• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Elaboración de procedimientos de soldadura (WPS) en aceros aleados aplicables al Proyecto Modernización de la Refinería de Talara

Calderón Huicho, Yeremi Angel January 2020 (has links)
El documento digital no refiere asesor / Elabora los procedimientos de soldadura (WPS) en aceros aleados aplicables al Proyecto de Modernización de la Refinería de Talara. En el proceso de soldadura de tuberías para transportar líquidos y gases que son esenciales para el proceso de la refinería. El código ASME B31.3 (Process Piping) tiene requerimientos referidos a materiales usados, fabricación e instalación, inspección y pruebas en soldaduras de acero al carbono y baja aleación, usadas en la industria de las tuberías de procesos teniendo como objetivo desarrollar la normatividad técnica, elaborar y calificar los procedimientos específicos de soldadura (WPS) soportados con una calificación (PQR) bajo los requerimientos de ASME B31.3 (Process Piping); garantizando así una soldadura de alta calidad. En la parte experimental se analiza los ensayos mecánicos obtenidos por cada procedimiento de soldadura y ejecutados de acuerdo al código ASME Sección IX, concluyendo así que el código aplicado y los detalles de soldadura son favorecidos para su posterior uso en las industrias metalmecánicas siendo afines a la tecnología de soldadura, obteniendo así un producto terminado con óptima calidad debido a las altas exigencias aplicadas; siendo estos los puntos elementales que se rige en las buenas prácticas de la soldadura. / Trabajo de suficiencia profesional
2

Avaliação das condições operacionais de espectrômetro de emissão óptica com plasma acoplado indutivamente com configuração axial. / Evaluation of operating conditions of an inductively coupled plasma optical emission spectrometer with axially viewed configuration.

Trevizan, Lilian Cristina 23 February 2007 (has links)
Made available in DSpace on 2016-06-02T20:34:05Z (GMT). No. of bitstreams: 1 TeseLCT.pdf: 981864 bytes, checksum: 8f631caadb6c6abeb0178f29e14625aa (MD5) Previous issue date: 2007-02-23 / The goal of this thesis was the critical evaluation of the analytical capability of an inductively coupled plasma spectrometer (ICP OES) with axially viewed configuration. The general view that axially systems are mainly applied to samples with low matrix complexity was evaluated and the performance of this configuration was supposed to be similar to the one of radially viewed systems. Figures of merit such as stability, robustness, detection limits, linear dynamic range, precision and accuracy were monitored in function of equipment operating conditions, sample introduction system and the complexity of the sample matrix. Magnesium II / Mg I ratio showed to be an adequate parameter for evaluation of ICP OES operating conditions. Factorial design allowed the determination of robust conditions for different sample introduction systems and evidenced the inefficiency of the V-groove nebulizer when operated at low nebulization gas flow-rate. For this nebulizer, in contrast with the literature, robust conditions were attained at both high applied power and high nebulization gas flow-rate. Using robust conditions, lower detection limits were found and high accuracy was obtained for the analysis of complex samples of non-fat milk powder diluted in tertiary amines medium and austenitic steel decomposed with aqua regia. For alcoholic beverage analysis, it was necessary the use of similar alcoholic concentration for the reference solutions and samples in order to compensate transport effects due to the presence of organic compounds. However, deviations greater than 10 % were observed for some elements in wine analysis. The use of the standard additions method or matrix matching by Fe addition was not necessary for austenitic steel analysis and calibration was performed with reference solutions in aqua regia 1.2 % v v-1 medium. Severe matrix effects in axially viewed ICP OES configuration did not occur and this configuration was competitive with radially viewed systems. An additional advantage of axially systems is the lower detection limits. However, the use of robust conditions caused a small decrease in linear dynamic range and can decrease the life-time of radio-frequency source and quartz torch of the equipment. Finally, the instrument software for semiquantitative analysis was evaluated and its performance was suitable for implementation of a screening procedure for biological samples microwave-assisted acid decomposed. This method allowed quantitative results for the majority of elements evaluated. / A proposta desta tese foi avaliar criticamente a capacidade analítica de um espectrômetro de emissão óptica com plasma acoplado indutivamente (ICP OES) com configuração axial. Foi questionada a visão geral de que sistemas axiais têm aplicações somente para amostras com menor complexidade e buscou-se verificar que o desempenho dessa configuração é similar aos sistemas radiais comumente utilizados. Figuras de mérito como estabilidade, robustez, limites de detecção, faixa linear de calibração, precisão e exatidão foram monitoradas em função das condições de operação do equipamento, do sistema de introdução de amostras e da complexidade da matriz da amostra. A razão Mg II / Mg I mostrou-se um parâmetro adequado para avaliação das condições de operação do ICP OES. Planejamento fatorial possibilitou a determinação das condições robustas para diferentes sistemas de introdução de amostras e evidenciou a ineficiência do nebulizador com ranhura em V quando operado em baixa vazão do gás de nebulização. Para esse nebulizador, em oposição ao descrito na literatura, as condições robustas de operação foram obtidas em elevada potência aplicada e elevada vazão do gás de nebulização. Em condição robusta, menores limites de detecção foram obtidos e as medidas de leite em pó desnatado diluído em mistura de aminas terciárias e aço austenítico digerido em meio de água régia geraram resultados satisfatórios apesar da complexidade das matrizes. Para o trabalho com bebidas alcoólicas foi necessário utilizar concentração alcoólica semelhante às amostras nas soluções de referência para compensar efeitos de transporte devido à presença de compostos orgânicos. Entretanto, desvios maiores que 10% foram observados na recuperação de alguns elementos em amostras de vinho. O uso do método das adições de padrão ou a compatibilização de matriz pela adição de Fe nas soluções de referência não se mostraram necessários no trabalho com aço austenítico e a calibração foi feita com soluções preparadas em meio de água régia 1,2 % v v-1. Portanto, não ocorreram severos efeitos de matriz na configuração axial, o que a torna competitiva com os sistemas radiais, tendo como vantagem adicional os menores limites de detecção. Entretanto, a aplicação de condições robustas causou uma pequena diminuição na faixa linear de calibração, além de poder causar maior desgaste na fonte de rádio-freqüência e na tocha de quartzo do equipamento. Além disso, o programa disponível no equipamento para realização de análises semi-quantitativas também foi avaliado e mostrou-se adequado para procedimentos de screening de amostras biológicas decompostas em meio ácido em forno de microondas com cavidade, possibilitando a obtenção de resultados quantitativos para a maioria dos elementos avaliados.
3

