• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Alogliptina : caracterização, estudo de compatibilidade, validação de metodologia analítica e estudo de estabilidade para avaliação da qualidade / Alogliptin : characterization, compatibility study, validation of analytical methodology and stability study for quality assessment

Bertol, Charise Dallazem January 2017 (has links)
Alogliptina (ALG) é um hipoglicemiante oral, que inibe a enzima dipeptidil peptidase – 4 (DPP-4) com alta seletividade e aumenta a secreção de insulina prevenindo a hiperglicemia prandial. Como ALG não está descrita nas farmacopeias, este trabalho objetivou caracterizar a matéria-prima (Capítulo I), desenvolver métodos analíticos (Capítulo II) e avaliar sua estabilidade (Capítulo III), auxiliando no controle de qualidade. No capítulo I, a ALG foi caracterizada através de calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (SEM) acoplada a espectrômetro de raios X por dispersão de energia (EDS). A compatibilidade entre a ALG e os excipientes presentes nos comprimidos foi avaliada por DSC, TGA, infravermelho com transformada de Fourier (FTIR), difração de raios-X de pó (XRPD) e microscopia com estágio de aquecimento. ALG apresentou pureza próxima a 99%, com faixa de fusão entre 179,4 e 187,2 °C (pico em 183,3 °C), seguida por decomposição que iniciou em 198,0 °C. Na SEM/EDS, os cristais de ALG mostraram-se predominantemente irregulares e foram detectados traços de impurezas (chumbo e cobre). Alterações na temperatura de fusão da ALG com manitol, estearato de magnésio e nos comprimidos comerciais foram observadas. A microscopia com aquecimento demonstrou que a interação entre manitol e ALG e nos comprimidos é devida à solubilização do fármaco no excipiente fundido, enquanto que na mistura com o estearato de magnésio é devida à fusão do excipiente e do fármaco que ocorrem separadamente, onde o excipiente funde antes que o fármaco. FTIR e XRPD das misturas não detectaram incompatibilidades, somente o aparecimento de bandas adicionais relacionadas aos excipientes. ALG foi compatível com todos os excipientes testados. Estes resultados são importantes para caracterizar, conhecer a estabilidade e a compatibilidade do fármaco. No capítulo II, foram desenvolvidos e validados métodos de cromatografia líquida (LC) indicativos de estabilidade utilizando dois detectores, ultravioleta (UV) e detector de aerossol carregado (CAD) para análise de ALG em comprimidos. Foi utilizada uma coluna C8 (250 mm x 4,6 mm, 5 μm) em modo isocrático, fluxo de 0,8 mL min-1, utilizando acetonitrila e tampão acetato de amônio 10 mM pH 3,5 ajustado com ácido acético (90:10, v/v) como fase móvel e detecção no UV em 275 nm. Os métodos foram lineares no intervalo de 25 - 200 μg mL-1 em ambos os detectores. Os limites de detecção foram de 2,65 e 6,25 μg mL-1 e os de quantificação de 8,84 e 20,85 μg mL-1, respectivamente, para UV e CAD. Os métodos foram precisos e exatos, com desvio padrão relativo menor que 3% e percentuais de recuperação próximos a 100%. Nenhum dos excipientes, ou produtos de degradação interferiu na detecção do fármaco durante os estudos de especificidade. No ensaio de robustez, pequenas alterações no fluxo de fase móvel, pH e concentração de solvente orgânico não afetou significativamente os resultados. O doseamento dos comprimidos obtido com ambos detectores não mostrou diferenças entre si. Os métodos podem ser considerados intercambiáveis e podem ser aplicados como ferramentas para o controle de qualidade de rotina de comprimidos de ALG. No capítulo III foi avaliada a estabilidade térmica da ALG utilizando TGA isotérmica e não isotérmica, e degradação em estufa, analisando as amostras por LC-UV. Na TGA isotérmica a ALG foi submetida a 150, 155, 160, 165, 170 °C, até perda de massa de 10% e os dados foram analisados pelo método de Arrhenius. Na TGA não isotérmica variaram-se as razões de aquecimento, utilizando 2,5, 5,0, 10,0 e 15,0 °C/min até 500 °C. Os dados foram analisados pelo método de Ozawa e de Kissinger. Na degradação em estufa o fármaco foi submetido as temperaturas de 130, 140, 150, 155, 160 e 170 °C. Os parâmetros cinéticos foram obtidos por Arrhenius. ALG segue degradação de zero ordem, onde a velocidade de degradação independe da concentração do reagente. A perda de massa está relacionada à perda química. Os parâmetros cinéticos variaram de acordo com o modelo matemático aplicado. A energia de ativação