• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • 1
  • Tagged with
  • 12
  • 12
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The development of capillary electrochromotography (CEC) and its coupling with electrospray mass spectroscopy

Paterson, Clare Jane January 1998 (has links)
No description available.
2

Desenvolvimento de métodos cromatográficos para análises de antimicrobianos em amostras complexas / Development of chromatographic methods for analysis of antimicrobials in complex samples

Melo, Lidervan de Paula 23 April 2012 (has links)
Este trabalho descreve o desenvolvimento de novos métodos cromatográficos em conjunto com técnicas de microextração para determinação de parabenos em produtos cosméticos e leite humano e rifampicina em amostras de plasma. Destaca-se também o desenvolvimento da fase extratora molecularmente impressa para extração em fase sólida (SPE) de parabenos em amostras de leite humano. O capítulo I descreve a avaliação da extração sortiva em barra de agitação (SBSE) em conjunto com a cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de parabenos em produtos cosméticos para fins de controle de qualidade. As variáveis do processo de extração SBSE, tais como tempo e temperatura de extração, pH e força iônica da amostra e condições de dessorção foram otimizadas para aumentar a sensibilidade analítica do método e diminuir o tempo de análise. O método SBSE/LC-UV desenvolvido apresentou faixa linear correspondente ao limite de quantificação (LQ) a 2,50 µg. mg-1 e coeficientes de determinação maiores que 0,993. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 5,0% para todos os parabenos analisados e a exatidão variou de 90 a 100%. O método desenvolvido foi aplicado para análises de amostras de produtos cosméticos comerciais (cremes hidratantes, antitranspirantes em creme e filtros solares). O método SBSE/LC-UV padronizado e validado resultou nas seguintes vantagens em relação aos métodos convencionais: simplicidade no preparo de amostra, redução do volume de solvente orgânico e da quantidade de amostra utilizada. O capítulo II descreve o desenvolvimento da fase extratora molecularmente impressa para SPE de parabenos em amostras de leite humano e análises por cromatografia em fase líquida com detecção espectrofotométrica (SPE/LC-UV). Os polímeros de impressão molecular, materiais sintéticos baseados em sistemas biomiméticos, foram sintetizados através do processo sol-gel tendo como molde, o benzilparabeno. Após a remoção do molde, cavidades seletivas (sítios de reconhecimento molecular) ao benzilparabeno e análogos estruturais foram reveladas. O método SPE/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação a 150 ng. mL-1 e coeficientes de determinação 0,992. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 13% e a exatidão variou de 86 a 117%. A aplicabilidade do método SPE/LC foi demonstrada através das análises de amostras de leite humano de lactantes. Segundo os parâmetros de validação analítica avaliados, o método padronizado SPE/LC-UV é adequado para análises de parabenos em amostras de leite humano. O capítulo III descreve a avaliação da microextraçao em fase sólida no capilar (in-tube SPME) acoplada à cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de rifampicina em amostras de plasma para fins de monitorização terapêutica. As variáveis in-tube SPME, tais como fase estacionária da coluna capilar, volume de amostra, ciclos aspirar/dispensar e vazão foram otimizadas visando obter maior eficiência do processo. O método in-tube SPME/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação (0,1 µg. mL-1) a 100 µg. mL-1 e coeficientes de determinação igual a 0,998. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 2% e a exatidão variou de 83 a 92%. A aplicabilidade do método in-tube SPME/LC, padronizado e validado foi comprovada através das análises de amostras de plasma de pacientes em tratamento com rifampicina. O método in-tube SPME/LC resultou na automação do processo de análise, maior precisão analítica, menor tempo de análise, menor volume de solvente orgânico e de fluido biológico. / This work describes the development of chromatographic methods in combination with microextraction techniques for the determination of parabens in cosmetic and human milk samples and of rifampicin in plasma samples. The design of a molecularly imprinted extraction phase for the solid-phase extraction (SPE) analysis of parabens in human milk samples is also reported. Chapter I describes the evaluation of the stir bar sorptive extraction (SBSE) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of parabens in cosmetics aiming at quality control. The SBSE variables such as extraction time, temperature, pH of the matrix, ionic strength, and desorption conditions have been optimized, in order to establish the parabens partition equilibrium in a short analysis time. The linear range of the SBSE/LC method lay from LOQ to 2.5 µg. mg-1, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%, and the accuracy ranged from 90 to 99%. The effectiveness of the proposed method for the analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens has been proven. Therefore, the combination of SBSE with liquid desorption, followed by LC analysis, provides a simple, and selective tool for the analysis of parabens in cosmetic products using minimized volume of organic solvent as well as very small amount of the target sample. Chapter II presents the development of a molecularly imprinted extraction phase for the SPE analysis of parabens in human milk samples. The molecularly imprinted polymers, which are synthetic materials based on biomimetic systems, were synthesized by the sol-gel technology in the presence of the template (benzilparaben). After template removal, selective cavities (benzilparaben) were revealed for parabens selective extraction. The linear range of the SPE/LC method lay from LOQ to 150 ng. mL-1, with a coefficient of determination higher than 0.992. The interday precision of the SPE/LC method presented a coefficient of variation lower than 13%, and the accuracy ranged from 86 to 117%. The effectiveness of the proposed method for the analysis of human milk samples has been demonstrated. According to the evaluated analytical validation parameters, the SPE/LC-UV method is suitable for the analysis of parabens in human milk samples. Chapter III depicts the evaluation of solid-phase microextraction in the capillary (in-tube SPME) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of rifampicin in plasma samples for therapeutic drug monitoring. The in-tube SPME/LC method was linear over the LOQ (0.1) to 100 g. mL-1 range, with a linear coefficient value (r2) of 0.998. The inter-assay precision presented coefficient of variation 2%, and the accuracy ranged from 83 to 92%. The effectiveness and practicability of the proposed method have been by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. The in-tube SPME/LC method allowed for automated continuous sample preparation (extraction, concentration, desorption, and injection of analytes) and minimized the analysis time as well as the volumes of organic solvent and biological fluid.
3

