Spelling suggestions: "subject:"basers dde diode"" "subject:"basers dee diode""
1 |
Influência dos tratamentos dessensibilizantes associados ao laser de diodo na permeabilidade dentinária / Influence of desensitizing treatments associated with diode laser on dentin permeability.Sanches, Júlia Olien 10 January 2013 (has links)
Objetivo: Este estudo avaliou o efeito dos agentes dessensibilizantes associados ou não ao laser de diodo na permeabilidade dentinária e na morfologia da superfície. Materiais e Métodos: Para este estudo, 104 espécimes de dentina radicular bovina foram divididos aleatoriamente em 4 grupos e 2 subgrupos (n=13): G1A= nenhum tratamento (controle), G1B= laser de diodo, G2A= Oxagel, G2B= laser de diodo + Oxagel, G3A= Mi Paste, G3B= laser de diodo + Mi Paste, G4A= Sensitive Pró-Alívio dessensibilizante, G4B= laser de diodo + Sensitive Pró-Alívio dessensibilizante. Para análise da permeabilidade, 10 espécimes de cada grupo foram imersos em ácido clorídrico a 1% durante 20 segundos, 3 vezes, com intervalo de 2 horas entre as imersões, para exposição dos túbulos dentinários. A aplicação dos agentes dessensibilizantes foi feita de acordo com as instruções do fabricante e a irradiação com o laser de diodo foi feita no modo contato, comprimento de onda de 970 nm +/- 10 nm, potência máxima de 7 W CW, frequência de 10 Hz, durante 25 segundos. Em seguida, os espécimes foram submetidos à coloração histoquímica e seccionados para serem analisados quanto à permeabilidade por meio de microscopia óptica (MO). A permeabilidade dentinária foi dada pela porcentagem de penetração do corante em relação à área total do espécime seccionado. Os espécimes remanescentes (n = 3) foram utilizados para análise microscópica da superfície que foi dividida em duas áreas (controle e tratada). A exposição dos túbulos dentinários e a aplicação dos tratamentos foram realizadas da forma já descrita e, na sequência, os espécimes foram avaliados em microscopia eletrônica de varredura (MEV). Os valores obtidos de permeabilidade foram analisados através da ANOVA. Resultados: Nenhuma diferença estatística significante foi observada entre os tratamentos. Na microscopia eletrônica de varredura, foi observada uma ligeira diferença entre a área tratada e a área controle, exceto no grupo 4B. Comparando os grupos A e B (sem e associado ao laser, respectivamente), nenhuma mudança significativa foi notada na superfície dentinária. Conclusão: A aplicação dos agentes dessensibilizantes associados ou não ao laser diodo não influenciou na permeabilidade dentinária radicular e na morfologia da superfície dentinária. / Objective: This study evaluated the effect of desensitizing agents associated or not with laser diode on dentin permeability and surface morphology. Materials and Methods: For this study, 104 bovine root dentin specimens were randomly divided into 4 groups and 2 subgroups (n = 13): G1A = no treatment (control), G1B= diode laser, G2A= Oxagel, G2B= diode laser + Oxagel, G3A= Mi Paste, G3B= diode laser + Mi Paste, G4A= Sensitive Pro-Relief desensitizing, G4B= diode laser + Sensitive Pro-Relief desensitizing. For permeability analysis , 10 specimens were immersed in 1% hydrochloric acid for 20 seconds, three times, with an interval of 2 hours between them, to expose the dentinal tubules. The application of desensitizing agents was performed according to the manufacturers instructions and the irradiation with the laser diode was made on contact mode, wavelength of 970 nm +/- 10 nm, maximum output 7 W CW, 10 Hz, for 25 seconds. After that, the specimens were imaged in an optical microscope (OM) and permeability was measured in the digitized images as the percentage of cooper ions penetration over the total area. The remaining specimens (n = 3) were used for surface microscopic analysis and they were divided in two areas (control and treated). The dentinal tubules exposure and the treatments application were performed as previously described and then analysed in scanning electron microscopy (SEM). The permeability values were analyzed using ANOVA. Results: No statistical significant difference among the treatments was observed. For scanning electron microscopy, there was a slight difference between the treated and control area, except for group 4B. Comparing groups A and B (without and associated with laser, respectively), no significant change was verified on the dentin surface. Conclusion: The application of desensitizing agents associated or not with diode laser did not affect the root dentin permeability and the dentin surface morphology.
