  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Suscetibilidade de pastas de cimento ao ataque por sulfatos - método de ensaio acelerado. / Susceptibility of cement pastes to sulfate attack - accelerated test method.

Souza, Rui Barbosa de 03 February 2006 (has links)
O presente trabalho tem por objetivo investigar e propor uma metodologia rápida e eficaz de avaliação da reatividade do cimento Portland frente ao ataque por sulfatos. O método consiste na utilização de amostras de pasta de cimento hidratada em pó, colocadas em contato direto com soluções concentradas de Na2SO4 e MgSO4, em temperatura elevada (65ºC), para acelerar o ataque. Apesar dos cimentos estudados possuírem composição química parecida, os resultados de SO3 combinado mostraram que o cimento Classe G foi pouco menos suscetível ao ataque por sulfatos em função do maior teor de Fe2O3 presente. Da TG e DRX observou-se a formação de etringita no ataque por ambos os sais de sulfato; e formação de gipsita no ataque por MgSO4. Enquanto havia disponibilidade de portlandita na pasta hidratada, o cimento com adição mineral incorporada apresentou mesma taxa de ataque que os demais (sem adição), entretanto a partir do momento que toda a portlandita foi consumida, iniciou-se um processo de descalcificação do C-S-H, observado pela DRX. / The main point of this research is to propose a fast and effective method of evaluation of the cement reactivity to sulfate attack. Resistance to sulfate attack was measured by determining the combined sulfate in cement paste samples with exposure to Na2SO4 and MgSO4 solution, at high temperature (65°C). The samples of cement paste was triturated (powdered) in the proposed method. The results of combined SO3 showed that the Class G cement was little less susceptible to the sulfate attack because it has larger amount of Fe2O3. The ettringite formation was observed in the attack for both sulfate salts; and gypsum formation in the attack for MgSO4 (results of TG and XRD). The blended cement presented same results that the others, however when the Ca(OH)2 was totally consumed, it observed the decalcification of the C-S-H, by XRD.
2

Suscetibilidade de pastas de cimento ao ataque por sulfatos - método de ensaio acelerado. / Susceptibility of cement pastes to sulfate attack - accelerated test method.

Rui Barbosa de Souza 03 February 2006 (has links)
O presente trabalho tem por objetivo investigar e propor uma metodologia rápida e eficaz de avaliação da reatividade do cimento Portland frente ao ataque por sulfatos. O método consiste na utilização de amostras de pasta de cimento hidratada em pó, colocadas em contato direto com soluções concentradas de Na2SO4 e MgSO4, em temperatura elevada (65ºC), para acelerar o ataque. Apesar dos cimentos estudados possuírem composição química parecida, os resultados de SO3 combinado mostraram que o cimento Classe G foi pouco menos suscetível ao ataque por sulfatos em função do maior teor de Fe2O3 presente. Da TG e DRX observou-se a formação de etringita no ataque por ambos os sais de sulfato; e formação de gipsita no ataque por MgSO4. Enquanto havia disponibilidade de portlandita na pasta hidratada, o cimento com adição mineral incorporada apresentou mesma taxa de ataque que os demais (sem adição), entretanto a partir do momento que toda a portlandita foi consumida, iniciou-se um processo de descalcificação do C-S-H, observado pela DRX. / The main point of this research is to propose a fast and effective method of evaluation of the cement reactivity to sulfate attack. Resistance to sulfate attack was measured by determining the combined sulfate in cement paste samples with exposure to Na2SO4 and MgSO4 solution, at high temperature (65°C). The samples of cement paste was triturated (powdered) in the proposed method. The results of combined SO3 showed that the Class G cement was little less susceptible to the sulfate attack because it has larger amount of Fe2O3. The ettringite formation was observed in the attack for both sulfate salts; and gypsum formation in the attack for MgSO4 (results of TG and XRD). The blended cement presented same results that the others, however when the Ca(OH)2 was totally consumed, it observed the decalcification of the C-S-H, by XRD.
3

Chapas metálicas perfuradas para proteção solar. Avaliação do desempenho térmico e luminoso / Perforated metal sheet for shading. Assessment of solar-optical performance

