• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resistência de união de um sistema adesivo irradiado com laser Nd:YAG em dentina tratada com laser de Er:YAG /

Malta, Daniel Alexandre Menezes Pedrosa. January 2007 (has links)
Resumo: A proposta deste estudo foi avaliar por meio do teste de microtração a resistência de união de um sistema adesivo irradiado com laser de Nd:YAG em dentina preparada com laser de Er:YAG. Estudos prévios têm demonstrado que a irradiação com laser após a aplicação do sistema adesivo é eficiente em alcançar alta força de união à tensão e ao cisalhamento. O laser de Er:YAG (Twinlight, Fotona, Eslovênia) com fluência de 60 J/cm2 foi usado para o tratamento da dentina. A irradiação do adesivo foi realizada usando o laser de Nd:YAG (Twinlight, Fotona, Eslovênia) com fluência de 100 J/cm2. As restaurações foram executadas com Adper Single Bond 2/Z250 (3M/ESPE, EUA). Vinte terceiros molares recentemente extraídos e livres de cárie foram empregados. Os dentes foram divididos em quatro grupos experimentais (n = 5): (G1) grupo controle onde não houve irradiação; (G2) irradiação do sistema adesivo com laser de Nd:YAG; (G3) tratamento da dentina com laser de Er:YAG; (G4) tratamento da dentina com laser de Er:YAG mais irradiação do sistema adesivo com laser de Nd:YAG. Um dente de cada grupo foi preparado para avaliação da interface adesiva sob microscopia eletrônica de varredura (MEV). Adicionalmente foi realizada a análise do padrão de fraturas, resultante dos ensaios mecânicos, sob microscopia óptica digital. Os testes de microtração foram realizados em uma máquina de ensaios mecânicos com célula de carga de 1 kN a uma velocidade de 0,5 mm/min. A análise estatística (ANOVA e teste de Tukey), dos dados referentes aos ensaios mecânicos, evidenciaram diferença estatística significante entre os grupos G1 e G3, G1 e G4, G2 e G3, e G2 e G4 e semelhança entre os grupos G1 e G2, e G3 e G4. As fraturas adesivas foram predominantes em todos os grupos experimentais. / Abstract: The purpose of this study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine treated with Er:YAG laser. Previous studies had shown that laser irradiation after the application of an adhesive system is efficient in achieving higher shear bond and tensile bond strength. Er:YAG laser (Twinlight, Fotona, Slovenia) with fluency of the 60 J/cm2 was used for the treatment of the dentine. The irradiation of the adhesive was performed using the Nd:YAG laser (Twinlight, Fotona, Slovenia) with the fluency of the 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250 (3m/ESPE, USA). Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group where there was no irradiation; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) treatment of the dentin with Er:YAG laser; (G4) treatment of the dentin with Er:YAG laser plus irradiation of the adhesive system with Nd:YAG laser. One tooth of each group was prepared for evaluation of adhesive interface under scanning electron microscopy (SEM). In addition was performed an evaluation of the bond failures under digital optic microscopy. The micro tensile bond tests were performed in a MTS universal testing machine with 1 kN load cell at cross-head speed 0,5 mm/min. The statistical analysis (ANOVA and Tukey test) showed difference significant statistics between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all experimental groups. / Orientador: Rosane de Fátima Zanirato Lizarelli / Coorientador: Marcelo Ferrarezi de Andrade / Banca: José Eduardo Pelizon Pelino / Banca: Sizenando de Toledo Porto Neto / Mestre
2

Investigação da quebra de pigmentos por luz /

Esteban Florez, Fernando Luis. January 2009 (has links)
Orientador: Osmir Batista de Oliveira Júnior / Banca: Vanderlei Salvador Bagnato / Banca: Carlos EduardoFrancci / Resumo: O clareamento dental é uma técnica que surgiu no inicio do século XIX. Desde então, e em função dos resultados obtidos ao longo do tempo, esta foi sendo alterada de maneira a reduzir os riscos do procedimento e ao mesmo tempo melhorar o resultado estético obtido. Com o aparecimento das fontes de luz para uso odontológico, novas e interessantes possibilidades surgiram e permitiram a utilização de métodos de aceleração que respeitem a fisiologia pulpar, que diminuam o tempo de exposição do paciente aos agentes peróxidos e promovam ainda a obtenção de bons resultados estéticos. Nos dias de hoje, pode-se observar na literatura importantes questionamentos acerca da contribuição efetiva da luz visível no processo e, os efeitos dos agentes peróxidos nas estruturas cristalinas dos dentes, materiais restauradores em geral e tecidos moles. Estas preocupações foram o cerne da motivação para a realização desta pesquisa, sendo assim, este trabalho vem propor uma série de metodologias inovadoras que avaliem através de tecnologias modernas os mecanismos básicos de interação da luz visível com o peróxido de hidrogênio e com os pigmentos orgânicos. Os experimentos aqui demonstrados abordam os fatores críticos relacionados com a eficiência do processo em diferentes substratos por meio de análise de transmitância, de fluorescência e imagens digitais. Com estes estudos pretendemos responder de maneira objetiva algumas das questões que foram observadas serem de fundamental importância no esclarecimento da real eficiência e eficácia da luz no clareamento dental. / Abstract: The dental bleaching is a technique that appeared in the beginning of the XIX century. Since then, and in function of the obtained results a long the time, this has been altered in way to reduce the procedure risks and at the same time improve the aesthetic results. With the rise of light sources to be used in dentistry, new and exciting possibilities appeared and allowed the use of catalytic methods that respect the pulpal physiology, which diminishes the exposure time of the patients to the bleaching agents and provides good aesthetic results. In nowadays, it is possible to observe in the literature important questionings over the real contribution of light in the process and, the effects of the peroxide over the crystalline structure of the teeth, restorative materials and soft tissues. These concerning were the major motivation to the realization of this research, in this way, this work proposes a new series of methods that asses by the use of new technologies the basic mechanisms of visible light interaction with the hydrogen peroxide and with the organic pigments. The experiments here demonstrated study the critical factors related with the process efficiency in different substrates by digital images, transmittance and fluorescence. With these studies we pretend to respond in objective way some questions that were observed to be of fundamental importance in the understanding of the light efficiency and efficacy to the dental bleaching. / Mestre
3

