• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 559
  • 8
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 583
  • 361
  • 199
  • 175
  • 150
  • 145
  • 145
  • 143
  • 106
  • 86
  • 83
  • 82
  • 78
  • 76
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Remoção de enxofre da gasolina em coluna de leito fixo, com uso de adsorventes zeolíticos

Clericuzi, Genaro Zenaide January 2003 (has links)
Made available in DSpace on 2014-06-12T17:42:21Z (GMT). No. of bitstreams: 1 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / A emissão de gases tóxicos como SOx e derivados de hidrocarbonetos provocados por veículos é a maior fonte de poluição atmosférica. A formação de SOx na combustão pode levar a altas taxas de corrosão e provocar a formação de chuvas ácidas. As especificações com relação aos combustíveis têm se tornado mais rigorosas nos últimos anos devido à necessidade de redução de poluentes de acordo com as agencias de proteção ambiental. O principal processo de remoção de enxofre na indústria de refino de petróleo é o da hidrodessulfurização, que é restrito devido ao alto custo e severidade. Um processo alternativo ao da hidrodessulfurização é a adsorção, pois além de menor custo, apresenta seletividade dos adsorventes para diversos processos de separação. Neste trabalho foram preparados dois adsorventes a partir da zeólita NaY, através de troca iônica com o ZnCl2 sob agitação e controle do pH e da temperatura. Os adsorventes preparados foram secos em estufa a 120oC, durante 12 horas e calcinados em mufla a 600o C por 1 hora. A troca foi realizada a fim de se obter 0,5% e 5% de ZnO incorporado à zeólita. Em seguida, foi realizada a etapa de peletização, com adição de 5% grafita e posterior calcinação nas mesmas condições da preparação dos adsorventes. Os materiais foram então caracterizados por espectrofometria de absorção atômica, difração de raios-X (XRD) e medida de área superficial por adsorção de N2. O estudo da dinâmica de adsorção do propanotiol em ciclohexeno foi realizado usando uma coluna de leito fixo em escala de laboratório, utilizando os adsorventes zeolíticos Zn (0,5%)Y e Zn (5%)Y e o adsorvente comercial Selexsorb. O processo de remoção de enxofre foi acompanhado mediante um Analisador de Enxofre EDX-700, Modelo RayNY, marca Shimadzu. Os dados da dinâmica de adsorção do propanotiol em ciclohexeno para os adsorventes zeolíticos Zn(0,5%)Y e Zn(5%)Y e o adsorvente comercial Selexsorb, foram ajustados segundo um modelo matemático que envolve os efeitos de convecção, dispersão axial e transferência de massa externa. A solução deste modelo foi realizada com aplicação do método de diferenças finitas. Os valores médios dos coeficientes foram dados por Dax = 9,2 x 10-4 cm2 min-1 e KLS = 9x10 6 cm min-1
22

Transferencia de calor mistura-parede em leitos fluidizados recirculantes

Oliveira, Daniel Tostes 24 July 1986 (has links)
Orientador: Cesar Costa Pinto Santana / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T00:16:50Z (GMT). No. of bitstreams: 1 Oliveira_DanielTostes_M.pdf: 2502827 bytes, checksum: b8a8f01418f074ecbc51bbfd1455e2d2 (MD5) Previous issue date: 1986 / Resumo: Neste trabalho foi analisada a influência da concentração, natureza e tamanho das particulas na determinação coeficiente de calor convectivo entre misturas gás-sólido do eparedes aquecidas em leitos fluidizados com altas velocidades do ar e recirculação das particulas sólidas. O conjunto dos resultados experimentais conduziu a uma correlação adimensional para previsão do número de Nusselt em função da concentração volumétrica de sólidos, número de Reynolds das partículas e de propriedades físicas e de transporte dos sólidos e do ar. Em virtude da faixa de concentração de sólidos estudada se situar entre as regiões do leito fluidizado comum e do transporte pneumático, e para efeito do âmbito de validade da correlação desenvolvida, seu desempenho foi comparado com outras de ampla aceitação da literatura, válidos para o leito fluidizado borbulhante e para o transporte pneumático em fase diluída. Paralelamente, foram encontrados outros parâmetros , para a correlação do coeficiente de transferência de calor, a partir de diferentes métodos numéricos como os de Regressão Não Linear, visando criar alternativas para a análise dos coeficientes obtidos. / Abstract: This work involved the analysis of the influence of volumetric concentration, nature and size of solid particles on determining the convective heat transfer coeficient between solid-gas: mixtures and heated walls influidized beds with high air velocities and solids recirculation. The experimental results led to a correlation for predicting Nusselt Number as a function of solids volumetric concentration, Reynolds Number based on the particle and physical and transport properties of solids and air. Since the range of solids concentration studied was between the flutdized bed and pneumatic conveying regions and o for the scope of valtdity of the correlation developed here, other published correlations for bubbling fluidized bed and pneumattc conveying in diluted phase were used and allowed the verification of the correlation of this work. Parallel to these studies other parameters were encounteres to correlate the heat transfer coefictent using numerical methods, like the non Linear Regression, in order to create alternative ways of analysing the coeficients obtained. / Mestrado / Mestre em Engenharia Química
23

