Spelling suggestions: "subject:"lung colume remeasurements"" "subject:"lung colume aremeasurements""
11 |
Influência da atuação fisioterapêutica e intensidade da dor na função respiratória em pacientes submetidos à cirurgia cardíaca eletiva / Influence of physiotherapy approach and pain intensity in respiratory function in patients undergoing elective cardiac surgerySasseron, Ana Beatriz 15 August 2018 (has links)
Orientadores: Ilka de Fátima Santana Ferreira Boin, Sebastião Araújo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-15T23:52:43Z (GMT). No. of bitstreams: 1
Sasseron_AnaBeatriz_M.pdf: 872264 bytes, checksum: 6bc1e73ee6b6ee241a3baa5d4991e69f (MD5)
Previous issue date: 2010 / Resumo: Antecedentes: A fisioterapia pré-operatória em cirurgia cardíaca (CC) visa amenizar a disfunção respiratória e prevenir ou tratar complicações pulmonares comuns no período pós-operatório (PO). Objetivos: Avaliar a influência da fisioterapia respiratória pré-operatória e a intensidade da dor pós-operatória referida em determinadas variáveis utilizadas para a mensuração da função respiratória em pacientes submetidos à CC eletiva com circulação extracorpórea (CEC). Desenho: Pesquisa prospectiva, de coorte longitudinal, por amostra de conveniência. Local: Hospital da Irmandade Santa Casa de Misericórdia de Araras. Período: Agosto a dezembro de 2007. Método: Foram estudados 35 pacientes. As variáveis que avaliaram a função respiratória: força muscular respiratória, volume corrente (VC), volume minuto (VM), frequência respiratória (FR) e capacidade vital (CV) foram obtidas nos momentos: pré-operatório (PRE-OP) e PO (1°, 3° e 5°PO). A dor PO referida foi correlacionada com a disfunção respiratória. Baseado na mediana do número de sessões de fisioterapia PRE-OP realizadas, os pacientes foram divididos em Grupo 1 (pacientes que realizaram menor número de sessões) e Grupo 2 (pacientes que realizaram maior número de sessões). Os pacientes seguiram a rotina de atendimento fisioterapêutico local no PO. Resultados: Quinze pacientes compuseram o Grupo 1 (= 6 sessões) e 20 o Grupo 2 (= 8 sessões). As comparações das variáveis categóricas medidas no PRE-OP entre os grupos (idade, peso, altura, índice de massa corpórea e tempo de CEC), além das variáveis que avaliaram a função respiratória antes da CC não apresentaram diferenças significantes, evidenciando homogeneidade da amostra. Entretanto, a variável tempo total de cirurgia (média±desvio padrão) foi maior no grupo 2 (238,2±55,1 minutos versus 197,7±55,8 minutos no grupo 1, p=0,045). Houve predomínio de sujeitos do sexo masculino (73,3% no grupo 1 e 60,0% no grupo 2) e ex-tabagistas (73,3% no grupo 1 e 50,0% no grupo 2), predominando a cirurgia de revascularização do miocárdio (66,7% no grupo 1 e 70,0% no grupo 2). Em todas as variáveis da função respiratória estudadas, os valores obtidos no período PO foram menores em relação aos do PRE-OP em ambos os grupos e permaneceram abaixo até o 5°PO, com exceção do VM. Não houve diferença estatisticamente significante no comportamento das variáveis entre os grupos em relação aos tempos, com exceção do VC, que apresentou aumento significante (p = 0,029) entre os momentos 1º PO e 5º PO e 3º PO e 5º PO apenas para o grupo 2. Quanto maior foi a dor PO referida, maior foi a FR e menores foram os valores de VM e CV. O tempo de internação hospitalar foi similar entre os grupos. Conclusões: O número de sessões de fisioterapia PRE-OP não teve influência na evolução da função respiratória no PO de CC. A intensidade da dor pós-operatória referida influenciou de forma significante o aumento da FR e a diminuição do VM e da CV / Abstract: Background: Preoperative physiotherapy in cardiac surgery (CS) aims to minimize respiratory dysfunction and prevent or treat pulmonary complications common in postoperative period (PO). Purpose: To evaluate the influence of preoperative respiratory physiotherapy and the intensity of postoperative referred pain in certain variables of respiratory function measurements in patients undergoing elective CS with cardiopulmonary bypass (CPB). Design: Prospective and longitudinal cohort with a convenience sample. Setting: Hospital of the Santa Casa de Misericórdia de Araras. Period: August to december of 2007. Method: Thirty-five patients were studied. Respiratory function variables [respiratory muscle strength, tidal volume (TV), minute volume (MV), respiratory rate (RR) and vital capacity (VC)] were obtained at preoperative period (PP) and postoperative moments (1st, 3rd e 5th PO). Referred postoperative pain was correlated with respiratory dysfunction. Based on median of the number of preoperative physiotherapy sessions performed, patients were allocated into two groups: Group 1 (patients with fewer sessions) and group 2 (more sessions). Patients followed the local routine for physiotherapy at PO. Results: Fifteen patients composed the group 1 (6 sessions) and 20 the group 2 (= 8 sessions). Categorical variables obtained at PP period and compared between the two groups (age, weight, height, body mass index and CPB time), as well variables for respiratory function measurements, had not statistical