Determinação espectofométrica de hipoclorito em alvejantes e cloro em águas de abastecimento empregando sistema em fluxo por multicomutação e células convencional e de longo caminho óptico

Salami, Fernanda Helena 18 February 2008 (has links)
Made available in DSpace on 2016-06-02T20:36:20Z (GMT). No. of bitstreams: 1 1931.pdf: 3271266 bytes, checksum: ac7d5d17977332c6c74ea7b27253652c (MD5) Previous issue date: 2008-02-18 / Financiadora de Estudos e Projetos / A multicommutation flow system for the spectrophotometric determination of hypochlorite in bleaching products using a cell with pathlength of 1 cm is proposed in this work. In this system, N,N-diethyl-p-phenylenediamine (DPD) reacts with hypochlorite and the product was monitored at 515 nm. The analytical curve for hypochlorite was linear in concentration range from 2.68x10-5 to 1.88x10-4 mol L-1 (2 to 14 mg L-1) with a detection limit of 6.84x10-6 mol L-1 (0.51 mg L-1). The sampling rate of 45 h-1 and a relative standard deviation of 1.4 % (n = 10), were obtained. The recovery of this analyte ranged from 97% to 102.5%. The results found for six bleaching products using the proposed multicommutated flow system agreed with those data obtained using a reference method (iodometric titration) at the 95 % confidence level. A multicommutation flow system for the spectrophotometric determination of chlorine in water samples using a cell with 100 cm of pathlength is also proposed in this work. In this system, dichloridrate orto-Tolidine (3,3-dimethyl bencidine) reacts with chlorine and the product was monitored at 438 nm. The analytical curve for hypochlorite was linear in the concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 (0.1 to 1.5 mg L-1) with a detection limit of 9.4x10-8 mol L-1 (7.0x10-3 mg L-1). The sampling rate of 45 h-1 and a relative standard deviation of 1.0 % (n = 15), were obtained. The recovery of this analyte ranged from 96.8% to 104.6%. The results found for six water samples from São Carlos city using the proposed method agreed with those data obtained using the method used by CETESB (Kit DPD colorimetric) at the 95 % confidence level. The long pathlength optic system is composed by amorphous fluorpolymeric Teflon AF2400tube with a 100 cm of length and refraction index smaller than the water one that was used as wave guide, aiming to minimize radiation losses. Finally, flow system involving multicommutation was developed to increase analytical features, decrease the reagents consumption and residual production. / A determinação espectrofotométrica de hipoclorito em alvejantes, utilizando análise por injeção em fluxo e multicomutação é proposta neste trabalho. Nesse sistema, sulfato de N,N-dietil-p-fenilenodiamina (DPD) reage com hipoclorito, sendo o produto resultante monitorado em 515 nm. O sistema proposto apresentou curva analítica linear no intervalo de concentração de hipoclorito de 2,68x10-5 a 1,88x10-4 mol L-1 (2 a 14 mg L-1) usando-se a célula de 1 cm de caminho óptico, com um limite de detecção de 6,84x10-6 mol L-1 (0,51 mg L-1), freqüência analítica de 45 determinações por hora e desvio padrão relativo de 1,4 % (n = 10). A recuperação do analito variou de 97% a 102,5%. Os resultados obtidos para hipoclorito, em seis amostras de alvejantes, de acordo com o procedimento proposto, foram concordantes com aqueles obtidos quando se empregou um método padrão (titulação iodométrica), com um nível de confiança de 95 %. Em outra etapa, foi proposta a determinação de cloro em águas de abastecimento por espectrofotometria em fluxo com longo caminho óptico (100 cm) e multicomutação. Nesse sistema, dicloridrato de orto-tolidina (3,3 -dimetilbenzidina) reage com cloro, sendo o produto resultante monitorado em 438 nm. A curva analítica foi linear no intervalo de concentração de cloro de 1,34x10-6 a 2,01x10-5 mol L-1 (0,1 a 1,5 mg L-1), com um limite de detecção de 9,4x10-8 mol L-1 (0,007 mg L-1). A freqüência analítica foi de 45 determinações por hora e desvio padrão relativo de 1,03 % (n = 15). A recuperação do analito variou de 96,8% a 104,6%. Os resultados obtidos para cloro, em seis amostras de águas de abastecimento da cidade de São Carlos-SP, de acordo com o procedimento proposto, foram concordantes com aqueles obtidos quando se empregou o método utilizado pela CETESB (DPD colorimétrico), com um nível de confiança de 95 %. O sistema de longo caminho óptico é constituído por um tubo de Teflon AF2400fluorpolímero amorfo, de um metro de comprimento, com índice de refração inferior ao da água. Esse tubo serve como guia de onda, minimizando, assim, perdas de radiação. Os sistemas propostos propiciaram melhor desempenho analítico, diminuindo o consumo de reagentes e, principalmente, a produção de resíduos.
4

