Spelling suggestions: "subject:"cozinhas"" "subject:"bolinhas""
161 |
Sistema sensor para detecção de descargas atmosféricas em linhas de transmissão de energia elétricaRodrigo Gomes da Silva Lourenço Novo, Lauro 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T17:35:36Z (GMT). No. of bitstreams: 2
arquivo2473_1.pdf: 3432941 bytes, checksum: 6a43532ec76a9d1331483b7be72c838a (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2009 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presença de descargas atmosféricas, quer seja por incidência direta pelo golpe
(strike) de descarga atmosférica, quer seja indireta, por meio do surgimento de correntes
induzidas nas estruturas das linhas de transmissão, traz grande preocupação às empresas
geradoras e transmissoras de energia elétrica. Essas linhas sofrem, por vezes, desligamentos
provocados por surtos de manobra e surtos atmosféricos. Na situação de ocorrência de
descarga atmosférica, é de interesse identificar sobre qual torre ou vão de L.T. essa descarga
ocorreu com o objetivo de melhorar a qualidade do serviço de manutenção e promover em
tempo hábil o religamento das linhas. Esta dissertação apresenta, assim, a concepção e
construção de um sistema de detecção de descargas atmosféricas sobre uma torre ou um vão
de L.T, determinando a intensidade da corrente de pico da descarga correspondente. Além
disso, um sistema de R.F. foi projetado e construído para transmitir esses dados a um sistema
de recepção. O sistema completo consiste em uma bobina de Rogowski conectada a um
circuito eletrônico condicionador de sinal que, por sua vez, alimenta um circuito eletrônico
microcontrolado, o qual se conecta ao sistema de R.F
|
162 |
Otimização do uso da linha de transmissão através do monitoramento em tempo real / Optimizing the use of transmission lines by real time monitoringCastilho, Renato Maioli 17 August 2018 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-17T05:27:30Z (GMT). No. of bitstreams: 1
Castilho_RenatoMaioli_M.pdf: 2356762 bytes, checksum: ada04c502811c2989682af0e17b5a512 (MD5)
Previous issue date: 2010 / Resumo: Este trabalho apresenta um método de análise do carregamento de linhas de transmissão aérea em tempo real o qual relaciona o respectivo carregamento da linha de transmissão com fatores externos que, direta ou indiretamente, exercem influência sobre os limites de operação da linha. Através da implementação de um sistema de monitoramento em uma linha de 230 kV da
Eletronorte, informações atmosféricas e da própria linha foram coletadas e transmitidas via cabo OPGW para um centro de controle onde, a partir de um software, obteve-se a ampacidade da linha em tempo real. Fazendo uso do banco de dados gerado com as informações coletadas pelo sistema de monitoramento e utilizando técnicas de redes neurais artificiais, foi desenvolvido um módulo preditor da temperatura superficial do cabo, possibilitando estimar a ampacidade da linha no curto prazo. A pesquisa se deu em três fases, na primeira foi feito o desenvolvimento dos equipamentos que compõem o sistema de monitoramento, na segunda fase foi feita a implementação do sistema na linha de 230 kV e na terceira fase foi dado o tratamento matemático às informações coletadas. A abordagem realizada dos dados obtidos pelo sistema de monitoramento proposto gerou resultados interessantes no que tange a busca pelo melhor aproveitamento da linha e mostrou ser um sistema bastante útil para a operação no despacho de carga. O sistema de monitoramento analisado neste trabalho de pesquisa, foi desenvolvido pelo Centro de Pesquisa e Desenvolvimento em Telecomunicações - CPqD em parceria com a Universidade Federal do Pará - UFPA e faz parte do programa de pesquisa e desenvolvimento das Centrais Elétricas do Norte do Brasil S.A. - Eletronorte. / Abstract: This paper presents a method of transmission line load analysis in real time, which relates of the transmission line loading with external factors that directly or indirectly exert influence over the operating range of the line. By setting up a monitoring system in a line of 230 kV, weather and line parameters information were collected and transmitted via OPGW cable to a control center where, using dedicated software, we obtained the ampacity of the line in real time.