Processamento contínuo da oxidação catalítica do glicerol em reator de leito gotejante

SOARES, Cícero Henrique Macêdo 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-04T13:22:37Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Cícero Henrique Macêdo Soares.pdf: 3086091 bytes, checksum: 1a4c0a01ace20fdf9a7045038a13c343 (MD5) / Made available in DSpace on 2015-03-04T13:22:37Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Cícero Henrique Macêdo Soares.pdf: 3086091 bytes, checksum: 1a4c0a01ace20fdf9a7045038a13c343 (MD5) Previous issue date: 2013 / ANP / Objetivando o desenvolvimento do processo de oxidação contínua do glicerol em reator de leito gotejante, estudos hidrodinâmicos e testes reativos foram realizados em um reator trifásico de leito fixo. As determinações experimentais da distribuição dos tempos de residência (DTR) e da variância do segundo momento realizadas neste reator (para vazões da fase líquida compreendidas entre 1,54 a 2,68*10-7 m3/s, a 303 K e pressão de 1 atm) contribuíram para a aquisição de alguns parâmetros: a) Número de misturadores, j (18, sistema Glicerol(10%)-O2-Carvão e 10, sistema Glicerol(10%)- Carvão ); b) Coeficiente global de transferência de massa, km (6,97*10-7 m/s, sistema Glicerol(10%)-O2-Carvão e 6,50*10-7 m/s, sistema Glicerol(10%)-Carvão – modelo LIMA FILHO, 1991; 8,60*10-7 m/s, sistema Glicerol(10%)-O2-Carvão e 6,50*10-7 m/s, sistema Glicerol(10%)-Carvão – modelo VAN DEEMTER et al., 1956); c) Dispersão axial líquida, Dax (0,66*10-7 – 5,7*10-7 m2/s, sistema Glicerol(10%)-O2-Carvão e 0,38*10-7 – 2,01*10-7 m2/s, sistema Glicerol(10%)-Carvão); d) Retenção líquida L h = 0,47 – 0,51; e) Perda de carga ΔP/H (1070,34 – 3500,34 Pa/m, sistema Glicerol(10%)- O2-Carvão e 38,22 – 105,32 Pa/m, sistema Glicerol(10%)-Carvão) e outras informações com o auxílio de correlações (fator de molhabilidade e coeficientes de transferência de massa locais). Em outra etapa, foram realizados testes reativos onde utilizou o catalisador Pt(2%)/C nas seguintes condições operacionais: faixa de vazão da fase líquida entre 0,83*10-7 m3/s a 1,54*10-7 m3/s, temperatura variando de 35 a 40ºC e pressão de 1 atm. Os resultados obtidos mostraram um rendimento na faixa de 8,48 a 22,81 %, formação dos ácidos glicérico e tartrônico como produtos e seletividade variando entre 25,67 a 74,32 %, respectivamente. Desenvolveu-se uma modelagem cinética dos dados experimentais e parâmetros cinéticos estimados (k1=1,96*10-5 s-1 e k2=2,33*10-4 s-1), consecutivamente.
24