Medidores de distância por triangulação a laser. / Laser triangulation rangefinders.

Stefani, Mario Antonio 20 September 1995 (has links)
Os Medidores de Distância por Triangulação a Laser são sistemas optoeletrônicos destinados à medição de pequenas distâncias ou deslocamentos, sem contato físico direto. Estes equipamentos possuem um grande campo de aplicações industriais. Este trabalho descreve as diversas configurações que este equipamento pode se apresentar, discutindo suas vantagens relativas. São estudadas também as suas partes e os componentes mais indicados. O projeto detalhado de um medidor usando sensor tipo CCD, e apresentado. Algumas aplicações industriais deste modelo são relatadas e diversos métodos e sugestões de uso são apresentadas, com base nas experiências realizadas pelo autor. / Laser Triangulation Rangefinders are non-contact, optoelectronic devices for measurement of small displacements or distances. These devices offer a broad range of industrial applications. This work explains common configurations, parts and main components, comparing their advantages. A detailed project on a CCD based Laser Rangefinder is presented. Some industrial applications for that project are related, discussing practical aspects based on authors experience. Some potential applications are also suggested.
5

Medidores de distância por triangulação a laser. / Laser triangulation rangefinders.

Mario Antonio Stefani 20 September 1995 (has links)
Os Medidores de Distância por Triangulação a Laser são sistemas optoeletrônicos destinados à medição de pequenas distâncias ou deslocamentos, sem contato físico direto. Estes equipamentos possuem um grande campo de aplicações industriais. Este trabalho descreve as diversas configurações que este equipamento pode se apresentar, discutindo suas vantagens relativas. São estudadas também as suas partes e os componentes mais indicados. O projeto detalhado de um medidor usando sensor tipo CCD, e apresentado. Algumas aplicações industriais deste modelo são relatadas e diversos métodos e sugestões de uso são apresentadas, com base nas experiências realizadas pelo autor. / Laser Triangulation Rangefinders are non-contact, optoelectronic devices for measurement of small displacements or distances. These devices offer a broad range of industrial applications. This work explains common configurations, parts and main components, comparing their advantages. A detailed project on a CCD based Laser Rangefinder is presented. Some industrial applications for that project are related, discussing practical aspects based on authors experience. Some potential applications are also suggested.

Page generated in 0.0359 seconds