• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização das ligas Ni-Ti-Mo, Ni-Ti-Ta e Ni-Ti-Mo-Zr obtidas por moagem de alta energia e prensagem a quente

Pereira, Gilda Maria Cortez [UNESP] 21 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-21Bitstream added on 2014-06-13T19:55:26Z : No. of bitstreams: 1 pereira_gmc_me_guara.pdf: 6912618 bytes, checksum: dd31e7ca80bfc105a171d6f3233f2537 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Brasil ainda não produz a liga Ni – Ti em escala comercial, importando grande parte dos produtos à base de Ni – Ti voltados à área médica. O grande custo envolvido na importação destes produtos estimula a tentativa de desenvolvimento nacional desta liga. Assim, esta pesquisa objetivou a caracterização de ligas Ni-Ti-Mo, Ni-Ti-Ta e Ni-Ti-Mo-Zr produzidas por meio de moagem de alta energia e subseqüente prensagem a quente. A caracterização dos produtos moídos e prensados a quente foi realizada por meio de microscopia eletrônica de varredura, difração de raios X, espectrometria por dispersão de energia. Os resultados indicaram que a formação dos compostos intermetálicos, como o Ni3Ti, NiTi e NiTi2, ocorreram nos estágios iniciais de moagem. Em todas as misturas constituídas de pós, os tamanhos de suas respectivas partículas foram aumentados, e a distância entre as lamelas foram reduzidas para longos períodos de moagem. Este fato ocorreu devido ao mecanismo de solda fria entre as partículas dúcteis, que foram totalmente revestidas em suas superfícies esféricas. O rendimento da mistura de Ni-Ti-Mo, Ni-Ti-Ta e Ni-Ti-Mo-Zr aumentou após a moagem molhada. A prensagem a quente contribuiu para a obtenção de estruturas homogêneas e a consolidação dos pós de Ni-Ti-Mo, Ni-Ti-Ta e Ni-Ti-Mo-Zr moídos. No caso das ligas Ni-45Ti-5Mo e Ni-40Ti-10Mo, o composto Ni-Ti foi identificado na estrutura de ambas as ligas, enquanto que as fases Ni3Ti e NiTi2 foram formadas nas microestruturas das ligas Ni-45Ti-5Mo e Ni-40Ti-10Mo. Estas fases intermetálicas dissolveram teores de molibdênio inferiores a 2,1 %-at. Além disso, foi encontrada a presença de precipitados ricos em molibdênio com teores (%-at) próximos de 16Ni-25Ti-59Mo.Não foi encontrada variação significativa dos valores médios de dureza Vickers relacionadas a estas ligas ternárias, após o aumento da... / The Brazil not yet product the Ni – Ti alloy commercially, importing the most products of the Ni-Ti of the medical area. The high cust to wrap up in the importation this products encourage the development national this alloy. In this way, this work aimed the characterization of Ni-Ti-Mo, Ni-Ti-Ta and Ni-Ti-Mo-Zr alloys produced by high-energy ball milling and subsequent hot pressing. The milled and hot-pressed materials were characterized by, scanning electron microscopy, X-ray diffraction, energy dispersive spectrometry. Results indicated that the formation of intermetallic compounds such as Ni3Ti, NiTi and NiTi2 occurred at the initial milling stages. For all the powder mixtures, it was noted that the powder sizes were increased and the distance between lamellas were reduced for longer milling times. This fact occurred due to excessive cold welding mechanism between ductile particles, which were coated fully the vial and balls surfaces. The yield of Ni-Ti-Mo, Ni-Ti-Ta and Ni-Ti-Mo-Zr powders was increased after wet milling. The hot pressing of milled Ni-Ti-Mo, Ni-Ti-Ta and Ni-Ti-Mo-Zr powders contributed for obtainment of homogeneous structures containing amounts of pores lower than 1%. In Ni-45Ti-5Mo and Ni-40Ti-10Mo alloys, the NiTi compound was identified in structure of both the alloys while that the Ni3Ti and NiTi2 were formed in microstructures of the Ni-45Ti-5Mo and Ni-40Ti-10Mo, respectively. These intermetallic phases dissolved molibdenum contents lower than 2.1 at-%. Moreover, it was noted the presence of Mo-rich precipitates with contents close to 16Ni-25Ti-59Mo (at-%). No significant variation of average Vickers hardness values was noted in Ni-Ti-Mo alloys for increased Mo addition up to 10 at-%. In Ni-Ti-Ta alloys, the NiTi and Ni3Ti phases were formed in microstructures of the hot-pressed Ni-48Ti-2Ta and Ni-45Ti-5Ta alloys, while that the Ni3Ti phase was found in ... (Complete abstract click electronic access below)
2

