• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cost Evaluation of Seismic Load Resistant Structures Based on the Ductility Classes in Eurocode 8 / Kostnadsbedömning av konstruktioner påverkade av jordbävningslaster utifrån duktilitetsklasserna i Eurokod 8

Drivas, Georgios Valdemar January 2014 (has links)
Most people do not associate Scandinavia with seismic activity and earthquakes; however, there is in fact seismic activity in the region. Although in comparison with southern Europe the return periods of earthquakes with large magnitudes are quite long, itis critical to consider earthquake impact when designing structures. Earthquake impact is difficult to predict, but building standards provide guidance to safely designstructures based on statistical and empirical data specific to regional conditions andcircumstances. Crucial for the final impact and response of a structure is not only theground acceleration, but also the ground type, which can amplify seismic vibrationsand ultimately cause unfortunate damage to the structural elements. Since 2010 Eurocode 8, the European standards for seismic design has been in effectfor building structures in Norway. The main difference with the application of thestandards in Norway compared to Southern Europe is the choice between elastic andductile design in some cases. Presumably, the same design regulations are applicablefor design of structures in Sweden, because parts of Sweden share similar conditionsas in Norway. This master thesis examines the results of selecting between elastic andductile design based on an arbitrary finite element model, and ultimately, presentsthe differences in cost efficiency in both quantitative and qualitative measures. In the arbitrary structure that is analyzed, the lateral bearing system contains a concrete wall shaft. In order to evaluate profitability, the cost development of reinforcement in the walls, is analyzed based on ground acceleration and ductility class. Thestudy ultimately implies a breaking point when structures in ductility class mediumare more cost efficient than structures in ductility class low and vice versa, with thecondition that the governing lateral force is the seismic vibration and that the normalized axial force is less than 15% / Skandinavien förknippas inte i första hand med seismisk aktivitet och jordbävningar.I regionen förekommer seismisk aktivitet, dock är returperioderna för jordbävningarmed stor magnitud förhållandevis lång i relation till södra Europa. Jordbävningslasterär svåra att förutse, men byggnormerna vägleder till säkert utformande och dimensionering mot dess påverkan, baserat på statistiska och empiriska data för regionala förutsättningar och omständigheter. En avgörande faktor för konstruktioners inverkan och respons är inte endast markaccelerationen utan även marktypen som kanförstärka de seismiska vibrationerna och eventuellt orsaka skada på byggnader. I Norge används sedan 2010 de europeiska normerna för jordbävningsdimensionering, Eurokod 8. Den väsentliga skillnaden jämfört med utförandet av konstruktioneri södra Europa är att valet mellan elastiska och duktila utformanden ges i vissa fall.Hypotetiskt kan samma normer användas för dimensionering av byggnader i Sverige,eftersom vissa regioner i Sverige har samma förutsättningar som i Norge. I detta examensarbete undersöks valet mellan elastisk och duktil dimensionering medhjälp av finita element modellering av en godtycklig konstruktion samt en jämförelseav de två fallen som slutligen leder till en analys av kostnadseffektiviteten, både kvantitativt och kvalitativt. Det horisontella bärsystemet i den använda modellen är ett schakt bestående av betongväggar. För att kunna uppskatta lönsamheten analyseras kostnadsutvecklingenav armeringsinnehållet, beroende av markacceleration och duktilitetsklass. Studienhar resulterat i definitionen av en brytpunkt som anger när dimensionering enligtduktilitetsklass medium är effektivare än dimensionering enligt duktilitetsklass lågoch vice versa, under förutsättning att jordbävningslasten är dimensionerande ochden normaliserade axialkraften är lägre än 15%.
2

Seismic analysis of concrete structures within nuclear industry / Dimensionering av nukleära betongkonstruktioner med avseende på seismisk påverkan

Tabatabaei Araghi, Pedram January 2014 (has links)
Earthquake has always been a hazard for civil structures and keeping the structures integrity during and after an earthquake is of vital importance. This phenomenon’s impact is sudden and there is little or no warning to make the preparations for this natural disaster. Much damage has been done on structures which have led to major collapses and loss of many lives. Civil structures such as nuclear power plants are designed to withstand earthquakes and in the event of a major seismic event, to shut down safely. The aim of this thesis is to present the seismic design procedures for concrete structures, in basic and detailed design, according to Eurocode 8. Also to describe and understand the difference between Eurocode 8 and the DNB in seismic analysis of nuclear power plants. To evaluate the use of DNB instead of Eurocode 8 with Swedish seismic conditions is also another aim in this thesis.  Loads and actions which apply on a structure in a seismic design and corresponding load combinations are presented for Eurocode 8 and the DNB. An example is also given to clarify the design of primary seismic beams and columns with high ductility class (DCH). A case study of a nuclear structure from a test project named SMART2013 has been made by analyzing and comparing the results from Eurocode 8 and the DNB with a finite element model in FEM-Design software. Natural frequencies of the model are compared with the tested model in SMART2013-project to evaluate the finite element modeling. The model is seismically analyzed with load combinations from Eurocode 8 and the DNB with Swedish elastic ground response spectrum with the probability of 10-5. Results obtained from the primary seismic beams and columns are compared and analyzed.  Being on the safe and conservative side of the design values is always preferred in seismic analysis of a vital and sensitive structure such as nuclear power plants. The results from this thesis shows that, purely structural, combination of Swedish elastic ground response spectrum with the Eurocode 8 load combination will give more conservative values than the DNB. / I stora delar av världen har jordbävningar alltid varit ett hot för byggnaders integritet. Karaktären av en jordbävning är plötslig och föranleds av små eller inga varningar. Om jordbävningen medför att byggnader kollapsar sker ofta stora förluster av människoliv direkt eller indirekt. Kärnkraftsverk är anläggningar som dimensioneras för att klara jordbävningar och ska kunna gå till säker avställning vid en sådan händelse. Syftet med föreliggande rapport är att presentera hur betongkonstruktioner dimensioneras för jordbävning enligt Eurokod 8. Rapporten redogör även för skillnader mellan att dimensionera enligt Eurokod 8 och DNB (Dimensionering av nukleära byggnadskonstruktioner) samt hur det slår att använda Eurokod med svenska seismiska förhållanden. Laster och lastkombinationer som används vid jordbävningsdimensionering av betongbyggnader är presenterad enligt både Eurokod och DNB. Ett exempel presenteras för att visa hur primära balkar och pelare med hög duktilitetsklass (DCH) dimensioneras för seismisk påverkan. En fallstudie av en nukleär byggnad från ett internationellt projekt, SMART2013, har använts för att analysera och utvärdera resultaten från Eurokod och DNB. Byggnaden har analyserats med finita element med programvaran FEM Design. Modellens riktighet har verifierats genom att jämföra bland annat egenfrekvenser med de från officiella rapporter från SMART2013. Byggnaden är analyserad för seismisk last enligt svenska förhållanden med markresponsspektra 10-5, och primära balkar och pelare har analyserats och utvärderats enligt både Eurokod och DNB.

Page generated in 0.1041 seconds