Spelling suggestions: "subject:"basers."" "subject:"fasers.""
571 |
Desenvolvimento de um laser de centros de cor-centros F2 em LiFUDO, PAULO T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:35Z (GMT). No. of bitstreams: 1
02455.pdf: 1496860 bytes, checksum: 707ae6d051d3717f9af83f373858fd65 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
572 |
Laser de Nd:YAG de alta potência, estabilidade e qualidade de feixe / High power Nd:YAG laser with high stability and beam qualityPINTO, REGIANE de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:16:04Z
No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:16:04Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
573 |
Caracterização do LiNbO3:Er+3 como meio ativo para lasers de estado sólido através dos espectros de absorção/emissão polarizada e medida dos tempos de vida de luminescência. / Characterization of LiNbO3:Er+3 as active media for solid-state lasers through polarized absorption/ emission spectra and measurements of luminescence lifetime.Debora Marcondes Bastos Pereira Milori 20 September 1989 (has links)
Este trabalho consiste na caracterização ótica de monocristais de LiNbO3: Er+3, visando a possibilidade deste sistema ser meio ativo para laser. Os resultados obtidos para absorção e emissão foram satisfatórios, sendo bastante compatíveis com os do modelo teórico adotado. O tempo de vida de luminescência das transições 4S3/2 - 4I15/2 e 4F9/2 - 4I15/2 foi medido, à temperatura ambiente e de nitrogênio líquido, mostrando que elas são possíveis candidatas a transições laser. Também foi feito um estudo sobre o comportamento das concentrações das impurezas indesejáveis OH- e Fe2+, através de tratamento térmico. O controle dessas concentrações foi feito através das técnicas de RPE e absorção ótica e os resultados mostraram que é perfeitamente possível eliminar tais impurezas de uma forma totalmente controlada. / This work consists in the optical characterization of LiNbO3:Er3+ single crystals, aiming to verify the possibility of this system being an active media for laser. The absorption and emission results were satisfactory, being compatible enough with the theoretical model adopted. The luminescence lifetime of the 4S3/2 - 4I15/2 e 4F9/2 - 4I15/2 transitions was measured at the ambient and liquid nitrogen temperature, showing that they are possible candidates for laser transitions. The behavior of the undesirable OH- and Fe2+ impurities was also studied through thermal treatment. The control of these concentrations was done using the EPR and optical absorption techniques and the results showed it is possible to eliminate such impurities in a totally controlled way.
|
574 |
Influência da irradiação com lasers de alta potência na microinfiltração bacteriana e fúngica em dentes humanos retrobturados com MTA / High power lasers Influence in bacterial and fungical microleakage in MTA retrofillsCarmo Antonio Aun 02 April 2008 (has links)
Este estudo experimental avaliou, in vitro, a microinfiltração de E. faecalis e C. albicans em raízes cujas superfícies apicais ressectadas e retropreparadas para obturação retrógrada sofreram irradiação dos lasers Nd:YAG, Diodo 810 nm e Er,Cr:YSGG, e posteriormente retrobturadas com MTA. Setenta raízes foram instrumentadas, obturadas endodonticamente, apicectomizadas e receberam retropreparos com pontas ultra-sônicas diamantadas e lisas na potência média. A divisão dos espécimes se deu de acordo com o laser utilizado e o tipo de microorganismo. Os grupos G1 e G5 não foram irradiados, G2 e G6 irradiados com Nd:YAG, G3 e G7 com Diodo e G4 e G8 com Er,Cr:YSGG (n = 8). Foram utilizados controles positivo (n = 3) e negativo (n = 3). Todos os procedimentos operatórios foram realizados com um dispositivo de simulação de dificuldades operatórias. Após a impermeabilização, colagem das raízes em tubos preparados, esterilização e retrobturação com MTA branco, o sistema de câmaras superior, contendo o inóculo de microorganismos, e inferior, contendo meio esterilizado foi montado em contato com o ápice. Os grupos G1 a G4 foram inoculados com E. faecalis, e os grupos G5 a G8 com C. albicans. A troca de meio na câmara superior se deu a cada 3 dias e a verificação da turvação do meio inferior era diária, por um período de 60 dias. Ao final, os resultados indicaram que: o controle positivo apresentou 100% de microinfiltração, o controle negativo não microinfiltrou e os grupos experimentais apresentaram padrões de microinfiltração que variaram entre 50% (G1) e 100% (G2) de microinfiltração, onde 68,75% do total de espécimes microinfiltraram. Não