|
2 |
Influência dos tratamentos dessensibilizantes associados ao laser de diodo na permeabilidade dentinária / Influence of desensitizing treatments associated with diode laser on dentin permeability.Júlia Olien Sanches 10 January 2013 (has links)
Objetivo: Este estudo avaliou o efeito dos agentes dessensibilizantes associados ou não ao laser de diodo na permeabilidade dentinária e na morfologia da superfície. Materiais e Métodos: Para este estudo, 104 espécimes de dentina radicular bovina foram divididos aleatoriamente em 4 grupos e 2 subgrupos (n=13): G1A= nenhum tratamento (controle), G1B= laser de diodo, G2A= Oxagel, G2B= laser de diodo + Oxagel, G3A= Mi Paste, G3B= laser de diodo + Mi Paste, G4A= Sensitive Pró-Alívio dessensibilizante, G4B= laser de diodo + Sensitive Pró-Alívio dessensibilizante. Para análise da permeabilidade, 10 espécimes de cada grupo foram imersos em ácido clorídrico a 1% durante 20 segundos, 3 vezes, com intervalo de 2 horas entre as imersões, para exposição dos túbulos dentinários. A aplicação dos agentes dessensibilizantes foi feita de acordo com as instruções do fabricante e a irradiação com o laser de diodo foi feita no modo contato, comprimento de onda de 970 nm +/- 10 nm, potência máxima de 7 W CW, frequência de 10 Hz, durante 25 segundos. Em seguida, os espécimes foram submetidos à coloração histoquímica e seccionados para serem analisados quanto à permeabilidade por meio de microscopia óptica (MO). A permeabilidade dentinária foi dada pela porcentagem de penetração do corante em relação à área total do espécime seccionado. Os espécimes remanescentes (n = 3) foram utilizados para análise microscópica da superfície que foi dividida em duas áreas (controle e tratada). A exposição dos túbulos dentinários e a aplicação dos tratamentos foram realizadas da forma já descrita e, na sequência, os espécimes foram avaliados em microscopia eletrônica de varredura (MEV). Os valores obtidos de permeabilidade foram analisados através da ANOVA. Resultados: Nenhuma diferença estatística significante foi observada entre os tratamentos. Na microscopia eletrônica de varredura, foi observada uma ligeira diferença entre a área tratada e a área controle, exceto no grupo 4B. Comparando os grupos A e B (sem e associado ao laser, respectivamente), nenhuma mudança significativa foi notada na superfície dentinária. Conclusão: A aplicação dos agentes dessensibilizantes associados ou não ao laser diodo não influenciou na permeabilidade dentinária radicular e na morfologia da superfície dentinária. / Objective: This study evaluated the effect of desensitizing agents associated or not with laser diode on dentin permeability and surface morphology. Materials and Methods: For this study, 104 bovine root dentin specimens were randomly divided into 4 groups and 2 subgroups (n = 13): G1A = no treatment (control), G1B= diode laser, G2A= Oxagel, G2B= diode laser + Oxagel, G3A= Mi Paste, G3B= diode laser + Mi Paste, G4A= Sensitive Pro-Relief desensitizing, G4B= diode laser + Sensitive Pro-Relief desensitizing. For permeability analysis , 10 specimens were immersed in 1% hydrochloric acid for 20 seconds, three times, with an interval of 2 hours between them, to expose the dentinal tubules. The application of desensitizing agents was performed according to the manufacturers instructions and the irradiation with the laser diode was made on contact mode, wavelength of 970 nm +/- 10 nm, maximum output 7 W CW, 10 Hz, for 25 seconds. After that, the specimens were imaged in an optical microscope (OM) and permeability was measured in the digitized images as the percentage of cooper ions penetration over the total area. The remaining specimens (n = 3) were used for surface microscopic analysis and they were divided in two areas (control and treated). The dentinal tubules exposure and the treatments application were performed as previously described and then analysed in scanning electron microscopy (SEM). The permeability values were analyzed using ANOVA. Results: No statistical significant difference among the treatments was observed. For scanning electron microscopy, there was a slight difference between the treated and control area, except for group 4B. Comparing groups A and B (without and associated with laser, respectively), no significant change was verified on the dentin surface. Conclusion: The application of desensitizing agents associated or not with diode laser did not affect the root dentin permeability and the dentin surface morphology.
