141

Sistemas para detecção e localização de descargas atmosféricas e perdas de cabos para-raios por furto em linhas de transmissão de energia elétrica

SANTOS, Emmanuel Andrade de Barros 29 May 2013 (has links)
Submitted by Amanda Freitas (amanda.freitas@ufpe.br) on 2015-04-17T13:33:05Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Emmanuel Andrade de Barros Santos.pdf: 5505882 bytes, checksum: 3e253365a0c28b99c3572781dd0849cd (MD5) / Made available in DSpace on 2015-04-17T13:33:05Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Emmanuel Andrade de Barros Santos.pdf: 5505882 bytes, checksum: 3e253365a0c28b99c3572781dd0849cd (MD5) Previous issue date: 2013-05-29 / Chesf (Companhia Hidroelétrica do São Francisco); CNPq / A incidência direta ou indireta de descargas atmosférica nas linhas de transmissão e distribuição é um dos grandes problemas que afetam a qualidade do serviço de energia elétrica, gerando danos às linhas de transmissão e distribuição e multas para as companhias elétricas. O evento geralmente causa desligamentos não programados, e a determinação do local na linha de transmissão onde ocorreu tal desligamento não possui atualmente uma precisão satisfatória. Outro problema recorrente são os furtos dos cabos para-raios, que deixam as linhas de transmissão desprotegidas e causam prejuízos financeiros para as companhias. A localização dos pontos onde ocorreram as descargas ou furtos dos cabos é necessária para que as equipes de manutenção possam realizar um serviço mais eficiente e preciso. Esta Dissertação apresenta a concepção, construção e testes de dois sistemas que podem ser implantados nas linhas de transmissão de energia elétrica: um para detecção e localização de descargas atmosféricas, que utiliza sensor de corrente elétrica, circuitos eletrônicos e módulos de comunicação; e outro para detecção e localização de furtos de cabos para-raios, pelo uso de antenas de alta diretividade e módulos de comunicação, cuja metodologia faz uso do espalhamento das ondas eletromagnéticas pelos próprios cabos.
142

Projeto de uma rede de alimentação de baixas perdas para um arranjo de antenas utilizando linhas de fita / Design of a power system for a low-loss antena array using striplines

Duplat, Daniel Nascimento 17 August 2018 (has links)
Orientador: Hugo Enrique Hernández Figueroa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-17T09:35:55Z (GMT). No. of bitstreams: 1 Duplat_DanielNascimento_M.pdf: 6130170 bytes, checksum: a8ec6733cbf973341a611dbeb5f31f55 (MD5) Previous issue date: 2010 / Resumo: Este trabalho trata do desenvolvimento teórico e computacional de um arranjo de antenas de grande comprimento elétrico com grande aplicabilidade em radares e sistemas de sensoriamento que utilizam distribuições de potência específicas. São abordados a síntese do padrão de radiação do arranjo, a escolha do número de antenas e o desenvolvimento da rede de alimentação do sistema. De maneira geral, o projeto pode ser dividido em duas partes: cálculo dos parâmetros do arranjo de antenas e desenvolvimento do sistema de alimentação do arranjo. Na primeira parte, a partir da escolha de um diagrama de radiação específico, determina-se o número de antenas e a amplitude e fase de campo eletromagnético que cada antena do arranjo deve receber a fim de gerar o diagrama de radiação necessário. Para tal, adota-se uma distribuição de amplitudes do tipo Hamming adaptada às especificações do projeto e uma distribuição de fase uniforme. Na segunda parte, desenvolve-se um sistema de alimentação para o arranjo de antenas que possibilita a distribuição da energia obedecendo à distribuição de amplitude e fase do campo determinada na fase anterior. O sistema proposto utiliza tecnologia de linhas de fita montada num substrato de poliestireno expandido, que agrega não somente baixas perdas ao sistema de distribuição, mas também baixos custo e peso. É possível verificar, portanto, que o desenvolvimento de um arranjo de antenas com comprimento elétrico muito maior do que o comprimento de onda de operação é um projeto que agrega conhecimentos não somente de antenas e suas características, mas também o conhecimento de arranjos de antenas e ponderação de amplitudes, bem como seus efeitos no diagrama de radiação do arranjo. Contudo, o desenvolvimento deste sistema implica na utilização de sistemas de guiamento eletromagnético que possibilitem a transmissão de energia agregando baixo custo, baixas perdas, e alta eficiência. / Abstract: This work deals with theoretical and computational development of an antenna array of large electrical length with wide application in radar and sensing systems using specific power distribution. The project describes the process from the synthesis of radiation pattern, the choice of the number of antennas and the development of the power supply system. Overall, the project can be divided into two parts: calculation of parameters of the antenna array and development of the power system. In the first part, the number of antennas and the amplitude and phase of the electromagnetic field that each antenna needs are calculated to generate the required radiation pattern. To this end, we adopt a distribution of amplitudes of Hamming type (Hamming weighting) adapted to the project specifications and a uniform phase distribution. In the second part, the power system to the antenna array is developed. This supply system enables the distribution of energy obeying the distribution of amplitude and phase of the field specified in the previous part. The proposed system uses striplines mounted on a substrate of expanded polystyrene, which combines low-losses, low-cost and lightweight. / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
143