Making use of the database generated with information collected by the monitoring
system and using techniques of artificial neural networks, we developed a predictor module surface temperature of the cable, allowing use to estimate the ampacity of the line in the short term. The research was divided in three phases, at first was developed the equipment that make up the monitoring system in the second round was implemented the monitoring system at 230 kV line and in the third stage was given the mathematical treatment of collected information. The data obtained by the proposed monitoring system, has generated interesting results allowing an optimized use of the line the system proved to be very useful for the line loading operation. The monitoring system of loading examined in this research work was developed by the Center for Research and Development in Telecommunications - CPqD in partnership with the Federal University of Pará - UFPA and is part of Centrais Elétricas do Norte do Brasil S.A - Eletronorte research and development program. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
163 |
Simulação numerica de linha de transmissão considerando o efeito pelicularGatous, Omar Mohamed Omar 25 October 1995 (has links)
Orientador: Marcos Andre da Frota Mattos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-21T07:33:15Z (GMT). No. of bitstreams: 1
Gatous_OmarMohamedOmar_M.pdf: 6387648 bytes, checksum: 1ab959854c480a9f6d41d5a0a8e22eda (MD5)
Previous issue date: 1996 / Resumo: Foi desenvolvido um modelo computacional para estudo e análise do efeito pelicular em linhas de transmissão no domínio do tempo. A consideração do efeito peculiar é obtida apartir da olução da equação de Maxwell para o condutor da linha de transmissão.Utilizamos o método numérico de diferenças finitas para analisar as equações do modelo clássico (equações de telegrafista), e as equações do modelo desenvolvido. Nesta análise os valores da tensão ou a corrente do passo seguinte são calculados com base dos valores do passo anterior.Os resultados obtidos pelo modelo desenvolvido são comparados com os do modelo clássico, quando neste utilizamos os parâmetros da freqüência resistência Rw e indutância Lw, e os da corrente continua resistência Rcc e indutância Lcc / Mestrado / Mestre em Engenharia Elétrica
|
164 |
Aplicação de estruturas PBG em dispositivos planares de microondas - linhas e antenas - em substratos dieletricos e semicondutores : desenvolvimento de tecnologia e caracterizaçãoOliveira, Luiz Claudio Marangoni de, 1975- 29 July 2018 (has links)
Orientador: Luiz Carlos Kretly / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T00:00:28Z (GMT). No. of bitstreams: 1
Oliveira_LuizClaudioMarangonide_M.pdf: 3172224 bytes, checksum: 918b3c7430ac9242671c9d8a5a087976 (MD5)
Previous issue date: 2001 / Mestrado
|
165 |
Religamento monopolar adaptativo rapido baseado na assinatura harmonica da tensão de arco secundario / Fast adaptive single-phase autoreclosing based on secondary arc voltage harmonic signatureMontanari, Allan Alves 13 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T12:17:57Z (GMT). No. of bitstreams: 1
Montanari_AllanAlves_M.pdf: 7585929 bytes, checksum: 4c00ba94f40e488cc4da50c4089e8630 (MD5)
Previous issue date: 2009 / Resumo: Este trabalho apresenta um esquema de religamento monopolar adaptativo rápido para
otimizar o tempo compreendido entre a abertura e o religamento da fase sob falta. A proteção
adaptativa recompõe rapidamente o sistema de transmissão de energia elétrica, minimizando a
probabilidade de propagação de perturbações severas no sistema. O método é fundamentado na análise de dados de ensaios de arco secundário gerados e monitorados numa estrutura de testes construída em campo, composta por um trecho real de linha de transmissão (três torres e dois vãos). Analisou-se o conteúdo harmônico da tensão e da corrente de arco secundário através da aplicação da Transformada de Fourier Janelada. Tais análises viabilizaram a realização de um tratamento estatístico para a caracterização da assinatura harmônica de arco secundário.
Simulações de faltas monofásicas foram realizadas utilizando dados provenientes dos
Ensaios de arco secundário. Desenvolveu-se um algoritmo baseado nas características
Harmônicas da tensão da fase sob falta, calculadas através do deslocamento de uma janela de
tempo sobre os sinais analisados (Transformada de Fourier Janelada). O algoritmo determina
a existência do arco secundário e fornece informações a respeito do instante no qual o
religamento pode ser realizado com sucesso. O método apresenta também um mecanismo
para a detecção da característica permanente ou transitória da falta. / Abstract: This work presents a fast adaptive single-phase autorec1osingseheme to optimize the
period between the tripping operation and the rec10sure of the faulted phase breakers. The
adaptive proteetion quiekly reeomposes the eleetric power transmission, minimizing the
probability of severe damages propagation in the system.
