• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 5
  • Tagged with
  • 12
  • 12
  • 12
  • 8
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do solvente no desempenho de separações quirais em leito móvel simulado

Ribeiro, António Manuel Esteves January 2010 (has links)
Tese financiada por FCT/POCTI, União Europeia-FEDER / Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto, Escola Superior de Tecnologia e Gestão. Instituto Politécnico de Bragança. 2010
2

Advances in simulated moving bed : new operating modes : new design methodologies and product (FlexSMB-LSRE) development

Gomes, Pedro Miguel de Sá January 2009 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 2009
3

Produção biotecnológica de sorbitol e ácido lactobiónico com separação simultânea em sistema de leito móvel simulado

Pedruzzi, Israel January 2010 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 2009
4

Estudo da transferência de massa em unidades de leito movel simulado reativo

Silva, Eduardo Alberto Borges da January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Química. / Made available in DSpace on 2012-10-22T04:11:05Z (GMT). No. of bitstreams: 0 / A tecnologia de Leito Móvel Simulado (LMS) tem sido recentemente aplicada em processos envolvendo reações químicas. Na Unidade de Leito Móvel Simulado Reativo, a reação química e a separação de reagentes e produtos ocorrem simultaneamente na unidade. A unidade de leito móvel simulado reativo permite obter simultaneamente elevada pureza dos produtos e alta conversão dos reagentes, mesmo nos casos de reações limitadas pelo equilíbrio termodinâmico. Isto a qualifica potencialmente para aplicação em reações reversíveis, além de ser vantajosa ainda em situações que incluem a remoção de inibidores e venenos catalíticos para melhoria do rendimento da reação principal. Considerando a complexidade da dinâmica de um processo empregando unidades de leito móvel simulado reativo, a formulação matemática e a simulação numérica são ferramentas que têm ganho considerável atenção, não apenas por permitir a compreensão e análise teórica do sistema, mas também devido a uma significativa economia: em material (reagentes, catalisadores, solventes,...) e em tempo de projeto e otimização da unidade. Neste trabalho desenvolve-se um modelo matemático para o processo de reação e separação no LMS reativo sendo o meio poroso caracterizado por mais de um comprimento de escala, que envolve o maior comprimento de escala associado às colunas de leito fixo que compõem a unidade até o menor comprimento de escala associado aos sítios de adsorção. As equações de conservação governantes do processo são tratadas pela aplicação do método da média no volume, de forma que a informação sobre a velocidade de adsorção na microescala possa compôr a equação resultante na macroescala, que é a escala de projeto. Com a metodologia da média no volume, coeficientes efetivos de transporte foram calculados teoricamente e mostraram boa concordância com dados apresentados na literatura. Através de levantamentos experimentais e da resolução das equações da formulação matemática, foi possível verificar a viabilidade do processo de isomerização de glucose em unidades de LMS reativas. Foi também avaliada a influência de parâmetros importantes, de ordem operacional, de transferência de massa e de reação, no comportamento e desempenho da unidade reativa nos processos de isomerização de glucose e inversão de sucrose.
5

Process intensification for the green solvent ethyl lactate production based on simulated moving bed and pervaporation membrane reactors

Pereira, Carla Sofia Marques January 2009 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 2009
6

Separation/reaction in simulated moving bed : Application to the production of industrial sugars

Azevedo, Diana Cristina Silva de January 2001 (has links)
Dissertation submitted for obtain the degree of Doctor in Chemical Engineering, at the Faculdade de Engenharia da Universidade do Porto, under supervisory Dr. Alírio Egídio Rodrigues
7

Molecular simulation of adsorptive processes

Granato, Miguel Angelo January 2008 (has links)
Tese de doutoramento. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
8

Simulated moving bed separators/reactors : application to the synthesis of 1,1- dibutoxyethane (DBE)

Graça, Nuno André Barbosa dos Santos January 2012 (has links)
Tese de Programa Doutoral. Engenharia Química e Biológica. Universidade do Porto. Faculdade de Engenharia. 2012
9

Desenvolvimento e avaliação de novas abordagens de modelagem de processos de separação em leito móvel simulado / Development and evaluation of new approaches to modeling of the separations process in simulated moving bed