variou de 26 a 45 kcal/mol. O fármaco degradado demonstrou ser menos tóxico em ensaio de citotoxicidade em células CRIB do que o fármaco não degradado. Os métodos desenvolvidos e a caracterização realizada mostram-se úteis para o adequado controle de qualidade do fármaco. / Alogliptin (ALG) is an oral hypoglycemic agent, which inhibits the enzyme dipeptidyl peptidase - 4 (DPP-4) with high selectivity and increase insulin secretion, preventing postprandial hyperglycemia. ALG is not described in any pharmacopeia. In this context, this study aimed to characterize the active pharmaceutical ingredient (Chapter I), to developed assay methods (Chapter II) and to evaluate the stability (Chapter III), assuring the adequate quality control. In Chapter I, ALG was characterized by differential scanning calorimetry (DSC), thermogravimetry (TGA) and scanning electron microscopy (SEM) coupled with energy dispersive spectrometer X-ray (EDS). The compatibility between ALG and the excipients present in the commercial tablets was evaluated by DSC, TGA, Fourier transform infrared (FTIR), X-ray powder diffraction (XRPD) and hot stage microscopy. ALG presented purity close to 99%, with a melting range between 179.4 to 187.2 °C (peak at 183.33 °C), followed by decomposition which began at 198 °C. In the SEM/EDS the crystals of ALG were predominantly irregulars and it were detected traces of impurities (lead and copper). Alterations in melting temperature of ALG with mannitol, magnesium stearate and in tablets were observed. The hot stage microscopy showed that the interactions between mannitol and ALG and in the tablets were due to the solubilization of the drug in the fused excipient, and in the mixture with magnesium stearate, it was due to the melting of the drug and excipient separately, where the excipient started the melting prior of the drug. FTIR and XRPD of the mixtures did not detect incompatibilities, only the appearance of additional bands related to the excipients. ALG was compatible with all excipients tested. These results are important to characterize, to know the drug stability and compatibility. In Chapter II, liquid chromatography (LC) methods indicative of stability were developed and validated using two detectors, ultraviolet (UV) and charged aerosol detector (CAD) for ALG tablets. It was used a C8 column (250 mm x 4.6 mm, 5 um) in isocratic mode, flow rate of 0.8 ml min-1 using acetonitrile and ammonium acetate buffer 10 mM, pH 3.5 adjusted with acid acetic acid (90:10, v/v) as mobile phase and UV detection at 275 nm. The methods were linear in the range of 25 - 200 μg ml-1 in both detectors. Limits of detection were 2.65 and 6.25 μg mL-1, and of quantification were 8.84 and 20.85 μg mL-1, respectively, for UV and CAD. The methods were accurate and precise, with a relative standard deviation lower than 3% and recovery close to 100%. None of the excipients or degradation products showed interference in the drug detection during specificity studies. In the robustness test, small changes in the mobile phase flow, pH and organic solvent concentration did not significantly affect the results. The results for tablets obtained with both detectors showed no differences. The methods may be considered interchangeable, and they can be used as tools for routine quality control of ALG tablets. In Chapter III the thermal stability of the ALG was evaluated using isothermal and non-isothermal TGA, as well as oven, and samples were analyzed by LC-UV. In the isothermal TGA the ALG was subjected to 150, 155, 160, 165, 170 °C until a mass loss of 10% and the data were analyzed by the Arrhenius method. In non-isothermal TGA the heating rates were varied using 2.5, 5.0, 10.0 and 15.0 °C/min until 500 °C. Data were analyzed by the Ozawa and Kissinger method. In oven the drug was subjected to 130, 140, 150, 155, 160, and 170 °C. The kinetic parameters were obtained by Arrhenius. ALG follows zero-order degradation, where the rate of degradation is independent of the concentration of any reagent. Mass loss is related to chemical reactions. The kinetic parameters varied according to the applied mathematical model. The activation energy ranged from 26 to 45 kcal / mol. The degraded drug was shown to be less toxic in cytotoxicity assay using CRIB cells than the non-degraded drug. The methods developed and the characterization performed proved to be useful for adequate quality control tests of the drug.
