• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 120
  • 23
  • 12
  • 11
  • 6
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 417
  • 196
  • 99
  • 92
  • 90
  • 87
  • 72
  • 71
  • 69
  • 63
  • 60
  • 53
  • 50
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Tratamento biológico de líquidos percolados de aterros sanitários utilizando reator anaeróbio horizontal de leito fixo (RAHLF) / Biological treatment of sanitary landfill leachate using a horizontal anaerobic immobilized sludge reactor

Ronan Cleber Contrera 12 May 2003 (has links)
Ainda são poucas as cidades brasileiras que dão destino adequado aos seus resíduos sólidos urbanos. A disposição de resíduos em aterros sanitários é hoje uma das formas mais econômicas e adequadas de disposição. A grande quantidade de matéria orgânica presente nos resíduos domiciliares, a umidade própria dos resíduos, a infiltração de águas de chuvas e as atividades microbiológicas, faz com que se gere no interior dos aterros os líquidos percolados. Esses líquidos apresentam elevada demanda química de oxigênio (DQO) e são potencialmente poluidores. Este trabalho avaliou a eficiência e a viabilidade da utilização de um reator anaeróbio horizontal de leito fixo (RAHLF), no tratamento de líquidos percolados coletados nos aterros sanitários de Bauru-SP e Rio Claro-SP. O reator, em escala piloto, constituiu-se de um tubo de PVC com 3,0 m de comprimento e 14,5 cm de diâmetro interno, perfazendo uma relação comprimento por diâmetro (L/D) de aproximadamente 20 e volume de aproximadamente 50 L. O reator possuía coletor de gases e amostradores intermediários ao longo do comprimento, em posições correspondentes a L/D de 4, 8, 12 e 16. Como suporte de imobilização foi utilizada espuma de poliuretano com densidade de 20 kg.m-3 na forma de cubos de aproximadamente 10 mm de lado. Os percolados foram coletados e armazenados em uma câmara fria a 5ºC e o reator foi mantido com temperatura controlada em uma câmara a 30ºC. Ao se operar o sistema por oito semanas, com o percolado coletado em Bauru-SP, não houve adaptação da biomassa devido, provavelmente, às altas concentrações de NH3. Utilizando o percolado de Rio Claro-SP, o sistema apresentou inicialmente baixas eficiências, mesmo com tempo de detenção hidráulica de 25 dias. Mas após mudanças na estratégia de operação, utilizando-se um substrato sintético na adaptação e a substituindo-se o percolado por outro coletado no mesmo aterro, o sistema reagiu muito bem, obtendo-se eficiências de aproximadamente 80% em termos de remoção de DQO, com tempo de detenção hidráulica de 2,5 dias e com DQO afluente da ordem de 5.000 mg/L. / Even today, only few Brazilian cities give adequate destiny to urban solid wastes. The waste disposal at sanitary landfills is currently one of the most economical and adequated way of waste disposal. The high quantity of organic matter in domiciliary wastes, the waste own moisture, the rainwater infiltration and the microbiological activities lead to the leachate generation into the landfill. This liquid has a high chemical oxygen demand (COD) concentration, and is a potential pollutant. This work evaluated the viability and the efficiency of the use of a horizontal anaerobic immobilized sludge reactor (HAIS reactor) for leachate treatment collected from Bauru-SP and Rio Claro-SP landfills. The reactor, in pilot scale, was constructed using a 3,0 m of length and 14,5 cm internal diameter PVC pipe, with a length-diameter ratio (L/D) of approximately 20, and an approximately 50 L volume. The reactor had gas collectors and intermediate samplers in the direction of its length, in positions corresponding to L/D equal to 4, 8, 12 and 16. For immobilization support it was utilized polyurethane foam with 20 kg.m-3 of density in cube form, with side of approximately 10 mm. The leachate was collected and stored in a cold chamber at 5ºC and the reactor was maintained at controlled temperature in a chamber at 30ºC. Operating the system with the leachate from Bauru-SP during eight weeks, there was no biomass acclimatization due, probably, to high NH3 concentrations. When utilizing the leachate from Rio Claro-SP the system had, initially, low efficiencies, even with a hydraulic retention time of 25 days. But after changes in the operation strategy, changing the leachate by one other collected in the same place, the system reacted very well, obtaining efficiencies of approximately 80% in terms of COD removal, with a hydraulic retention time of 2,5 days and an inlet COD at the range of 5.000 mg/L.
322

