• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 9
  • 7
  • 5
  • Tagged with
  • 76
  • 23
  • 20
  • 13
  • 11
  • 11
  • 11
  • 11
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Expression zytoskeletaler Filamente und des vascular endothelial growth factor (VEGF) systems in der endotheliochorialen Plazenta von Hund und Katze

Bezler, Linn. January 2008 (has links) (PDF)
Zugl.: Giessen, Universiẗat, Diss., 2008.
52

Der Einsatz von Lactoferrin und Epigallocatechingallat in der Prophylaxe parodontaler Erkrankungen der Katze

Gorissen, Sonja Maria Elisabeth. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2004--München.
53

Sekundär-intraokulare (metastatische) Tumoren der Uvea anamnestische und ophthalmopathologische Untersuchung von 31 Fällen bei Hund, Katze und Kaninchen /

Hieber, Ewald. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2004--München.
54

Computertomographische und magnetresonanztomographische Anatomie der Speicheldrüsen der Katze

Fromme, Vivian 19 May 2017 (has links) (PDF)
Zielstellung: Die Verwendung von Computertomographie und Magnetresonanzto-mographie zur Diagnostik von pathologischen Weichteilveränderungen, wie Läsionen der Speicheldrüsen, wird empfohlen. Diese begründet sich in Ihrer hohen Bildauflö-sung und dem guten Bildkontrast. Nach unserem Wissen gibt es aktuell keine publi-zierte Literatur, welche sich mit der CT- oder MRT-Anatomie der Speicheldrüsen der Katze beschäftigt. Ziel der vorliegenden Arbeit war es daher, Schnittbildmerkmale der Speicheldrüsen zu definieren und Landmarken für eine sichere Identifikation zu be-schreiben. Material und Methoden: Es wurden zwei Gruppen von Katzen untersucht. Die pros-pektiv untersuchten Tiere bestanden aus 16 Katzen, welche aus Gründen euthana-siert wurden, die nicht in Zusammenhang mit der Studie standen. Diese erfuhren ein CT (1 mm Schichtdicke) und 0,5 Tesla MRT (T2W, T2W SPIR, PDW, T1W) des Kop-fes. Im retrospektiven Anteil der Studie wurden CT-Untersuchungen (0,8-1 mm Schichtdicke) von 25 Katzen und MRT-Untersuchungen (T2W, T1W vor und nach Kontrastmittelgabe) von 21 Katzen verwendet. Diese Untersuchungen wurden zwi-schen 2005 und 2013 in unserer Klinik angefertigt. Dabei konnten keine Pathologien in Zusammenhang mit den Speicheldrüsen festgestellt werden. Alle Speicheldrüsen wurden bezüglich Identifizierbarkeit, Abgrenzbarkeit, Größe und Signalverhalten un-tersucht. Wenn vorhanden, wurden anatomische Landmarken die Speicheldrüsen umgebend notiert. Zusammenfassung 80 Ergebnisse: 94,3% der Glandulae parotidae, 90,7% der Glandulae mandibulares und 96,8% der Glandulae zygomaticae konnten mit dem CT identifiziert werden. Beim MRT waren es 94,1% der Glandulae parotidae, 99,2 % der Glandulae mandibulares, 88,9% der Glandulae zygomaticae und 51,4 % der Glandulae buccalis ventralis. In beiden Gruppen konnten keine der restlichen kleinen Speicheldrüsen identifiziert werden, dies galt für beide Schnittbildverfahren. Als hilfreiche anatomi-sche Landmarken konnten der äußere Gehörgang, der M. masseter, der M. pterygo-ideus medialis und der Bulbus oculi herangezogen werden. Die medianen Dichtewer-te lagen für die Glandula parotis, die Glandula mandibularis und die Glandula zygo-matica bei 65 HU, 62 HU und 57 HU. Die Parotis war überwiegend dezent hyperin-tens zur Muskulatur und hypointens zum Fett. Die Mandibularis, Zygomatica, und Glandula buccalis ventralis stellten sich hauptsächlich hyperintens zur Muskulatur und hypointens zu Fettgewebe dar. Dieses Signalverhalten war für T1W, T2W und T2W SPIR (fettunterdrückt) gewichtete Sequenzen gleich. Die Größe war für beide Gruppen und Modalitäten vergleichbar und lag bei circa 17 x 6 mm (gemessen von lateral nach medial und von dorsal nach ventral) bei der