The method is based on the analysis of secondary are field tests data that were
generated and monitored in an infra-structure which consists of a real transmission line
section (three towers and two spans). The harmonic content of the secondary are voltage and
eurrent was analyzed by the application of Short Time Discrete Fourier Transform. Such
analysis made it possible to implement a statistical approach in order to obtain the secondary
are harmonic signature.
Single-phase faults computer simulations were performed using the data obtained from
the secondary are tests. It was developed an algorithm based on the voltage harmonic content
of the faulted phase, which was ea1culated by shifting a window on the analyzed signals
(Short Time Discrete Fourier Transform). The algorithm determines the secondary are
existence and provides information in order to suceessfully rec10se the circuit breaker. The
method also presents a control mechanism responsible for identifying whether the fault is a
permanent one or a transient fault. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
166 |
Reuso sistematizado de software e linhas de produto de software no setor financeiro: estudos de caso no Brasil. / Sem títuloSheila dos Santos Reinehr 19 March 2008 (has links)
A engenharia de software tem buscado, nas últimas décadas, assemelhar-se a outras disciplinas de engenharia, introduzindo métodos, técnicas e ferramentas que possibilitem a melhoria da produtividade e qualidade no desenvolvimento de software em ordem de grandeza similar à alcançada pela indústria de manufatura. Uma das abordagens mais bem sucedidas neste sentido tem sido o emprego das práticas de reuso sistematizado de software, como o desenvolvimento baseado em componentes e, em especial, as linhas de produtos de software ou engenharia de família de produtos. No Brasil, um dos segmentos que mais produz e consome software é o setor financeiro, uma vez que todos os seus produtos e serviços são entregues através da tecnologia da informação. Por este motivo, torna-se fundamental a compreensão de como acontecem os processos de reuso de software neste segmento e como estes contribuem para o sucesso dos projetos. Esta pesquisa apresenta o mapeamento do cenário de reuso de software no setor financeiro no Brasil, baseado em estudos de caso conduzidos em cinco, dos dez maiores bancos instalados no país. / During last decades, Software Engineering has been aiming at be more disciplined as other engineering disciplines, by introducing methods, techniques and tools that provide productivity and quality improvement in the same levels reached by manufacturing industries. One of the most successful approaches towards this goal has been the use of systematic software reuse practices, such as component based development and, specially, software product lines or product family engineering. In Brazil, one of the most active sectors in consuming and producing software products is the financial sector, once all of its products and services are delivered through Information Technology. This is the reason why is so important to understand how software reuse processes occurs in this sector and how do they contribute to projects success. This research presents scenario of software reuse in the financial sector in Brazil, based on case research conducted in five of the ten largest banks installed in the country.
|
167 |
Fundações superficiais para linhas de transmissão em argilas moles saturadasSotelo, Ruben Rafael January 1994 (has links)
As fundações empregadas para linhas de transmissão de alta tensão em depósitos de argilas moles saturadas são geralmente estacas. No Rio Grande do Sul, projetos alternativos com fundações superficiais foram empregados em forma experimental para torres de suspensão, as quais apresentaram bom desempenho com menor custo. Esta pesquisa visa apontar critérios racionais da mecânica dos solos que permitam projetar, a partir do conhecimento do perfil de resistência não drenada, fundações superficiais em depósitos de argilas moles saturadas com maior confiabilidade. Para a determinaçao do perfil de resistência não drenada foi desenvolvido um cone manual com leituras elétricas, o qual foi testado apresentando bons resultados. A vantagem do uso deste equipamento reside no fato de que pode ser transportado manualmente a locais de difícil acesso, onde são implantadas as torres de alta tensão. Os demais parâmetros de solos do local de estudo, situado no município de Canoas no Rio Grande do Sul, foram obtidos a partir de ensaios de compressão triaxial do tipo adensado isotropicamente não drenado (CIU) com medida de poro pressão e de ensaios de adensamento. Foram analisadas as fundações superficiais das torres de suspensão projetadas, empregando teorias analíticas convencionais, baseadas no conhecimento da resistência não drenada, e o método de elementos finitos. A partir deste estudo, é sugerida uma metodologia para projetos de fundações superficiais de torres de suspensão em argilas moles saturadas. / Piles are generally used as foundations of power transmission lines in saturated soft clays. Shallow foundations for suspension towers have been experimentally used as an alternative in Rio Grande do Sul State. Satisfactory results at lower costs were achieved. This research attempts to indicate, knowing the undrained shear strength profile, rational soil mechanics criteria for more reliable design of footings in saturated soft clays. In arder to determinate the undrained shear strength profile, a hand electrical cone was developed. This device was tested with good results and presents the advantage of being easily carried to difficult access sites where the towers are installed. A site located in Canoas (Rio Grande do Sul State) was studied. Besides undrained shear strength other parameters were obtained from triaxial compression tests of the CIU type, with pore pressure measurement, and also consolidation tests. Shallow foundations of suspension towers were analyzed using tradtional analytical theories, based in undrained shear strength, and the finite element method. As a result of the research a method is suggested for the design of shallow foundations suspension tower on saturated soft clays.