Desenvolvimento de método para determinação de acetaldeído em álcool etílico hidratado combustível por cromatografia líquida de alta eficiência com detecção eletroquímica /

Okumura, Leonardo Luiz January 2003 (has links)
Orientador: Nelson Ramos Stradiotto / Resumo: O comportamento cíclico voltamétrico do acetaldeído e seu derivado foi estudado em eletrodo de gota pendente de mercúrio e carbono vítreo. Este estudo foi utilizado na otimização das condições para a detecção eletroquímica desses compostos por Cromatografia Líquida de Alta Eficiência (C.L.A.E.). O acetaldeído foi derivado com 2,4-dinitrofenilhidrazina (DNPHi) e o produto, a 2,4-dinitrofenilhidrazona do acetaldeído (AcH-DNPHo) foi eluida e separada por coluna de fase reversa C18 em condições isocráticas com fase móvel contendo uma mistura binária de metanol-solução aquosa de cloreto de lítio (LiCl) com concentração de 1,0 ' 10-3 M (80:20% v/v) e vazão de 1,0 mL min-1. A detecção eletroquímica (D.E.) do AcH-DNPHo foi realizada por C.L.A.E. com potencial fixado em + 1,0 V vs eletrodo de referência Ag/AgCl. O método proposto foi simples, rápido (tempo de análise 7 min.), com limite de detecção 3,80 mg L-1, altamente seletivo, e reprodutível [desvio padrão relativo 8,2% (n=12)]. A curva analítica do AcH-DNPHo foi linear na faixa compreendida de 0 - 300 mg L-1, com índice de correlação linear 0,9998. A concentração de acetaldeído determinada em amostras de álcool combustível foi de 83 - 341 mg L-1 com desvio padrão de 1 - 6 %, na variação da área de pico e recuperação superior a 99%. A quantidade do teor de acetaldeído encontrado nestas amostras foi significativamente alta e os resultados obtidos foram comparados com o método de detecção espectrofotométrica (UV/Vis) / Abstract: The cyclic voltammetric behaviour of acetaldehyde and their derivatives has been studied at a hanging drop mercury and glassy carbon electrode. This study was used to optimise the conditions for the electrochemical detection of these compounds following high-performance liquid chromatographic (H.P.L.C.) separation. The acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPHi) and the product 2,4-dinitrophenylhydrazone (AcH-DNPHo) was eluted and separated by reversed-phase column C18 in isocratic conditions with mobile phase containing binary mixture of methanol-chloride littium aqueous solution with concentration 1,0 ' 10-3 M (80:20% v/v) and flow rate of 1.0 mL min-1. The electrochemical detection (E.D.) of AcH-DNPHo was performed by H.P.L.C. set at +1.0 V vs Ag/AgCl as reference electrode. The proposed method was simple, rapid (analysis time 7 min), with detection limit 3.80 mg L-1, highly selective, and reproducible [relative standard deviation 8.2 % (n=12)]. The calibration graph for AcH-DNPHo was linear in the range of 0 - 300 mg L-1 with correlation coefficient 0,9998. The concentrations of acetaldehyde determined in fuel alcohol samples was in the range of 83 - 341 mg L-1 with standard deviation of 1 - 6 %, in peak area variation and analytical recovery was >99%. The amount of acetaldehyde content found in these samples was significantly higher and the results obtained were compared to the spectrofotometric detection method (UV/Vis) / Mestre
4