2

Alogliptina : caracterização, estudo de compatibilidade, validação de metodologia analítica e estudo de estabilidade para avaliação da qualidade / Alogliptin : characterization, compatibility study, validation of analytical methodology and stability study for quality assessment

Bertol, Charise Dallazem January 2017 (has links)
Alogliptina (ALG) é um hipoglicemiante oral, que inibe a enzima dipeptidil peptidase – 4 (DPP-4) com alta seletividade e aumenta a secreção de insulina prevenindo a hiperglicemia prandial. Como ALG não está descrita nas farmacopeias, este trabalho objetivou caracterizar a matéria-prima (Capítulo I), desenvolver métodos analíticos (Capítulo II) e avaliar sua estabilidade (Capítulo III), auxiliando no controle de qualidade. No capítulo I, a ALG foi caracterizada através de calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (SEM) acoplada a espectrômetro de raios X por dispersão de energia (EDS). A compatibilidade entre a ALG e os excipientes presentes nos comprimidos foi avaliada por DSC, TGA, infravermelho com transformada de Fourier (FTIR), difração de raios-X de pó (XRPD) e microscopia com estágio de aquecimento. ALG apresentou pureza próxima a 99%, com faixa de fusão entre 179,4 e 187,2 °C (pico em 183,3 °C), seguida por decomposição que iniciou em 198,0 °C. Na SEM/EDS, os cristais de ALG mostraram-se predominantemente irregulares e foram detectados traços de impurezas (chumbo e cobre). Alterações na temperatura de fusão da ALG com manitol, estearato de magnésio e nos comprimidos comerciais foram observadas. A microscopia com aquecimento demonstrou que a interação entre manitol e ALG e nos comprimidos é devida à solubilização do fármaco no excipiente fundido, enquanto que na mistura com o estearato de magnésio é devida à fusão do excipiente e do fármaco que ocorrem separadamente, onde o excipiente funde antes que o fármaco. FTIR e XRPD das misturas não detectaram incompatibilidades, somente o aparecimento de bandas adicionais relacionadas aos excipientes. ALG foi compatível com todos os excipientes testados. Estes resultados são importantes para caracterizar, conhecer a estabilidade e a compatibilidade do fármaco. No capítulo II, foram desenvolvidos e validados métodos de cromatografia líquida (LC) indicativos de estabilidade utilizando dois detectores, ultravioleta (UV) e detector de aerossol carregado (CAD) para análise de ALG em comprimidos. Foi utilizada uma coluna C8 (250 mm x 4,6 mm, 5 μm) em modo isocrático, fluxo de 0,8 mL min-1, utilizando acetonitrila e tampão acetato de amônio 10 mM pH 3,5 ajustado com ácido acético (90:10, v/v) como fase móvel e detecção no UV em 275 nm. Os métodos foram lineares no intervalo de 25 - 200 μg mL-1 em ambos os detectores. Os limites de detecção foram de 2,65 e 6,25 μg mL-1 e os de quantificação de 8,84 e 20,85 μg mL-1, respectivamente, para UV e CAD. Os métodos foram precisos e exatos, com desvio padrão relativo menor que 3% e percentuais de recuperação próximos a 100%. Nenhum dos excipientes, ou produtos de degradação interferiu na detecção do fármaco durante os estudos de especificidade. No ensaio de robustez, pequenas alterações no fluxo de fase móvel, pH e concentração de solvente orgânico não afetou significativamente os resultados. O doseamento dos comprimidos obtido com ambos detectores não mostrou diferenças entre si. Os métodos podem ser considerados intercambiáveis e podem ser aplicados como ferramentas para o controle de qualidade de rotina de comprimidos de ALG. No capítulo III foi avaliada a estabilidade térmica da ALG utilizando TGA isotérmica e não isotérmica, e degradação em estufa, analisando as amostras por LC-UV. Na TGA isotérmica a ALG foi submetida a 150, 155, 160, 165, 170 °C, até perda de massa de 10% e os dados foram analisados pelo método de Arrhenius. Na TGA não isotérmica variaram-se as razões de aquecimento, utilizando 2,5, 5,0, 10,0 e 15,0 °C/min até 500 °C. Os dados foram analisados pelo método de Ozawa e de Kissinger. Na degradação em estufa o fármaco foi submetido as temperaturas de 130, 140, 150, 155, 160 e 170 °C. Os parâmetros cinéticos foram obtidos por Arrhenius. ALG segue degradação de zero ordem, onde a velocidade de degradação independe da concentração do reagente. A perda de massa está relacionada à perda química. Os parâmetros cinéticos variaram de acordo com o modelo matemático aplicado. A energia de ativação variou de 26 a 45 