Glandula parotis, 8 x 17 mm bei der Glandula mandibularis, 10 x 7 mm bei der Glandula zygomatica und bei der Glandula buccalis ventralis 3 x 10 mm. Schlussfolgerungen: Landmarken und Aussagen über die Signalintensität bezie-hungsweise Dichte und die Größe der Glandula parotis, Glandula mandibularis, Glandula zygomatica und der Glandula buccalis ventralis konnten erhoben werden. Die mangelhafte Identifizierbarkeit der restlichen kleinen Speicheldrüsen, im Ver-gleich zu den oben genannten, kann vor allem mit dem unzureichenden Weichteil-kontrast zum umliegenden Gewebe im CT und der niedrigen Auflösung des Nieder-feld-MRTs erklärt werden. Neuere MRT-Techniken können detailliertere Bilder er-zeugen und so eine Beschreibung der kleinen Speicheldrüsen ermöglichen. / Objective: Due to their high resolution and useful contrast resolution, CT and MRI are recommended methods for diagnosing pathological changes of soft tissues such as lesions of the salivary glands. To our knowledge, no studies about the CT or MR anatomy of the feline salivary glands have been published yet. The aim of the study was to define anatomical characteristics of the salivary glands in cross-sectional im-ages and to describe landmarks for a reliable identification. Materials and methods: Two groups of cats where examined. In a prospective trial, 16 cats, euthanized for reasons unrelated to the study, underwent a head CT (1 mm slice thickness) and 0.5 Tesla MRI scans (T2W, T2W SPIR, PDW, T1W). In a retro-spective trial, the CT scans (0.8-1 mm slice thickness) of 25 cats and the MR scans (T2W, T1W, pre- and post-contrast) of 21 cats were used. These scans were per-formed at our clinic between 2005 and 2013. No signs of salivary-gland-related pa-thologies were visible. All images were reviewed with respect to the following criteria: the presence, delineation and size of the salivary glands as well as the signal intensi-ty. Anatomical landmarks surrounding the glands were also recorded. Results: 94.3% of the parotid glands, 90.7% of the mandibular glands and 96.8% of the zygomatic glands could be delineated using CT. With MRI, 94.1% of the parotid Summary 82 glands, 99.2 % of the mandibular glands, 88.9% of the zygomatic glands and 51,4 % of the ventral buccal glands could be identified. In both groups the other small salivary glands could not be visualized neither in CT nor in MRI. Anatomical landmarks such as the external ear canal, the M. masseter, the M. pterygoideus medialis and the Bulbus oculi facilitate the identification. The mean density of the parotid gland, the mandibular gland and the zygomatic gland was 65 HU, 62 HU and 57 HU, respectively. The parotid gland was mainly modestly hyperintense to muscle and hypointense to fat. The mandibular, zygomatic and ven-tral buccal glands were hyperintense to muscle and hypointense to fat. Signal intensi-ties were similar for T1W, T2W and T2W SPIR images. Sizes were comparable for both groups and modalities and measured about 17x6 mm (lateral to medial and dor-sal to ventral) for the parotid gland, 8 x 17 mm for the mandibular gland, 10x7 mm for the zygomatic gland and 3x10 mm for the ventral buccal gland. Conclusions: Landmarks were recorded and data regarding the density/signal in-tensity and the size of the parotid gland, the mandibular gland, the zygomatic gland and the ventral buccal gland could be gathered. The discrepancy between depicting the small glands and the above mentioned glands can be explained mainly by the lack of contrast to the surrounding tissue in CT and the low spatial resolution in low-field MRI. Advanced MRI techniques are expected to produce more detailed images and therefore those techniques could be used to also describe the small salivary glands.
55