differences, showing homogeneity of the casuistic. However, time of surgery (meanstandard deviation) was higher in group 2 (238.2±55.1 minutes versus 197.7±55.8 minutes in group 1, p=0.045). Overall, there was a predominance of male subjects (73.3% in group 1 and 60% in group 2), ex-smokers (73.3% in group 1 and 50.0% in group 2) and coronary artery bypass grafting (66.7 % in group 1 and 70.0% in group 2). All variables obtained in PO had lower values than those of PP for both groups, and remained bellow until the 5th PO day, with exception of the MV. When PO moments were evaluated, there was no statistical difference for variables performance between groups regarding the moments, with the exception of TV that presented significant increase (p = 0.029) between 1st and 5th PO; and 3rd and 5th PO only for group 2. Higher referred pain was seen with higher RR and with lower values of MV and VC. Both groups had similar hospital length of stay. Conclusions: The number of preoperative physiotherapy sessions had no influence on the evolution of respiratory function at the PO in CS. The intensity of postoperative referred pain influenced significantly the increase of RR and the reduction of MV and VC / Mestrado / Cirurgia / Mestre em Ciências Médicas
|
12 |
Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung modelCouto, Lara Poletto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.
|
13 |
Avaliação da correlação entre a tomografia de impedância elétrica e o volume corrente aplicado durante o suporte ventilatório mecânico invasivo / Evaluation of the correlation between electrical impedance tomography and tidal volume applied during mechanical invasive ventilatory supportHirota, Adriana Sayuri 12 December 2018 (has links)
Introdução: A tomografia de impedância elétrica (TIE) é uma técnica de imagem não invasiva que mensura o potencial elétrico na superfície torácica através de eletrodos colocados ao redor do tórax. Essas medidas são transformadas em uma imagem bidimensional da distribuição da impedância elétrica no tórax. Esse instrumento detecta modificações da densidade pulmonar e distribuição do volume corrente. Entretanto, é necessário melhor avaliação da sua eficiência em estimar o volume corrente (VT) a cada ciclo ventilatório. O objetivo do estudo é avaliar a correlação do volume estimado pela TIE com o VT aplicado durante o suporte ventilatório mecânico. Métodos: Inicialmente, foram estudados cinco suínos da raça Landrace. Os animais foram sedados, intubados e monitorados com a TIE. Foram aplicados volumes incrementais (100, 250, 500, 750 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 5, 10 e 20 cmH2O, antes e depois da promoção de lesão pulmonar com lavagem com solução salina. Posteriormente, outros cinco animais foram monitorados com a tomografia computadorizada de tórax por raios X (TC) e a TIE. Foram aplicados volumes incrementais (250, 500 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 10 e 20 cmH2O, também antes e depois da promoção de lesão pulmonar. A amplitude da variação de impedância mensurada pela TIE foi convertida em volume e foi calculado o volume de ar na TC. Análises de correlação e concordância foram realizadas com o programa \"R\" (© R Foundation for Statistical Computing). Resultados: Em ZEEP, o coeficiente de correlação entre os volumes estimado pela TIE e calculado pela TC foram, respectivamente, 0,90 e 0,96 na comparação com a seringa de precisão. O coeficiente de determinação entre a TIE e a seringa de precisão foi progressivamente reduzindo (0,90; 0,89 e 0,81 com PEEP de 5; 10 e 20, respectivamente) com o aumento do volume pulmonar promovido pela elevação da PEEP. A TC mostrou um deslocamento progressivo do conteúdo aéreo no sentido caudal com o aumento do volume pulmonar. Conclusões: Há uma boa correlação entre o volume estimado pela TIE e o VT aplicado durante o suporte ventilatório mecânico quando utilizados volumes e pressões usuais na prática clínica / Rationale: Electrical impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of the lung\'s regional conductivity using electrodes placed circumferentially around the thorax. It is able to detect changes of lung air content and tidal volume (VT) distribution. However, better evaluation of its capacity to quantify VT variations is necessary. The aim of our study was to assess the correlation between volume estimated by EIT and tidal volume applied at different positive end-expiratory pressures (PEEP). Methods: Initially, in an experimental study five mechanically ventilated pigs monitored by EIT were studied. VT increments (100, 250, 500, 750 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 5, 10 and 20 cmH2O before and after lung-injury (induced by saline lavage). Another five pigs was monitored by EIT and x-ray computed tomography (CT). VT increments (250, 500 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 10 and 20 cmH2O before and after lung-injury. Lung air volume was calculated at CT scan and the amplitude of impedance change measured by EIT was converted to volume (mL). Correlation and agreement analysis was performed at \"R\" program (© R Foundation for Statistical Computing). Results: At ZEEP, volume estimated by EIT and volume calculated at CT obtained r2 = 0.90 and 0.96 respectively, when compared to calibrated syringe. The coefficient of correlation between EIT and calibrated syringe impaired (0.90; 0.89 and 0.81 with PEEP of 5; 10 and 20, respectively) with increase of the lung volume due to increased PEEP. CT showed a progressive displacement of the air content to the caudal thoracic levels with the increase of the lung volume. Conclusion: EIT is able to estimate tidal volume during mechanical ventilatory support when used volumes and pressures usually applied at bedside