houve diferença estatística significativa entre os grupos aplicando-se os testes Exato de Fischer e Kruskal-Wallis (p > 0,05) em nenhuma interação. Pode-se concluir que o tratamento das retrocavidades e superfície apical ressectada, com os lasers utilizados neste estudo, não alterou o padrão de microinfiltração das retrobturações com MTA frente a E. faecalis e C. albicans. O tipo de microorganismo utilizado também não alterou a quantidade de espécimes microinfiltrados. / This in vitro experimental study evaluated the microleakage of E. faecalis and C. albicans in roots whose ressected apical surfaces and retrocavities had suffered irradiation from Nd:YAG, Diode 810 nm and Er,Cr:YSGG lasers, and later retrofiled with MTA. Seventy roots had been prepared, obturated, had suffered apicoectomy and were retroprepared with diamond and conventional ultra-sonic tips in the average power. The division of specimens was in accordance with the used laser and the type of microorganism. The groups G1 and G5 had not been irradiated, G2 and G6 irradiated with Nd:YAG, G3 and G7 with Diode and G4 and G8 with Er, Cr:YSGG (n = 8). Positive (n = 3) and negative (n = 3) controls had been used. All procedures executed until this point had been carried inside an access difficulties simulation device. After the waterproofing, attachment of the roots in prepared tubes and sterilization, the retrofillings were made using white MTA. The superior chambers were inoculated with the microorganisms and inferior chambers were completed with sterile culture broth in contact with the root tip. The G1, G2, G3 and G4 groups had been inoculated with E. faecalis and the rest of the groups with C. albicans. The contaminated broths of the upper chambers were exchanged each 3 days and for 60 days the verification of the turbidity in the inferior chambers was evaluated daily. At the end, the results had indicated that: the positive control had 100% microleakage, the negative control none and the experimental groups had presented microleakege patterns that range from 50% (G1) to 100% (G2), with a total of 68.75% of all specimens presenting microleakage. Applying the Exact Fischer test and Kruskal-Wallis test (p > 0,05), no significant statistical difference between the groups were observed in any interaction. It can be concluded that the treatment of the retrocavities and ressected apical surface, with the lasers used in this study, did not modify the rate of E. faecalis and C. albicans microleakage in MTA retrofillings. Also the type of used microorganism did not seem to modify the amount of microleakage in the specimens.
|
575 |
Efeito da irrigação e medicação endodôntica em dentina infectada por biofilmes oraisRonald Ordinola Zapata 07 June 2013 (has links)
O objetivo desse estudo foi avaliar o efeito antimicrobiano da irrigação e da medicação endodôntica em dentina infectada por biofilmes orais. Na primeira parte do estudo, avaliaram-se as seguintes soluções irrigadoras: hipoclorito de sódio a 1%, clorexidina a 2%, ácido cítrico a 10% e EDTA a 17%. Na segunda parte, avaliaram-se soluções irrigadoras contendo associações (MTAD, Smear Clear, Qmix, ácido maleico a 7%, iodo-iodeto de potássio a 2% e ácido peracético a 4%), sendo essas soluções comparadas a 2 concentrações de hipoclorito de sódio. Na terceira parte, avaliou-se o efeito de dispositivos sônicos, ultrassônicos e de laser na capacidade de limpeza do hipoclorito de sódio a 6%, com uso de microscópio eletrônico de varredura. Na quarta parte, avaliaram-se os efeitos antimicrobianos de 3 pastas de hidróxido de cálcio contendo 3 radiopacificadores diferentes (óxido de zinco, sulfato de bário e iodofórmio). No último experimento, foram avaliadas as propriedades antimicrobianas da pasta triantibiótica, da clorexidina em gel e da pasta aquosa de hidróxido de cálcio. Os resultados mostraram que todas as soluções de hipoclorito de sódio testadas e o ácido peracético a 4% foram mais efetivas sobre o biofilme em comparação a todos os irrigantes testados. As soluções de hipoclorito de sódio propiciaram significativamente uma melhor limpeza da dentina. O ácido peracético foi também efetivo para dissolver células do biofilme. A ativação do hipoclorito de sódio com o ultrassom e com laser interferiu favoravelmente na limpeza da dentina infectada. A pasta triantibiótica e o hidróxido de cálcio associado ao iodofórmio foram os medicamentos mais efetivos na descontaminação da dentina infectada. Portanto, o protocolo ideal que deve ser adotado para garantir uma descontaminação efetiva da dentina contaminada por biofilmes orais