kcal/mol. O fármaco degradado demonstrou ser menos tóxico em ensaio de citotoxicidade em células CRIB do que o fármaco não degradado. Os métodos desenvolvidos e a caracterização realizada mostram-se úteis para o adequado controle de qualidade do fármaco. / Alogliptin (ALG) is an oral hypoglycemic agent, which inhibits the enzyme dipeptidyl peptidase - 4 (DPP-4) with high selectivity and increase insulin secretion, preventing postprandial hyperglycemia. ALG is not described in any pharmacopeia. In this context, this study aimed to characterize the active pharmaceutical ingredient (Chapter I), to developed assay methods (Chapter II) and to evaluate the stability (Chapter III), assuring the adequate quality control. In Chapter I, ALG was characterized by differential scanning calorimetry (DSC), thermogravimetry (TGA) and scanning electron microscopy (SEM) coupled with energy dispersive spectrometer X-ray (EDS). The compatibility between ALG and the excipients present in the commercial tablets was evaluated by DSC, TGA, Fourier transform infrared (FTIR), X-ray powder diffraction (XRPD) and hot stage microscopy. ALG presented purity close to 99%, with a melting range between 179.4 to 187.2 °C (peak at 183.33 °C), followed by decomposition which began at 198 °C. In the SEM/EDS the crystals of ALG were predominantly irregulars and it were detected traces of impurities (lead and copper). Alterations in melting temperature of ALG with mannitol, magnesium stearate and in tablets were observed. The hot stage microscopy showed that the interactions between mannitol and ALG and in the tablets were due to the solubilization of the drug in the fused excipient, and in the mixture with magnesium stearate, it was due to the melting of the drug and excipient separately, where the excipient started the melting prior of the drug. FTIR and XRPD of the mixtures did not detect incompatibilities, only the appearance of additional bands related to the excipients. ALG was compatible with all excipients tested. These results are important to characterize, to know the drug stability and compatibility. In Chapter II, liquid chromatography (LC) methods indicative of stability were developed and validated using two detectors, ultraviolet (UV) and charged aerosol detector (CAD) for ALG tablets. It was used a C8 column (250 mm x 4.6 mm, 5 um) in isocratic mode, flow rate of 0.8 ml min-1 using acetonitrile and ammonium acetate buffer 10 mM, pH 3.5 adjusted with acid acetic acid (90:10, v/v) as mobile phase and UV detection at 275 nm. The methods were linear in the range of 25 - 200 μg ml-1 in both detectors. Limits of detection were 2.65 and 6.25 μg mL-1, and of quantification were 8.84 and 20.85 μg mL-1, respectively, for UV and CAD. The methods were accurate and precise, with a relative standard deviation lower than 3% and recovery close to 100%. None of the excipients or degradation products showed interference in the drug detection during specificity studies. In the robustness test, small changes in the mobile phase flow, pH and organic solvent concentration did not significantly affect the results. The results for tablets obtained with both detectors showed no differences. The methods may be considered interchangeable, and they can be used as tools for routine quality control of ALG tablets. In Chapter III the thermal stability of the ALG was evaluated using isothermal and non-isothermal TGA, as well as oven, and samples were analyzed by LC-UV. In the isothermal TGA the ALG was subjected to 150, 155, 160, 165, 170 °C until a mass loss of 10% and the data were analyzed by the Arrhenius method. In non-isothermal TGA the heating rates were varied using 2.5, 5.0, 10.0 and 15.0 °C/min until 500 °C. Data were analyzed by the Ozawa and Kissinger method. In oven the drug was subjected to 130, 140, 150, 155, 160, and 170 °C. The kinetic parameters were obtained by Arrhenius. ALG follows zero-order degradation, where the rate of degradation is independent of the concentration of any reagent. Mass loss is related to chemical reactions. The kinetic parameters varied according to the applied mathematical model. The activation energy ranged from 26 to 45 kcal / mol. The degraded drug was shown to be less toxic in cytotoxicity assay using CRIB cells than the non-degraded drug. The methods developed and the characterization performed proved to be useful for adequate quality control tests of the drug.
