisão ou captação de energia mecânica valendo-se do efeito piezelétrico, capaz de converter energia mecânica em elétrica ou o contrário. Para aprimorar ou estender as aplicações dessas cerâmicas, mecanismos flexíveis podem ser acoplados a elas, formando um Dispositivo Piezelétrico Flextensional (DPF). No projeto desse tipo de estrutura, o conceito de Material com Gradação Funcional (MGF) é interessante, já que esses materiais apresentam variações graduais de suas propriedades efetivas, permitindo a alternância entre um material mais flexível e um mais rígido de acordo com a intensidade de deslocamento desejada em cada região da estrutura. Assim, neste trabalho, implementa-se o Método de Otimização Topológica (MOT) no projeto de estruturas gradadas com o intuito de identificar as vantagens e desvantagens da utilização do conceito de MGF em DPF. Esse método combina algoritmos de otimização e o Métodos dos Elementos Finitos (MEF) para distribuir material dentro de um domínio fixo através de um modelo de material, que no presente caso é o de Material Isotrópico Sólido com Penalização (MISP) adaptado a MGF. Na fabricação desses dispositivos otimizados, utiliza-se a Sinterização por Jato de Plasma (SJP) para a obtenção de tarugos gradados que são submetidos a processos de eletro-erosão e de corte a laser. Por fim, para a verificação dos resultados numéricos, utiliza-se um vibrômetro para aferir os deslocamentos dos protótipos de atuadores fabricados. / Piezoelectric devices enable precision positioning and sensing or mechanical energy harvesting based on the piezoelectric effect. In flextensional piezoelectric devices, flexible coupling structures are attached to ceramics to improve or extend the application possibilities. On the design of this kind of structure, the concept of Functionally Graded Materials (FGM) can be interesting, since it allows gradual variations of its effective properties along some direction by mixing two or more materials. Thus, in order to identify the advantages and disadvantages of using FGM, graded flexible coupling structures that maximize the performance of piezoelectric devices are obtained by implementing the Topology Optimization Method (TOM). This method combines optimization algorithms and the Finite Element Method (FEM) to distribute material inside a fixed domain. In this work, the formulation is based on the Solid Isotropic Material with Penalization (SIMP) material model adapted for the FGM concept, which can represent continuous change in material properties along the domain. Resulting optimal graded topologies of coupling structures are presented and compared with homogeneous structures. Finally, graded devices are manufactured through Spark Plasma Sintering (SPS) technique in order to be characterized, validating numerical results. The numerical results demonstrate the TOM efficacy in designing functionally graded piezoelectric devices and show, by its implementation, significant gains in graded mechanisms performance when compared with analogous homogeneous. Furthermore, the feasibility of proposed manufacturing process is confirmed, allowing the fabrication of prototypes with expected behavior.
23

Desenvolvimento e aplicação de jato de plasma frio em pressão atmosférica para o tratamento de materiais e sementes /

Mui, Taiana She Mir. January 2020 (has links)
Orientador: Rogério Pinto Mota / Resumo: Esta tese teve como o intuito o estudo e caracterização de jatos de plasma com diferentes diâmetros no tratamento do polímero Politereftalato de Etileno (PET), visando estudar a uniformidade e a área de alcance dos tratamentos. Posteriormente, um desses jatos foi utilizado para o tratamento de sementes de girassol, com o objetivo de investigar as modificações superficiais, físico-químicas e o comportamento biológico das sementes após os tratamentos a plasma, buscando compreender os mecanismos de interação do plasma com as sementes. A caracterização superficial do PET foi realizada através de medições de ângulo de contato, rugosidade e análise das mudanças químicas com a Espectroscopia de Fotoelétrons Excitados por Raios X (XPS). Enquanto que, as caracterizações realizadas nas sementes foram medidas de ângulo de contato, absorção de água e corante, perda de massa, Espectroscopia no Infravermelho com Transformada de Fourier por Refletância Total Atenuada (FTIR-ATR) e Microscopia Eletrônica de Varredura (MEV). Para avaliação da parte biológica foram realizados ensaios de taxa de germinação e de taxa de crescimento. Os tratamentos no PET com os três jatos de plasma utilizados demonstraram uma diminuição considerável nos valores de ângulo de contato e a área de tratamento alcançada por cada jato foi devidamente calculada. Através do aumento dos valores da rugosidade foi possível verificar que o tratamento a plasma estendeu-se para fora do cone do jato. Houve também incorporação de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this thesis was to study and characterize plasma jets with different diameters in the treatment of polyethylene terephthalate (PET) in order to study the treatment range and uniformity. Subsequently, one of these jets was used for the treatment of sunflower seeds, with the objective to investigate the seeds surface, physicochemical changes and the biological behavior of the seeds after the plasma treatments, seeking to understand the mechanisms of the interaction of the plasma with the seeds. The superficial characterization of the PET was performed through measurements of water contact angle, roughness and analysis of chemical changes with X-ray Photoelectron Spectroscopy (XPS). While, the characterizations performed on sunflower seeds were water contact angle, water and dye absorption, mass loss, Fourier Transform Infrared Spectroscopy by Total Attenuated Reflectance (FTIR-ATR) and Scanning Electronic Microscopy (SEM). For the biological evaluation germination rate and growth rate tests were performed. The treatments on PET with the three plasma jets showed a considerable decrease in water contact angle values and the treatment area obtained by each jet was calculated. By increased roughness values it was possible to verify that the plasma treatment extended outside the cone of the jet. There was also incorporation of functional groups of O, increase of small amounts of N and removal of contaminants in the plasma treated PET samples confirmed by the XPS analy... (Complete abstract click electronic access below) / Doutor
24

Filmes biocompatíveis obtidos da polimerização a plasma das misturas dos monômeros HEMA/DEAEMA e THFMA/MOx para aplicações em drug delivery /

Kodaira, Felipe Vicente de Paula. January 2020 (has links)
Orientador: Rogério Pinto Mota / Resumo: Polímeros a plasma são uma classe de materiais que possuem aplicações em diversos tipos de indústrias, como biomédica, alimentícia, embalagens, eletrônica, farmaceutica, entre outras. Esses materiais possuem características que os diferem dos polímeros convencionais, como uma estrutura química ordenada aleatoriamente, boa adesão a diferentes substratos e possuem cadeias muito entrelaçadas. Estes polímeros podem ser utilizados para a função de drug delivery, podem ser carregados com um medicamento e liberá-lo quando in vivo, este conceito de drug delivery permite a realização de um tratamento localizado e com uma dose mais segura de medicamento. O processo de polimerização a plasma também tem características que o difere da polimerização convencional, ele é capaz de realizar reações que demandam muita energia e não poderiam acontecer por química convencional, os parâmetros aplicados podem ser ajustados para customizar até certo ponto o material obtido e não gera resíduos. Inicialmente a polimerização a plasma era realizada em baixa pressão, mais recentemente a alternativa de realizar o processo em pressão atmosférica vêm ganhando destaque por ser relativamente mais barata e pelas características diferentes da descarga e dos polímeros a plasma resultantes. Existem muitas configurações de fontes de plasma em pressão atmosférico, dentre elas os jatos de plasma (APPJs), nestas fontes o plasma é gerado por descargas DBD ou corona no interior de tubos ou cavidades e é expelida para ... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor

Page generated in 0.0427 seconds