Análise dos parâmetros elétricos e transitórios eletromagnéticos de linhas de transmissão compostas por torres com altura elevada / Analysis of the electrical parameters and electromagnetic transients of transmission lines consisting of towers with high height

Pinto, André Jinno Gomes, 1983- 04 July 2011 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T03:00:37Z (GMT). No. of bitstreams: 1 Pinto_AndreJinnoGomes_M.pdf: 60896723 bytes, checksum: 8ce23cc18a981b5042b135acfc03ec42 (MD5) Previous issue date: 2011 / Resumo: As redes de transmissão de energia elétrica estão entre as grandes contribuições que a engenharia ofereceu à civilização moderna. Se tornando aparentes, pelas expressivas linhas de transmissão de alta tensão apoiadas sobre elevadas torres de aço que cruzam o território nacional em todas as direções. No corrente trabalho tem-se por objetivo tratar das alternativas não-convencionais de transmissão de energia elétrica. Comparando o desempenho dessas novas estruturas com o comportamento das estruturas atualmente utilizadas no sistema de transmissão convencional. Para tal são descritos alguns dados da atual configuração do sistema de transmissão nacional. Ademais, breves descrições técnicas serão apresentadas sobre os principais componentes de linhas de transmissão convencionais, tais como: condutores múltiplos, isoladores e anéis anticorona. Tais definições serão introduzidas com o âmbito de proporcionar uma maior familiaridade com o tema em estudo. Uma análise minuciosa é traçada no cálculo dos parâmetros elétricos na frequência, seguido de um estudo dos transitórios eletromagnéticos no domínio do tempo. Causados por sinais de tensão aplicados a entrada das linhas de transmissão / Abstract: The transmission of electric energy is among the great contributions that engineering offered to modern civilization. Becoming apparent, by the expressive lines of high voltage transmission supported on large steel towers that crisscross the country in all directions. In the current work has been aimed at dealing with alternative non-conventional electric power transmission. Comparing the performance of these new structures with the behavior of the structures currently used in conventional transmission system. For such thing are described some of the current configuration of the national transmission system. In addition, brief technical descriptions are presented on the main components of conventional transmission lines, such as multiple conductors, insulators and anti-corona rings. Such definitions will be introduced to the scope of providing a greater familiarity with the subject under study. A detailed analysis is plotted on the calculation of electrical parameters on frequency, followed by a study of electromagnetic transient time domain. Caused by voltage signals applied to the input of the transmission lines / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
144

Modelagem de maquinas de solda por indução eletromagnetica em RF / Modeling of welding machines for electromagnetic induction in RF