Efeito do oxigênio intersticial nas propriedades mecânicas e biocompatibilidade da Liga Ti-5Ni

Cascadan, Daniela [UNESP] 10 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-10Bitstream added on 2014-06-13T20:07:39Z : No. of bitstreams: 1 cascadan_d_me_bauru.pdf: 1660084 bytes, checksum: f1924a7f3bbd4a75d15f8d6ec924a8c6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre os materiais avançados que a Ciência e Engenharia de Materiais vêm desenvolvendo estão os biomateriais. Há muito, estes são utilizados para reparar partes do corpo danificadas ou deterioradas, mas em função da enorme complexidade dos tecidos vidos e do organismo como um todo, é comum ocorrerem falhas a curto ou longo prazo. No entando, a demanda por esses materiais tende a aumentar, justificando a importância de mais pesquisas nesta área. Existem muitos dispositivos médicos e odontológicos confeccionados com a liga Ti-Ni em função de suas propriedades de memória de forma, superelasticidade e biocompatibilidade. No entando, o elemento níquel é muito tóxico em níveis elevados. A liga Ti-5Ni é o objeto deste estudo e foi preparada a partir da fusão dos metais precursores, tratada térmica e mecanicamente, além de ser dopada com oxigênio. Em cada condição, foi caracterizada em termos de sua composição química, densidade, difração de raios X e microscopia óptica. Também foram analisadas propriedades como microdureza, módulo de elasticidade e biocompatibilidade. As micrografias mostraram que a microestrutura das amostras são dependentes dos tratamentos térmicos e que propriedades tais como microdureza e módulo de elasticidade sofrem variações de acordo com a microestrutura e quantidade de oxigênio. O refinamento pelo método de Rietveld permitiu averiguar as variações nos parâmetros de rede com a inserção de níquel e oxigênio ao titânio. Foram obtidos resultados satisfatórios nos testes de biocompatibilidade, concluindo que a liga apresenta bom potenciala como biomaterial / Among the advanced materials that are developing by science and materials and materials engineering are the biomaterials. There are a lot, these are used to repair damaged or deteriored parts of the body, but in the function of the enormous complexity of living tissue and organism as a whole, are common failures in the short or long term. However, the demand for these materials tends to increase, justifying the importance of further research in this area. There are many medical and dental devices made with Ti-Ni alloy due to its properties of shape memory, supereslaticity and biocompatibility. However, the nickel element is very toxic at high levels. Ti-5Ni alloy is the object of this study and was prepared from arc-melting and heat mechanically treated, besides being doped with oxygen. In each condition, it was characterized in terms of its chemical composition, density, x-ray diffraction and optical microscopy. Were also examined properties such as microhardness, elasticity modulus and biocompatibility. The micrographies showed that the microstructure of samples is dependent on the heat treatment and properties such as microhardness and elasticity modulus suffer variations according to the microstructure and oxygen amount. Refinement by Rietveld method allowed investigating changes in lattice parameters with the addition of nickel and oxygen to titanium. Satisfactory results were obtained in biocompatibility tests, concluding that the alloy presents good potential as a biomaterial
3

Efeito do tempo de tratamento térmico de fios de NiTi conformados a frio na temperatura final de transformação austenítica