Estudo da atenuação dos contaminantes de líquidos percolados no solo / Study the pollutants attenuation of the leachate in the soil

Tania Leme de Almeida 23 March 2005 (has links)
A maioria dos municípios brasileiros dispõe os resíduos sólidos domiciliares em locais a céu aberto, sem controle e critério, contribuindo para a poluição das águas superficiais e do lençol freático. Estudos da contaminação de solos e seus mecanismos são cada vez mais explorados devido à necessidade de segurança, a longo prazo, exigida para sistemas de contenção de resíduos. A movimentação de chorume dos aterros para os solos, águas superficiais e subterrâneas coloca em risco a saúde pública pela contaminação. Estudos recentes constataram a existência de processos que permitem a atenuação natural dos contaminantes presentes nestes percolados. O adequado entendimento destes processos pode dar origem a uma série de benefícios possíveis de serem aplicados em aterros antigos, novos ou naqueles que ainda serão concebidos. O presente trabalho avaliou a atenuação de contaminantes, presentes no chorume, pelo solo por meio de experimento desenvolvido em colunas de percolação. O chorume e o solo utilizados neste experimento são provenientes do aterro sanitário de São Carlos - SP. O solo utilizado foi caracterizado quanto à composição físico-química para verificar o transporte do percolado nas colunas e a interação solo-contaminante. As curvas características do transporte de contaminantes traçadas apresentaram baixas concentrações de Pb (Chumbo), Cd (Cádmio), Fe (Ferro), Zn (Zinco) e Mn (Manganês) nas amostras efluentes. Já o Na (Sódio), K (Potássio), Cl (Cloro), Ni (Níquel) e Cu (Cobre) foram preferencialmente lixiviados com o chorume percolante, evidenciando a variação da faixa de concentração de cada elemento no percolado. Os perfis de concentração dos metais pesados mostraram que existe uma frente de contaminação, apresentando uma relação entre a concentração do metal sorvido no solo e sua concentração no percolado. As curvas de retenção de metais no solo mostraram que o Cd, Pb, Cr, Cu e Mn foram preferencialmente sorvidos no solo em relação ao Fe, Zn e Ni. O solo em questão apresentou bom potencial para retenção dos contaminantes presentes no chorume, apesar de ser classificado como arenoso e de suas características químicas não se enquadrarem nos parâmetros adequados para sua utilização em áreas de disposição de resíduos sólidos urbanos. Seu uso em base de aterros sanitários de pequeno porte pode ser considerado, desde que suas características sejam melhoradas por meio da mistura com geossintéticos. Este procedimento acarreta certa economia na construção de camadas impermeabilizantes, pois dispensa o uso de argilas e evita seu transporte de locais distantes do aterro. / The most of brazilian municipal cities disposes solid waste in places at opened sky, without control and criterion, contributing to the pollution of the surface and groundwater. Studies concerning soil contamination and their mechanisms have been explored more and more due to the long term security requirements demanded for residue containment systems. The movement of leachate from the landfill to the soils, surface and groundwaters put on risk the public health because of the contamination. Recent studies verify the existence of processes that allow the attenuation in natural way of the present pollutants in these leachates. The appropriate understanding of these processes propitiates a series of possible benefits of they be applied in old landfill, new or in those that will be implanted. The present work evaluated the attenuation of pollutants, presents in the leachate by the soil through experiment developed in percolation columns. The leachate and soil used in this experiment have came from the sanitary landfill of São Carlos - SP. The collected soil was characterized as to composition physical-chemical to verify the transport of the leachate in the columns and the interaction soil-pollutant. The breakthrough curves traced have been observed that Pb (Lead), Cd (Cadmium), Fe (Iron), Zn (Zinc) and Mn (Manganese) came in low concentration in the effluents leachate. Already the Na (Sodium), K (Potassium), Cl (Chlorine), Ni (Nickel) and Cu (Copper) have been preferably leached with the leachate, showing occurrence of a wide range of concentrations of each species at leachate. Concentration profiles of the heavy metals indicated the existence of a contamination plume, showing relationship between concentration of the metal absorved in the soil and in the leachate. The curves of material´s retention for the soil showed that the Cd, Pb, Cr, Cu and Mn were preferably absorved by the soil in relation to the Fe, Zn and Ni. The soil in subject has presented good potential of retention for the present pollutants in the leachate in spite of being classified as sandy and they chemical characteristics don\'t frame in the appropriate parameters for use in areas of solid waste disposal. Your use in base of sanitary landfill of small load can be considered, since your characteristics have been improved through the mixture of this soil with geo synthetics, involving certain economy at construction of waterproof layers, exempting the clay use and avoid the transport of this material for distant places of the landfill.
323