Jeronimo, Joice Luiz 13 August 2018 (has links)
Orientador: Hugo Enrique Hernandez Figueroa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T12:10:33Z (GMT). No. of bitstreams: 1 Jeronimo_JoiceLuiz_M.pdf: 4749050 bytes, checksum: f44d530638f8a8121e171afc306321ff (MD5) Previous issue date: 2009 / Resumo: Este trabalho trata do estudo de máquinas industriais de solda por indução eletromagnética na faixa de Rádio Freqüência (RF), visando modelos robustos baseados em circuitos de parâmetros concentrados. Tipicamente as máquinas industriais para a aplicação em questão, apresentam três estágios; a fonte (geração de energia eletromagnética), blindagem e filtragem (através de uma cavidade), e alimentação da carga. Por se tratar de um equipamento de alta potência (dezenas de KVs), a fonte consiste num oscilador à válvula, na faixa 20-50 MHz. A fonte excita uma cavidade que ressoa e funciona como um armazenador dessa radiação eletromagnética e um filtro de freqüência. Finalmente a energia da cavidade é extraída através de dispositivo análogo a uma linha de transmissão e colocado em contato com a carga, isto é, o material a ser soldado. Os modelos propostos fazem uso de circuitos equivalentes eficientes obtidos para as válvulas e as cavidades eletromagnéticas utilizadas, e foram validados através de testes experimentais minuciosos aplicados a uma máquina de fabricação nacional, líder de vendas no mercado latino-americano. / Abstract: This work is related to the study of electromagnetic weld industrial machines operating in radio frequency band aiming robust models based on concentrated parameters circuits. Typically, those machines have three steps: the power source (electromagnetic energy generation), shielding and filtering (through cavity) and load power supply. Since the equipment demands high power (dozen of KVs), the power source consists of a valve oscillator of 20-50MHz bandwidth. The power source excites a cavity that resonants and works like a storing of electromagnetic radiation and a frequency filter. Finally, the cavity energy is extracted through a device that works like a transmission line and sent to the load, that means, the material to be welded. The proposed models use efficient equivalent circuits found for the machine valves and cavities, and they were validated through detailed experiments on a machine produced for a Brazilian company, leader of the Latin American market. / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
145

ESTUDO TEÓRICO E COMPUTACIONAL DO DESEMPENHO DE LINHAS DE TRANSMISSÃO DE ALTA-TENSÃO NA PRESENÇA DE DESCARGAS ATMOSFÉRICAS / THEORY AND COMPUTATIONAL STUDY OF THE PERFORMANCE OF TRANSMISSION LINES FOR HIGH-VOLTAGE DISCHARGES IN THE PRESENCE OF AIR

Pinheiro, Fernando Henrique Costa 17 October 2008 (has links)
Made available in DSpace on 2016-08-17T14:53:01Z (GMT). No. of bitstreams: 1 Fernando Henrique Costa Pinheiro.pdf: 2854886 bytes, checksum: a56fe59d5aabb7763901adeb614ad703 (MD5) Previous issue date: 2008-10-17 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work depicts transmission line modeling for lightning strike time domain simulation. It is studied and presented the main mechanisms associated to lightning formation and striking high-voltage transmission lines and wave propagation theory concerned to the hit point. Following, it is presented and analyzed transmission lines, shield wires and tower models available in the used ATPDraw computer program. Finally, a complete model is constructed taking into account a real utility transmission branch (ELETRONORTE-Ma), including transmission lines, respective towers and shield wires, through computational models available in the ATPDraw computer program. Computer simulations are carried out and the final model is tested for different scenarios: a standard lightning striking a transmission tower; a standard lightning striking a transmission tower with lower tower foot resistance; lightning striking transmission tower for different soil conditions (dry and humid); insulation strength analysis taking into account different hit points (middle of a shield wire and at the top of a transmission tower). The results show that the model behaved as expected. / Este trabalho aborda a modelagem de linhas de transmissão para análises e simulações no domínio do tempo de transitórios eletromagnéticos resultantes de descargas atmosféricas incidentes. É estudado e apresentado os principais mecanismos associados à formação das descargas atmosféricas, os aspectos relevantes à incidência de descargas em linhas de transmissão e os seus mecanismos de propagação em relação ao ponto de incidência. Em seguida é apresentado e analisado modelos de linhas de transmissão, cabos pára-raios e de torres disponíveis para uso no programa computacional ATPDraw. Por fim, é elaborado um modelo de um trecho real da ELETRONORTE MA incluindo linha de transmissão, suas torres e seus cabos pára-raios, através de modelos disponíveis na versão usada do programa ATPDraw. São realizadas simulações computacionais, onde o modelo é testado para vários cenários: surto atmosférico na forma de onda padrão incidindo sobre uma torre; surto atmosférico na forma de onda padrão incidindo sobre uma torre com resistência de dispersão reduzida; surtos atmosféricos incidentes sobre torres nos cenários de solos secos e úmidos; e impactos nos isolamentos no meio do vão e em uma torre de um surto atmosférico incidente nos cabos pára-raios. Para todos os testes realizados, a resposta do modelo esteve de acordo com o comportamento esperado.
146