Anderson Luis Jeske Bihain 10 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias. / Simulated Moving Bed (SMB) is a very efficient process in the compounds separation by adsorption, because works in a continuous regime, and with countercurrent flow of the solid phase. Among different applications, SMB has stood out in the petrochemical products separation and mainly in the separation of racemic compounds, which are separations of a high degree of difficulty. In this work, two new approaches to modeling the LMS process have been proposed, stepwise approach and Front Velocity approach. In the Stepwise approach, each chromatographic column of the SMB, is divided in to N cells connected in series, and the concentrations of compounds in liquid and solid phases were simulated using two different kinetics of mass transfer. This approach assumes that the interactions resulting from the mass transfer between the molecules of the compound in its liquid and solid phases occur only on the surface. So that with this assumption the volume occupied by each molecule in the solid and liquid phases is the same, implying that the factor of residence is equal to the equilibrium constant. To describe the mass transfer that occurs in the Chromatographic process, the Front Velocity approach considers that the convection is the dominant phase in the solute transport along the chromatographic column. The "Front Velocity" is a discrete model (steps) where the flow rate determines the liquid phase advance along the column. The steps are: advancing liquid phase and subsequent mass transfer between the liquid and solid phases, the latter in the same time interval. Thus, the experimental volumetric flow is used for the discretization of the control volume moving along the porous column with the same velocity of the liquid phase. The mass transfer was represented by two distinct kinetic mechanisms without (linear type) and with maximum adsorption capacity (Langmuir type). Both proposed approaches were studied and evaluated by comparison with experimental data separation LMS of the anesthetic ketamine and subsequently with the drug Verapamil. Were also compared with the simulations of dispersive equilibrium model for the case of ketamine used by Santos (2004) and the simulations of the software Help for the case of Verapamil (Perna 2013). In the chromatographic column characterization step, the new approaches have been associated with inverse R2W tool to determine the global mass transfer parameters using only the experimental residence times of each enantiomer in the high performance liquid chromatography (HPLC) column. In the second step, the kinetic models developed in both approaches were applied to the columns of the LMS with the values determined in the characterization of the chromatographic column step, for the simulation of continuous separation process. The simulation results show good agreement between the two proposed approaches and pulse experiments to characterize the column in the enantiomeric separation of ketamine over time. In the simulation of the SMB process, when the approaches admit one kinetic mechanism of the Langmuir type showed good agreement with the results obtained from the dispersive equilibrium model, it is a classical tool for the simulation of this process. While using a kinetic linear mechanism the results is more similar to the experimental data. According to the study conducted, both the proposed approaches were shown to be potential tools to predict the chromatographic behavior of a sample in a test pulse, as well as the simulation of separation of a compound in SMB process despite minor discrepancies presented in the first work cycles of the SMB. Moreover, the approaches can be easily programed and applied in the analysis of the process, because it requires a low number of parameters and consist of ordinary differential equations.
10

Desenvolvimento e avaliação de novas abordagens de modelagem de processos de separação em leito móvel simulado / Development and evaluation of new approaches to modeling of the separations process in simulated moving bed

Anderson Luis Jeske Bihain 10 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias. / Simulated Moving Bed (SMB) is a very efficient process in the compounds separation by adsorption, because works in a continuous regime, and with countercurrent flow of the solid phase. Among different applications, SMB has stood out in the petrochemical products separation and mainly in the separation of racemic compounds, which are separations of a high degree of difficulty. In this work, two new approaches to modeling the LMS process have been proposed, stepwise approach and Front Velocity approach. In the Stepwise approach, each chromatographic column of the SMB, is divided in to N cells connected in series, and the concentrations of compounds in liquid and solid phases were simulated using two different kinetics of mass transfer. This approach assumes that the interactions resulting from the mass transfer between the molecules of the compound in its liquid and solid phases occur only on the surface. So that with this assumption the volume occupied by each molecule in the solid and liquid phases is the same, implying that the factor of residence is equal to the equilibrium constant. To describe the mass transfer that occurs in the Chromatographic process, the Front Velocity approach considers that the convection is the dominant phase in the solute transport along the chromatographic column. The "Front Velocity" is a discrete model (steps) where the flow rate determines the liquid phase advance along the column. The steps are: advancing liquid phase and subsequent mass transfer between the liquid and solid phases, the latter in the same time interval. Thus, the experimental volumetric flow is used for the discretization of the control volume moving along the porous column with the same velocity of the liquid phase. The mass transfer was represented by two distinct kinetic mechanisms without (linear type) and with maximum adsorption capacity (Langmuir type). Both proposed approaches were studied and evaluated by comparison with experimental data separation LMS of the anesthetic ketamine and subsequently with the drug Verapamil. Were also compared with the simulations of dispersive equilibrium model for the case of ketamine used by Santos (2004) and the simulations of the software Help for the case of Verapamil (Perna 2013). In the chromatographic column characterization step, the new approaches have been associated with inverse R2W tool to determine the global mass transfer parameters using only the experimental residence times of each enantiomer in the high performance liquid chromatography (HPLC) column. In the second step, the kinetic models developed in both approaches were applied to the columns of the LMS with the values determined in the characterization of the chromatographic column step, for the simulation of continuous separation process. The simulation results show good agreement between the two proposed approaches and pulse experiments to characterize the column in the enantiomeric separation of ketamine over time. In the simulation of the SMB process, when the approaches admit one kinetic mechanism of the Langmuir type showed good agreement with the results obtained from the dispersive equilibrium model, it is a classical tool for the simulation of this process. While using a kinetic linear mechanism the results is more similar to the experimental data. According to the study conducted, both the proposed approaches were shown to be potential tools to predict the chromatographic behavior of a sample in a test pulse, as well as the simulation of separation of a compound in SMB process despite minor discrepancies presented in the first work cycles of the SMB. Moreover, the approaches can be easily programed and applied in the analysis of the process, because it requires a low number of parameters and consist of ordinary differential equations.

Page generated in 0.0504 seconds