Möglichkeiten und Grenzen von Projektionsradiographie und Computertomographie bei der Detektion pulmonaler Rundherde bei Hund und Katze

Niesterok, Christian 25 November 2016 (has links) (PDF)
Einleitung: Der frühzeitigen Detektion pulmonaler Rundherde kommt eine Schlüsselrolle bei neoplastischen Erkrankungen von Hund und Katze zu, indem sie maßgeblich Prognose und Behandlungsoptionen beeinflusst. Ziel unserer ersten Studie war, die aktuelle diagnostische Wertigkeit und mögliche Limitationen der klassischen Röntgenuntersuchung bei der Detektion pulmonaler Rundherde darzustellen. Unsere zweite Untersuchung beschäftigt sich mit dem Ziel der computerassistierten Detektion (CAD) und deren Einsatz in der Tiermedizin. Material und Methoden: Der Untersuchungszeitraum umfasste die Jahre 2005–2011. In die erste Studie wurden Hunde und Katzen mit pulmonalen Rundherden aufgenommen, an denen zunächst eine klassische Röntgenuntersuchung und anschließend innerhalb von 14 Tagen eine computertomographische Untersuchung (CT) durchgeführt wurde. Neben der Darstellung möglicher Limitationen der klassischen Röntgenuntersuchung wurde auch deren Sensitivität hinsichtlich des Vorliegens pulmonaler Rundherde im Vergleich zur CT als Goldstandard untersucht. Gemäß den Einschlusskriterien wurden 50 Hunde und 20 Katzen in die erste Studie aufgenommen. Die zweite Untersuchung beschäftigt sich mit der Sensitivität eines computerassistierten Detektionssystems sowie dessen möglichen Mehrgewinns für den Radiologen bei der Detektion pulmonaler Rundherde in der Tiermedizin. Darüber hinaus wurden die möglichen Limitationen eines solchen Systems untersucht. In die Untersuchung wurden nicht nur Tiere mit Rundherden eingeschlossen, sondern auch solche mit Massen (Herde größer 3 cm). Ausgeschlossen waren Patienten mit mehr als 50 Rundherden pro Lungenhälfte sowie Rundherde/Massen, die vollständig in Atelektasen eingebettet waren. Gemäß den Einschlusskriterien wurden bei 51 Hunden und 16 Katzen insgesamt 586 Rundherde als Referenzwert für die CAD zugrunde gelegt. Ergebnisse: Als ein Ergebnis aus der vorliegenden ersten Studie zeigt sich für die Projektionsradiographie eine Detektionsrate von insgesamt 61 % (64 % für Hunde und 55 % für Katzen) verglichen mit der CT als Goldstandard. Gründe für eine fehlende Detektion liegen vor allem darin, dass die Röntgenuntersuchung im Ergebnis ein Summationsbild liefert. Daneben spielt auch die Rundherdgröße eine (untergeordnete) Rolle. Das in der zweiten Studie eingesetzte Detektionssystem zur computerassistierten Detektion pulmonaler Rundherde wies für die Tiermedizin eine Sensitivität von 69,4 % auf. Gleichzeitig wurde eine hohe Anzahl falsch positiver sowie falsch negativer Befunde durch die CAD verzeichnet. Dennoch ließ sich durch den Einsatz der CAD die Sensitivität von Untersucher 1 von 89,2 % auf 94,7 % steigern, die von Untersucher 2 von 87,4 % auf 90,8 %. Schlussfolgerungen: Aufgrund der engen Einschlusskriterien dieser Studie kann für die Detektion pulmonaler Rundherde in der Projektionsradiographie als Mindestwert die hier ermittelte durchschnittliche Sensitivität von 61 % zugrunde gelegt werden. Die klassische Röntgenuntersuchung eignet sich weiterhin als erstes bildgebendes Verfahren für die pulmonale Rundherddetektion, für ein genaues Staging sollte allerdings die CT angewandt werden. Für eine fehlende Rundherddetektion war nicht primär die geringe Größe der Rundherde ursächlich, sondern vielmehr Begleiterkrankungen, die mit einer Transparenzminderung der Lunge einhergingen. Daher sollte insbesondere dann die CT zum Einsatz kommen, wenn zusätzliche Veränderungen wie beispielsweise ein Pleuraerguss vorliegen. Für die Detektion pulmonaler Rundherde in der CT-Untersuchung gilt, dass die Sensitivität des Radiologen grundsätzlich durch ein automatisches