3

Alogliptina : caracterização, estudo de compatibilidade, validação de metodologia analítica e estudo de estabilidade para avaliação da qualidade / Alogliptin : characterization, compatibility study, validation of analytical methodology and stability study for quality assessment

Bertol, Charise Dallazem January 2017 (has links)
Alogliptina (ALG) é um hipoglicemiante oral, que inibe a enzima dipeptidil peptidase – 4 (DPP-4) com alta seletividade e aumenta a secreção de insulina prevenindo a hiperglicemia prandial. Como ALG não está descrita nas farmacopeias, este trabalho objetivou caracterizar a matéria-prima (Capítulo I), desenvolver métodos analíticos (Capítulo II) e avaliar sua estabilidade (Capítulo III), auxiliando no controle de qualidade. No capítulo I, a ALG foi caracterizada através de calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (SEM) acoplada a espectrômetro de raios X por dispersão de energia (EDS). A compatibilidade entre a ALG e os excipientes presentes nos comprimidos foi avaliada por DSC, TGA, infravermelho com transformada de Fourier (FTIR), difração de raios-X de pó (XRPD) e microscopia com estágio de aquecimento. ALG apresentou pureza próxima a 99%, com faixa de fusão entre 179,4 e 187,2 °C (pico em 183,3 °C), seguida por decomposição que iniciou em 198,0 °C. Na SEM/EDS, os cristais de ALG mostraram-se predominantemente irregulares e foram detectados traços de impurezas (chumbo e cobre). Alterações na temperatura de fusão da ALG com manitol, estearato de magnésio e nos comprimidos comerciais foram observadas. A microscopia com aquecimento demonstrou que a interação entre manitol e ALG e nos comprimidos é devida à solubilização do fármaco no excipiente fundido, enquanto que na mistura com o estearato de magnésio é devida à fusão do excipiente e do fármaco que ocorrem separadamente, onde o excipiente funde antes que o fármaco. FTIR e XRPD das misturas não detectaram incompatibilidades, somente o aparecimento de bandas adicionais relacionadas aos excipientes. ALG foi compatível com todos os excipientes testados. Estes resultados são importantes para caracterizar, conhecer a estabilidade e a compatibilidade do fármaco. No capítulo II, foram desenvolvidos e validados métodos de cromatografia líquida (LC) indicativos de estabilidade utilizando dois detectores, ultravioleta (UV) e detector de aerossol carregado (CAD) para análise de ALG em comprimidos. Foi utilizada uma coluna C8 (250 mm x 4,6 mm, 5 μm) em modo isocrático, fluxo de 0,8 mL min-1, utilizando acetonitrila e tampão acetato de amônio 10 mM pH 3,5 ajustado com ácido acético (90:10, v/v) como fase móvel e detecção no UV em 275 nm. Os métodos foram lineares no intervalo de 25 - 200 μg mL-1 em ambos os detectores. Os limites de detecção foram de 2,65 e 6,25 μg mL-1 e os de quantificação de 8,84 e 20,85 μg mL-1, respectivamente, para UV e CAD. Os métodos foram precisos e exatos, com desvio padrão relativo menor que 3% e percentuais de recuperação próximos a 100%. Nenhum dos excipientes, ou produtos de degradação interferiu na detecção do fármaco durante os estudos de especificidade. No ensaio de robustez, pequenas alterações no fluxo de fase móvel, pH e concentração de solvente orgânico não afetou significativamente os resultados. O doseamento dos comprimidos obtido com ambos detectores não mostrou diferenças entre si. Os métodos podem ser considerados intercambiáveis e podem ser aplicados como ferramentas para o controle de qualidade de rotina de comprimidos de ALG. No capítulo III foi avaliada a estabilidade térmica da ALG utilizando TGA isotérmica e não isotérmica, e degradação em estufa, analisando as amostras por LC-UV. Na TGA isotérmica a ALG foi submetida a 150, 155, 160, 165, 170 °C, até perda de massa de 10% e os dados foram analisados pelo método de Arrhenius. Na TGA não isotérmica variaram-se as razões de aquecimento, utilizando 2,5, 5,0, 10,0 e 15,0 °C/min até 500 °C. Os dados foram analisados pelo método de Ozawa e de Kissinger. Na degradação em estufa o fármaco foi submetido as temperaturas de 130, 140, 150, 155, 160 e 170 °C. Os parâmetros cinéticos foram obtidos por Arrhenius. ALG segue degradação de zero ordem, onde a velocidade de degradação independe da concentração do reagente. A perda de massa está relacionada à perda química. Os parâmetros cinéticos variaram de acordo com o modelo matemático aplicado. A energia de ativação variou de 26 a 45 