Controle adaptativo para religamento tripolar aplicado a linhas de transmissão com compensação reativa em derivação / Adaptive control for three phase reclosing applied to shunt reactor compensated transmission lines

Mestas Valero, Patricia 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T10:56:05Z (GMT). No. of bitstreams: 1 MestasValero_Patricia_D.pdf: 4018272 bytes, checksum: 38a65b52b68046f67c3791c9b6ea2f7d (MD5) Previous issue date: 2011 / Resumo: O presente trabalho descreve um novo método de controle adaptativo para chaveamento sincronizado de disjuntores durante a manobra de religamento tripolar de linhas de transmissão com compensação reativa em derivação. O objetivo principal do método desenvolvido é controlar as sobretensões transitórias e reduzir o tempo morto antes do religamento. Diferentes estratégias para controlar sobretensões decorrentes do religamento tripolar são descritas com a finalidade de diferenciar as vantagens do chaveamento sincronizado. Os benefícios potenciais a serem obtidos a partir do religamento tripolar rápido são expostos. O método de controle adaptativo desenvolvido consiste em identificar com antecedência a região ótima para o religamento, permitindo fechar o disjuntor já no primeiro mínimo do batimento da tensão entre os contatos do disjuntor após o tempo morto de atuação da proteção. Após os testes realizados utilizando um programa para simulação de transitórios eletromagnéticos (PSCAD/EMTDC), o método proposto foi implementado em protótipo (controlador). Este protótipo foi testado utilizando o Simulador Digital em Tempo Real (RTDS). As simulações em tempo real demonstraram a eficiência do método no controle das sobretensões e na redução do tempo morto. Finalmente, o método foi avaliado parametricamente para uma série de condições simuladas, incluindo diferentes níveis de compensação reativa em derivação, a influência da compensação série, a influência da transposição da linha de transmissão e os efeitos da variação do comprimento da linha. Além disto, outras simulações foram realizadas para comparar o desempenho dos métodos de controle existentes e do método proposto / Abstract: The present thesis describes a new adaptive control method for synchronous switching of circuit breakers during three-phase reclosing of shunt compensated transmission lines. The main objective of the developed method is to control the overvoltages and to reduce the dead time prior of reclosing. Several strategies to control overvoltages resulting from three-phase reclosing are described in order to differentiate the benefits of the proposed method. The potential benefits obtained from the developed controlled reclosing method are exposed. The proposed algorithm identified, in advance, the optimal region for reclosing of transmission line, allowing closing the circuit breaker at the first minimum voltage beat across circuit breaker, after protection dead time. After off-line testing using electromagnetic transients simulation program (PSCAD/EMTDC), the proposed method was also implemented in physical hardware. This hardware was then tested on a real-time transients simulator (RTDS). The real time simulations demonstrate the method efficiency to control overvoltages and to reduce the dead time. Finally, the method has been parametrically evaluated for a range of simulated conditions, including different shunt compensation levels, influence of series compensation, influence of transmission line transposition, effect of line lengths. In addition, simulations have been conducted to compare the performance of existing control method and the proposed method / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
147

Estudo da conexão da usina de Belo Monte ao SIN através da alternativa de transmissão em meia onda / Half wavelegth transmission lines connecting Belo Monte power plant to the Brazilian interconnected system