Dispersive liquid-liquid microextraction for the determination of metals / Dispersinė skystafazė mikroekstrakcija metalams nustatyti

Razmislevičienė, Ina 25 June 2013 (has links)
The aim of this work was to investigate and apply new DLLME systems coupled with LA-ICP-MS and ultra-performance liquid chromatography (UPLC) techniques for the preconcentration and determination of Cr(VI), Co(II), Cu(II) ir Ni(II) ions. / Šioje daktaro disertacijoje apibendrintų mokslinių tyrimų tikslas – ištirti ir pritaikyti naujus Cr(VI), Co(II), Cu(II) ir Ni(II) koncentravimo ir nustatymo metodus apjungiant dispersinę skystafazę mikroekstrakciją (DSME) su lazerinio išgarinimo induktyviai sužadintos plazmos masių spektrometrijos (LA-ICP-MS) bei ultraefektyviosios skysčių chromatografijos (UESCh) metodais.
5

Herbicidas mais empregados no cultivo de cana-de-açúcar no município de Araraquara (SP): desenvolvimento e validação de método de quantificação e avaliação do potencial de lixiviação em solos argiloso e arenoso (área de recarga do Sistema Aquífero Guarani)

Lourencetti, Carolina [UNESP] 31 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-31Bitstream added on 2014-06-13T18:46:08Z : No. of bitstreams: 1 lourencetti_c_dr_araiq.pdf: 1138552 bytes, checksum: 5d745386dcdebc6d1b132add7225c1a7 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O potencial de contaminação das águas subterrâneas por pesticidas pode ser avaliado empregando estimativas direta, determinação do comportamento dos pesticidas em solo, e indireta, uso de modelos de previsão do potencial de lixiviação dos mesmos. Considerando-se o aumento do uso das águas subterrâneas para abastecimento urbano, rural e industrial e a possibilidade de contaminação das mesmas por pesticidas utilizados em plantações localizadas em áreas de elevada vulnerabilidade natural à poluição, este estudo teve como objetivo geral avaliar o potencial de lixiviação de três herbicidas largamente empregados no cultivo da cana-de-açúcar, comparando resultados obtidos com o uso dos valores das propriedades (Koc, tu) determinadas em laboratório e disponíveis na literatura. A influência da adição de vinhaça de cana-de-açúcar ao solo foi investigada por ser uma prática comum nessa cultura. O trabalho foi realizado em quatro etapas: seleção dos princípios ativos, desenvolvimento e validação do método, determinação das propriedades dos herbicidas (tu; Kd e Koc) e aplicação de índices que avaliam o potencial de lixiviação (GUS - Groundwater Ubiquity Score e LIX - Leaching IndeX). Os resultados da aplicação dos índices de GUS e LIX, utilizando os parâmetros determinados em laboratório (tu, Koc), estão de acordo com a classificação de potencial de lixiviação prevista quando dados da literatura foram empregados para o cálculo desses índices. Esse fato demonstra que o emprego dos valores das propriedades dos pesticidas, determinados em condições diferentes das de uso, podem ser utilizadas em uma etapa preliminar para indicar quais pesticidas deveriam ser priorizados em estudos mais complexos, como os estudos de monitoramento ambiental. / Potential of groundwater contamination by pesticides can be evaluated using direct, determination of pesticide behavior in soil, and indirect estimates, use of models to predict the potential of pesticides leaching. Taking into account the increase of groundwater use for urban, rural and industrial supply, and the possibility of their contamination by pesticides, used in crops located in high natural vulnerability areas, the general objective of this study was evaluating the leaching potential of herbicides, more intensely used in sugarcane crops, comparing results obtained with properties values (Koc, tu) determined in laboratory and available in the literature. Influence of sugarcane vinasse addition in soil was investigated because this is a common practice in this culture. The work was carried out in four steps: choice of active ingredient, method development and validation, herbicides properties determination (tu; Kd and Koc) and leaching indices application (Groundwater Ubiquity Score-GUS and Leaching IndeXLIX). The results of GUS and LIX indices application, using parameters determined in laboratory (tu, Koc), agree with the leaching potential classification predicted when literature values were employed in these indices calculation. This fact shows that the use of herbicides properties, determined in different conditions of their use, can be utilized in a preliminary step to indicate which pesticides should be prioritized in studies more complex, as environmental monitoring studies.
6