Detektionssystem gesteigert werden kann. Somit eignet es sich insbesondere dann, wenn kein zweiter radiologischer Befunder vorhanden ist. Allerdings weist die CAD eine sehr hohe Anzahl falsch positiver sowie einige falsch negative Befunde auf, so dass sich für ihren routinemäßigen Einsatz in der Tiermedizin derzeit noch Limitationen ergeben. / Introduction: The early detection of pulmonary nodules plays a key role in neoplastic conditions of dogs and cats substantially influencing prognosis and therapy options. The aim of our first study was to outline the actual diagnostic value as well as the potential limitations of projection radiography for detection of pulmonary nodules. Our second study addresses the newer aspect of computer assisted detection (CAD) and its possible application in veterinary medicine. Materials and methods: The investigation period was between 2005 and 2011. In our first study we included those dogs and cats with pulmonary nodules that underwent a radiographic examination as well as a computed tomographic examination (CT) within a period of 14 days. Aside from the description of possible limitations of projection radiography, we also evaluated its sensitivity for detection of pulmonary nodules compared to CT as gold standard. According to the inclusion criteria 50 dogs and 20 cats were admitted to this study. The second study dealt with the sensitivity of a computer assisted detection system and its potential benefit for radiologists for the detection of pulmonary nodules in veterinary medicine. Furthermore, we outlined possible limitations of the detection system. This study not only comprised dogs and cats with pulmonary nodules, but also those with pulmonary masses (i.e. nodules > 3 cm). We excluded patients with more than 50 nodules either in the right or the left lung as well as nodules/masses embedded in a massive atelectasis. According to our inclusion criteria, we determined 586 nodules in total, distributed on 51 dogs and 16 cats used as reference value for the CAD. Results: As one result of our first study, we found a detection rate of 61 % (64 % for dogs and 55 % for cats) for projection radiography in comparison to CT as gold standard. Reasons for a missing detection of pulmonary nodules are predominantly limitations that come along with superimpositions using projection radiography; apart from that, nodule size is of some subsidiary meaning. The detection system for the computer assisted detection of pulmonary nodules used in the second study showed a sensitivity of 69.4 % in veterinary medicine. Additionally a high number of false positive findings as well as false negative findings was detected by CAD. However, due to the use of CAD the sensitivity of examiner 1 increased from 89.2 % to 94.7 %, the sensitivity of examiner 2 increased from 87.4 % to 90.8 %. Conclusions: Based on the strict inclusion criterion in this study the average sensitivity of 61 % can be used as a minimum for the detection of pulmonary nodules using radiographs. Projection radiography is suitable as first line diagnostic tool for the detection of pulmonary nodules. For accurate tumor staging CT should be used. Since predominant reasons for a missing detection of pulmonary nodules consisted of limitations that come along with superimpositions (like pleural effusion) CT is especially recommended in those cases. In general, the sensitivity of radiologists can be improved by an automatic detection system concerning the detection of pulmonary nodules using CT. Especially in those cases, when no second reader is available, CAD is suitable. However, the CAD system we used herein yielded a high number of false positive findings as well as false negative findings; therefore, its use in veterinary medicine on a routine basis still has some limitations.
56