Estudo analitico e experimental de armazenadores de calor sensivel de leito fluidizado

Moura, Luiz Felipe Mendes de, 1958- 02 May 1985 (has links)
Orientador : Kamal Abdel Radi Ismail / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-17T05:17:08Z (GMT). No. of bitstreams: 1 Moura_LuizFelipeMendesde_M.pdf: 3573580 bytes, checksum: ff7b278dd0fae60966d9d82e8385a2e3 (MD5) Previous issue date: 1985 / Resumo: O principal objetivo deste trabalho é o desenvolvimento de um modelo semi-analítico que descreve e prevê o comportamento dinâmico de armazenadores de calor sensível de leito fluidizado. A partir da análise da equação da energia, aplicada á um volume de controle infinitesimal do leito fluidizado, contendo as duas fases presentes, chega-se a um conjunto de equações diferenciais acopladas que representam a distribuição de temperaturas das partículas sólidas e do fluido ao longo do armazenador e em função do tempo. Este conjunto de equações é, então, resolvido numericamente pelo método iterativo de diferenças finitas. A fim de comprovar a validade do modelo proposto e caracterizar o comportamento de armazenadores fluidizados, foi montada e instrumentada uma bancada de testes para armazenadores fluidizados. Um conjunto de ensaios foi realizado variando-se o material, a quantidade e a dimensão das partículas sólidas, a vazão e a temperatura do líquido. Estes dados experimentais permitiram a avaliação do coeficiente de transferência de calor entre fluido e partículas e da perda de pressão ao longo do leito. As curvas de variação da temperatura do fluido na saída do leito, obtidas através do modelo teórico, foram comparados com as curvas obtidas experimentalmente e mostraram boa concordância, o que comprova a validade do modelo proposto. Obteve-se, finalmente, uma correlação para a transferência de calor em função de grupos adimensionais, que representa os resultados experimentais obtidos. Estes resultados foram comparados com os resultados obtidos por outros investigadores e apresentaram ótima concordância, assegurando a validade da análise experimental adotada / Abstract: The main objective of the present work is the development of semi analytical model, which can describe and represent the dynamical behaviour of fluidized sensible heat storage tanks. From the generalized energy equation, applied to an infinitesimal control volume o~ the fluidized bed, containing the two phase, a set of two coupled differential equations representing the temperature distribution in the solid and the liquid phases along the bed were obtained. These equations were solved numerically using an iterative finite difference technique. In order to establish the validity of the proposed model, an experimental rig was designed and adequately instrumented to test fluidized bed thermal storage systems. The tests included various particles material, bed weight, particle size, fluid mass flow and operational temperatures. From these experiments it was possible to determine the heat transfer coefficient between the solid particles and the fluid as well as the pressure drop along the fluidized bed. Numerical and experimental charging curves were compared and good agreement was found, proving the validity of the proposed model. Finally, a general heat transfer correlation, as a function of dimensionless groups, representing the present results was obtained. The present experimental results and the compiled available data due to previous investigators were compared together showing good agreement and assuring the validity of the adopted experimental analysis / Mestrado / Mestre em Engenharia Mecânica
25

Contribuições para a análise do comportamento fluidodinâmico de um leito vibrofluidizado.