Gomes, Leandro Costa Ferreira, 1986- 24 August 2018 (has links)
Orientador: Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T07:39:20Z (GMT). No. of bitstreams: 1 Gomes_LeandroCostaFerreira_M.pdf: 6148500 bytes, checksum: bf5007e253bf40d848b0494ce01ead56 (MD5) Previous issue date: 2014 / Resumo: O presente trabalho está inserido num contexto de busca de novas fontes de energia elétrica e de aproveitamento de grandes potenciais energéticos localizados distantes dos principais centros de carga. Para estes, alternativas não convencionais de transmissão também são exigidas, nas quais se insere a transmissão em linhas de pouco mais de meio comprimento de onda, distância de pouco mais de 2500km no sistema brasileiro à 60Hz. Como este tipo de transmissão nunca foi implementado, trata-se de uma proposta inovadora, pouco explorada e que exige ensaios elementares para testar-se a viabilidade, vantagens e desvantagens frente a outras alternativas de transmissão de energia elétrica. Esta dissertação visa investigar alguns aspectos referentes à tal método de transmissão de grandes montantes de potência em distintos cenários de interligação entre as regiões Norte e Sudeste do Brasil do SIN (sistema interligado nacional). Três distintos corredores compostos por linhas de pouco mais de meio comprimento de onda foram ensaiados. Inseridos conectando a usina de Belo Monte no Pará a Assis-SP na rede de 500kV, percorrendo 2664 km. Cada um dos corredores é composto por: três linhas de 800 kV e 4846 MW de potência característica (SIL); um segundo com duas das mesmas linhas de 800kV e um terceiro com duas linhas de 1000 kV e 8100 MW de potência característica. Cada aspecto é ensaiado em seis diferentes situações de carregamento do SIN e de fluxo de potência pelo corredor, abrangendo cenários de alto, médio e baixo carregamento das linhas assim como mudanças no sentido do fluxo entre Norte e Sudeste. Dentre os aspectos abordados estão: a avaliação e redução das perdas manipulando a potência característica operacional das linhas; o controle do carregamento do corredor através do uso de transformadores defasadores não convencionais; a inserção de cargas e geração em pontos intermediários deste e o controle do fluxo de potência reativa. Por fim, o estudo não aborda aspectos transitórios e é realizado com o auxílio do ANAREDE, software elaborado pelo CEPEL / Abstract: This work is placed in a search for new sources of power and exploitation of large energy potential located far from major load centers. For the second scenarios, alternate non-conventional transmission are also required, in which half wavelength transmission lines are inserted, resulting in a distance of just over 2500km for the 60Hz brazilian electrical system. Since this type of transmission has never been implemented, it is an innovative solution and few explored, requiring elementary studies to test the feasibility, advantages and disadvantages compared to other alternatives for bulk electric power transmission. This thesis aims to investigate some aspects related to such transmission method for large amounts of power into distinct scenarios of interconnection between the North and Southeast of Brazil's SIN (Brazilian National grid). Corridors consisting of three distinct lines of just over half wavelength were tested. Inserted connecting Belo Monte hydro power plant in Para to Assis in São Paulo through the 500kV network, covering 2664 km, each corridor is composed: by three lines of 800 kV and 4846 MW of Surge Load Impedance (SIL), the second one by two of the same 800kV lines and a third by two lines of 1000 kV and 8100 MW SIL. Each aspect is tested in six different SIN load situations and power flowing through the corridor, covering scenarios of high, medium and low lines loading as well as changes in flow direction between North and Southeast. Among the issues tackled are: evaluation and reduction of losses by manipulating operating lines SIL; line load controlling using non-conventional phase shift transformers; inserting loads and generation at intermediate points of the lines and control of reactive power flow. Finally, the study does not handle with transient aspects and is accomplished with the aid of ANAREDE, software developed by CEPEL / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
148

Modelagem de torres de transmissão utilizando análise numérica dos campos eletromagnéticos e funções racionais / Transmission towers modeling using numerical analysis of electromagnetic fields and rational functions