Wiggers, William de Souza January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência e Engenharia dos Materiais, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T22:31:07Z (GMT). No. of bitstreams: 1 294986.pdf: 2679609 bytes, checksum: b14be9aa872a7efc9fddaf2dda4b0a4a (MD5) / As ligas com memória de forma são definidas como uma distinta classe de materiais inteligentes que apresentam duas propriedades únicas: o efeito de memória de forma (EMF) e a superelasticidade. Estas propriedades são atribuídas à transformação de fase que as ligas de memória de forma apresentam em conseqüência da variação da temperatura (EMF) ou aplicação de tensão (superelasticidade). As temperaturas nas quais ocorrem as transformações de fase são parâmetros importantes para as condições de contorno no qual o material será aplicado, apresentando propriedades diferentes para cada fase. O NiTi é o material mais comumente estudado dentre as ligas de memória de forma. De acordo com literatura publicada, o EMF e a superelasticidade podem ser manipuladas por meio da deformação a frio, tratamento térmico ou a combinação de ambos. Dentre os parâmetros do processo de tratamento térmico do NiTi, o tempo é uma variável que exerce forte influência nas propriedades do material tratado. As temperaturas de transformação podem ser capturadas por diferentes técnicas de caracterização. Neste trabalho foi verificada a influência do tempo de tratamento térmico na temperatura final de transformação austenítica (Af) de fios de NiTi conformados a frio. Amostras, na forma de fios fornecidos no estado encruado, foram tratadas termicamente durante patamares de tempo de 20, 30 e 60 minutos a uma temperatura de 500°C. Para fins de comparação, também foram utilizadas amostras não tratadas. Após os tratamentos, o material foi caracterizado mecanicamente via ensaios de carregamento e descarregamento. Foram realizadas análises térmicas por meio de ensaios de calorimetria diferencial exploratória (DSC) e análises dinâmico-mecânica (DMA), com o objetivo principal de caracterizar as temperaturas finais de transformação austenítica. Verificou-se, por meio dos resultados obtidos nos ensaios mecânicos, que as amostras sem tratamento não apresentaram patamares de tensão, diferenciando-se das amostras tratadas. À medida que se aumenta o tempo de tratamento ocorre a redução das tensões de patamares e o aumento da deformação residual. Nas amostras tratadas com 30 e 60 minutos ficou evidenciada a presença da fase R, verificada no ensaio de DSC e de carregamento e descarregamento. Os resultados obtidos por meio dos ensaios de DSC e DMA permitiram identificar que a intensidade da transformação de fase aumenta com o tempo de tratamento, devido à liberação da martensita ancorada na estrutura, aumentando a quantidade de material sujeito à transformação. As tensões aplicadas nas amostras de DMA provocaram um aumento da Af quando comparada com os resultados obtidos nos ensaios de DSC. O tempo de tratamento térmico modifica o comportamento mecânico e a temperatura final de transformação austenítica de fios de NiTi conformados a frio. Estas modificações estão associadas a fenômenos de restauração da estrutura encruada e precipitação de compostos intermetálicos. Alteração do tempo de tratamento pode acarretar em alterações no desempenho e características de componentes fabricados a partir desse material, permitindo a otimização das propriedades para adequação ao uso pretendido.
4

Validação de método experimental para medição do potencial de corrosão de liga metálica em sangue humano in vivo