Daleffe, Roger Valeri 25 November 2005 (has links)
Made available in DSpace on 2016-06-02T19:55:43Z (GMT). No. of bitstreams: 1 TeseRVD.pdf: 5637129 bytes, checksum: f862b426d686fd352a79713f21cb585f (MD5) Previous issue date: 2005-11-25 / Vibro-fluidized beds with inert particles as fluidizing medium have been appearing as an innovative technique for drying of suspensions and pastes. Aiming to contribute for the comprehension of phenomena involved in such processes, an investigation of fluid dynamic behavior of a vibro-fluidized (and also of a fluidized) bed with inert particles was carried out in this work. Glycerol was employed to wet the inert particles and then simulate the presence of a liquid paste into the bed. The purpose of the present work is to obtain a detailed investigation of the effects of amplitude, frequency of vibration, dimensionless vibration number, degree of liquid saturation, and of the particle size and density on the fluid dynamic behavior of the bed. The research included also an experimental investigation on the effects of the particle size distribution on the dynamic of inert particles into the fluidized, vibrated and vibro-fluidized beds, with an evaluation of size segregation patterns. The experiments were divided into three groups: in the first one, preliminary fluid dynamics tests were carried out; in the second one, the fluid dynamic behavior of fluidized and vibro-fluidized beds was investigated, and in the last one, the effects of particle size distribution on the dynamics of fluidized, vibrated and vibro-fluidized beds were verified. The experimental apparatus used in the tests was a vibro-fluidized bed constituted of a glass chamber, with a 0.114 m diameter cylindrical section, thickness of 0.003 m and height of 0.50 m. Ballotini spherical glass beads (ρp =2,500 kg/m3), with mean diameters from 1.10x10-3 to 17.00x10-3 m, polypropylene spheroids (ρp = 935 kg/m3) with mean diameters of 2.60x10-3 and 3.67x10-3 m and elliptical cylinders of polystyrene (ρp = 1,050 kg/m3) with equivalent diameter (volumetric diameter) of 2.51x10-3 m, were used as inert particles. The bed was operated under dimensionless vibration numbers from 0.00 to 6.00, for amplitudes varying from 0.000 to 0.021 and frequencies of vibration from 0.00 and 18.20 Hz. Glycerol saturation degrees (defined as the ratio between volume of glycerol and volume of voids in the fixed bed) varied from 0.0000 and 0.0072. The glycerol was employed to simulate the presence of a liquid fed into the bed in a batch mode, since it practically does not evaporate under the conditions of present work. Identical values of dimensionless vibration numbers (Γ) were obtained using different combinations of amplitudes (A) and frequencies of vibration (f), aiming to verify the universality of such a parameter to describe vibration characteristics of a vibro-fluidized bed. Four types of size distribution models were used in the investigation of the effects of the particle size distribution on the dynamics of vibro-fluidized beds: binary, flat, Gaussian and a reference one, all of them with a mean Sauter diameter of 2.18x10-3 m. In the range of experimental conditions investigated, it was observed that the dimensionless vibration number does not fully characterize the fluid dynamic behavior of the vibrated systems. Some degree of particle agglomeration was always observed in the presence of glycerol, yielding to an irregular and poor fluidization. The use of vibration in such cases improved the particle circulation in the bed, thus reducing the agglomeration and minimizing the formation of channelling. When specific particle size distributions were adopted for fluidization, some size segregation pattern was observed in almost every case. In the fluidized bed, the smallest particles stayed at the top of the column, while in the vibrated one the largest particles tended to concentrate at the top. In a vibro-fluidized bed under short amplitude of vibration (0.003 m), some segregation was noted but in a less extent than that observed in the fluidized