• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and development of a new invented doctor blade : Design och utveckling av nyuppfunnet kräppningsblad

Öhrn Sten, Niklas January 2014 (has links)
This report contains the development and construction of a new patented doctor blade. A doctor blade is used when creping soft paper from a large rotating Yankee cylinder. At the current state the doctor blade are in use for four to six hours before it needs to be switch due to wearing, stopping the production of soft paper. The new idea is to have a very long and small blade that will slide into a fixed blade and be continuously pulled when creping paper. The company CS Production had a concept of the fixed blade but wanted to further develop it since the blade was too wide.   Measurements where done with the old blade and with the old testing device to measure the pull force required to pull the blade. New concepts where made by the method of brainstorming and evaluated with an elimination matrix. Rivet joints where selected as the joining technique for the new design. The new concept contains one dominant blade that smaller parts were assembled to form the final blade. The material selected for the dominant blade and the section blade was a cold rolled stainless spring steel strip and for the middle disc the material was aluminum bronze string casted. Test on the pull force required where done with the new doctor blade in the new test rig.  FEM simulation where done on a small part of the blade to see where stresses are occurring in the blade. The FEM result showed that no stresses where on the middle discs, rivets or section blades. This is not reliable results because the small doctor blade is pushing down onto the middle discs and stresses should be occurring on the discs.  Further testing is needed to see if the blade can withstand the forces applied to it.
2

Design and development of a testing device for a new invented Doctor Blade

Sadek, Mohamed January 2013 (has links)
This thesis project is about designing and developing an already existing testing device for a new invented Doctor Blade. A doctor blade is a blade used for creping tissue paper of a rotating cylinder, Yankee Cylinder. The old testing device was incomplete in a way that a rotating cylinder was missing, hence the tested blade is not loaded properly. The old testing device already contained the doctor blade holding device and the pulling device (pulling the creping blade). These two devices are transferred to the new testing device without any redesign within them. The adding of a rotating cylinder/roller required some new redesign regarding the testing device. The main beam (beam carrying all elements) is replaced with a larger one in order to fit the roller and is elongated in order to run longer tests. The new beam has a larger cross section in order to minimize the risk of bending. The main beam is supplied with five small beams, welded onto it, three for attaching the holding device and two for attaching the roller. The dimensions of these small beams are chosen in order to put the roller on the right position according to the creping blade. An electric motor is added to the new testing device in order to drive the roller with a chain. This required two sprockets, one for the motor and one for the roller shaft. The sprockets are chosen with a pitch diameter ratio matching the gearing required. FMEA-analysis is done on the whole design where five failure modes were chosen to be included, bending of the main beam and motor beam, screw joints of the same beams and sprocket-chain mechanism. Some FEM-analysis was required in order to detect the bending of the beams and measuring the loading on the screw joints. The screw joint loading achieved from the FEM-analysis is used for the theoretical screw joint calculations. The FMEA-analysis implied that four of the analyzed failure modes have acceptably low risk factor and dos not require any further actions. However one received a high risk factor, the chain-sprocket mechanism, the risk of clamping fingers. This is solved by adding a protecting house/shell made of sheet metal. Measurements were done on the old and the new testing device regarding the required force for pulling the creping blade and the pressure distribution between the creping blade and the beam (and roller in the new testing device). The improvement of the pulling force values is rather due to the new designed doctor blade than due to the new testing device. The new testing device is however more appropriate than the old one hence the added roller and the tests shows that it is functional as well. / Projektet handlar om design och utveckling av en redan existerande testrigg för ett nyuppfunnet kräppningsblad. Ett kräppningsblad är det bladet som just kräpper av papper från en roterande cylinder, s.k. Yankee Cylinder. Den gamla testriggen var inte komplett och saknade en roterande cylinder, därav kräppningsbladet belastades inte ordentligt. Den gamla testriggen innehöll redan en hållaranordning för kräppningsbladet och en dragstation (som drar kräppningsbladet). Dessa två delar förflyttades till den nya testriggen utan några korrigeringar. Tillägget av en roterande cylinder/vals krävde ny design för den nya testriggen. Huvudbalken (balken som bar alla delar) ersattes av en större balk för att den nya valsen ska få plats. Nya balken är även längre i syfte att kunna köra längre tester. Tvärsnittsarean hos den nya balken är större i syfte att minimera risken för böjning. Fem små balkar är fastsvetsade i den nya huvudbalken, tre för fästning av hållaranordningen och två för fästning av valsen. Placeringen av dessa fem balkar valdes i syfte att placera valsen i rätt position enligt kräppningsbladet. En elektrisk motor tillfördes till den nya testriggen i syfte att driva valsen med en kedja. Detta krävde två nya kugghjul, en för motorn och en för valsaxeln. Delningsdiametern för de två kugghjulen valdes med en viss kvot som motsvarar den utväxlingen som krävs. FMEA-analys utfördes på hela testriggen dör fem olika haveriorsaker inkluderades, böjning av huvudbalken och motorbalken, skruvförbanden på dessa två balkar och till sist kugghjul-kedja mekanismen. FEM-analys krävdes för beräkningar av böjningen på balkarne och för belastningen på skruvförbanden. Belastningen på skruvförbanden uppnåd från FEM-analysen användes senare i de teoretiska beräkningarna av skruvförbanden. FMEA-analysen angav att fyra av de fem analyserade haveriorsakerna har accepterad låg riskfaktor och kräver inga åtgärder. Dock så visade det sig att en haveriorsak fick en för hög risk faktor, kugghjul-kedja mekanismen, risken att klämma fingrar.Detta problem löstes med hjälp av att designa ett skyddshus /skal av plåt. Mätningar gjordes på den gamla och den nya testriggen på dragkrafter och tryckfördelning mellan kräppningsblad och balk (vals i den nya testriggen). Förbättringen av värden på dragkrafterna beror mer av det nydesignade kräppningsbladet än av den nya testriggen. Hursomhelst är den nya testriggen lämpligare än den gamla med tanke på tillförseln av valsen och dessutom så visar testerna att den är funktionell.

Page generated in 0.0728 seconds