|
14 |
Avaliação da correlação entre a tomografia de impedância elétrica e o volume corrente aplicado durante o suporte ventilatório mecânico invasivo / Evaluation of the correlation between electrical impedance tomography and tidal volume applied during mechanical invasive ventilatory supportAdriana Sayuri Hirota 12 December 2018 (has links)
Introdução: A tomografia de impedância elétrica (TIE) é uma técnica de imagem não invasiva que mensura o potencial elétrico na superfície torácica através de eletrodos colocados ao redor do tórax. Essas medidas são transformadas em uma imagem bidimensional da distribuição da impedância elétrica no tórax. Esse instrumento detecta modificações da densidade pulmonar e distribuição do volume corrente. Entretanto, é necessário melhor avaliação da sua eficiência em estimar o volume corrente (VT) a cada ciclo ventilatório. O objetivo do estudo é avaliar a correlação do volume estimado pela TIE com o VT aplicado durante o suporte ventilatório mecânico. Métodos: Inicialmente, foram estudados cinco suínos da raça Landrace. Os animais foram sedados, intubados e monitorados com a TIE. Foram aplicados volumes incrementais (100, 250, 500, 750 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 5, 10 e 20 cmH2O, antes e depois da promoção de lesão pulmonar com lavagem com solução salina. Posteriormente, outros cinco animais foram monitorados com a tomografia computadorizada de tórax por raios X (TC) e a TIE. Foram aplicados volumes incrementais (250, 500 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 10 e 20 cmH2O, também antes e depois da promoção de lesão pulmonar. A amplitude da variação de impedância mensurada pela TIE foi convertida em volume e foi calculado o volume de ar na TC. Análises de correlação e concordância foram realizadas com o programa \"R\" (© R Foundation for Statistical Computing). Resultados: Em ZEEP, o coeficiente de correlação entre os volumes estimado pela TIE e calculado pela TC foram, respectivamente, 0,90 e 0,96 na comparação com a seringa de precisão. O coeficiente de determinação entre a TIE e a seringa de precisão foi progressivamente reduzindo (0,90; 0,89 e 0,81 com PEEP de 5; 10 e 20, respectivamente) com o aumento do volume pulmonar promovido pela elevação da PEEP. A TC mostrou um deslocamento progressivo do conteúdo aéreo no sentido caudal com o aumento do volume pulmonar. Conclusões: Há uma boa correlação entre o volume estimado pela TIE e o VT aplicado durante o suporte ventilatório mecânico quando utilizados volumes e pressões usuais na prática clínica / Rationale: Electrical impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of the lung\'s regional conductivity using electrodes placed circumferentially around the thorax. It is able to detect changes of lung air content and tidal volume (VT) distribution. However, better evaluation of its capacity to quantify VT variations is necessary. The aim of our study was to assess the correlation between volume estimated by EIT and tidal volume applied at different positive end-expiratory pressures (PEEP). Methods: Initially, in an experimental study five mechanically ventilated pigs monitored by EIT were studied. VT increments (100, 250, 500, 750 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 5, 10 and 20 cmH2O before and after lung-injury (induced by saline lavage). Another five pigs was monitored by EIT and x-ray computed tomography (CT). VT increments (250, 500 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 10 and 20 cmH2O before and after lung-injury. Lung air volume was calculated at CT scan and the amplitude of impedance change measured by EIT was converted to volume (mL). Correlation and agreement analysis was performed at \"R\" program (© R Foundation for Statistical Computing). Results: At ZEEP, volume estimated by EIT and volume calculated at CT obtained r2 = 0.90 and 0.96 respectively, when compared to calibrated syringe. The coefficient of correlation between EIT and calibrated syringe impaired (0.90; 0.89 and 0.81 with PEEP of 5; 10 and 20, respectively) with increase of the lung volume due to increased PEEP. CT showed a progressive displacement of the air content to the caudal thoracic levels with the increase of the lung volume. Conclusion: EIT is able to estimate tidal volume during mechanical ventilatory support when used volumes and pressures usually applied at bedside
|
15 |
Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung modelLara Poletto Couto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.