Efeito da variação gradual da taxa de recirculação do lixiviado em reatores anaeróbios híbridos na digestão da fração orgânica dos resíduos sólidos urbanos / Effect of the gradual variation of the leachate recirculation rate in hybrid anaerobic reactors treating the organic fraction of municipal solid wastes

Gabriel D'Arrigo de Brito Souto 09 June 2005 (has links)
O presente estudo teve por finalidade testar a hipótese de que o uso de uma taxa de recirculação variável do lixiviado de um reator tratando a fração orgânica dos resíduos sólidos urbanos domésticos, em um sistema em batelada híbrido, seria capaz de acelerar a degradação deste substrato em comparação com um sistema idêntico, porém que operasse com taxa de recirculação constante. Dois conjuntos de reatores foram operados, um com taxa de recirculação constante (sistema controle) e o outro com taxa de recirculação variável (sistema experimental). Os reatores foram mantidos em sala climatizada, com temperatura mantida em 35 ºC '+ OU -' 1 ºC. Cada conjunto era composto de um reator de sólidos, preenchido com o resíduo a ser digerido misturado a lixiviado de aterro sanitário, e um filtro anaeróbio, destinado a tratar o lixiviado que saía do primeiro. O substrato utilizado foi a fração orgânica dos resíduos sólidos urbanos domésticos padronizada (FORSUDp). Diversas variáveis foram medidas para o acompanhamento do processo: DQO de amostras filtradas e não filtradas, alcalinidade total, alcalinidade a ácidos voláteis, série de sólidos, nitrogênio total Kjeldahl e amoniacal, fósforo total, ácidos voláteis e composição do biogás por cromatografia gasosa. Também se acompanhou o desenvolvimento da microbiota anaeróbia por microscopia óptica de contraste de fase e fluorescência. A microscopia eletrônica de varredura indicou desenvolvimento de biofilme no meio suporte dos filtros anaeróbios. Concluiu-se que a taxa de recirculação variável consegue acelerar o processo, além de alterar de forma significativa o comportamento dos reatores e a forma de interação entre os mesmos / The objective of this study was to test the following hypothesis: varying the leachate recirculation rate in a hybrid batch reactor would make it possible to shorten the time required for the digestion of MSW, in comparison to a similar system operating with constant recirculation rate. Two sets of reactors were operated, one with constant recirculation rate (control system) and the other with varying rate (experimental system). The reactors were kept in a room which internal temperature was controlled. The temperature was kept at 35 ºC '+ OU -' 1ºC. Each set of reactors was composed of a solids reactor, filled with solid wastes and inoculated with landfill leachate, and an anaerobic filter, that should treat the leachate form the first one. The substract used was the standardized organic fraction of the municipal solid wastes (FORSUDp). Several parameters were measured for process monitoring: COD (in filtered and not filtered samples), total alkalinity, volatile acids alkalinity, solids, Kjeldahl nitrogen, ammonium nitrogen, total phosphorus, volatile acids by gas chromatography and biogas composition. The development of the anaerobic microorganisms was observed with phase-contrast and fluorescence microscopy. Scanning electron microscopy of the packed bed media showed biofilm development. It was concluded that the varying leachate recirculation rate proved to be able to enhance the degradation process. Besides, this operational strategy entirely changed the behaviour and interaction of the reactors
324

Ozonização catalítica do chorume proveniente do antigo aterro controlado da cidade de Guaratinguetá-SP utilizando os íons Fe2+, Fe3+, Zn2+, Mn2+, Ni2+ e Cr3+ / Homogeneous catalytic ozonation of leachate from Guaratinguetá - SP landfill, using the ions Fe2+, Fe3+, Zn2+, Mn2+, Ni2+ e Cr3+