Pinto, André Jinno Gomes, 1983- 24 August 2018 (has links)
Orientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T10:02:40Z (GMT). No. of bitstreams: 1 Pinto_AndreJinnoGomes_D.pdf: 9708757 bytes, checksum: 84772389fed6b8c0c68adcdd4db7cd9b (MD5) Previous issue date: 2014 / Resumo: A análise do comportamento dinâmico da torre de transmissão de energia elétrica e torres de telecomunicações é de interesse nos estudos de proteção relacionados com descargas atmosféricas. Normalmente, a impedância de surto da torre no domínio do tempo é usada para caracterizar o comportamento dinâmico da torre. A principal desvantagem na definição de tais impedâncias de surto é a dependência da forma de onda de excitação, e não há consenso sobre a forma de onda de corrente a ser usada. Além disso, não há concordância sobre uma definição única da tensão envolvida. A fim de contornar tais limitações e problemas, o modelo aplicado ao estudo faz uso das análises no dominio da frequência, onde a impedância de surto da torre depende somente da geometria da estrutura e das características eletromagnéticas do meio. Ademais, as limitações associadas com as abordagens simplificadas são enfatizadas no decorrer do presente trabalho. Os resultados apresentados fazem uso de ferramentas computacionais como o código NEC-2 (Numerical Electromagnetic Code) que se baseia na análise numérica da dinâmica do campo eletromagnético. Com a utilização desse código, correntes são geradas e posteriormente utilizadas para o cálculo da impedância de surto da torre. Posteriormente, é gerado um circuito RLC representativo das características da estrutura metálica, obtidas pelo método de vector fitting que aproxima a função impedância de surto da torre por funções racionais. Por fim, o circuito RLC gerado pode ser aplicado nas análises diretamente no domínio do tempo com o uso de programas computacionais como o EMTP (Electromagnetic Transients Program), sem a necessidade do uso de transformadas para alterar o domínio de análise / Abstract: The dynamic analysis of the behavior in power transmission towers and telecommunications towers is of interest in studies related to lightning protection. Normally, the surge impedance of the tower in the time domain is used to characterize the dynamic behavior of the tower. The main disadvantage of these definition of surge impedances is the dependence on the waveform of excitation, and there is no consensus on which current wave to be used. Furthermore, there is no agreement on a single definition of the voltage involved. In order to overcome such limitations and problems, the model applied to the study makes use of the analysis in the frequency domain, where tower¿s surge impedance depends only on the geometry of the structure and electromagnetic characteristics of the medium. Moreover, the limitations associated with the simplified approaches are emphasized in the course of this work. The results presented make the use of computer code as NEC-2 (Numerical Electromagnetic Code) based on the numerical analysis of the electromagnetic field dynamics. Using this code, currents are generated and then used to calculate the surge impedance of the tower. Subsequently, an RLC circuit is generated representating the characteristics of the metal structure, obtained by vector fitting method, that approximates the surge impedance function of the tower by means of rational functions. Finally, the generated RLC circuit can be applied directly in analyzes in the time domain using computer programs such as EMTP (Electromagnetic Transients Program) without the need of using transforms to change domain analysis / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
149

Maximização de limites de carregamento e padronização de subestações e linhas de transmissão: um suporte ao planejamento de redes elétricas em ambiente de restrições financeiras. / Equipment rating maximization and standardization of substations and transmission lines: a support for the planning of electrical networks in the context of financial constraints.

Dorel Soares Ramos 10 April 1996 (has links)
Este trabalho tem por meta focalizar a adaptação necessária na metodologia de planejamento atual, norteada segundo uma ótica determinística e conservadora, afim de permitir a elaboração de Programas de Obras de Transmissão/Subtransmissão, condicionados por limitações de teto no montante de investimento a curto e médio prazos. Para tanto, como tema central, busca-se desenvolver uma base conceitual e metodológica, para permitir uma exploração maximizada das possibilidades de carregamento de equipamentos e instalações do sistema de transmissão, contemplando a especificação das ferramentas computacionais necessárias para dar consequência prática à proposta. Considerando o potencial de análise proporcionado por métodos e técnicas de natureza probabilística, aplicados ao planejamento de Sistemas Elétricos, a espinha dorsal da evolução metodológica delineada no texto repousa sobre a avaliação de confiabilidade global e quantificação de riscos operativos. O texto foi estruturado em 8 capítulos onde, a partir de um capítulo introdutório, enfoca-se sequencialmente os temas: * Conceitos e Metodologias para Maximização do Carregamento de Transformadores de Potência. * Conceitos e Metodologias para Maximização do Carregamento de Linhas aéreas de Transmissão. * Impacto das Restrições Financeiras no planejamento e possibilidade de atuação a nível técnico para administrar o conflito entre qualidade de serviço e recursos limitados. * Conceitos e Metodologias para relaxação dos Critérios limitantes para o carregamento máximo de componentes do sistema, em ambiente de severas restrições financeiras, no horizonte de curto prazo. * Resultados obtidos em aplicações concretas a situações do Setor Elétrico, visando caracterizar o alcance do ferramental preconizado nos capítulos anteriores. * Critérios e Procedimentos para Padronização de Subestações e Linhas de Transmissão , coerentes com os conceitos de maximização de carregamento introduzidos nos dois primeiros capítulos. Ao final do texto, incluiu-se um capítulo de \"Conclusões\", com o objetivo de sumarizar os aspectos mais relevantes abordados no texto, assim como indicar linhas de ação e novos desenvolvimentos, necessários para permitir a efetivação prática da metodologia proposta. / An important problem posed to power system planners in developing countries is now becoming commonplace, even in developed countries, and concerns on how to fit an expansion plan into a tight budget, with the least reduction in reliability levels. This problem is known as power system planning under financial constraints and a series of methods is now available to deal with it. So, this work addresses the necessary adjustments in order to permit the Transmission / Sub-transmission Expansion Program establishment when there are investments constraints in a medium/short term range. The main emphasis is on the development of a methodological and conceptual framework, aiming at a maximizes exploration of the loading capability of transformers and transmission lines of the power network. In this context, a new methodological framework for transmission system planning in a financial constrained environment is presented. The proposed approach combines transmission projects priority evaluation and ranking as well as criteria flexibilization, being particularly suitable for short-term planning. The problem to be faced is to operate the system after a project postponement, while the service quality is kept so adequate as it is possible. One of the main issues to be focused is the transmission system uprating since a maximized equipment utilization can contribute to avoid a more significant restriction to the costumers. Therefore, a detailed description of the models for transmission lines and transformers loading limits assessment is presented, with emphasis on the main concepts and the application of probabilistic tools to circumvent the inherent conservatism of deterministic methods. A summary of the contents is presented in what follows: * Concepts and Methodology for Transformers loading maximization. * Concepts and Methodology for Transmission Lines loading maximization. * Financial Restrictions impacts on Expansion Planning Process and the possibilities to manager the conflict between service quality and investment constraints. * Concepts and Methodologies to the relaxation of Criteria that limits the loading capability of transmission lines, aiming at short term Planning under severe financial restrictions, * Obtained results in concrete applications of the proposed methodology and computational tools to Brazilian Electric Power System. * Methods and Criteria to standardization of Substations and Transmission Lines, according the main issues formerly introduced. * Conclusion and Future Research.
150