Minioli, Alda Regina Bueno 16 April 2014 (has links)
Neste trabalho é realizada a avaliação do desempenho solar e luminoso de chapas metálicas com diferentes padrões de perfurações empregados para proteção solar na envoltória das edificações. Foram ensaiadas experimentalmente as transmitâncias solar e luminosa em diversos ângulos de incidência de chapas metálicas, chapas expandidas e telhas metálicas, com ou sem pintura, planas ou com conformação espacial. Avaliou-se a relação entre a transmitância e % de perfuração da amostra para incidência da radiação em variadas alturas e azimutes solares, comparou-se o comportamento solar e luminoso de cada amostra e entre amostras com características semelhantes. As normas ASTM E972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight e ASTM E1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight foram adotadas para medições de campo das amostras. Os resultados mostram que, para todas as amostras, as transmitâncias solar (TS) e luminosa (TL) na perpendicular se assemelham a % de perfuração da amostra; para ângulos diferentes da normal há uma redução conforme a altura solar diminui e que quanto maior for o furo em relação à espessura, menor será a redução. TS/TL decresce conforme a altura solar diminui, exceto para as telhas. Em relação à variação de azimute, para chapas perfuradas sem acabamento ou pintadas, os valores de TS e TL se mantêm praticamente iguais, enquanto que para chapas expandidas e telhas os valores variam. Para as amostras pintadas, TS e TL das amostras com cores claras são maiores do que das amostras com cores médias que por sua vez são maiores do que as amostras com cores escuras. A partir destes resultados e da elaboração da ficha de aplicação dos resultados para variados ângulos, no âmbito do projeto de arquitetura, contribui-se para o emprego apropriado deste tipo de material, além de complementar informações técnicas pouco disponíveis no mercado. Além disso, os dados medidos em campo podem servir de validação para modelagem computacional para uma variação maior de ângulos, e na avaliação de ambientes projetados ou construídos, os dados coletados, em especial os ângulos diferentes da incidência normal, podem ser usados em simulação energética ao longo do ano. / This research focuses on the evaluation of solar and optical performance of metal sheets with different patterns of perforations used as shading devices in the building\'s envelope. Solar and light transmittance were experimentally tested at normal and off-normal incident angles of samples of perforated metal sheet, expanded metal sheets and perforated tile, with or without painting, flat or volumetric shape. The relationship between % perforation of sample and transmittance for off normal angle incidence (height and azimuth) was evaluated. Solar and optical results were correlated for each sample. Samples with similar characteristics such as perforation, painting, hole dimension were compared. ASTM E 972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight and ASTM E 1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight were adopted for field measurements of the samples. The results show that for all samples, the solar transmittance (TS) and light (TL) perpendicular to the sample is similar to % perforation; for off normal angles there is a reduction as the solar altitude decreases and that the higher the hole relative to thickness, the smaller the reduction. TS / TL decreases as solar height decreases, except for the tiles. Regarding the change in azimuth for perforated sheets with or without painting, the values of TL and TS remains practically the same, whereas for expanded metal and tiles values vary. For the painted samples, TS and TL bright color of the samples are higher than the intermediate color samples which are in turn higher than the samples of dark colors. From the results achieved and with the development of the application table to diferente incident angles, within the architecture field, these results provide information for the appropriate use of such material, plus some additional technical information available in the market. Furthermore, the data measured in the field can serve as validation for computational modeling to a wider range of angles, and also it could be used in buildings\' energy simulations.
4

Ensaio de compressão de corpo de prova com duplo corte em cunha na avaliação de concretos com baixos teores de fibra de aço. / Double edge wedge splitting test to evaluate fibre reinforced concretes with low steel fibre content.