bed at similar conditions. At high amplitude of vibration (0.009 m), no size segregation was detected. / Os leitos vibrofluidizados que utilizam partículas inertes como meio para fluidização estão se destacando como uma nova alternativa para a secagem de pastas e suspensões. A fim de contribuir para a compreensão dos fenômenos envolvidos neste processo, neste trabalho foi efetuada uma investigação do comportamento fluidodinâmico do leito vibrofluidizado (e fluidizado), constituído de partículas inertes e utilizando o glicerol para simular a presença de um líquido. O propósito desta pesquisa é efetuar uma investigação detalhada dos efeitos da amplitude, da freqüência, do adimensional de vibração, do grau de saturação de líquido, do tamanho e da densidade das partículas inertes sobre o comportamento fluidodinâmico do leito. De forma complementar, realizar um estudo experimental da influência da distribuição granulométrica sobre o comportamento dinâmico das partículas inertes no leito fluidizado, vibrado (sem escoamento de ar) e vibrofluidizado, avaliando-se também o fenômeno da segregação. Os experimentos foram divididos em três conjuntos: no primeiro realizou-se ensaios fluidodinâmicos preliminares; no segundo, analisou-se o comportamento fluidodinâmico do leito fluidizado e vibrofluidizado e, no terceiro, estudou-se o efeito da distribuição de partículas sobre a dinâmica dos leitos fluidizado, vibrado e vibrofluidizado. O equipamento utilizado foi um leito vibrofluidizado composto por uma câmara de vidro, com seção circular de 0,114 m de diâmetro, 0,50 m de altura e 0,003 m de espessura. As partículas inertes utilizadas nos ensaios fluidodinâmicos preliminares foram esferas de vidro do tipo ballotini (ρp = 2.500 kg/m3), com diâmetros médios entre 1,10x10-3 e 17,00x10-3 m, esferóides de polipropileno (ρp = 935 kg/m3) com diâmetros médios de 2,60x10-3 e 3,67x10-3 m e cilindros elípticos de poliestireno (ρp = 1.050 kg/m3) com diâmetro equivalente (da esfera de mesmo volume) de 2,51x10-3 m. O leito foi operado com adimensionais de vibração entre 0,00 e 6,00, para amplitudes entre 0,000 e 0,021 m, freqüências entre 0,00 e 18,20 Hz e graus de saturação de glicerol (volume de glicerol por volume de poros no leito estático) entre 0,0000 e 0,0072. O glicerol foi utilizado para simular a presença de líquido alimentado em batelada, uma vez que este praticamente não evapora nestas condições experimentais. Idênticos valores de adimensionais de vibração (Γ) foram obtidos utilizando diferentes combinações entre amplitudes (A) e freqüências (f) de vibração, com o objetivo de verificar sua universalidade para descrever as características de vibração de um leito vibrofluidizado. No estudo do efeito da distribuição de partículas sobre a dinâmica do leito fluidizado, vibrado e vibrofluidizado, foram utilizadas quatro distribuições de partículas (binária, plana, gaussiana e de referência), com diâmetros médios de Sauter de 2,18x10-3 m. No intervalo de condições experimentais utilizadas nos experimentos fluidodinâmicos, observou-se que isoladamente o adimensional de vibração não representou de maneira única o comportamento fluidodinâmico do sistema. Em todos os casos onde estava presente o glicerol, constatou-se a ocorrência de algum nível de aglomeração das partículas, tornando a fluidização de má qualidade e irregular. A vibração nestes casos melhorou a movimentação das partículas, minimizando a aglomeração e atenuando a formação de canais preferenciais. Quando foi empregada uma distribuição de partículas no leito, observou-se de uma forma global a ocorrência de segregação em quase todos os casos. No leito fluidizado, houve a migração das partículas menores para parte superior do leito, no vibrado ocorreu a migração das partículas maiores para parte superior do leito. Para o leito vibrofluidizado submetido à uma baixa amplitude de vibração (0,003 m) houve segregação, mas em menor quantidade que no leito fluidizado, enquanto que, quando submetido à alta amplitude de vibração (0,009 m), não ocorreu a segregação granulométrica.
26