|
16 |
"Avaliação da relação entre espaço morto e volume corrente como índice preditivo de sucesso na retirada da ventilação mecânica de crianças gravemente enfermas" / Evaluation of the dead-space : tidal volume ratio as a predictor of success in the removal of mechanical ventilation of critically ill childrenBousso, Albert 26 August 2004 (has links)
O momento ideal para a extubação de crianças graves é ainda difícil de ser avaliado. A razão entre espaço morto e volume corrente (Vd/Vt), como valor preditiva de extubação bem sucedida, já foi testada em adultos e crianças. O objetivo deste trabalho foi avaliar a eficácia do Vd/Vt, como preditivo do sucesso da extubação, em crianças de uma UTI pediátrica geral. Após aplicação dos critérios de inclusão e exclusão, testou-se o Vd/Vt em 86 pacientes extubados num período de 16 meses. Nos estudos estatísticos o índice Vd/Vt médio não discriminou os grupos de falha e sucesso na extubação nas análises uni e multivariada. O valor do índice, com corte em 0,65, foi limitado na sensibilidade e especificidade e mediano na razão de verossimilhança. O estudo sugere que o índice Vd/Vt, pode ser considerado como complementar aos dados de avaliação clínica no momento da extubação. / The ideal moment for extubation of critically ill children is still difficult to determine. The dead-space : tidal volume ratio (Vd/Vt) has been tested as predictor of extubation failure in adults and children. The purpose of this study was to evaluate the efficacy of the Vd/Vt as a predictor of the success of extubation in children admitted to a pediatric intensive care unit. After the inclusion and exclusion criteria, 86 patients were studied during 16 months. The statistical study revealed that the mean Vd/Vt was not able to discriminate between failure and success of extubation in the multivariate analysis. The utility of the Vd/Vt was limited, in terms of sensibility and specificity, using a cutoff of 0,65, but was medially satisfactory in the likelihood ratio. This study suggests that the Vd/Vt can only be considered as complementary to the routine clinical evaluation prior to extubation.
|
17 |
"Avaliação da relação entre espaço morto e volume corrente como índice preditivo de sucesso na retirada da ventilação mecânica de crianças gravemente enfermas" / Evaluation of the dead-space : tidal volume ratio as a predictor of success in the removal of mechanical ventilation of critically ill childrenAlbert Bousso 26 August 2004 (has links)
O momento ideal para a extubação de crianças graves é ainda difícil de ser avaliado. A razão entre espaço morto e volume corrente (Vd/Vt), como valor preditiva de extubação bem sucedida, já foi testada em adultos e crianças. O objetivo deste trabalho foi avaliar a eficácia do Vd/Vt, como preditivo do sucesso da extubação, em crianças de uma UTI pediátrica geral. Após aplicação dos critérios de inclusão e exclusão, testou-se o Vd/Vt em 86 pacientes extubados num período de 16 meses. Nos estudos estatísticos o índice Vd/Vt médio não discriminou os grupos de falha e sucesso na extubação nas análises uni e multivariada. O valor do índice, com corte em 0,65, foi limitado na sensibilidade e especificidade e mediano na razão de verossimilhança. O estudo sugere que o índice Vd/Vt, pode ser considerado como complementar aos dados de avaliação clínica no momento da extubação. / The ideal moment for extubation of critically ill children is still difficult to determine. The dead-space : tidal volume ratio (Vd/Vt) has been tested as predictor of extubation failure in adults and children. The purpose of this study was to evaluate the efficacy of the Vd/Vt as a predictor of the success of extubation in children admitted to a pediatric intensive care unit. After the inclusion and exclusion criteria, 86 patients were studied during 16 months. The statistical study revealed that the mean Vd/Vt was not able to discriminate between failure and success of extubation in the multivariate analysis. The utility of the Vd/Vt was limited, in terms of sensibility and specificity, using a cutoff of 0,65, but was medially satisfactory in the likelihood ratio. This study suggests that the Vd/Vt can only be considered as complementary to the routine clinical evaluation prior to extubation.
|
Page generated in 0.0809 seconds