Herbicidas mais empregados no cultivo de cana-de-açúcar no município de Araraquara (SP) : desenvolvimento e validação de método de quantificação e avaliação do potencial de lixiviação em solos argiloso e arenoso (área de recarga do Sistema Aquífero Guarani) /

Lourencetti, Carolina. January 2006 (has links)
Orientador: Maria Lucia Ribeiro / Banca: Alberto José Cavalheiro / Banca: Arquimedes Lavorenti / Banca: Isabel Cristina Sales Fontes Jardim / Banca: Eny Maria Vieira / Resumo: O potencial de contaminação das águas subterrâneas por pesticidas pode ser avaliado empregando estimativas direta, determinação do comportamento dos pesticidas em solo, e indireta, uso de modelos de previsão do potencial de lixiviação dos mesmos. Considerando-se o aumento do uso das águas subterrâneas para abastecimento urbano, rural e industrial e a possibilidade de contaminação das mesmas por pesticidas utilizados em plantações localizadas em áreas de elevada vulnerabilidade natural à poluição, este estudo teve como objetivo geral avaliar o potencial de lixiviação de três herbicidas largamente empregados no cultivo da cana-de-açúcar, comparando resultados obtidos com o uso dos valores das propriedades (Koc, tu) determinadas em laboratório e disponíveis na literatura. A influência da adição de vinhaça de cana-de-açúcar ao solo foi investigada por ser uma prática comum nessa cultura. O trabalho foi realizado em quatro etapas: seleção dos princípios ativos, desenvolvimento e validação do método, determinação das propriedades dos herbicidas (tu; Kd e Koc) e aplicação de índices que avaliam o potencial de lixiviação (GUS - Groundwater Ubiquity Score e LIX - Leaching IndeX). Os resultados da aplicação dos índices de GUS e LIX, utilizando os parâmetros determinados em laboratório (tu, Koc), estão de acordo com a classificação de potencial de lixiviação prevista quando dados da literatura foram empregados para o cálculo desses índices. Esse fato demonstra que o emprego dos valores das propriedades dos pesticidas, determinados em condições diferentes das de uso, podem ser utilizadas em uma etapa preliminar para indicar quais pesticidas deveriam ser priorizados em estudos mais complexos, como os estudos de monitoramento ambiental. / Abstract: Potential of groundwater contamination by pesticides can be evaluated using direct, determination of pesticide behavior in soil, and indirect estimates, use of models to predict the potential of pesticides leaching. Taking into account the increase of groundwater use for urban, rural and industrial supply, and the possibility of their contamination by pesticides, used in crops located in high natural vulnerability areas, the general objective of this study was evaluating the leaching potential of herbicides, more intensely used in sugarcane crops, comparing results obtained with properties values (Koc, tu) determined in laboratory and available in the literature. Influence of sugarcane vinasse addition in soil was investigated because this is a common practice in this culture. The work was carried out in four steps: choice of active ingredient, method development and validation, herbicides properties determination (tu; Kd and Koc) and leaching indices application (Groundwater Ubiquity Score-GUS and Leaching IndeXLIX). The results of GUS and LIX indices application, using parameters determined in laboratory (tu, Koc), agree with the leaching potential classification predicted when literature values were employed in these indices calculation. This fact shows that the use of herbicides properties, determined in different conditions of their use, can be utilized in a preliminary step to indicate which pesticides should be prioritized in studies more complex, as environmental monitoring studies. / Doutor
7

