Unicompartmental osteoarthritis of the knee diagnosis and treatment of malignment /

Brouwer, Reinoud Willem. January 2006 (has links)
Proefschrift Erasmus Universiteit Rotterdam. / Thesis Erasmus University Rotterdam. Met lit. opg. - Met samenvatting in het Nederlands. With bibliogr., with a summary in Dutch.
2

Knee immobilization techniques and evaluation /

Veldhuizen, Jan Willem. January 1995 (has links)
Proefschrift Rijksuniversiteit Limburg, Maastricht. / Met lit. opg. - Met een samenvatting in het Nederlands.
3

Perichondrial arthroplasty of the knee

Homminga, George Nicolaas. January 1989 (has links)
Proefschrift Maastricht. / Met lit. opg. - Met een samenvatting in het Nederlands.
4

Perichondrial arthroplasty of the knee results and attempts for improvement since 1986 /

Bouwmeester, Sophia Johannes Maria. January 1999 (has links)
Proefschrift Universiteit Maastricht. / Auteursnaam op omslag: Phianne Bouwmeester. Met lit. opg. - Met samenvatting in het Nederlands.
5

Mittelfristige Ergebnisse (2 - 5 Jahre) nach individueller kreuzbanderhaltender Kniegelenkstotalendoprothetik (Conformis iTotal® CR G2) mit patientenspezifischen Instrumenten und Implantaten / Mid-term results (2 - 5 years) after individual cruciate ligament-retaining total knee arthroplasty (Conformis iTotal® CR G2) with patient-specific instruments and implants

Janßen, Björn January 2021 (has links) (PDF)
Die vorliegende Studie mit insgesamt 73 Patienten untersucht das klinische und funktionelle Outcome nach Implantation einer kreuzbanderhaltenden patientenspezifischen Kniegelenkstotalendoprothese vom Typ Conformis iTotal® CR G2. Es handelt sich um eine monozentrische retrospektive und deskriptive Studie zu klinischen und radiologischen Ergebnissen zwei, drei sowie fünf Jahre postoperativ. Es wurden zu Vergleichszwecken auch präoperative Daten erhoben und ausgewertet. Neben klinischen und radiologischen Untersuchungen wurden durch die Verwendung des „Knee Society Scores“, des „WOMAC Osteoarthritis Index“ und des „SF-12 Health Survey“-Fragebogens die Ergebnisse bezüglich Kniefunktion, Schmerz und Lebensqualität erhoben. Die Untersuchungen für das mittelfristige Outcome erfolgten im Zeitraum zwischen November 2012 und Januar 2017 unter standardisierten Bedingungen. Insgesamt zeigte sich im Vergleich zum präoperativen Ausgangswert eine statistisch signifikante Verbesserung aller erhobenen Scores sowie eine verbesserte Funktionalität. Der Vergleich mit anderen veröffentlichten Studien zeigte eine bessere gesamte Implantationsqualität als bei standardisierten Prothesen. Verglichen mit anderen individualisierten Prothesen sind die Ergebnisse ebenfalls etwas besser bzw. zum Teil gleichwertig. Im Gegensatz zu unserer Studie verbesserten sich die Scores bei den meisten Vergleichsstudien nicht signifikant. Im direkten Vergleich mit den einzelnen Punktzahlen der Scores erzielte die Conformis iTotal® CR G2 Prothese in unserer Studie sehr gute, zum Teil deutlich bessere Ergebnisse. Trotz der sehr guten und vielversprechenden Ergebnisse sollte aufgrund der deutlich aufwendigeren und strahlenbelastenden präoperativen Maßnahmen, die zur Implantation einer solchen Prothese notwendig sind, sowie der teilweise eingeschränkten Aussagekraft dieser Studie weitere Langzeitstudien bezüglich Funktionalität und Haltbarkeit der Conformis iTotal® CR G2 Prothese durchgeführt werden. / This study with a total of 73 patients examines the clinical and functional outcome after implantation of a cruciate ligament-preserving patient-specific total knee joint endoprosthesis of the type Conformis iTotal® CR G2. It is a single-center retrospective and descriptive study of clinical and radiological results two, three and five years postoperatively. For comparison purposes, preoperative data were also collected and evaluated. In addition to clinical and radiological examinations, the results of knee function, pain and quality of life were collected using the “Knee Society Score”, the “WOMAC Osteoarthritis Index” and the “SF-12 Health Survey” questionnaire. The examinations for the medium-term outcome were carried out between November 2012 and January 2017 under standardized conditions. Overall, compared to the preoperative baseline value, there was a statistically significant improvement in all recorded scores and improved functionality. The comparison with other published studies showed a better overall implantation quality than with standardized prostheses. Compared to other individualized prostheses, the results are also slightly better or partly equivalent. In contrast to our study, the scores in most of the comparative studies did not improve significantly. In a direct comparison with the individual scores of the scores, the Conformis iTotal® CR G2 prosthesis achieved very good, in some cases significantly better results in our study. Despite the very good and promising results, further long-term studies regarding the functionality and durability of the Conformis iTotal® CR G2 prosthesis should be carried out due to the significantly more complex and radiation-stressing preoperative measures that are necessary for the implantation of such a prosthesis, as well as the partially limited informative value of this study.
6