Serafin, João Daniel May January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Ciências Médicas, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T06:56:26Z (GMT). No. of bitstreams: 1 297680.pdf: 642884 bytes, checksum: 25e9296ea3e9b9cdbb19b6995fcd8d6b (MD5) / Justificativa: Ligas metálicas são utilizadas em dispositivos médicos para uso intravascular, principalmente na forma de stents, endopróteses, filtro de veia cava e coils. Todos os implantes metálicos sofrem corrosão após serem implantados no corpo humano. As propriedades físicas e de superfície desses materiais como seu comportamento corrosivo ainda não foram totalmente elucidadas, sendo este conhecimento fundamental para que seja possível evitar complicações destas ligas metálicas. Objetivo: Descrever um modelo experimental para medição do potencial de corrosão (Ecorr) de uma liga metálica no sangue humano em circulação e in vivo e realizar a medição do Ecorr da liga de NiTi. Desenho do Estudo: Estudo experimental, não controlado, analítico do tipo longitudinal. Métodos: Foi mensurado o Ecorr em seis pacientes submetidos à cirurgia arterial direta onde a aorta abdominal, artéria ilíaca ou artéria femoral foram expostas. Antes de se proceder o clampeamento arterial e a arteriotomia, foi mensurada a diferença de potencial de corrosão do NiTi através de um dispositivo constituído por eletrodos de NiTi e pseudo-eletrodo de Pt, que permanecia em contato com o sangue circulante durante um período de 12 minutos fazendo a medição do Ecorr. Para o uso do pseudo-eletrodo de Pt o dispositivo foi previamente validado em testes in vitro. Resultados: Ecorr da liga de NiTi em sangue humano in vivo e em circulação foi de -227,94 (± 27,76)mV. A medida do coeficiente de correlação intraclasse entre os 6 pacientes apresentaram-se compatíveis entre si. Conclusão: O método descrito para medição do Ecorr mostrou-se reprodutível e confiável, podendo servir de modelo experimental para futuros trabalhos com outras ligas metálicas / Background: Metal alloys are used in the manufacturing of intravascular devices such as stents, endoprosthesis, vena cava filters, and coils. All metallic implants are prone to corrosion after placement into the human body. Since the physical and surface properties of metal alloys are not entirely clear, this knowledge becomes essential to reduce clinical complications related to these implants. Objectives: Describe an experimental model to measure the corrosion potential (Ecorr) of a metal alloy in human blood in circulation and in vivo and perform the measurement of Ecorr NiTi alloy. Study design: Experimental, noncontrolled, analytical, longitudinal study. Methods: The Ecorr was measured in 6 patients who underwent open vascular surgery with exposition of the abdominal aorta, iliac artery, or the femoral artery. Before the arterial clamping and arteriotomy, the NiTi Ecorr was measured by the use of a dispositive constituted of NiTi electrodes and a Platinum (Pt) pseudo-reference electrode which were placed into the human circulation during 12 minutes. The Pt pseudo-reference electrode has been previously validated in vitro testing. Results: The measure of the NiTi Ecorr in the human circulation was -227.94 (± 27.76) mV. The correlation coefficient was compatible among the 6 patients. Conclusion: The reported method to measure the Ecorr was shown to be reproducible and reliable, and it may be used in future research with other metal alloys
5

Desenvolvimento de fibras de microextração em fase sólida com suporte de níquel-titânio eletrodepositado com polipirrol e sua aplicação na determinação de haloanisóis em água e vinho por cromatografia a gás

Roux, Kalya Cravo Di Petro 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-graduação em Química, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T11:16:32Z (GMT). No. of bitstreams: 1 279505.pdf: 1031066 bytes, checksum: 94f8a434fe1679ce3e23c1175591d757 (MD5) / Neste estudo uma liga de NiTi foi utilizada como suporte da fase extratora da técnica de microextração em fase sólida (SPME) como substituto da tradicional e frágil sílica fundida, devido as suas notáveis características como memória de forma e superelasticidade. A liga de NiTi foi utilizada como suporte para eletrodeposição de polipirrol, que agiu como fase extratora. As condições de fabricação da fibra, tais como: tipo de dopante, potencial de eletrodeposição e quantidade de carga, foram otimizadas. A morfologia das diferentes fibras confeccionadas foi avaliada por microscopia eletrônica de varredura, demonstrando que as variáveis avaliadas influenciam na rugosidade, organização das partículas de polipirrol sobre o suporte e na espessura do filme formado. Uma metodologia para determinação de haloanisóis em amostras de água e vinho foi desenvolvida, sendo a separação e detecção realizadas por cromatografia a gás com detector por captura de elétrons (GC-ECD) e GC acoplada ao detector de massas (GC-MS). As principais variáveis que influenciam a eficiência de extração foram otimizadas utilizando planejamento fatorial completo e matriz Doehlert. Alguns parâmetros de mérito foram obtidos com o método otimizado: coeficientes de correlação maiores que 0,996, desvio padrão relativo menores que 16%, exatidão na faixa de 77 a 125% e excelentes limites de detecção (1 a 6 ng L-1). A eficiência de extração da fibra proposta foi comparada com fibras comercialmente disponíveis em termos de limite de detecção e precisão, sendo obtidos excelentes resultados. Propôs-se também a utilização dos halofenóis em suas formas acetiladas como padrões internos para os respectivos haloanisóis, com o objetivo de se sobrepor a efeitos de matriz e facilitar a calibração do método para determinação desses compostos em vinho pela construção da curva de calibração em água. Os efeitos de matriz foram satisfatoriamente corrigidos pelo uso dos padrões internos. A fibra de NiTi eletrodepositado com polipirrol mostrou-se uma alternativa atraente ao uso de fibras comercialmente disponíveis, devido a sua maior robustez e facilidade de preparo. / In this work, a NiTi alloy was used as support for application in SPME as a substitute of the traditional and fragile fused silica core, due to its remarkable features such as shape memory and superelasticity. NiTi wire was used as substrate for electrodeposition of polypyrrole, which was the extraction phase in this case. Fabrication conditions were optimized, such as: type of counter ion, electrodeposition potential and charge quantity. Morphology of the different fabricated fibers was evaluated by scanning electron microscopy, demonstrating that the investigated variables affect rugosity, organization of polypyrrole particles on the NiTi substrate and film thickness. A method for determination of haloanisoles in water and wine samples was developed, being separation and detection performed by gas chromatography with electron capture detector and mass spectrometric detector. The main variables influencing extraction efficiency were optimized using full factorial design and Doehlert matrix. Analytical parameters of merit were obtained with the optimized method: correlation coefficient higher than 0.996, relative standard deviation lower than 16%, accuracy in the range of 77 to 125% and excellent detection limits in the range of 1 to 6 ng L-1. The efficiency of the proposed fiber was compared with commercially available SPME fibers with excellent results. The use of halophenols in their acetylated form as internal standards for the haloanisoles was proposed, aiming at overcoming matrix effects and facilitating method calibration by using aqueous standards. Matrix effects were satisfactorily overcome by using the internal standards. NiTi electrodeposited with polypyrrole has shown to be an attractive alternative to the use of commercially available SPME fibers, due to its higher robustness along with easy and inexpensive preparation.
6