Borges, Leonardo Augusto Cruz 08 December 2016 (has links)
A melhor maneira de se caracterizar o comportamento mecânico pós-fissuração dos concretos reforçados com fibras (CRF) para fins estruturais é por meio de ensaios que envolvem a ruptura do material à tração direta. Devido às dificuldades de execução destes, comumente se empregam ensaios de tração indireta, com destaque para os ensaios de flexão com sistema fechado. Entretanto, fatores limitantes, como a superestimação da capacidade resistente do compósito em testes de flexão, têm incentivado o desenvolvimento de outros métodos de ensaio mais fidedignos às características do CRF. Este é o caso do ensaio de compressão de corpo de prova com duplo corte em cunha, abreviado como DEWS (do inglês, Double Edge Wedge Splitting), em que o esforço de tração indireta não está associado a uma flecha, como nos ensaios de flexão, mas sim à própria fissuração da matriz de concreto. No DEWS há a possibilidade de avaliação direta da ortotropia do CRF e seu efeito na resistência pós-fissuração no estado limite de serviço (ELS) e último (ELU). Estudos anteriores sobre este ensaio utilizaram sistema aberto, mas se restringiram a avaliar apenas elevados teores de fibra, o que não traz dificuldades à caracterização da resistência residual no ELS. Este trabalho, contudo, buscou o estudo mais acurado a respeito do ensaio DEWS. Os programas experimentais desenvolvidos empregaram concretos reforçados com baixos teores de fibra de aço. Inicialmente, estudou-se a capacidade do ensaio DEWS em identificar o efeito da orientação das fibras na matriz na resistência pós-fissuração do CRF. Essa análise foi correlacionada com os resultados obtidos a partir de ensaios de flexão de prismas feitos como recomendado pela JSCE-SF4, assim, buscou-se avaliar se este teste promove uma superestimação da capacidade de reforço da fibra. Uma outra avaliação centrou-se no fator da taxa de carregamento de ensaio, realizando-se a metodologia DEWS e o teste de flexão (JSCE-SF4: 1984) sob quatro velocidades distintas, com intuito de verificar seu grau de influência no comportamento do material. A partir dos resultados obtidos, o ensaio DEWS mostrou-se aplicável na avaliação da ortotropia de corpos de prova em concretos reforçados com baixos teores de fibra de aço, mesmo com a utilização de sistema aberto e em velocidade de carregamento acima da proposta em literatura. A extensão da instabilidade pós-fissuração obtida a partir do ensaio DEWS foi menor que a encontrada para o ensaio de flexão de prismas. O estudo mostrou que a capacidade resistente pós-fissuração do CRF no ensaio de flexão pode ser até 300% maior do que a mesma resistência medida na direção transversal do prisma. / The best way to characterize the post-cracking behaviour of fibre reinforced concretes (FRC) for structural proposes is through direct tensile tests. As direct tensile tests are difficult to conduce, usually indirect tensile tests are employed, especially bending tests with closed-loop control. However, limiting factors, as the strength capacity overestimation of composites under flexural beams tests had motivated the development of another test procedure aiming to obtain responses closer to FRC basic characteristics. This is the case of Double Edge Wedge Splitting test (DEWS). In this test, the indirect tensile stress is not associated with a deflection - as is common in bending tests - but it is related with the cracking opening of concrete matrix. The DEWS test brings the possibility of direct evaluation of the FRC orthotropic behaviour and its effect in the post-crack strength at the serviceability (SLS) and ultimate (ULS) limit estates. Previous researches about DEWS test were done using open-loop control, but they were limited to higher fibre content. These do not provide difficulties about the residual strength characterization at the SLS. Thus, this study carried out an accurate experimental analysis about DEWS. This experimental programme used only fibre reinforced concrete with low steel fibre volume fractions. The first analysis was based in the DEWS test capacity for identification of the effect of predominant fibre orientation into matrix in the post-crack strength of the FRC. This analysis was linked with the flexural test made with prismatic specimens as recommended by JSCE-SF4 in order to evaluate if it promotes an overestimation of the fibre reinforcement capacity. The other evaluation focused on the test loading rate factor by doing DEWS test and bending test (JSCE-SF4:1984) under four different rates in order to verify its influence on the material behaviour. The results shown that DEWS test was capable to identify the fibre alignment into FRC specimens with low fibre content, even using open-loop control and increasing the load rate. The extension of the instability region on DEWS test response was lower than the provided by the flexural tests. The study also showed that the flexural test could overestimate the post-crack strength capacity of the FRC up 300% in relation to the transversal direction.
5

Chapas metálicas perfuradas para proteção solar. Avaliação do desempenho térmico e luminoso / Perforated metal sheet for shading. Assessment of solar-optical performance