inclui o uso de hipoclorito de sódio ativado por ultrassom ou laser e medicação intracanal de hidróxido de cálcio com iodofórmio. O ácido peracético e a pasta triantibiótica apresentaram resultados promissores. / The aim of this study was to evaluate the antimicrobial effect of endodontic irrigation and medication on biofilm infected dentin. In the first part, we evaluated the following irrigant solutions: 1% sodium hypochlorite, 2% chlorhexidine, 10% citric acid and 17% EDTA. In the second part, irrigant solutions containing combinations of antimicrobials such as \"MTAD,\" \"Smear Clear\", \"Qmix\", 7% maleic acid and 2% iodine-potassium iodide and 4% peracetic acid were evaluated. These solutions were compared to 2 concentrations of sodium hypochlorite. In the third part, we evaluated the effect of sonic, ultrasonic and laser irrigation on the cleaning ability of biofilm infected dentin using 6% sodium hypochlorite under scanning electron microscope. In the fourth part, we evaluated the antimicrobial effects of 3 calcium hydroxide pastes containing 3 different radiopacifiers (zinc oxide, barium sulfate and iodoform). In the last experiment, we evaluated the antimicrobial properties of the triantibiotic paste, 2% chlorhexidine gel and calcium hydroxide paste. The results showed that the sodium hypochlorite and the peracetic acid solutions were more effective to decontaminate the biofilm infected dentin in comparison to all of the tested irrigants. The sodium hypochlorite solutions allowed significantly better cleaning of the dentine. The peracetic acid was also effective to dissolve the biofilm cells. Activation of 6% sodium hypochlorite with ultrasonic and laser increased the cleaning of biofilm infected dentin. The triantibiotic paste and calcium hydroxide associated to iodoform were the most effective intracanal dressings available for the decontamination of the infected dentin. Therefore, the ideal protocol to be adopted in order to ensure an effective decontamination of biofilm infected dentin includes the use of sodium hypochlorite, specially activated by ultrasound or laser; and the use of calcium hydroxide with iodoform intracanal dressing. The peracetic acid and the triantibiotic paste also showed promising results.
|
576 |
Estudo in vitro da microinfiltração em restaurações de cavidades classe V preparadas com alta rotação e lasers Er:YAG e Er, Cr:YSGG, utilizando-se dois sistemas adesivos / IN VITRO STUDY OF THE MICROLEAKAGE IN CLASS V CAVITIES RESTORATIONS PREPARED WITH AIR TURBINE AND LASERS Er:YAG AND Er,Cr:YSGG, AND BEING USED TWO ADHESIVE SYSTEMSVera Lucia Moldes 19 February 2004 (has links)
RESUMO O objetivo deste estudo foi comparar o grau de microinfiltração nas margens gengival e incisal de restaurações classe V frente aos seguintes métodos de preparo: 1) alta rotação, 2) laser Er:YAG modelo Opus 20 (Opus Dent) e 3) laser Er,Cr:YSGG modelo Waterlase (Millennium, Biolase). Foram avaliados também os sistemas adesivos Single Bond (3M ESPE) e One-Up Bond F (Tokuyama). Sessenta incisivos bovinos hígidos, extraídos foram divididos em 6 grupos de 10 elementos. As cavidades foram preparadas de acordo com o protocolo a seguir: grupo 1 e 2 utilizando alta rotação, grupo 3 e 5 laser de Er:YAG, grupo 4 e 6 laser de Er,Cr:YSGG. Os espécimes foram restaurados com resina composta Z250 (3M ESPE) com a utilização prévia dos adesivos Single Bond (grupos 1, 3 e 4) e One-Up Bond F (grupos 2, 5 e 6). Após armazenagem em água destilada a 37ºC por 24h, os espécimes foram polidos, termociclados e imersos em solução de nitrato de prata a 50% por 8h. Os espécimes foram incluídos, seccionados em duas porções e revelados à 10min de exposição sob lâmpada phothoflood. Os corpos-de-prova infiltrados foram avaliados em lupa estereomicroscópica com 25 vezes de aumento a fim de detectar o grau de microinfiltração de cada uma das margens. A mais infiltrada foi escolhida para representar o resultado individual de cada corpo-de-prova. Foram realizadas fotos, e encaminhadas a três examinadores utilizando o método de escores 0, 1, 2 e 3. Os dados obtidos foram submetidos à análise estatística através do teste estatístico não paramétrico de Kruskal-Wallis. Na margem gengival houve maior microinfiltração no preparo realizado com laser Er:YAG do que com alta rotação com o sistema adesivo Single Bond. Na margem gengival com os preparos de lasers Er:YAG e Er,Cr:YSGG, observou-se menor microinfiltração com a utilização do sistema adesivo autocondicionante One-Up Bond F. A margem incisal não apresentou diferenças nos graus de microinfiltração para