Identifikation antigener Determinanten des ZPB2 Proteins der Hauskatze und Charakterisierung ihrer kontrazeptiven und immunogenen Eigenschaften

Ringleb, Jennifer January 2004 (has links)
Die immunologische Kontrazeption mittels Zona pellucida (ZP) Proteinen gilt als vielversprechender Ansatz für die Reproduktionskontrolle verwilderter Haus- und Wildtierbestände. Da die Applikation von nativer ZP mit Nebenwirkungen verbunden ist, wird die Verwendung einzelner ZP Peptide als Bestandteil kontrazeptiver Vakzine als besonders aussichtsreich erachtet. Das Prinzip dieser nebenwirkungsfreien ZP Immunisierung ist die gezielte Trennung der Entzündungsreaktionen auslösenden T-Zell-Epitope der ZP von den kontrazeptiv wirkenden B-Zell-Epitopen.<br> Niedermolekulare synthetische oder rekombinante Peptide allein sind gering immunogen und können somit keine ausreichende Immunantwort induzieren. Die Verwendung von Peptiden für die immunologische Kontrazeption erfordert daher ein &bdquo;Vakzin-Design&ldquo;, d. h. die gezielte Kombination der Peptide mit immunstimulierenden Substanzen (Liposomen, Carrierproteinen, Adjuvantien). Zielstellung der vorliegenden Arbeit war die Untersuchung des Potentials synthetischer Peptide für die Immunokontrazeption von verwilderten Hauskatzen (Felis catus). Dazu wurden zunächst relevante B-Zell-Epitope des felinen Zona pellucida Proteins, ZPB2, identifiziert und synthetisiert. Zwei der synthetischen Peptide (P3, P6) wurden zur Herstellung von Antikörpern an BSA konjugiert und zusammen mit Freundschem Adjuvans in Ratten verimpft. Die kontrazeptive Relevanz beider Peptide sowie der Ratten Anti-Peptid Antiseren wurde im in vitro Befruchtungssystem der Hauskatze geprüft. Zur Untersuchung der Immunogenität der Peptide in der Zielspezies Hauskatze erfolgte die Entwicklung von Vakzin-Prototypen für die einmalige Applikation. Neben der Eruierung der Stärke und Dauer der Immunantwort wurde durch Verpaarung der Tiere auch das kontrazeptive Potential in vivo abgeschätzt. / Immunological contraception based on zona pellucida (ZP) proteins is regarded as a promising approach for the control of reproduction in feral domestic and wild animals. Because application of native ZP caused adverse reactions, utilization of single ZP peptides as elements of contraceptive vaccines were considered to bear good prospects. The principle of this ZP immunization is based upon a systematic separation of inflammation triggering T-cell epitopes from the contraceptive B-cell epitopes.<br> The present study evaluates the immunogenicity and contraceptive potential of synthetic feline ZPB2 peptides for immunocontraception in cats (Felis catus). First of all, relevant B-cell epitopes were identified and synthesized. In order to generate antipeptide antibodies two peptides (P3, P6) were chosen and coupled to BSA. Rats were immunized with the conjugation product combined with Freund&prime;s complete adjuvant.<br> The contraceptive efficacy of both peptides and of the anti-peptide antibodies generated were determined using in vitro fertilization of feline oocytes (IVF). To evaluate the peptides immunogenicity in the target species (cat), vaccine-prototypes were developed for a single application protocol. The strength and duration of the immune response was analyzed. Additionally, cats were mated to assess the contraceptive potential of the vaccines in vivo.
57

Echokardiographische Untersuchung der linksatrialen Größe und Funktion bei gesunden Katzen und bei Katzen mit linksventrikulärer Hypertrophie