Acute knee injuries diagnostic & treatment management proposals /

Casteleyn, Pierre-Paul Hugues Ernest Ghislain. January 1999 (has links)
Proefschrift Universiteit Maastricht. / Met lit. opg. - Met samenvatting in het Nederlands.
7

Die persistierende periprothetische Kniegelenkinfektion - Nutzen der Synovia-Analyse bei einliegendem Zement-Spacer / Persistent Periprosthetic Joint Infection of the Knee - Value of Synovial Analysis with indwelling Spacer

Roth, Magnus Ulrich Maria January 2021 (has links) (PDF)
Der zweizeitige Endoprothesenwechsel gilt als Goldstandard der Therapie periprothetischer Gelenkinfektionen. Ein sicherer Ausschluss einer Infektpersistenz ist für den Therapieerfolg essentiel. Es wurde der diagnostische Nutzen synovialer Marker zum Ausschluss einer Infektpersistenz bei einliegendem Kniegelenksspacer untersucht. Weder mikrobiologische noch zytologische Synovia-Analysen sind zum Ausschluss einer Infektpersistenz im Rahmen des zweizeitigen Knieendoprothesenwechsels geeignet. / Two-stage exchange is considered the gold-standard for therapy of infected joint-arthroplasty. To rule out infection persistence before reimplantation is essential for treatment success. Diagnostic value of synovial markers to rule out infection persistence were evaluated. Neither microbiological nor cytological tests could rule out infection persistence with indwelling pmma-spacer during two-stage-exchange of infected knee-arthroplasty.
8

Does the use of patient-specific instrumentation improve resource use in the operating room and outcome after total knee arthroplasty?: A multicenter study

Beyer, Franziska, Lützner, Cornelia, Stalp, Michael, Köster, Georg, Lützner, Jörg 22 February 2024 (has links)
Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) has been introduced to reduce instruments and surgical time and to improve implant alignment. The aim of this study was to compare TKA with patient-specific and conventional instrumentation with regard to the use of resources in the operating room (OR), alignment and patient-reported outcome. A total of 139 TKA with PSI or conventional instrumentation were included in three centers. Economic variables of the surgery (number of instrument trays, setup and cut-sewtime), radiological alignment and patient reported outcomes (VAS Pain Scale, Oxford Knee Score, EQ-5D) were assessed after 6 weeks, 6 and 12 months. There was a significant reduction of instrument trays and of time in the OR in the PSI group. The reduction varied between the centers. With strict reorganization, more than 50% of the instrument trays could be reduced while using PSI. There were no significant differences in cut-sew-time, implant position, leg axis, pain and function. The use of PSI was associated with significantly less OR resources. However, the savings did not compensate the costs for this technology.
9

Increased inflammatory response is associated with less favorable functional results 5 years after total knee arthroplasty