|
3 |
AVALIAÇÃO IN VIVO E IN VITRO DE TERAPIAS DE USO EM CONSULTÓRIO PARA O TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA / IN VIVO AND IN VITRO ASSESSMENT OF IN-OFFICE THERAPIES USED FOR TREATING DENTINAL HYPERSENSITIVITYOsmari, Deise 06 December 2011 (has links)
Dentinal hypersensitivity (DH) is a frequent clinical situation that is characterized by discomfort with pain ranging from slight to unbearable and it requires the professional to choose the appropriate therapy. Therefore, the aim of this study was to perform a clinical and morphological assessment of four in office therapies used for treating DH. The desensitizing therapies assessed were as follows: G1: fluoridated varnish (Control Group); G2: potassium oxalate; G3: hybridization with an adhesive system; G4: high-power diode laser. Twenty patients participated in the randomized, double-blind, controlled and split-mouth clinical study, each patient with 1 eligible tooth in each quadrant. Pain was measured using the Visual Analog Scale (VAS) after evaporative stimulus before the beginning of treatment, soon after the procedure and 15, 30 and 60 days after each application. The values of VAS immediately after the therapies, as well as after 15, 30 and 60 days, were compared to baseline values by the Wilcoxon test (non-parametric paired data) (α=0.05). The variation (Δ) in the VAS after each experimental group (VAS x days VAS baseline) was compared among the four experimental groups by ANOVA, following the Tukey s post hoc test (α =0.05). Fifteen dentin blocks (n=3) were obtained from the cervical third of vestibular faces of human pre-molar teeth for morphological analysis. Enamel was removed to expose dentin surface, polished with silicon carbide abrasive papers, and etched with 6% citric acid for 2 minutes. After therapies, the specimens were fractured in the buccolingual direction and prepared for analysis under Scanning Electron Microscope. The specimens were analyzed qualitatively both from the view of the buccal surface view and fractured surface. The variation of VAS immediately after therapies, subtracting the baseline value of VAS, differed among the groups. The highest value was found in G1 (fluoridated varnish) and the lowest value in G3 (adhesive system). With regard to VAS, no statistically significant differences among the therapies were found after the time intervals that corresponded to the assessments after 15, 30 and 60 days. In the group without treatment, etching removed the smear layer and exposed the dentinal tubules. A film on the surface with infiltration of varnish plugs into the tubules was found in the fluoridated varnish group. The oxalate group presented partial occlusion of the tubules with formation of crystals inside them. The tubules in the adhesive system group were obliterated by the formation of hybrid layer and a mechanical barrier on the surface. The high-power diode laser altered dentin superficially during melting and re-solidification, which partially occluded the tubules. All treatments were effective in reducing DH within the 60-day period and all desensitizing agents have shown the ability to modify the dentin surface by partially or completely occluding the dentinal tubules. / Caracterizada pelo desconforto causado por dores leves até insuportáveis, a hipersensibilidade dentinária (HD) é uma situação clínica frequente, exigindo do profissional o desafio da escolha de uma terapia adequada. Assim, este trabalho teve por objetivo realizar uma avaliação clínica e morfológica da ação de quatro terapias de uso em consultório no tratamento da HD. As terapias dessensibilizantes avaliadas foram: G1: verniz fluoretado (grupo controle); G2: oxalato de potássio; G3: hibridização com sistema adesivo; G4: laser de diodo em alta potência. O estudo clínico, randomizado, controlado, duplo cego, com desenho de boca-dividida contou com a participação de 20 pacientes, com um dente elegível em cada quadrante, sendo a dor quantificada através da Escala Visual Analógica (EVA) após estímulo evaporativo, antes do início do tratamento, logo em seguida à aplicação e após 15, 