André Luís de Castro Peixoto 14 May 2008 (has links)
Durante anos, o lixo da cidade de Guaratinguetá foi aterrado e o seu produto recalcitrante não passou por nenhum tratamento físico ou mesmo químico, percolando diretamente sob o aterro. Mesmo tendo sido desativado e transformado em Parque Ecológico, o material depositado no local ao longo dos anos, continuará a ser decomposto por microrganismos e continuará a ser produzido o lixiviado como fonte de poluição ambiental. Inicialmente, fez-se a caracterização do chorume \"in natura\", demonstrando-se como fonte de matéria orgânica recalcitrante, com massa molar característica de macromoléculas (5,58 kDa e polidispersidade de 1,16), DBO não determinável pela recalcitrância molecular e/ou pela ação tóxica e DQO característica de lixiviado estabilizado (1.013 mg L-1). A fração inorgânica total, dada pela quantidade de sólidos fixos, foi de 3.670 mg L-1, valor esse 3,6 vezes maior que a fração orgânica. O estudo de tratamento do chorume, por ozonização catalítica homogênea foi desenvolvido, principalmente, pelo uso seqüencial de dois arranjos ortogonais de Taguchi, sendo o primeiro, matriz L16, para estudo exploratório dos fatores mais importantes na redução percentual da DQO. Os fatores estudados foram vazão de ozônio, concentração dos íons Fe2+, Fe3+, Zn2+, Mn2+, Ni2+ e Cr3+, pH do meio reacional e presença/ausência de fonte de radiação UV (254 nm). Dentre os metais de transição, os íons Fe2+ e Fe3+ demonstraram-se como mais viáveis como catalisadores na geração de radicais livres hidroxilas devido à sua significância estatística (p = 0,005), e por terem maior tolerância ao descarte no meio ambiente (menor toxicidade) frente aos demais íons. Com a utilização do arranjo ortogonal L8 de Taguchi, foi possível atingir degradação máxima de DQO da ordem de 50 %. A melhor configuração dos fatores, visando aumentar o percentual de redução da DQO foi: vazão de ozônio igual a 5 L h-1 (589,9 mg h-1 O3), concentração de íon de íon ferroso igual a 10 mg L-1, concentração de íon férrico igual a 5 mg L-1 e pH 5. / During many years, the garbage of Guaratinguetá city was landfilled and its recalcitrant product was not submitted to any physical or chemical treatment, leaching directly through the area. After deactivating and transforming the landfill into an Ecological Park, the material deposited in the place by the past years, will continue being decomposed by microorganisms and will continue producing the leached one as a mean of environment pollution. Initially, the leachate \"in natura\" was characterized, demonstrating itself as a source of recalcitrant organic substance with a higher molecular size characteristic of 5,58 kDa and polidispersity of 1,16 and stabilized effluent (not determinable DBO due to molecular recalcitrance and/or toxicity and DQO of 1,013 mg L-1). The total inorganic fraction, given by the amount of total fixed solids was 3,670 mg L-1, which means 3,6 times bigger than the organic fraction. The study of leachate treatment by homogeneous catalytic ozonation was given, mainly, for the sequential use of two Taguchi\'s orthogonal arrangements, being the first, L16 design, for exploratory studies of the most important factors in the percentual reduction of DQO. The factors studied were the ozone outflow, the Fe2+, Fe3+, Zn2+, Mn2+, Ni2+ and Cr3+ ions concentration, the reaction medium pH and the presence/absence of UV radiation source UV (254 nm). Amongst the transition metals, Fe2+ and Fe3+ ions have demonstrated to be as more viable as free hydroxyl radicals catalyst due to its statistics significance (p = 0,005) and also because they have a greater tolerance to the environment discarding (less toxicity) compared to the other ions. The use of L8 Taguchi\'s orthogonal arrays gives the possibility to reach 50 % maximum COD depletion. The best factors configuration, using COD percentage reduction as experimental design response was: 5 L h-1 (589,9 mg h-1 O3) ozone outflow, 10 mg L-1 ferrous concentration, 5 mg L-1 ferric ion concentration and pH 5.
325

Model energetskog iskorišćenja deponijskog gasa na deponijama sa recirkulacijom koncentrata i procedne vode / Model of landfill gas energy utilization at landfills with concentrate and leachate recirculation