Maerz, Imke 12 November 2007 (has links) (PDF)
Die Vergrößerung des linken Vorhofes (LA) hat bei Katzen mit Herzerkrankungen eine prognostische Bedeutung und wird mit einem erhöhten Risiko der Entwicklung einer Links-herzinsuffizienz, von supraventrikulären Arrhythmien, von systemischer Thrombembolie und von plötzlichem Herztod in Verbindung gebracht. Bei Katzen mit idiopathischer (HCM) oder sekundärer linksventrikulärer (LV) Hypertrophie kommt es infolge einer LV diastolischen Dysfunktion zu Veränderungen von Größe und Funktion des LA. Ziel der prospektiven Studie war es, die Größe und Funktion des LA in einer Population gesunder Katzen und Katzen mit Kardiomyopathie elektrokardiographisch, radiologisch sowie echokardiographisch zu charakterisieren und die Tiergruppen sowie die diagnostischen Methoden miteinander zu vergleichen. Zur Untersuchung des LA wurden 59 Katzen berücksichtigt. Die Kontrollgruppe bestand aus 26 gesunden Katzen und die Gruppe der kranken Tiere aus 33 Katzen mit HCM oder einer sekundären LV-Hypertrophie. Davon waren 18 Katzen asymptomatisch und 15 hatten eine Linksherzinsuffizienz oder einen aortalen Thrombembolismus. Im EKG wurde die Dauer der P-Welle als diagnostisches Kriterium der LA-Größe untersucht. Bei der radiologischen Untersuchung wurde die Größe des LA in zwei orthogonalen Projektionsebenen subjektiv beurteilt. Außerdem wurde eine neue quantitative Messung des LA im latero-lateralen Strahlengang etabliert. Diese vergleicht die Größe des LA mit der Länge der Thorakalwirbel und wurde als vertebrale Vorhofgröße (LA-VHS) bezeichnet. Mit der transthorakalen zweidimensionalen (2D)- und M-Mode Echokardiographie konnte die Größe des LA durch unterschiedliche Messungen bestimmt werden. Im rechts-parasternalen Vierkammerblick wurden der maximale antero-posteriore Durchmesser des LA (LADs) gemessen und als echokardiographische Bezugsvariable („Gold Standard“) zur Charakterisierung der LA-Größe genutzt. Aus derselben Anschallung wurden die maximale apico-basale Länge des LA und die maximale Vorhoffläche ermittelt. In der rechts-parasternalen Darstellung des LV-Ausflusstraktes wurde unter Anwendung des M-Modes der LA dargestellt und das LA/Ao-Verhältnis berechnet. In der rechts-parasternalen kurzen Achse wurde der maximale Durchmesser des LA (LAmax) bestimmt und sowohl die so genannte „schwedische Methode“ als auch der M-Mode zur Bestimmung der Vorhofgröße und Berechnung der LA/Ao-Verhältnisse angewandt. Der LA wurde als vergrößert definiert, sobald LADs größer 1,60 cm war. Die Ergebnisse der weiteren echokardiographischen Messmethoden zur Charak-terisierung der LA-Größe wurden mit LADs verglichen und folgende Grenzwerte zur Diagnose einer Vergrößerung des LA für die einzelnen unterschiedlichen Messmethoden ermittelt: aus der rechts-parasternalen langen Achse die maximale LA-Länge 1,97 cm, die maximale LA-Fläche 2,80 cm2 und LA/Ao (M-Mode) 1,55, aus der rechts-parasternalen kurzen Achse LA/Ao (M-Mode) 1,54, LA/Ao („schwedische Methode“) 1,44 und LAmax 1,60 cm. Trotz ähnlicher Grenzwerte der LA/Ao-Verhältnisse konnte gezeigt werden, dass die Messwerte der unterschiedlichen Methoden untereinander abweichen und daher diagnostisch nicht austauschbar sind. Die Ergebnisse der elektrokardiographischen und radiologischen Messungen der LA-Größe wurden hinsichtlich ihrer diagnostischen Wertigkeit mit den echokardiographischen Unter-suchungen zur Diagnose einer LA-Vergrößerung verglichen. Das EKG (P-Welle) war wenig sensitiv aber spezifisch bei der Diagnosestellung einer LA-Vergrößerung. Die subjektive radiologische Beurteilung der LA-Größe hatte eine deutlich höhere diagnostische Treffsicherheit, wobei jedoch die Bestimmung der LA-VHS sowohl die größte Sensitivität als auch Spezifität zeigte. Zur Einschätzung der globalen Vorhoffunktion wurden die echokardiographischen Indices LA-Verkürzungsfraktion und LA-Flächenverkürzung herangezogen. Beide Variablen waren in der Gruppe der symptomatischen Katzen deutlich vermindert, verglichen mit der Kontrollgruppe und der Gruppe der asymptomatischen Katzen mit LV-Hypertrophie. Die Reservoirfunktion des LA wurde anhand der S-Welle und des S/D-Verhältnisses des Pulmonalvenenflusses beurteilt. In der Gruppe der symptomatischen Katzen mit LV-Hypertrophie lag das S/D-Verhältnis unter 1,0, was für eine gestörte Reservoirfunktion des LA sprach. Die Weiterleitungsfunktion des LA, charakterisiert durch die D-Welle des Pulmonalvenenflusses war in der Gruppe der symptomatischen Katzen im Gegensatz zu den beiden anderen Gruppen signifikant vermindert. Die Vorhofkontraktion („Booster-Funktion“) wurde anhand der transmitralen A-Welle und der AR-Welle des Pulmonalvenenflusses beurteilt. Hinsichtlich der AR-Welle lag kein Unterschied der Maximalgeschwindigkeit zwischen den drei Tiergruppen vor, jedoch war die Dauer der AR-Welle in der Gruppe der symptomatischen Katzen verlängert. Dieses wurde als Hinweis auf eine erhöhte Nachlast des LA (verminderte LV Dehnbarkeit) und/oder gestörte systolische Funktion des LA gewertet. Die Untersuchung der Blutflussgeschwindigkeit im linken Herzohr zeigte eine deutliche Abnahme in der Gruppe der symptomatischen Katzen und galt als hinweisend für eine gestörte Pumpfunktion und Blutstase. Es wurde ein Zusammenhang zwischen verminderter Blutflussgeschwindigkeit im linken Herzohr (< 0,23 m/s) und dem Risiko eines aortalen Thrombembolismus gefunden. Zusammenfassend kann festgestellt werden, dass eine LV-Hypertrophie bei Katzen zu einer Vergrößerung des LA, verminderter Funktion des LA und Blutstase in LA und im linken Herzohr führt. Somit bestätigt sich die Vermutung, dass der LA sowohl einen diagnostischen als auch prognostischen Wert bei der Untersuchung von Katzen mit HCM oder sekundärer LV-Hypertrophie hat. Die vorliegende Studie liefert einen Beitrag zur echokardiographischen Standarisierung der LA-Größe und LA-Funktion bei der Katze. Weitere Untersuchungen, insbesondere die invasive Validierung echokardiographischer Indices der Größe und Funktion des LA sind notwendig.
58