Lützner, Jörg, Beyer, Franziska, Lützner, Cornelia, Thomas, Peter, Summer, Burkhard 19 March 2024 (has links)
Purpose Allergy against implant materials is discussed controversially and still not fully understood. Despite these controversies, a relevant number of patients receive hypoallergenic knee implants. The aim of this study was to compare a new coating system with the standard implant in total knee arthroplasty (TKA). Additionally, the influence of proinflammatory cytokines on patient-reported outcome measures (PROMs) was investigated. Methods 120 patients without known metal allergy and without previous metal implants were included. The patients were randomized to receive a coated or standard TKA of the same knee system. 105 patients completed the 5 year follow-up. Patient-reported outcome measures (PROMs) including knee function (Oxford Knee Score, OKS), quality of life (SF36) and UCLA activity scale were assessed. Additionally, several cytokines with a possible role in implant allergy were measured in patient`s serum (IL-1beta, IL-5, IL-6, IL-8, IL-10, IP-10, IFN γ, TNF α). Group comparison was performed using Mann–Whitney U test for continuous values and chi-square test for categorical values. Results There were no differences in PROMs between both groups at any follow-up. The majority of patients demonstrated no elevation of the measured blood cytokines. The blood cytokine pattern after 5 years demonstrated no differences between study groups. There was a significant association between elevated IL-8 values and worse results in the overall OKS (p = 0.041), the OKS function component (p = 0.004), the UCLA activity scale (p = 0.007) and the physical component of SF36 (p = 0.001). Conclusion There were no problems with the new coating during mid-term follow-up and no differences in PROMs between coated and standard TKA. Patients with an increased inflammatory response demonstrated worse functional results, regardless of the implant. Level of evidence I. Clinical trial registration The study protocol was registered in the US National Institutes of Health’s database (http:// www.clini caltr ials. gov) registry under NCT00862511.
10

Eine Methode zur Messung der Variabilität des Stabilitätsgrades von Knie-Endoprothesen / A measuring method to determine the variability of the magnitude of equilibrium in knee endoprostheses

Gerstenkamp, Gustav-Ludwig 05 December 2016 (has links)
Eine Methode zur Messung der Variabilität des Stabilitätsgrades von Knie-Endo-prothesen. In dieser Arbeit konnte ein valides Messverfahren für die zwangsfreie Messung der Qualität und Quantität der Stabilitätsgrade von Knieendoprothese anhand der AEQUOS-Knieendoprothese entwickelt werden. Dabei galt es, eine Messanordnung und Methodik zu schaffen, die die Messung der Gleichgewichts-lagen ohne Zwangsführung unter Freischaltung aller Freiheitsgrade ermöglicht. Besondere Berücksichtigung fanden in dieser Arbeit die labilen Zustände, da diese für die dynamischen Übergänge zwischen einzelnen Bewegungen nötig sind. Dazu wurde in der vorliegenden Arbeit die Hauptbewegungsrichtung in der Sagittalebene betrachtet. Um zu simulieren, wie der Roll-Gleitvorgang in der AEQUOS-Prothese durch die Inkongruenz der Gelenkflächen realisiert wird, wurden an der Apparatur kleine Flexionswinkel zwischen 15° und 25° eingestellt, wie sie in der Standphase beim Gehen und auch beim Stand auftreten. Größere Winkel zwischen 35° und 90° wurden den Alltagstätigkeiten wie Bücken, Treppensteigen und Hocken zugeordnet, bis hin zum Vorgang des Aufstehens vom Stuhl bei einem Winkel von 105°. Die Erzeugung von Gleichgewichtszuständen wurde erreicht, indem bei einem festen Flexionswinkel Messungen zu den resultierenden Kräften bei unterschiedlichen Kombinationen der Muskelkräfte durchgeführt wurden. Dabei wurden die Muskelgruppen der Extensorengruppe (M. quadriceps), der Flexoren- oder Hamstring-Gruppe, sowie der M. gastrocnemius und der M. popliteus bei jeder Änderung der Kraftvariante in unterschiedlichem Verhältnis zueinander belastet, um die Kraftvektoren zu variieren. Die Gesamtbelastung wurde dabei mit etwa 63 Kilogramm immer konstant gehalten. Die Einzelgewichte wurden für die entsprechende Muskelgruppe unterschiedlich verteilt. Die kleinen Auslenkungsschritte ermöglichten eine isotonische Messung. Eine Zielsetzung bestand darin, die Möglichkeiten der AEQUOS-Prothese zu simulieren und darzustellen, dass Gleichgewichte ohne äußere Einflussnahme nur durch Muskelaktivität unter der Bedingung des Kraftschlusses eingestellt werden. Es wurde erfolgreich gezeigt, dass der Gleichgewichtszustand und der Stabilitätsgrad im Kniegelenk muskulär geändert werden können wie von Nägerl und Kubein-Meesenburg 1993 postuliert.