Džolev Nikola 29 September 2018 (has links)
<p>Deponijski gas koji nastaje kao rezultat anaerobnih procesa unutar<br />otpada na deponiji može da se iskoristi kao obnovljivi izvor<br />energije, smanjujući ujedno i zagađenje vazduha. Tretman procedne vode<br />u savremenim postrojenjima za prečišćavanje reverznom osmozom daje<br />neželjeni ostatak &ndash; koncentrat, koji se uobičajeno recirkuliše na<br />deponiju kao vid tretmana. Ova disertacija se bavi uticajem<br />recirkulacije na produkciju deponijskog gasa, kako bi se omogućila<br />bolja upravljivost i predikcija čitavog procesa upravljanja otpadom<br />sa ciljem održanja stabilne proizvodnje deponijskog gasa i povećanja<br />mogućnosti njegovog iskorišćenja u termo-energetskim postrojenjima.</p> / <p>Landfill gas resulting from the anaerobic processes in the waste at the landfill<br />can be used as a renewable energy source, reducing both air<br />pollution. Treatment of leachate in modern plants for the purification using<br />reverse osmosis gives unwanted residue - concentrate, which is typically<br />recirculated back to the landfill as a form of its treatment. This thesis deals<br />with the influence of recirculation in the production of landfill gas, to allow for<br />better handling and prediction of entire process of waste management in<br />order to maintain stable production of landfill gas and increasing<br />opportunities for its utilization in thermal and power plants.</p>
326

Lixiviado de aterros sanitários brasileiros: estudo de remoção do nitrogênio amoniacal por processo de arraste com ar (\"stripping\") / Sanitary landfill leachate in Brazil: evaluation of ammonia nitrogen removal by air stripping process

Souto, Gabriel D\'Arrigo de Brito 09 January 2009 (has links)
Aterros sanitários são a forma mais viável de disposição final dos resíduos sólidos urbanos no Brasil, tanto do ponto de vista técnico quanto econômico. Os antigos lixões estão sendo progressivamente substituídos por aterros bem projetados e operados. Entretanto, os aterros ainda representam risco ambiental devido à liberação de gases e produção de lixiviado (chorume). Os gases podem ser canalizados e queimados ou usados para produção de energia. O tratamento do lixiviado, porém, ainda representa um desafio aos profissionais da área, não tendo ainda sido encontrada uma solução eficaz. As próprias características físico-químicas deste efluente não são bem conhecidas. No presente trabalho buscou-se contribuir para a solução do problema mediante estudos em três frentes: a caracterização detalhada do lixiviado de aterros brasileiros, o estudo da remoção da amônia (o principal poluente presente no lixiviado) por arraste com ar e a importância da força iônica. A compilação de dados referentes a 40 aterros, distribuídos em todas as regiões do país, possibilitou a elaboração de tabelas com as características típicas do lixiviado durante as fases ácida e metanogênica dos aterros. Não se apresentou apenas os valores extremos de cada variável, mas também as faixas mais prováveis de variação. Também foi possível concluir que a fase ácida na maior parte dos casos não dura mais que dois anos nos aterros brasileiros, desde que esses sejam dotados de sistemas de drenagem de base. O estudo do arraste de amônia foi efetuado em torres de 15 cm de diâmetro e 1 m de altura útil, usando-se anéis de polietileno corrugado como material de recheio. Os resultados mostraram que torres aeradas permitem a remoção praticamente total do nitrogênio amoniacal, independentemente de se fazer ou não alcalinização prévia do lixiviado. O volume de ar necessário para remover uma determinada massa de amônia é sempre constante. Somente foi observada nitrificação quando as concentrações de nitrogênio amoniacal ficaram abaixo de 50 mg/L. A elevada força iônica do lixiviado pode ser a responsável pelo fraco desempenho do processo de coagulação-floculação quando aplicado a este efluente. A força iônica é um aspecto pouco estudado no âmbito da engenharia sanitária e ambiental, mas que não pode ser desconsiderada nos estudos acerca do lixiviado. Outros aspectos foram investigados, como o efeito do cloreto na DQO (demanda química de oxigênio) e a possibilidade de desenvolvimento de larvas de insetos nas lagoas de lixiviado. / Sanitary landfills are considered as the most appropriate way for final disposal of municipal solid wastes in Brazil, in the technical and economical point of view. Open dumps have been progressively substituted by well engineered and operated landfills. However, landfills still present environmental risks due to the gas emission and leachate production. Gases can be piped and burnt or used to the electricity production, but the same can not be applied to the leachate. Moreover, the leachate treatment still represents a challenge to the expertise of the area because it was not already found an efficient solution for it. The physical-chemical characteristics of this effluent are not well known yet. This research sought to contribute to the solution of this problem by focusing in three main lines: detailed characterization of the leachate of Brazilian landfills, investigation of the possibilities of ammonia removal (the main pollutant present in the leachate) by air stripping process and evaluation of the importance of the ionic strength. The compilation of data from 40 sanitary landfills, distributed in all the geographic regions of Brazil, allowed the preparation of tables describing the typical characteristics of Brazilian leachates during the acid and methanogenic phases. It was presented not only the extreme values, but also the most probable ranges of variation. It was also possible to conclude that the acid phase lasts no more than 2 years in Brazilian landfills equipped with adequate leachate drainage systems. The study of ammonia air stripping was carried out in towers of 15 cm of diameter and 1 m of packed bed height. Corrugated plastic Raschig rings were used as packing media. Results showed that the aerated towers were able to remove the ammonia almost completely, independently if the pH of leachate was previously increased or not. The volume of air necessary to remove a determined mass of ammonia is always constant. Nitrification occurred only when total ammonia nitrogen concentrations were lower than 50 mg/L. This led to the conclusion that biological systems should not be applied directly to the treatment of raw methanogenic leachate. The high ionic strength of the leachate can be the responsible for the low efficiencies of coagulation-flocculation process applied to this effluent. Even though ionic strength is not usually considered by sanitary and environmental engineering, it should be considered in the studies dealing with leachate. Other aspects were also investigated, as the effect of the chloride in COD (chemical oxygen demand) measurements and the possibility of maggots growth in leachate ponds.
327