kcal/mol. O fármaco degradado demonstrou ser menos tóxico em ensaio de citotoxicidade em células CRIB do que o fármaco não degradado. Os métodos desenvolvidos e a caracterização realizada mostram-se úteis para o adequado controle de qualidade do fármaco. / Alogliptin (ALG) is an oral hypoglycemic agent, which inhibits the enzyme dipeptidyl peptidase - 4 (DPP-4) with high selectivity and increase insulin secretion, preventing postprandial hyperglycemia. ALG is not described in any pharmacopeia. In this context, this study aimed to characterize the active pharmaceutical ingredient (Chapter I), to developed assay methods (Chapter II) and to evaluate the stability (Chapter III), assuring the adequate quality control. In Chapter I, ALG was characterized by differential scanning calorimetry (DSC), thermogravimetry (TGA) and scanning electron microscopy (SEM) coupled with energy dispersive spectrometer X-ray (EDS). The compatibility between ALG and the excipients present in the commercial tablets was evaluated by DSC, TGA, Fourier transform infrared (FTIR), X-ray powder diffraction (XRPD) and hot stage microscopy. ALG presented purity close to 99%, with a melting range between 179.4 to 187.2 °C (peak at 183.33 °C), followed by decomposition which began at 198 °C. In the SEM/EDS the crystals of ALG were predominantly irregulars and it were detected traces of impurities (lead and copper). Alterations in melting temperature of ALG with mannitol, magnesium stearate and in tablets were observed. The hot stage microscopy showed that the interactions between mannitol and ALG and in the tablets were due to the solubilization of the drug in the fused excipient, and in the mixture with magnesium stearate, it was due to the melting of the drug and excipient separately, where the excipient started the melting prior of the drug. FTIR and XRPD of the mixtures did not detect incompatibilities, only the appearance of additional bands related to the excipients. ALG was compatible with all excipients tested. These results are important to characterize, to know the drug stability and compatibility. In Chapter II, liquid chromatography (LC) methods indicative of stability were developed and validated using two detectors, ultraviolet (UV) and charged aerosol detector (CAD) for ALG tablets. It was used a C8 column (250 mm x 4.6 mm, 5 um) in isocratic mode, flow rate of 0.8 ml min-1 using acetonitrile and ammonium acetate buffer 10 mM, pH 3.5 adjusted with acid acetic acid (90:10, v/v) as mobile phase and UV detection at 275 nm. The methods were linear in the range of 25 - 200 μg ml-1 in both detectors. Limits of detection were 2.65 and 6.25 μg mL-1, and of quantification were 8.84 and 20.85 μg mL-1, respectively, for UV and CAD. The methods were accurate and precise, with a relative standard deviation lower than 3% and recovery close to 100%. None of the excipients or degradation products showed interference in the drug detection during specificity studies. In the robustness test, small changes in the mobile phase flow, pH and organic solvent concentration did not significantly affect the results. The results for tablets obtained with both detectors showed no differences. The methods may be considered interchangeable, and they can be used as tools for routine quality control of ALG tablets. In Chapter III the thermal stability of the ALG was evaluated using isothermal and non-isothermal TGA, as well as oven, and samples were analyzed by LC-UV. In the isothermal TGA the ALG was subjected to 150, 155, 160, 165, 170 °C until a mass loss of 10% and the data were analyzed by the Arrhenius method. In non-isothermal TGA the heating rates were varied using 2.5, 5.0, 10.0 and 15.0 °C/min until 500 °C. Data were analyzed by the Ozawa and Kissinger method. In oven the drug was subjected to 130, 140, 150, 155, 160, and 170 °C. The kinetic parameters were obtained by Arrhenius. ALG follows zero-order degradation, where the rate of degradation is independent of the concentration of any reagent. Mass loss is related to chemical reactions. The kinetic parameters varied according to the applied mathematical model. The activation energy ranged from 26 to 45 kcal / mol. The degraded drug was shown to be less toxic in cytotoxicity assay using CRIB cells than the non-degraded drug. The methods developed and the characterization performed proved to be useful for adequate quality control tests of the drug.