30 e 60 dias. Os valores da EVA após a aplicação das terapias, bem como após 15, 30 e 60 dias, foram comparados aos valores do baseline por meio de teste de Wilcoxon (dados pareados não paramétricos) (α=0,05). A variação (Δ) na EVA após cada período experimental (EVA xdias - EVA baseline) foi comparada entre os quatro grupos experimentais por meio de ANOVA, seguido de teste post hoc de Tukey (α =0,05). Para a análise morfológica foram obtidos 15 blocos de dentina (n=3) do terço cervical da face vestibular de pré-molares humanos extraídos. O esmalte foi removido para expor a superfície dentinária, sendo realizado o polimento com lixas de carbeto de silício e o condicionamento com ácido cítrico 6% por 2 min. Após a aplicação das terapias, os espécimes foram fraturados no sentido linguo-vestibular, e preparados para análise no microscópio eletrônico de varredura, sendo analisados tanto na vista da superfície vestibular quanto da superfície clivada, de forma qualitativa. Quando verificada as médias da EVA, encontrou-se efetiva ação dessensibilizante imediata no grupo do verniz fluoretado e do oxalato de potássio, sendo que aos 60 dias, todos os grupos estudados apresentaram efeito dessensibilizante significativo. A variação da EVA (EVA xdias - EVA baseline) após a aplicação imediata das terapias, subtraída do valor da EVA no baseline, diferiu entre os grupos, sendo maior no G1 (verniz fluoretado) e menor no G3 (Sistema adesivo). Nos períodos que corresponderam às avaliações de 15, 30 e 60 dias, não houve diferença estatística entre as quatro terapias quanto à variação na EVA. Na análise morfológica do grupo sem tratamento, o condicionamento promoveu remoção de smear layer e exposição de túbulos dentinários. No grupo do verniz fluoretado observou-se uma película sobre a superfície, com plugs de verniz infiltrados nos túbulos. No grupo do oxalato ocorreu oclusão parcial da embocadura do túbulo, com formação de cristais em seu interior. O grupo do sistema adesivo obliterou os túbulos pela formação da camada híbrida e de uma cobertura superficial. O laser de diodo em alta potência causou leve derretimento e ressolidificação, ocluindo parcialmente os túbulos. Todos os tratamentos foram efetivos na redução da HD no período de 60 dias, sendo que todos os agentes dessensibilizantes mostraram capacidade de modificar a superfície da dentina, ocluindo de forma parcial ou total os túbulos dentinários.
|
4 |
Preparação de laser de diodo e sua utilização em aprisionamento e estudo de átomos frios / Preparation of diode laser and its use in trapping and study of cold atoms.Tuboy, Aparecida Marika 05 July 1996 (has links)
Este trabalho relata o desenvolvimento de todo o aparato experimental para a realização de aprisionamento de césio através de uma armadilha magneto-óptica. As fontes de luz neste processo foram os lasers de diodo e todo seu sistema para operação, estabilização e redução da largura de linha foi construído. As medidas das constantes de mola e amortecimento foram realizadas como função dos parâmetros característicos das armadilhas de césio e de sódio. Também realizamos outros experimentos com átomos aprisionados de sódio na presença de duas freqüências, linha D1 e D2. A primeira medida constitui na obtenção da taxa de colisões entre átomos aprisionados na linha D1 e depois foi realizado observações de uma nova estrutura operando neste regime. / This thesis describes the development of a complete experimental setup for trapping cesium by a magneto-optical trap (MOT). In this work we have employed diode lasers as light sources and built the entire system for their operation, stabilization and linewidth reduction. We have measured the MOT spring and damping constants as functions of the characteristic parameters of the cesium and sodium traps. We have also carried out two other experiments on trapped sodium atoms operating in the simultaneous presence of the D1 and D2 line frequencies. The first experiment has established the collision rate of trapped atoms in the D1 line MOT and the second has allowed us to observe a new structure operating in this two-frequency regime.