Variação da taxa de recirculação de lixiviado determinada pela concentração de ácidos voláteis no tratamento da fração orgânica de resíduos sólidos urbanos domésticos / Influence of volatile acids in the variation of leachate recirculation rate in the treatment of the organic fraction of domestical municipal solid waste

Dillenburg, Marcelo Elias 27 October 2006 (has links)
O objetivo deste trabalho foi avaliar a possibilidade de acelerar o processo de digestão anaeróbia da fração orgânica de resíduos sólidos urbanos domésticos em sistemas de duas fases, com taxas crescentes de recirculação de lixiviado, variando a taxa de recirculação de lixiviado em função da concentração de ácidos voláteis. Para tanto, foram operados dois sistemas de reatores, cada um composto por um reator de sólidos, que continha o resíduo sólido a ser tratado e um filtro anaeróbio de fluxo ascendente, que tratava o lixiviado do primeiro, antes que esse lixiviado fosse recirculado ao reator de sólidos. Um dos sistemas teve sua taxa de recirculação aumentada a intervalos constantes, enquanto que no outro o momento do aumento da taxa foi função da concentração de ácido propiônico no sistema. O trabalho teve ainda dois objetivos secundários: avaliar a validade de comparar os resultados dos dois sistemas, operados em paralelo, em função das características dos resíduos sólidos e dos procedimentos adotados para coleta e preparação do substrato e para o carregamento dos reatores; e avaliou-se a possibilidade de utilizar filtros anaeróbios para recuperar reatores acidificados. Durante o desenvolvimento do experimento, foram monitorados os seguintes parâmetros: DQO (não filtrada e filtrada), pH, alcalinidade, série de sólidos, nitrogênio total Kjeldahl, nitrogênio amoniacal, ácidos voláteis e composição do biogás. Foram realizados ainda exames qualitativos da microbiota que se desenvolveu nos reatores, através de microscopia óptica de fluorescência e contraste de fase. Os resultados obtidos permitiram concluir que: a) os procedimentos testados para o carregamento dos reatores de sólidos permitiram a comparação de resultados entre os sistemas; b) os filtros foram capazes de recuperar reatores acidificados; e c) a utilização da concentração de ácido propiônico para determinar o momento da variação da taxa de recirculação permitiu acelerar o processo, embora de forma restrita, para a escala de reatores utilizada. / The purpose of this dissertation was to evaluate the possibility of accelerating the process of anaerobic digestion of the organic fraction of domestic municipal solid waste, in two-stage systems, with increasing leachate recirculation rate, through the use of volatile acids as determining parameter of the moment in which the rate must be varied. To do so, two systems of reactors were operated, each being composed by a solids reactor, which contained the solid waste intended to be treated, and an upflow anaerobic filter, which treated the leachate of the first reactor, before recirculation. One of the systems had its recirculation rate increased at constant spells of time, while, in the other system, the moment of the increase in the recirculation rate was a function of the concentration of propionic acid in the system. This study had yet two secondary purposes: evaluating the validity of comparing the results from the two systems of reactors, operated in parallel, in view of the characteristics of solid waste and the adopted procedures for collecting and preparing the substrate, as well as for the loading of reactors; and evaluating the possibility of using anaerobic filters to recover acidified reactors. The following parameters were measured during the process: COD (filtered and non-filtered), pH, alkalinity, solids, Kjeldahl nitrogen, ammonium nitrogen, volatile acids and biogas composition. The development of microorganisms in the reactors was observed qualitatively, using optical microscopy. It was possible to reach the following conclusions: a) the tested procedures allow the comparison of results between the systems; b) the filters are capable of recovering acidified reactors; and c) the employment of the concentration of propionic acid to determine the moment of increase of leachate recirculation rate is capable of accelerating the process, though in a restricted way, for the scale of reactors used.
328