Qualificação de calcários brasileiros quanto à absorção de SO2 em leito fluidizado para condições típicas de combustão de carvão / not available

Camargo, Fernando de Lima 16 April 2001 (has links)
As grandes taxas de consumo de calcário são uma característica problemática em relação à absorção de enxofre na combustão de carvão em leito fluidizado. O conhecimento da conversão e das taxas de reação é um fator chave para a redução do consumo, permitindo uma utilização mais eficiente e uma melhor seleção dos absorventes. Neste trabalho a conversão e o coeficiente da taxa de reação global para a absorção de enxofre por diferentes calcários são determinados num reator de leito fluidizado de escala reduzida. O reator é uma coluna de 160 mm de diâmetro interno, utilizando areia como material do leito, e fluidizado por ar pré-aquecido em 750 e 850ºC. Uma fração de SO2 é adicionada ao ar de fluidização, e bateladas de calcário são alimentadas no leito para a remoção de enxofre. O tamanho médio das partículas de areia e de calcário é de 545 &#956m. As temperaturas, o tamanho das partículas e a fração de SO2 no gás são típicos do processo de combustão de carvão em leito fluidizado. Quando as bateladas de calcário são alimentadas no leito previamente aquecido, as concentrações transientes de saída de SO2, CO2 e O2 são monitoradas continuamente no tempo com a temperatura do processo. Cinco calcários de três regiões diferentes foram testados, sendo dois calcíticos, dois dolomíticos e um magnesiano. Os resultados mostraram que o calcário dolomítico, relativamente mais jovem em relação a sua idade geológica, foi o que apresentou uma melhor eficiência para a remoção de SO2. / The high rates of consumption of limestone is a problematic feature regarding sulfur absorption in coal fluidized bed combustion. The knowledge of conversion and reaction rates is a key factor towards reducing that consumption, allowing a more efficient utilization and a better selection of absorbents. In this work the conversion and the global reaction rate coefficient for sulfur absorption by different limestones are determined in a bench scale fluidized bed reactor. The reactor is a 160 mm internal diameter column using silica sand as bed material, fluidized by pre-heated air at 750°C and 850°C. A fraction of SO2 is added to the fluidization air, and batches of limestone are fed to the bed to perform sulfur removal. The mean particle size of both silica sand and limestone is of 545 &#956m. The considered temperatures, particle size and fraction of SO2 in the gas of the bed are typical of the coal fluidized bed combustion process. As the batches of limestone are fed to the previously heated bed, the exit transient concentrations of SO2, CO, CO2 and O2 are continuously recorded alongside with the process temperature. Five different limestones were tested, including two calcitic, two dolomitic and one magnesian. The results show that the dolomitic limestone, relatively younger regarding its geological age, presented a better efliciency for SO2 removal.
27

Sistema leito cultivado para tratamento de águas residuárias voltado para o reúso não potável em residências unifamiliares do Distrito Federal

Medeiros, Lídia Batista Pereira 24 July 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2018. / A falta de água é um fator limitante para o desenvolvimento urbano, industrial e agrícola das cidades. O reúso de águas em edificações possui um grande potencial para conservação dos recursos hídricos, quando são considerados os usos não potáveis, pois o custo de tratamento para água não potável é menor, quando se considera altos padrões de qualidade que precisam ser atingidos para obter água potável. Ao considerar uma tecnologia alternativa para tratamento de águas residuárias e produção de água de reúso para usos não potáveis, esta pesquisa analisou o potencial de redução de consumo de água utilizando sistemas leitos cultivados (SLC) em residências unifamiliares de diferentes regiões administrativas (RA), simulando a demanda em dois cenários para usos não potáveis e compondo modelos representativos (MRs) dessas edificações considerando: i) renda familiar; ii) tipologia residencial; iii) presença de área de jardim; e iv) consumo per capita de água. Os MRs compostos foram classificados em MR1: renda alta; MR2: renda média alta; e MR3: renda baixa. O sistema foi composto por fossa séptica para realização do tratamento primário, com remoção de 42% de DBO, leito cultivado de fluxo vertical, com remoção de 43% de DBO e leito cultivado de leito horizontal, com remoção de DBO de 87%. O sistema prevê alcançar concentração de DBO de 30 a 20 mg/L para os usos finais de irrigação, lavagem de pisos e descarga sanitária, em cada um dos cenários. O dimensionamento obtido do SLC obteve a maior área de 10,00 m² para o MR1 no cenário 2 e 6,15 m² para o MR3, no cenário 1. O cenário 2 promoveu maior economia na redução do consumo, chegando a 28%, enquanto que no cenário 1 a maior economia foi de 16%. Através deste estudo pôde-se comprovar que os SLC são uma tecnologia de tratamento de águas residuárias possíveis para serem instalados em residências unifamiliares do DF em 19 regiões administrativas. / The lack of water is a limiting factor for the urban, industrial and agricultural development of cities. The reuse of water in buildings has a great potential for the conservation of water resources, when the non-potable uses are considered, because the cost of treatment for non-potable water is less, when it considers high standards of quality that need to be get clean water. When considering an alternative technology for wastewater treatment and reuse water production for non-potable uses, the present study analyzed the potential of reducing water consumption using wetland constructed (WC) in single family dwellings in different administrative regions (RA), simulating the demand in two scenarios for end-uses non-potable and composing representative models (MRs) of these buildings considering: i) family income; ii) residential typology; iii) presence of garden area; and iv) per capita water consumption. The composite MRs were classified in MR1: high income; MR2: high average income; and MR3: low income. The system was composed of septic tank for primary treatment, with 42% removal of BOD, bed vertical flow bed, with 43% removal of BOD and horizontal bed, with BOD removal of 87%. The system predicts a BOD concentration of 30 to 20 mg/L for the end-uses of irrigation, floor washing and sanitary discharge in each scenario. The SLC obtained the largest area of 10.00 m² for MR1 in scenario 2 and 6.15 m² for MR3, in scenario 1. Scenario 2 promoted a greater saving in consumption, reaching 28%, while that in scenario 1 the largest economy was 16%. Through this study it was possible to prove that the SLC are a technology of wastewater treatment possible to be installed in single-family residences of the DF in 19 administrative regions.
28