Estudo do uso da liga Ti-50,67at%Ni com efeito de memória de forma na minimização de perdas de pré-carga axial em juntas fixadas por parafusos / Study on the use of Ti-50,67at%Ni alloy with shape memory efect to minimize the axial pre-load loss in bolted joints

Minetto, Roberto Tadeu 16 August 2018 (has links)
Orientador: Jorge Otubo / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T22:36:53Z (GMT). No. of bitstreams: 1 Minetto_RobertoTadeu_M.pdf: 5159616 bytes, checksum: a09b62580c76b0c4d2322045c6ba6a3d (MD5) Previous issue date: 2010 / Resumo: Idealmente, as juntas rigidamente fixadas por parafusos deveriam manter as forças de aperto aplicadas em cada parafuso até o final da vida útil e com um mínimo de variação entre os parafusos de um mesmo conjunto. No entanto, ensaios mecânicos comprovam que a dispersão das forças de aperto, nos processos atuais de fixação do cabeçote de cilindros, é muito grande e que a perda de pré-carga pode chegar a 30%. Ou seja, se aplica 100 kN e ter-se-á efetivamente 70 kN de força resultante após algumas horas de utilização. Esta perda é devido à acomodação (relaxamento) dos picos de usinagem da rosca e da face de assentamento da cabeça do parafuso, das deformações plásticas dos componentes envolvidos, do "endireitamento" parafuso, da velocidade do fuso de aperto, etc. Como o sistema de aperto convencional não usa arruela entre o parafuso e o cabeçote, a proposta deste projeto foi estudar o uso da liga Ti-50,67at%Ni com efeito de memória de forma (superelástico) para a utilização na confecção desta arruela. Uma vez montada no conjunto, a arruela estará sujeita a uma carga de compressão, e, devido ao efeito da memória de forma, o componente tenderá a voltar à forma original minimizando ou mesmo eliminando a perda de carga sofrida pelos parafusos usados na montagem / Abstract: Gaskets rigidly attached by bolts should keep the applied forces to each bolt until the end of its life and presenting a small force variation among the bolts of the same set. However, mechanical tests confirms that the bolt forces dispersion, in the current cylinder head fixation process, is large and the pre load loss reach 30 per cent. It means that if we apply 100 kN, we are going to have 70 kN of resultant bolt forces after few hours of running tests. This loss is caused by machining peaks accommodation in the thread contact and bolt head seating, plastic deformation (thermal and mechanical) of the involved components, bolts beating and others important aspects of bolt torque strategy. As the current system does not use flat washers between the bolt head and cylinder head bosses this project purposes to study the use of Ti-50,67at%Ni alloy, with shape memory effect (superelasticity) , for fabricating this washer. When assembled in the set, the washer will suffer a compressive load and because of the shape memory effect, the component will try to return to the original form, minimizing or even eliminating the pre load loss by bolts used to set / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Automobilistica
7