Alda Regina Bueno Minioli 16 April 2014 (has links)
Neste trabalho é realizada a avaliação do desempenho solar e luminoso de chapas metálicas com diferentes padrões de perfurações empregados para proteção solar na envoltória das edificações. Foram ensaiadas experimentalmente as transmitâncias solar e luminosa em diversos ângulos de incidência de chapas metálicas, chapas expandidas e telhas metálicas, com ou sem pintura, planas ou com conformação espacial. Avaliou-se a relação entre a transmitância e % de perfuração da amostra para incidência da radiação em variadas alturas e azimutes solares, comparou-se o comportamento solar e luminoso de cada amostra e entre amostras com características semelhantes. As normas ASTM E972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight e ASTM E1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight foram adotadas para medições de campo das amostras. Os resultados mostram que, para todas as amostras, as transmitâncias solar (TS) e luminosa (TL) na perpendicular se assemelham a % de perfuração da amostra; para ângulos diferentes da normal há uma redução conforme a altura solar diminui e que quanto maior for o furo em relação à espessura, menor será a redução. TS/TL decresce conforme a altura solar diminui, exceto para as telhas. Em relação à variação de azimute, para chapas perfuradas sem acabamento ou pintadas, os valores de TS e TL se mantêm praticamente iguais, enquanto que para chapas expandidas e telhas os valores variam. Para as amostras pintadas, TS e TL das amostras com cores claras são maiores do que das amostras com cores médias que por sua vez são maiores do que as amostras com cores escuras. A partir destes resultados e da elaboração da ficha de aplicação dos resultados para variados ângulos, no âmbito do projeto de arquitetura, contribui-se para o emprego apropriado deste tipo de material, além de complementar informações técnicas pouco disponíveis no mercado. Além disso, os dados medidos em campo podem servir de validação para modelagem computacional para uma variação maior de ângulos, e na avaliação de ambientes projetados ou construídos, os dados coletados, em especial os ângulos diferentes da incidência normal, podem ser usados em simulação energética ao longo do ano. / This research focuses on the evaluation of solar and optical performance of metal sheets with different patterns of perforations used as shading devices in the building\'s envelope. Solar and light transmittance were experimentally tested at normal and off-normal incident angles of samples of perforated metal sheet, expanded metal sheets and perforated tile, with or without painting, flat or volumetric shape. The relationship between % perforation of sample and transmittance for off normal angle incidence (height and azimuth) was evaluated. Solar and optical results were correlated for each sample. Samples with similar characteristics such as perforation, painting, hole dimension were compared. ASTM E 972 Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight and ASTM E 1084 Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight were adopted for field measurements of the samples. The results show that for all samples, the solar transmittance (TS) and light (TL) perpendicular to the sample is similar to % perforation; for off normal angles there is a reduction as the solar altitude decreases and that the higher the hole relative to thickness, the smaller the reduction. TS / TL decreases as solar height decreases, except for the tiles. Regarding the change in azimuth for perforated sheets with or without painting, the values of TL and TS remains practically the same, whereas for expanded metal and tiles values vary. For the painted samples, TS and TL bright color of the samples are higher than the intermediate color samples which are in turn higher than the samples of dark colors. From the results achieved and with the development of the application table to diferente incident angles, within the architecture field, these results provide information for the appropriate use of such material, plus some additional technical information available in the market. Furthermore, the data measured in the field can serve as validation for computational modeling to a wider range of angles, and also it could be used in buildings\' energy simulations.
6

Ensaio de compressão de corpo de prova com duplo corte em cunha na avaliação de concretos com baixos teores de fibra de aço. / Double edge wedge splitting test to evaluate fibre reinforced concretes with low steel fibre content.