Efetividade da fluorescência a laser no diagnóstico de lesões de cárie. Estudos in vitro e in vivo /

Diniz, Michele Baffi. January 2006 (has links)
Orientador: Rita de Cássia Loiola Cordeiro / Banca: Fausto Medeires Mendes / Banca: Lourdes Aparecida Martins dos Santos Pinto / Resumo: O objetivo do presente estudo foi avaliar a efetividade da fluorescência a laser (KaVo DIAGNOdent) para a determinação da severidade de lesões de cárie oclusal em dentes permanentes in vivo e para determinação da remineralização in vitro de lesões de cárie induzidas artificialmente em esmalte de dentes bovinos. No estudo in vitro, 78 blocos de esmalte com lesões de cárie artificial (mancha branca) com valores de dureza Vickers de 38,48 l 0,85 foram submetidos ao tratamento com dentifrício fluoretado durante a ciclagem de pH, para promover a remineralização. Antes do início do experimento, após a desmineralização e após a remineralização foram realizadas análises com a fluorescência a laser e análises de microdureza superficial do esmalte. Foram encontradas diferenças significantes nas medidas de microdureza superficial (p < 0,0001) nas 3 etapas. Os valores encontrados nas leituras com a fluorescência a laser foram extremamente baixos (entre 0-5), apresentando diferença estaticamente significante somente após a remineralização. No estudo in vivo, foram selecionados 130 sítios de primeiros molares permanentes hígidos ou com presença de lesões de cárie incipientes na superfície oclusal, em crianças com idade entre 7 a 12 anos. Após profilaxia, foi realizada a inspeção visual pelo Examinador A e 23 o exame com o DIAGNOdent pelo Examinador B. Apenas os sítios com sinais sugerindo lesão de cárie foram abertos com equipamentos que permitiram preparos conservadores e a extensão da lesão (padrão-ouro) foi determinada pelo Examinador C. De acordo com os pontos de corte propostos pela KaVo (1999) e com os novos pontos de corte estabelecidos pela curva ROC, observamos uma diferença na especificidade, 0,31 e 0,85 respectivamente, considerando todas as lesões como cariadas, e um equilíbrio entre sensibilidade ...(Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to evaluate the effectiveness of laser fluorescence device (DIAGNOdent) in detecting in vivo depth of occlusal caries lesions in permanent teeth and detecting in vitro remineralization of artificial caries lesions in enamel bovine teeth. On in vitro study, 78 enamel blocks with artificial caries lesions (white spot lesions) with Vickers microhardness number of 38.48 l 0.85 were submitted to dentifrice treatment during the pH-cycling, to promote remineralization. At baseline, after demineralization and after remineralization analyses were carried through with laser fluorescence device and enamel superficial microhardness analyses. Significant differences in superficial microhardness measures were found in the 3 stages (p < 0.0001). Values found in laser fluorescence readings were extremely low (between 0-5), presenting difference statistically significant only after remineralization. On in vivo study, one hundred and third sites from occlusal surfaces of sound or carious first permanent molars were selected in children, aged between 7 and 12 years. After professional cleaning, visual inspection was performed by Examiner A and laser fluorescence (DIAGNOdent) assessment by Examiner B. Only the sites presenting signals suggesting caries lesions were opened that resulted from minimal intervention and the 26 lesion extension (gold-standard) was determined by Examiner C. In accordance with cut-off points proposed by KaVo (1999) and with the new cut-off points established by ROC curves, we observe a difference in specificity, 0.31 and 0.85 respectively, considering all lesions as caries, and a balance between sensitivity (0.70) and specificity (0.87) for the new cut-off points considering dentine lesions only. Accuracy for visual inspection was ...(Complete abstract, click electronic address below). / Mestre

Page generated in 0.0667 seconds