Batch flow behandling och kontinuerligt flöde av lakvatten i en rotzonsanläggning : En jämförande studie i pilotskala / Landfill leachate treatment in batch-fed and continuous flow constructed subsurface flow wetlands : A pilot-scale comparison

Nilsson, Dan January 2010 (has links)
<p>This report deals with the performance of a batch flow treatment of landfillleachate compared with a continuous flow system. The parameters in focus were total Kjeldahl nitrogen (TKN), BOD5 and COD. The pilot-scale experiment used eight barrels with a volume of 150 liters. Each barrel was constructed differently concerning its flow, its bed material grain size and its presence of plants or not. Four of the barrels worked in batch mode, thus four in continuous flow mode. The continuous flow systems were provided with water trough small tubes with regulators. Samples were collected once a week and analysis was carried out yielding results of BOD5, COD, TKN, pH and conductivity of the effluents. The same parameters were analyzed for the influent every week. The result shows that a wetland is a good way of treating the landfill leachate as the BOD5, COD and TKN decreases. Moreover the color, which contravenes with legislative demands in the region, was distinctly decreased. Yet the report failed to show a significant difference between batch loaded and continuous flow wetlands. More studies have to be carried out in order to determine or contradict whether batch mode in fact provides a better treatment.</p>
329

Batch flow behandling och kontinuerligt flöde av lakvatten i en rotzonsanläggning : En jämförande studie i pilotskala / Landfill leachate treatment in batch-fed and continuous flow constructed subsurface flow wetlands : A pilot-scale comparison

Nilsson, Dan January 2010 (has links)
This report deals with the performance of a batch flow treatment of landfillleachate compared with a continuous flow system. The parameters in focus were total Kjeldahl nitrogen (TKN), BOD5 and COD. The pilot-scale experiment used eight barrels with a volume of 150 liters. Each barrel was constructed differently concerning its flow, its bed material grain size and its presence of plants or not. Four of the barrels worked in batch mode, thus four in continuous flow mode. The continuous flow systems were provided with water trough small tubes with regulators. Samples were collected once a week and analysis was carried out yielding results of BOD5, COD, TKN, pH and conductivity of the effluents. The same parameters were analyzed for the influent every week. The result shows that a wetland is a good way of treating the landfill leachate as the BOD5, COD and TKN decreases. Moreover the color, which contravenes with legislative demands in the region, was distinctly decreased. Yet the report failed to show a significant difference between batch loaded and continuous flow wetlands. More studies have to be carried out in order to determine or contradict whether batch mode in fact provides a better treatment.
330

Optimering av den kemiska reningen vid Fläskebo deponi / Optimization of the Chemical Treatment at Fläskebo Landfill