Análise da eficiência de um método alternativo de integração das equações diferenciais ordinárias de linhas de transmissão /

Fernandes, João Paulo January 2020 (has links)
Orientador: Sérgio Kurokawa / Resumo: Uma linha de transmissão representada por uma cascata de circuitos π é descrita por meio de sistema de equações diferenciais ordinárias que podem ser resolvidas diretamente no domínio do tempo, através de métodos numéricos de integração. A cada passo de cálculo é resolvido o sistema de ordem 2n, sendo n a quantidade de circuitos π. Este é o procedimento clássico de resolução. Um método alternativo de resolução de equações diferencias, proposto recentemente, resolve os sistemas de equações diferenciais em linhas de até 5 km representada por uma quantidade limite de 333 circuitos π. Neste trabalho é investigado a aplicação desse método alternativo em linhas de maior comprimento e sua eficiência na resolução das equações diferenciais que representam a linha de transmissão. No método alternativo cada circuito π da linha é resolvido individualmente através de um sistema que não depende da quantidade de circuitos π, cuja matrizes possuem ordem 2x2. Dessa forma, para n circuitos π é necessário resolver n sistemas de duas equações diferencias para cada instante de tempo. Este procedimento é denominado como método acelerado. A análise do desempenho do método acelerado é realizada através do número de operações de pontos flutuantes (flops) e através do tempo de cálculo das variáveis de estado ao longo da linha de transmissão. O mesmo procedimento é realizado no método clássico e após comparados os resultados é possível constatar a eficiência do método acelerado para determinadas config... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A transmission line represented by a cascade of π circuits is described by means of a system of ordinary differential equations that can be solved directly in the time domain, through numerical integration methods. At each calculation step, the 2n order system is solved, with n being the number of π circuits. This is the classic resolution procedure. An alternative method of solving differential equations recently proposed solves the systems of differential equations in lines of up to 5 km represented by a limit quantity of 333 π circuits. This work investigates the application of this alternative method on lines of greater length and its efficiency in solving the differential equations that represent the transmission line. In the alternative method, each π circuit of the line is solved individually through a system that does not depend on the number of π circuits, whose matrices have a 2x2 order. Thus, for n π circuits, it is necessary to solve n systems of two different equations for each instant of time. This procedure is called an accelerated method. The analysis of the performance of the accelerated method is performed through the number of floating-point operations (flops) and through the calculation time of the state variables along the transmission line. The same procedure is performed in the classic method and after comparing the results it is possible to verify the efficiency of the accelerated method for certain transmission line configurations. / Mestre