Leonardo Augusto Cruz Borges 08 December 2016 (has links)
A melhor maneira de se caracterizar o comportamento mecânico pós-fissuração dos concretos reforçados com fibras (CRF) para fins estruturais é por meio de ensaios que envolvem a ruptura do material à tração direta. Devido às dificuldades de execução destes, comumente se empregam ensaios de tração indireta, com destaque para os ensaios de flexão com sistema fechado. Entretanto, fatores limitantes, como a superestimação da capacidade resistente do compósito em testes de flexão, têm incentivado o desenvolvimento de outros métodos de ensaio mais fidedignos às características do CRF. Este é o caso do ensaio de compressão de corpo de prova com duplo corte em cunha, abreviado como DEWS (do inglês, Double Edge Wedge Splitting), em que o esforço de tração indireta não está associado a uma flecha, como nos ensaios de flexão, mas sim à própria fissuração da matriz de concreto. No DEWS há a possibilidade de avaliação direta da ortotropia do CRF e seu efeito na resistência pós-fissuração no estado limite de serviço (ELS) e último (ELU). Estudos anteriores sobre este ensaio utilizaram sistema aberto, mas se restringiram a avaliar apenas elevados teores de fibra, o que não traz dificuldades à caracterização da resistência residual no ELS. Este trabalho, contudo, buscou o estudo mais acurado a respeito do ensaio DEWS. Os programas experimentais desenvolvidos empregaram concretos reforçados com baixos teores de fibra de aço. Inicialmente, estudou-se a capacidade do ensaio DEWS em identificar o efeito da orientação das fibras na matriz na resistência pós-fissuração do CRF. Essa análise foi correlacionada com os resultados obtidos a partir de ensaios de flexão de prismas feitos como recomendado pela JSCE-SF4, assim, buscou-se avaliar se este teste promove uma superestimação da capacidade de reforço da fibra. Uma outra avaliação centrou-se no fator da taxa de carregamento de ensaio, realizando-se a metodologia DEWS e o teste de flexão (JSCE-SF4: 1984) sob quatro velocidades distintas, com intuito de verificar seu grau de influência no comportamento do material. A partir dos resultados obtidos, o ensaio DEWS mostrou-se aplicável na avaliação da ortotropia de corpos de prova em concretos reforçados com baixos teores de fibra de aço, mesmo com a utilização de sistema aberto e em velocidade de carregamento acima da proposta em literatura. A extensão da instabilidade pós-fissuração obtida a partir do ensaio DEWS foi menor que a encontrada para o ensaio de flexão de prismas. O estudo mostrou que a capacidade resistente pós-fissuração do CRF no ensaio de flexão pode ser até 300% maior do que a mesma resistência medida na direção transversal do prisma. / The best way to characterize the post-cracking behaviour of fibre reinforced concretes (FRC) for structural proposes is through direct tensile tests. As direct tensile tests are difficult to conduce, usually indirect tensile tests are employed, especially bending tests with closed-loop control. However, limiting factors, as the strength capacity overestimation of composites under flexural beams tests had motivated the development of another test procedure aiming to obtain responses closer to FRC basic characteristics. This is the case of Double Edge Wedge Splitting test (DEWS). In this test, the indirect tensile stress is not associated with a deflection - as is common in bending tests - but it is related with the cracking opening of concrete matrix. The DEWS test brings the possibility of direct evaluation of the FRC orthotropic behaviour and its effect in the post-crack strength at the serviceability (SLS) and ultimate (ULS) limit estates. Previous researches about DEWS test were done using open-loop control, but they were limited to higher fibre content. These do not provide difficulties about the residual strength characterization at the SLS. Thus, this study carried out an accurate experimental analysis about DEWS. This experimental programme used only fibre reinforced concrete with low steel fibre volume fractions. The first analysis was based in the DEWS test capacity for identification of the effect of predominant fibre orientation into matrix in the post-crack strength of the FRC. This analysis was linked with the flexural test made with prismatic specimens as recommended by JSCE-SF4 in order to evaluate if it promotes an overestimation of the fibre reinforcement capacity. The other evaluation focused on the test loading rate factor by doing DEWS test and bending test (JSCE-SF4:1984) under four different rates in order to verify its influence on the material behaviour. The results shown that DEWS test was capable to identify the fibre alignment into FRC specimens with low fibre content, even using open-loop control and increasing the load rate. The extension of the instability region on DEWS test response was lower than the provided by the flexural tests. The study also showed that the flexural test could overestimate the post-crack strength capacity of the FRC up 300% in relation to the transversal direction.