|
168 |
Analise de estruturas metalicas de torres treliçadas autoportantes para telecomunicaçõesNascimento, Fernanda Otavia Dias Amadio 26 February 2002 (has links)
Orientador : João Alberto Venegas Requena / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-01T13:20:15Z (GMT). No. of bitstreams: 1
Nascimento_FernandaOtaviaDiasAmadio_M.pdf: 4903968 bytes, checksum: 0ed95e2d2a9856ccc21a64428d41e1ba (MD5)
Previous issue date: 2002 / Resumo: Este trabalho apresenta uma análise comparativa das ações estáticas e dinâmicas que agem predominantemente em torres metálicas treliçadas autoportantes para telecomunicações. São apresentados os fundamentos teóricos da análise dinâmica linear, utilizados no desenvolvimento das formulações apresentadas na norma brasileira NBR 6123/87, para obtenção das ações devidas ao vento em edificações. São tratados os aspectos principais das ações de vento que agem na estrutura. Um dos aspectos é baseado na velocidade de rajada de 3 segundos considerado como ação estática. O outro aspecto é baseado na velocidade média de 10 minutos que considera a resposta da estrutura em função das freqüências fundamentais, neste caso tratado como ação dinâmica. Os processos apresentados pela norma brasileira NBR 6123/87, são discutidos e analisados através de resultados obtidos em exemplos numéricos com o objetivo de estabelecer critérios para garantir a segurança das estruturas / Abstract: This work presents a comparative analysis of static and dynamics actions that affect predominantly the latticed self supporting metallic towers for telecommunications. Theoretical foundations concerning to linear dynamic analysis are presented, which are used in the development of formulations presented in the Brazilian standard code NBR 6123/87 to obtain the actions due to the wind acting in constructions. Principal features of wind actions that affect the structure are discussed herein. One of the aspects is based on the velocity of the gust of the wind of 3 seconds considered as static action. The other aspect is based on the medium velocity of 10 minutes that considers the structure response as a result of fundamental frequencies, in this case considered as dynamic action. Processes presented by the Brazilian standard code NBR 6123/87 are discussed. The results obtained in several numerical examples with the purpose of establishing criteria to ensure the security of the structures / Mestrado / Estruturas / Mestre em Engenharia Civil
|
169 |
Antenas planares reconfiguraveis do tipo V - estatico e tipo defasamento de arranjo por matrizes PBG - photonic band gap - para aplicação em telefonia movel celularSilva, Andre Tavora de Albuquerque 02 August 2018 (has links)
Orientador : Luiz Carlos Kretly / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-02T20:45:17Z (GMT). No. of bitstreams: 1
Silva_AndreTavoradeAlbuquerque_M.pdf: 9501140 bytes, checksum: ce77cf30e1b9947562cbb76c7ade1f2f (MD5)
Previous issue date: 2002 / Mestrado
|
170 |
Uma abordagem alternativa para os escalonamentos de onibus e de motoristasVaz, Glauber José, 1978- 03 August 2018 (has links)
Orientadores: Cid Carvalho de Souza, Arnaldo Vieira Moura / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-03T17:13:58Z (GMT). No. of bitstreams: 1
Vaz_GlauberJose_M.pdf: 2026222 bytes, checksum: 3272d1c1a8c5e8941f3b98a19e487be7 (MD5)
Previous issue date: 2003 / Mestrado
|
Page generated in 0.0289 seconds