Desenvolvimento de métodos cromatográficos para análises de antimicrobianos em amostras complexas / Development of chromatographic methods for analysis of antimicrobials in complex samples

Lidervan de Paula Melo 23 April 2012 (has links)
Este trabalho descreve o desenvolvimento de novos métodos cromatográficos em conjunto com técnicas de microextração para determinação de parabenos em produtos cosméticos e leite humano e rifampicina em amostras de plasma. Destaca-se também o desenvolvimento da fase extratora molecularmente impressa para extração em fase sólida (SPE) de parabenos em amostras de leite humano. O capítulo I descreve a avaliação da extração sortiva em barra de agitação (SBSE) em conjunto com a cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de parabenos em produtos cosméticos para fins de controle de qualidade. As variáveis do processo de extração SBSE, tais como tempo e temperatura de extração, pH e força iônica da amostra e condições de dessorção foram otimizadas para aumentar a sensibilidade analítica do método e diminuir o tempo de análise. O método SBSE/LC-UV desenvolvido apresentou faixa linear correspondente ao limite de quantificação (LQ) a 2,50 µg. mg-1 e coeficientes de determinação maiores que 0,993. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 5,0% para todos os parabenos analisados e a exatidão variou de 90 a 100%. O método desenvolvido foi aplicado para análises de amostras de produtos cosméticos comerciais (cremes hidratantes, antitranspirantes em creme e filtros solares). O método SBSE/LC-UV padronizado e validado resultou nas seguintes vantagens em relação aos métodos convencionais: simplicidade no preparo de amostra, redução do volume de solvente orgânico e da quantidade de amostra utilizada. O capítulo II descreve o desenvolvimento da fase extratora molecularmente impressa para SPE de parabenos em amostras de leite humano e análises por cromatografia em fase líquida com detecção espectrofotométrica (SPE/LC-UV). Os polímeros de impressão molecular, materiais sintéticos baseados em sistemas biomiméticos, foram sintetizados através do processo sol-gel tendo como molde, o benzilparabeno. Após a remoção do molde, cavidades seletivas (sítios de reconhecimento molecular) ao benzilparabeno e análogos estruturais foram reveladas. O método SPE/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação a 150 ng. mL-1 e coeficientes de determinação 0,992. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 13% e a exatidão variou de 86 a 117%. A aplicabilidade do método SPE/LC foi demonstrada através das análises de amostras de leite humano de lactantes. Segundo os parâmetros de validação analítica avaliados, o método padronizado SPE/LC-UV é adequado para análises de parabenos em amostras de leite humano. O capítulo III descreve a avaliação da microextraçao em fase sólida no capilar (in-tube SPME) acoplada à cromatografia líquida (LC) com detecção espectrofotométrica (LC-UV) para análises de rifampicina em amostras de plasma para fins de monitorização terapêutica. As variáveis in-tube SPME, tais como fase estacionária da coluna capilar, volume de amostra, ciclos aspirar/dispensar e vazão foram otimizadas visando obter maior eficiência do processo. O método in-tube SPME/LC desenvolvido apresentou faixa linear correspondente ao limite de quantificação (0,1 µg. mL-1) a 100 µg. mL-1 e coeficientes de determinação igual a 0,998. Os valores de coeficiente de variação resultantes das análises de precisão interensaios foram 2% e a exatidão variou de 83 a 92%. A aplicabilidade do método in-tube SPME/LC, padronizado e validado foi comprovada através das análises de amostras de plasma de pacientes em tratamento com rifampicina. O método in-tube SPME/LC resultou na automação do processo de análise, maior precisão analítica, menor tempo de análise, menor volume de solvente orgânico e de fluido biológico. / This work describes the development of chromatographic methods in combination with microextraction techniques for the determination of parabens in cosmetic and human milk samples and of rifampicin in plasma samples. The design of a molecularly imprinted extraction phase for the solid-phase extraction (SPE) analysis of parabens in human milk samples is also reported. Chapter I describes the evaluation of the stir bar sorptive extraction (SBSE) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of parabens in cosmetics aiming at quality control. The SBSE variables such as extraction time, temperature, pH of the matrix, ionic strength, and desorption conditions have been optimized, in order to establish the parabens partition equilibrium in a short analysis time. The linear range of the SBSE/LC method lay from LOQ to 2.5 µg. mg-1, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%, and the accuracy ranged from 90 to 99%. The effectiveness of the proposed method for the analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens has been proven. Therefore, the combination of SBSE with liquid desorption, followed by LC analysis, provides a simple, and selective tool for the analysis of parabens in cosmetic products using minimized volume of organic solvent as well as very small amount of the target sample. Chapter II presents the development of a molecularly imprinted extraction phase for the SPE analysis of parabens in human milk samples. The molecularly imprinted polymers, which are synthetic materials based on biomimetic systems, were synthesized by the sol-gel technology in the presence of the template (benzilparaben). After template removal, selective cavities (benzilparaben) were revealed for parabens selective extraction. The linear range of the SPE/LC method lay from LOQ to 150 ng. mL-1, with a coefficient of determination higher than 0.992. The interday precision of the SPE/LC method presented a coefficient of variation lower than 13%, and the accuracy ranged from 86 to 117%. The effectiveness of the proposed method for the analysis of human milk samples has been demonstrated. According to the evaluated analytical validation parameters, the SPE/LC-UV method is suitable for the analysis of parabens in human milk samples. Chapter III depicts the evaluation of solid-phase microextraction in the capillary (in-tube SPME) in combination with liquid chromatography (LC) with UV detection (LC-UV) for the analysis of rifampicin in plasma samples for therapeutic drug monitoring. The in-tube SPME/LC method was linear over the LOQ (0.1) to 100 g. mL-1 range, with a linear coefficient value (r2) of 0.998. The inter-assay precision presented coefficient of variation 2%, and the accuracy ranged from 83 to 92%. The effectiveness and practicability of the proposed method have been by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. The in-tube SPME/LC method allowed for automated continuous sample preparation (extraction, concentration, desorption, and injection of analytes) and minimized the analysis time as well as the volumes of organic solvent and biological fluid.
8