Sonographische und kernspintomographische Untersuchungen intraokulärer und orbitaler Erkrankungen bei Hund und Katze

Krosigk, Frauke von 05 June 2009 (has links) (PDF)
Das Ziel der vorliegenden Arbeit war es, den klinischen Nutzen der Sonographie und der Magnetresonanztomographie bei intraokulären und orbitalen Erkrankungen bei Hunden und Katzen einzuschätzen und die diagnostische Wertigkeit der bildgebenden Verfahren zu analysieren. Weiterhin wurden charakteristische Befunde einzelner intraokulärer und retrobulbärer Erkrankungen in den bildgebenden Verfahren dargestellt. Die nach der Bildgebung gestellte Diagnose konnte in 67,2% der Fälle durch eine zytologische Untersuchung bestätigt werden. In den restlichen 19,7% der Fälle fand die Diagnose durch die Bildgebung im Zusammenhang mit der Anamnese, Symptomatologie und Therapie statt.
59

Untersuchungen zum Einfluss von Vitamin C und Epigallocatechin-Gallat in Kombination mit Lactoferrin auf die Zahngesundheit bei der Katze

Elsbett, Katrin. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2004--München.
60

Auswirkungen des Opioids Fentanyl auf die neuronale Aktivität visueller Strukturen der Katze und den Serumcortisol-Spiegel unter Allgemeinanästhesie

Grewing, Michaela. Unknown Date (has links) (PDF)
Tierärztl. Hochsch., Diss., 2004--Hannover.

Page generated in 0.0375 seconds