Nilsson, Anna January 2006 (has links)
Landfill leachate contains a variety of contaminants and is created when rainwater percolates the landfill. For landfill management the leachate is the main issue that can cause problems to the environment. At the landfill of Fläskebo, Renova AB treats the leachate in a local treatment plant. The treatment consists of a chemical treatment step with chemical precipitation, flocculation, sedimentation and filtration, and a final step with a carbon and peat filter. Renova has to ensure that the condition of the leachate reaches the regulation set for the landfill before it is released to the recipient. This regulation has not yet been established and a final suggestion will be given to the county administrative board in spring 2006. In this master thesis the chemical treatment of Fläskebo is optimized. A comparison between the control program and the regulation was made to estimate the contamination of the leachate. Also the effectiveness of the two steps is evaluated. For optimization, the leachate was first tested in a laboratory with different coagulants and flocculants. The purpose was to increase the precipitation of particles and metals; arsenic, cadmium, chromium, mercury, lead, copper, nickel and zinc through sweep floc coagulation and hydroxide precipitation. After the laboratory tests the precipitation was tested in the treatment plant with higher pH and coagulant. Also the process control for sodium hydroxide was examined. The leachate had a small content of organic matter and nutrients, but had a large content of halogenated substances (AOX) and the heavy metals nickel and copper. High concentrations of contaminants were reduced better than low concentrations in the two treatment steps. The carbon and peat filter material also caused an increase of the arsenic content in the leachate after filtration. From the laboratory work the results showed a better reduction of metals with iron-chloride, PlusJÄRN and the anjonic polyacrylamid, Fennopol A. Because of the high content of chloride the iron- sulphate, PurFect was chosen for further tests. The optimal pH for the heavy metals arsenic, zinc, copper and nickel was between pH 9 and 9, 5. The precipitation in the treatment plant showed better results with sodium hydroxide and a higher pH, pH 9 in the flocculation basin. An increase of the coagulant PurFect from 202 mg/l to 225 mg/l meant only a higher chemical cost. The process control of sodium hydroxide showed an oscillating and unstable control performance, which may lead to a higher consumption of chemicals. / Lakvatten har varierande föroreningsgrad och karaktär och bildas då regnvatten perkolerar igenom en deponi. För en deponiverksamhet är lakvattnet den huvudsakliga påverkan på den omgivande miljön. Vid en av Renova ABs deponier, Fläskebo, utanför Göteborg sker reningen av vattnet i den lokala reningsanläggningen. Reningen består av kemisk fällning, flockning, sedimentering och filtrering samt ett kol- och torvfilter. För att få släppa ut lakvattnet har Renova just nu ett prövotidsvillkor på lakvattnets kvalité och till våren 2006 skall förslag på slutgiltiga utsläppsvillkor lämnas till Länsstyrelsen. I detta examensarbete har den kemiska reningen av lakvattnet från Fläskebo optimerats utifrån lakvattnets karaktär. Lakvattnets föroreningsgrad bedömdes efter en jämförelse av analysresultatet inom kontrollprogrammet och riktvärdena i prövotidsvillkoret. Dessutom utvärderades effektiviteten i varje enskilt reningssteg, den kemiska reningen och kol- och torvfiltret. För optimering av den kemiska reningen testades lakvattnet först på lab med olika fällnings- och flockningsmedel. Uppgiften var att öka partikelfällningen och reducera metallerna arsenik, kadmium, krom, kvicksilver, bly, koppar, nickel och zink i lakvattnet genom svepkoagulering och hydroxidfällning. Utifrån resultaten på lab testades sedan fällningen i full skala, pH höjdes i flockningsbassängen och så även dosen fällningsmedel till vattnet. En inledande undersökning av regleringen av lutdosering gjordes med några stegsvarsexperiment. Lakvatten innehöll låga halter av organiskt material och närsalterna kväve och fosfor, medan de halogena ämnena (AOX) och tungmetallerna nickel och koppar var höga. De båda reningsstegen, kemisk rening och kol- och torvfiltret var generellt bra på att rena föroreningar i höga koncentrationer men var sämre vid låga. Kol- och torvfiltret ökade koncentrationen i vattnet av arsenik genom materialets interna läckage. I fällningsförsöken gav järnkloriden, PlusJÄRN och den anjoniska polyakrylamiden, Fennopol A bäst resultat i att avskilja metaller. Järnsulfaten PurFect gav näst bäst resultat och valdes istället för järnkloriden för vidare försök då kloridhalten i lakvattnet redan var högt. Optimalt pH för arsenik, zink, koppar och nickel var inom pHintervallet 9 och 9,5. Fällningen i full skala ute i verket visade ett bättre resultat vid tillsatt lut och ett högre pH (pH 9) i flockningsbassängen. Däremot betydde en höjning av fällningskemikalien från 202 mg/l PurFect till 225 mg/l enbart en ökad kemikaliekostnad och en överdosering. Det visade sig dessutom att lutregleringen var svängig och på gränsen till instabil. Regulatorn bör därför ses över så att risken för ökad kemikaliekonsumption och kostnader minskar.

Page generated in 0.0225 seconds