Capturing molecules with templated materials: analysis and rational design of molecularly imprinted polymers

Wei, Shuting 09 July 2007 (has links)
Advantages such as chemical, mechanical and thermal stability together with high selectivity for the templated analyte render molecularly imprinted polymers MIPs interesting alternatives to routinely applied separation materials or antibodies. Nevertheless, many factors such as the choice of functional monomer, cross-linker, and porogenic solvent, as well as the ratio between template, functional monomer, and cross-linker will affect the resulting imprinting efficiency and polymer particle size and morphology. The research described in this thesis contributes to the development of new synthetic strategies for the generation of imprinted micro- and nanospheres for 17beta-estradiol (E2) focusing on accurate control and optimization of the governing parameters for precipitation polymerization, including the polymerization temperature and the cross-linker, yielding a one-step synthetic approach with superior control on the bead diameter, shape, monodispersity and imprinting efficiency. Thus synthesized imprinting materials for E2 were successfully applied in HPLC separation, solid phase extraction and radioligand binding assays. As the optimization of imprinted materials is based on fundamental understanding of the binding site properties, the investigations is aimed at establishing a more rational basis for further tailoring imprinted materials to the desired analytical application. The relationships between the particle porosity and rebinding properties were detailed, providing useful guidelines for controlling the particle properties for the desired application including, SPE pre-concentration, HPLC separations, and biomimetic binding assays. Furthermore, analytical techniques (1H-NMR and IR, etc.) and molecular modeling were combined in this thesis to facilitate advanced understanding of the fundamental principles governing selective recognition of molecularly imprinted polymers at a molecular level. The molecular interactions involved in the templating process of molecularly imprinted polymers based on the self-assembly approach were simulated in molecular dynamic simulation model by building a modeling system include all the imprinting components with correct ratio, which has never been reported before. Molecular level interactions such as hydrogen bonding, π-π stacking interactions as well as the free energy governing complex formation of E2 with the functional monomers 4-vinylpyridine (4VP) and methacrylic acid (MAA), and the cross-linker divinylbenzene (DVB) were discussed.
9