Analise de falhas de instrumentos endodonticos rotatorios de Ni-Ti em odontologia / Failure analysis of rotary endodontic instruments of Ni-Ti in dentistry

Almeida, Fabiano Costa, 1969- 12 October 2008 (has links)
Orientador: Itamar Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T18:16:51Z (GMT). No. of bitstreams: 1 Almeida_FabianoCosta_M.pdf: 5847726 bytes, checksum: 145c2a03eac9f5421c57057a5a6f9cb6 (MD5) Previous issue date: 2008 / Resumo: Os instrumentos endodônticos rotatórios de Ni-Ti (limas rotatórias) são utilizados para o preparo dos condutos radiculares e apresentam características de memória de forma, alta flexibilidade e geometria variável. Apesar dessas características, quando solicitados no uso clínico endodôntico, algumas vezes, apresentam fratura no interior dos condutos radiculares tendo como conseqüência uma diminuição no período de utilização, alto custo e a presença de iatrogenias. Este trabalho tem por objetivo realizar uma análise de falha de dois tipos de instrumentos endodônticos rotatórios de Ni-Ti, ProTaper® e ProFile® do mesmo fabricante (Dentsply-Tulsa Dental-Suíça), com geometrias diferentes, utilizando algumas limas com falha em serviço, e ensaios de fadiga de limas sem uso, por flexão rotativa, visando a obtenção de referenciais de micromecanismos de fratura. Foram realizadas análises químicas, por Espectrometria de Fluorescência de raios X e por Difração de raios X, metalográfica, por microscopia óptica, e fratográfica, por microscopia eletrônica de varredura, e ensaios de microdureza e de fadiga, por flexão rotativa, nos dois tipos de limas. Os resultados mostraram que as composições químicas dos dois tipos de limas são iguais, contendo, em peso, 58% de níquel e 42% de titânio, sendo possível identificar, por metalografia, duas fases, Ti2Ni (fase secundária) e TiNi (matriz). Os níveis médios de microdureza encontrados foram de 344HV1, para a lima ProTaper, e de 330HV1, para a lima ProFile. A fratografia possibilitou a identificação de duas regiões na superfície de fratura das limas, com fratura em serviço e submetidas aos ensaios de flexão rotativa, uma correspondente à zona de fadiga, e outra, a zona de fratura final, com avéolos ou "dimples". Foi possível concluir que a falha das limas analisadas foi por fadiga. / Abstract: Rotary endodontic instruments of Ni-Ti (rotary files) are used in order to prepare endodontic dental conducts and show memory shape, high flexibility, and different designs. Although these characteristics, when used in endodontics clinic, sometimes occur fracture inside the conduct of the tooth and, as a result of that, low life, high cost, and iatrogen. The propose of this study is to realize a failure analysis of two different endodontic files, ProTaper® and ProFile®, of Ni-Ti, from the same maker and different shapes, by using some files with failure in service, and fatigue test in files, without use, in rotating bend, to obtain references in terms of micromechanisms of fracture. Were realized chemical analysis, by spectrometry of X-Ray fluorescence and X-Ray diffration, metallograthy, by optical microscopy, and fratographic, by scanning electron microscopy, and microhardness and fatigue tests, in the two types of files, ProTaper and ProFile. The results show the chemical composition of the two files are the same, with 58% of nickel and 42% of titanium, in weight, and was possible to identify, by metallography, two phases, Ti2Ni (secondary phase) and TiNi (matrix). The median levels of microhardness were 344HV1, for the ProTaper® file, and 330HV1, for the ProFile® file. It was possible to identify, by scanning electron microscopy, two different regions on the fracture surface of the files, for fracture from service and from the fatigue tests, one correspondent to the fatigue zone, and another, the final fracture, show dimples. It was possible to conclude that the failure of the analyzed files was by fatigue. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Page generated in 0.0724 seconds