4

Spårmängdsanalys av explosivämnen

Loorents, Cheryl January 2020 (has links)
There is an alarming increase of explosions with devastating consequences, the ultimate being loss of life. Furthermore, these kinds of substances have a toxic effect on animals, nature and humans if they are incorrectly disposed. In order to counteract the rising trend and increase the feeling of security within the society, the Swedish Defense Research Agency (FOI) has started a new project which in the future might be used by the police in order to prevent possible terrorist attacks. The aim with this new project is to perform trace analysis of explosives in wastewater in order to receive an indication of where illegal production of explosives takes place. This method has the potential to be used for other matrixes, such as soil instead of wastewater or other water matrixes, thereby exposing possible harmful and contaminated places.   The aim with this thesis was to develop a method for an Ultra-High-Performance Liquid Chromatography (UHPLC) instrument in order to perform trace analysis of explosives in wastewater. Furthermore, the aim was also to develop a method for an automated solid phase extraction (SPE) instrument for sample clean-up. Lastly mass spectrometry was performed with a triple-quadrupole. A performance analysis was made for the developed UHPLC-method which resulted in a good repeatability. Furthermore, several experiments were conducted on the SPE-instrument in order to receive a yield close to 100%. The different experiments included comparison between the most beneficial eluent, volume of eluent and evaporation step. The highest yield was received with 3 ml acetonitrile without any evaporation step. A performance analysis was made of the developed method for the SPE-robot, which resulted in a good accuracy and precision. In hopes of lowering the detection limit, mass spectrometry was conducted by a preciously validated instrument based at FOI. A lower detection limit was received for all substances; R-salt 0,025 µg/ml, TNT 0,094 µg/ml and PETN 0,103 µg/ml.
5

Cannabidiol Extraction and Quantification: A Comparison of Four Solvent Based Extraction Methods in Gummy Matrices

Biggie, Katherine 10 May 2023 (has links)
No description available.
6

Cartographie génétique des composés phénoliques de la pomme

Verdu, Cindy 11 July 2013 (has links) (PDF)
En lien avec leur potentiel antioxydant, les composés phénoliques sont généralement associés à l'effet protecteur sur la santé d'une alimentation riche en fruits et légumes. Ils sont également fortement associés à la qualité organoleptique des cidres puisqu'ils affectent directement leur astringence, leur amertume, leur couleur et leurs arômes. Deux études ont récemment été publiées sur la détection de QTL des composés phénoliques des pommes de table. Aucune étude n'a encore été publiée pour les pommes à cidre, réputées pour leur forte teneur en composés phénoliques. L'objectif de cette thèse est d'identifier les régions génétiques impliquées dans la teneur en composés phénoliques d'une descendance de pommiers à cidre. Dans un premier temps, deux méthodes de quantification ont été développées et comparées en UHPLC-UV et UHPLC-MS/MS pour les principaux composés phénoliques du jus de pomme. Bien qu'il y ait des surestimations avec l'un des détecteurs pour certains composés, ces deux méthodes corrèlent très fortement. Des dosages ont également été réalisés sur fruit entier à l'INRA de Rennes. Une grande variabilité a été observée pour les fruits et les jus de cette descendance, représentative des principales variétés de pommes à cidre cultivées en Europe. 48 QTL ont été détectés sur neuf groupes de liaison (LG). Neuf clusters semblent particulièrement stables, indépendamment de l'année ou du matériel (fruit ou jus) étudié. Les enzymes de la biosynthèse des composés phénoliques et facteurs de transcription ont été ciblés pour l'identification des gènes candidats, réalisée au niveau des principaux QTL. Ces travaux proposent de nouvelles cibles pour la sélection assistée par marqueurs comme le QTL pour l'acide chlorogénique du LG17 pour l'amélioration des variétés de pommes à cidre

Page generated in 0.0279 seconds