todos os tratamentos. / SUMMARY The aim of this research was compare the microleakage degree in the class V gingival and incisal margins using following preparation methods: 1) air turbine, 2) laser Er:YAG Opus 20 (Opus Dent) and 3) laser Er,Cr: YSGG Waterlase model (Millennium, Biolase). Also, the adhesive systems Single Bond (3M ESPE) and One-Up Bond F (Tokuyama) were evaluated. Sixty intact bovine incisives were divided in 6 groups of 10 elements each. The cavities were prepared as follow: groups 1 and 2 using air turbine, groups 3 and 5 laser Er:YAG, groups 4 and 6 laser Er,Cr:YSGG prepare. The specimens were restored with composite resin Z250 (3M ESPE) with previous utilization of the Single Bond (groups 1, 3 and 4) and One-Up Bond F (groups 2, 5 and 6). After storage in distilled water at 37°C, for 24 hours, the specimens were polished, thermocycled and immersed in 50% silver nitrate for 8h. The specimens were included, sectioned in two parts and revealed by means of a 10 min exposure photoflood lamp. The infiltered specimens were evaluated using a stereomicroscope glass with 25X magnification to detect the microleakage degree of each part. The more infiltrate was chosen to represent the individual result of each specimen. Photos were accomplished, and sent to three examinators using the method of scores 0, 1, 2 and 3. The obtained data were submitted to a statistical analysis using the non-parametrical statistic test of Kruskal-Wallis. In the gingival margin there was more microleakage with the prepare accomplished with laser Er:YAG, than that of air turbine with the Single Bond adhesive system. In the gingival margin with the lasers preparations Er:YAG and Er,Cr:YSGG smaller microleakage was observed with the use of self-etching One-Up Bond F adhesive system. The incisal margin did not present differences in the degrees of microleakage for all treatments.
|
577 |
Avaliacao do efeito de corantes especiais e peroxido de hidrogenio irradiados por laser de argonio e laser de diodo no clareamento dental in vitroGASPAR, JOSE A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 1
10001.pdf: 4508519 bytes, checksum: 65261fff2e8d34992f8d1c3a0d09b0d3 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
|
578 |
Irradiacao de dentina cervical radicular com laser de Nd:YAG - Estudo in vitro e microscopia eletronica de varreduraBRITTO, CYNTHIA T.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:43Z (GMT). No. of bitstreams: 1
10194.pdf: 3183980 bytes, checksum: 06ee82fcc1fa34f2eae8829e2a7b8c03 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
|
579 |
Laser de Nd:YAG de alta potência, estabilidade e qualidade de feixe / High power Nd:YAG laser with high stability and beam qualityPINTO, REGIANE de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:16:04Z
No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:16:04Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O trabalho experimental aqui apresentado tem como foco o desenvolvimento de um laser de estado sólido cujo desempenho foi otimizado de tal forma que contemple alta potência, alta qualidade de feixe e estabilidade, levando-se em conta os efeitos térmicos sofridos pelo meio ativo em regime de alta potência de bombeamento. Foram testadas cavidades para operação contínua em multimodo com alta potência de saída e cavidades operando em modo único TEM00. Para cavidades operando no modo fundamental, os ressonadores testados serão divididos em grupos de acordo com o seu comportamento no diagrama de estabilidade. A otimização de tais ressonadores foi realizada apenas alterando-se o raio de curvatura dos espelhos de entrada e saída e suas respectivas distâncias ao plano principal do bastão de Nd:YAG. Como resultado foi alcançada a maior eficiência de extração reportada na literatura para um ou dois módulos de Nd:YAG intracavidade. Os resultados dão uma visão geral sobre possíveis projetos de ressonadores para operação dinamicamente estável, com alta potência de saída e qualidade de feixe. Os dados obtidos servem como base para o desenvolvimento de novos lasers de alta potência e eficiência baseados em módulos DPSSL (Diode-Pumped Solid-State Lasers- Lasers de Estado Sólido Bombeados por Diodo) de baixo custo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP: 12/19118-9
|
580 |
Desenvolvimento de um laser de centros de cor-centros F2 em LiFUDO, PAULO T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:35Z (GMT). No. of bitstreams: 1
02455.pdf: 1496860 bytes, checksum: 707ae6d051d3717f9af83f373858fd65 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.0425 seconds