Proposição e avaliação de tecnologia de produção de pó solúvel de yacon.

ROCHA, R. L. 28 February 2018 (has links)
Made available in DSpace on 2018-08-01T23:19:02Z (GMT). No. of bitstreams: 1 tese_10550_Resumo da Dissertação Final de Mestrado - Rovena Lebarch Rocha pdf..pdf: 25276 bytes, checksum: ecb553d4085628ef9bdd308dfb56bd3c (MD5) Previous issue date: 2018-02-28 / Pesquisas comprovam que o uso do yacon e derivados trazem benefícios à saúde humana, como melhoria da saúde intestinal, redução dos fatores de risco associados à diabetes, aumento da absorção de minerais, redução de triglicerídeos hepáticos e do ganho de peso e melhoria da resposta imune. Esses benefícios estão relacionados, principalmente, a alta concentração de FOS. Por possuir alto teor de água e, consequentemente, alta perecibilidade, a secagem do yacon trata-se de uma tecnologia eficiente por aumentar a vida útil do produto. Dentre os métodos de secagem, a secagem em leito de espuma apresenta como vantagens o menor tempo de execução, emprego de baixas temperaturas e preservação da qualidade nutricional do alimento. Desse modo, os objetivos deste trabalho foram avaliar as características físico-químicas do pó solúvel de polpa de yacon, obtido por meio da secagem de leito em espuma a 60 ºC e verificar a aceitação sensorial do pó reconstituído. Para condução dos experimentos foi adotado o Delineamento Composto Central Rotacional, a fim de investigar as concentrações ideias dos agentes espumantes Emustab® e Whey Protein na produção da espuma da polpa de yacon. Para definição ótima da concentração dos agentes espumantes foi utilizado uma função desejabilidade considerando as seguintes variáveis respostas, para: (a) espuma: massa específica e índice de coalescência; (b) pó solúvel: teor de água, solubilidade, molhabilidade e fibra solúvel; (c) secagem: tempo de secagem; e (d) análise sensorial do pó reconstituído: aceitação sensorial. Complementando os estudos foram modeladas a cinética da secagem em leito de espuma da polpa de yacon. Constatou-se que os efeitos dos agentes espumantes na produção da espuma de polpa de yacon foram significativos para o índice de coalescência, massa específica e tempo de secagem, molhabilidade, solubilidade, teor de água dos pós e aceitação sensorial (aroma, cor, sabor e impressão global) do pó reconstituído. O modelo de Midili foi o que propiciou melhor ajuste para descrever as curvas de secagem. Verificou-se que a concentração dos agentes espumantes 4,62% de Emustab® e 0,48% Whey Protein propiciou o maior índice de desejabilidade global (0,9503). O pó obtido com a concentração ótima dos agentes espumantes apresentou boa solubilidade e boa aceitação sensorial (sabor, aroma e impressão global). O conteúdo de FOS no processamento do pó de polpa de yacon manteve-se alto.
29

Escoamento laminar em condutas anelares com leito de aparas

Rocha, Nuno Emanuel da Costa January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010
30

Escoamento laminar em condutas anelares com rotação interior e leito de aparas

Sarmento, Filipe Alexandre Veiga January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2010

Page generated in 0.0349 seconds