|
5 |
Preparação de laser de diodo e sua utilização em aprisionamento e estudo de átomos frios / Preparation of diode laser and its use in trapping and study of cold atoms.Aparecida Marika Tuboy 05 July 1996 (has links)
Este trabalho relata o desenvolvimento de todo o aparato experimental para a realização de aprisionamento de césio através de uma armadilha magneto-óptica. As fontes de luz neste processo foram os lasers de diodo e todo seu sistema para operação, estabilização e redução da largura de linha foi construído. As medidas das constantes de mola e amortecimento foram realizadas como função dos parâmetros característicos das armadilhas de césio e de sódio. Também realizamos outros experimentos com átomos aprisionados de sódio na presença de duas freqüências, linha D1 e D2. A primeira medida constitui na obtenção da taxa de colisões entre átomos aprisionados na linha D1 e depois foi realizado observações de uma nova estrutura operando neste regime. / This thesis describes the development of a complete experimental setup for trapping cesium by a magneto-optical trap (MOT). In this work we have employed diode lasers as light sources and built the entire system for their operation, stabilization and linewidth reduction. We have measured the MOT spring and damping constants as functions of the characteristic parameters of the cesium and sodium traps. We have also carried out two other experiments on trapped sodium atoms operating in the simultaneous presence of the D1 and D2 line frequencies. The first experiment has established the collision rate of trapped atoms in the D1 line MOT and the second has allowed us to observe a new structure operating in this two-frequency regime.
|
6 |
Estabilização de lasers de diodo para utilização em espectroscopia atômica. / Stabilization of diode lasers for use in atomic spectroscopy.Tuboy, Aparecida Marika 13 July 1990 (has links)
Um dos primeiros requisitos para utilização de lasers de diodo em espectroscopia é sua estabilização térmica. Neste trabalho desenvolvemos um sistema de controle de temperatura para laser de diodo que permite estabilização melhor que 0.01°C. O controle é feito através de um sistema sensor e um elemento Peltier como atuador. Lasers somente estabilizados em temperatura (estabilização primária) foram utilizados para realização de espectroscopia de vapores atômicos de Rb e Cs. / One of the first requisites for utilization of diode lasers in spectroscopy is its thermal stabilization. In this work, we develop a diode laser temperature controlling system, which yields stabilization better than 0.01°C. The controlling is obtained by means of a sensor system and a Peltier element as actuator. Lasers stabilized in temperature only (primary stabilizations) were utilized in the spectroscopy of atomic vapors of Rb and Cs.
|
7 |
Estabilização de lasers de diodo para utilização em espectroscopia atômica. / Stabilization of diode lasers for use in atomic spectroscopy.Aparecida Marika Tuboy 13 July 1990 (has links)
Um dos primeiros requisitos para utilização de lasers de diodo em espectroscopia é sua estabilização térmica. Neste trabalho desenvolvemos um sistema de controle de temperatura para laser de diodo que permite estabilização melhor que 0.01°C. O controle é feito através de um sistema sensor e um elemento Peltier como atuador. Lasers somente estabilizados em temperatura (estabilização primária) foram utilizados para realização de espectroscopia de vapores atômicos de Rb e Cs. / One of the first requisites for utilization of diode lasers in spectroscopy is its thermal stabilization. In this work, we develop a diode laser temperature controlling system, which yields stabilization better than 0.01°C. The controlling is obtained by means of a sensor system and a Peltier element as actuator. Lasers stabilized in temperature only (primary stabilizations) were utilized in the spectroscopy of atomic vapors of Rb and Cs.
|
Page generated in 0.0684 seconds