Desenvolvimento de método para determinação de acetaldeído em álcool etílico hidratado combustível por cromatografia líquida de alta eficiência com detecção eletroquímica

Okumura, Leonardo Luiz [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T19:38:10Z : No. of bitstreams: 1 okumura_ll_me_araiq.pdf: 737796 bytes, checksum: fb5e89571c23b9fd419cea4f1ac1559e (MD5) / O comportamento cíclico voltamétrico do acetaldeído e seu derivado foi estudado em eletrodo de gota pendente de mercúrio e carbono vítreo. Este estudo foi utilizado na otimização das condições para a detecção eletroquímica desses compostos por Cromatografia Líquida de Alta Eficiência (C.L.A.E.). O acetaldeído foi derivado com 2,4-dinitrofenilhidrazina (DNPHi) e o produto, a 2,4-dinitrofenilhidrazona do acetaldeído (AcH-DNPHo) foi eluida e separada por coluna de fase reversa C18 em condições isocráticas com fase móvel contendo uma mistura binária de metanol-solução aquosa de cloreto de lítio (LiCl) com concentração de 1,0 ´ 10-3 M (80:20% v/v) e vazão de 1,0 mL min-1. A detecção eletroquímica (D.E.) do AcH-DNPHo foi realizada por C.L.A.E. com potencial fixado em + 1,0 V vs eletrodo de referência Ag/AgCl. O método proposto foi simples, rápido (tempo de análise 7 min.), com limite de detecção 3,80 mg L-1, altamente seletivo, e reprodutível [desvio padrão relativo 8,2% (n=12)]. A curva analítica do AcH-DNPHo foi linear na faixa compreendida de 0 - 300 mg L-1, com índice de correlação linear 0,9998. A concentração de acetaldeído determinada em amostras de álcool combustível foi de 83 – 341 mg L–1 com desvio padrão de 1 – 6 %, na variação da área de pico e recuperação superior a 99%. A quantidade do teor de acetaldeído encontrado nestas amostras foi significativamente alta e os resultados obtidos foram comparados com o método de detecção espectrofotométrica (UV/Vis) / The cyclic voltammetric behaviour of acetaldehyde and their derivatives has been studied at a hanging drop mercury and glassy carbon electrode. This study was used to optimise the conditions for the electrochemical detection of these compounds following high-performance liquid chromatographic (H.P.L.C.) separation. The acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPHi) and the product 2,4-dinitrophenylhydrazone (AcH-DNPHo) was eluted and separated by reversed-phase column C18 in isocratic conditions with mobile phase containing binary mixture of methanol-chloride littium aqueous solution with concentration 1,0 ´ 10-3 M (80:20% v/v) and flow rate of 1.0 mL min-1. The electrochemical detection (E.D.) of AcH-DNPHo was performed by H.P.L.C. set at +1.0 V vs Ag/AgCl as reference electrode. The proposed method was simple, rapid (analysis time 7 min), with detection limit 3.80 mg L-1, highly selective, and reproducible [relative standard deviation 8.2 % (n=12)]. The calibration graph for AcH-DNPHo was linear in the range of 0 – 300 mg L-1 with correlation coefficient 0,9998. The concentrations of acetaldehyde determined in fuel alcohol samples was in the range of 83 – 341 mg L–1 with standard deviation of 1 – 6 %, in peak area variation and analytical recovery was >99%. The amount of acetaldehyde content found in these samples was significantly higher and the results obtained were compared to the spectrofotometric detection method (UV/Vis)
10

Desenvolvimento e validação de metodologia para medicamentos contendo dipirona sódica e cloridrato de papaverina isolados e em associação / Develop and validate analytical methods for determination of dipyrone sodium and papaverine hydrochloride in pharmaceutical preparations

Nascimento, Andréia Peraro do 31 January 2006 (has links)
A dipirona sódica em associação com o cloridrato de papaverina é usada como medicamento analgésico e antiespasmódico. O objetivo desta pesquisa foi o desenvolvimento e validação de métodos analíticos para a determinação de dipirona sódica e cloridrato de papaverina em preparações farmacêuticas. A solução oral contendo dipirona sódica isolada e a solução oral contendo a associação de dipirona sódica e cloridrato de papaverina foram determinadas por cromatografia líquida de alta eficiência, com as condições padronizadas: Coluna cromatográfica: Supelcosil C18 - LCPH (250 mm X 4,6 mm, 5µm) Supelco e pré coluna C -18 (20 X 4,6 mm, 5µm) Supelco, fase móvel: água: acetonitrila: metanol (70: 20: 10) trietilamina 0,3% e pH: 3,0 ajustado com ácido ortofosfórico, vazão de 0,7 mL/min e detecção no UV a 254 nm. Para a solução injetável contendo cloridrato de papaverina foi padronizado e validado o método por cromatografia líquida de alta eficiência, empregando coluna cromatográfica Merck LiChrospher® 100 RP - 18 (125 X 4,6 mm, 5µm), fase móvel: água : acetonitrila : metanol ( 70 : 20 : 10 ) trietilamina 0,3% e pH: 3,0 ajustado com ácido ortofosfórico, vazão: 1,0 mL/min e detecção no UV a 254 nm. Para a determinação simultânea de dipirona sódica e cloridrato de papaverina em solução oral, foi desenvolvida uma nova metodologia utilizando espectrofotometria na região do ultravioleta (UV) e calibração multivariada. Neste sistema, utilizou-se a faixa de leitura: 210 a 300 nm (passo 0,5 nm) e metanol como solvente. A calibração foi feita com 25 soluções nas concentrações de 15,0 a 35,0 µg/mL para a dipirona sódica e de 0,5 a 1,5 µg/mL para o cloridrato de papaverina. As curvas de calibração foram lineares. Os excipientes das amostras não interferiram nas metodologias. Foram apresentados adequados resultados de desvio padrão e média de recuperação. Os métodos propostos mostraram especificidade, precisão e exatidão para a determinação de dipirona sódica e cloridrato de papaverina em formulações farmacêuticas. / Dipyrone sodium and papaverine hydrochloride are used as an analgesic and antispasmodic drugs. The objective of this study was to develop and validate analytical methods for determination of dipyrone sodium and papaverine hydrochloride in pharmaceutical preparations. The commercial formulations with dipyrone hydrochloride alone and its combination with papaverine hydrochloride were analysed by liquid chromatography. A Supelcosil C18 - LCPH column (250 X 4.6 mm, 5µm) Supelco and a mobile phase constituted by water: acetonitrile: methanol (70:20:10), with 0.3% of triethylamine and pH adjusted to 3.0 with phosphoric acid were used. The flow rate was 0.7 mL/min and UV detection at 254 nm. The injection formulation with papaverine hydrochloride was analysed by a high performance liquid chromatographic method. The method was standardized and validated using a Merck LiChrospher® 100 RP 18 column (125 X 4.6 mm, 5µm) and a mobile phase constituted of water: acetonitrile: methanol (70:20:10), with 0.3% of triethylamine and pH adjusted to 3.0 with phosphoric acid. The flow rate was 1.0 mL/min and UV detection at 254 nm. The same oral solution with the combination of dipyrone sodium and papaverine hydrochloride was also quantified by UV spectrophotometry using multivariate calibration, in the range of 210 to 300 nm. The calibration set was constructed with twenty-five solutions in the concentration ranges from 15.0 to 35.0 µg mL-1 for dipyrone sodium and 0.5 to 1.5 µg mL-1 for papaverine hydrochloride in methanol. The results show that the methods presented good relative standard deviation and good recovery values. The obtained data indicates specificity, precision and accuracy of the proposed methods for the simultaneous determination of dipyrone sodium and papaverine hydrochloride in pharmaceutical formulations.

Page generated in 0.1076 seconds