Spelling suggestions: "subject:"espectofotometria"" "subject:"spectofotometria""
1 |
Desenvolvimento de métodos limpos para screening e determinação de sulfonamidas em matrizes diversasFernandes, Flávio Cesar Bedatty [UNESP] 20 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-06-20Bitstream added on 2014-06-13T20:59:14Z : No. of bitstreams: 1
fernandes_fcb_me_araiq.pdf: 1102858 bytes, checksum: 4c88e34a40933cd981ce043c3b791166 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos dois métodos ambientalmente mais amigáveis para screening e determinação de sulfonamidas em matrizes diversas. O primeiro método desenvolvido foi o de análise por injeção em fluxo (FIA) com detecção espectrofotométrica, o qual se baseia na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminobenzaldeído (p-DAB - 1,34 x 10-2 mol L-1 ou 0,2 % m/v) em meio ácido (HCl - 2,05 x 10-1 mol L-1) com adição de dodecil sulfato de sódio (SDS - 3,0 x 10-2 mol L-1), o que aumentou significativamente a sensibilidade da reação a qual produz um produto amarelo com λmáx = 465 nm. A configuração escolhida para o sistema FIA foi a de zonas coalescentes empregando um injetor comutador de três peças. Neste caso, são adicionados a reação, volumes fixos da solução contendo o analito e da solução contendo o reagente, sendo estes de 502 e 150 μL, respectivamente, transportados por uma solução carregadora de HCl 5,0 x 10-2 mol L-1 até a confluência. A faixa linear estudada variou entre 0,2 mg L-1 a 5,0 mg L-1 (0,2 - 5,0ppm). Os limites de detecção (LOD) e de quantificação (LOQ) calculados foram entre 0,040 - 0,050 mg L-1 e 0,130 - 0,160 mg L-1, respectivamente. A freqüência analítica obtida foi de 60 análises por hora. O segundo método desenvolvido foi o de espectroscopia de reflectância difusa utilizando spot test. O método é baseado na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminocinamaldeído (2,4 x 10-3 mol L-1 ou 0,042 % m/v) em meio ácido (HCl - 2,0 x 10-2 mol L-1) e SDS (3,5 x 10-2 mol L-1), sobre a superfície de um papel de filtro, produzindo um complexo colorido (λmáx = 560 nm) estável. Para a reação apenas 20 μL de cada solução foi utilizada, sendo um procedimento limpo, pois gera pouco resíduo ao meio ambiente. A faixa linear de... / In this work were developed two environmentally friendly analytical methods for screening and determination of sulfonamides in several matrices. The first method developed was flow injection analysis (FIA) using spectrophotometric determination, which is based on the reaction between sulfonamide and coupling reagent p-dimethylaminobenzaldehyde (1.34 x 10-2 mol L-1 or 0.2 % m/v) in acid medium (HCl - 2.05 x 10-1 mol L-1) with the addition of sodium dodecyl sulfate (SDS - 3.0 x 10-2 mol L-1) what significantly increased the sensitivity of the reaction which yield a yellow product with λmáx = 465 nm. Merging zone configuration employing a three-piece manual injector-commutator was chosen for system FIA. In this case, are added to the reaction, fixed volumes of solution containing the analyte and the solution containing the reagent, the latter being of 502 and 150 μL, respectively, loaded via the porter (5.0 x 10-2 mol L-1) until confluent point. The linear range was 0.2 mg L-1 a 5.0 mg L-1 (0.2 - 5.0 ppm). The limits of detection LOD) and quantification (LOQ) estimated were 0.040 - 0.050 mg L-1 and 0.130 - 0.160 mg L-1, respectively. The average sample rate of 60 determinations per hour. The second method developed was diffuse reflectance spectroscopy using spot test analysis. The method is based on the reaction between sulfonamides and coupling reagent p-dimethylaminocinnamaldeyde (2.4 x 10-3 mol L-1 or 0.042% m/v) in acid medium (HCl - 2.0 x 10-2 mol L-1) and SDS (3.5 x 10-2 mol L-1), on the surface of filter paper, yielding a stable colored product (λ = 560 nm). For the reaction only 20 μL of reagent was applied, it’s a clear procedure, yielding a little quantity of residues. The linear range was 1.0-10.0 mg L-1 (1 - 10 ppm). The limits of detection (LOD) and quantification (LOQ) estimated were 0.140 a 0.200 mg L-1 and... (Complete abstract click electronic access below)
|
2 |
Desenvolvimento de métodos limpos para screening e determinação de sulfonamidas em matrizes diversas /Fernandes, Flávio Cesar Bedatty. January 2011 (has links)
Orientador: Leonardo Pezza / Coorientador: Helena Redigolo Pezza / Banca: Homero Marques Gomes / Banca: Orlando Fatibello Filho / Resumo: Neste trabalho foram desenvolvidos dois métodos ambientalmente mais amigáveis para screening e determinação de sulfonamidas em matrizes diversas. O primeiro método desenvolvido foi o de análise por injeção em fluxo (FIA) com detecção espectrofotométrica, o qual se baseia na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminobenzaldeído (p-DAB - 1,34 x 10-2 mol L-1 ou 0,2 % m/v) em meio ácido (HCl - 2,05 x 10-1 mol L-1) com adição de dodecil sulfato de sódio (SDS - 3,0 x 10-2 mol L-1), o que aumentou significativamente a sensibilidade da reação a qual produz um produto amarelo com λmáx = 465 nm. A configuração escolhida para o sistema FIA foi a de zonas coalescentes empregando um injetor comutador de três peças. Neste caso, são adicionados a reação, volumes fixos da solução contendo o analito e da solução contendo o reagente, sendo estes de 502 e 150 μL, respectivamente, transportados por uma solução carregadora de HCl 5,0 x 10-2 mol L-1 até a confluência. A faixa linear estudada variou entre 0,2 mg L-1 a 5,0 mg L-1 (0,2 - 5,0ppm). Os limites de detecção (LOD) e de quantificação (LOQ) calculados foram entre 0,040 - 0,050 mg L-1 e 0,130 - 0,160 mg L-1, respectivamente. A freqüência analítica obtida foi de 60 análises por hora. O segundo método desenvolvido foi o de espectroscopia de reflectância difusa utilizando spot test. O método é baseado na reação entre sulfonamidas e o reagente cromogênico p-dimetilaminocinamaldeído (2,4 x 10-3 mol L-1 ou 0,042 % m/v) em meio ácido (HCl - 2,0 x 10-2 mol L-1) e SDS (3,5 x 10-2 mol L-1), sobre a superfície de um papel de filtro, produzindo um complexo colorido (λmáx = 560 nm) estável. Para a reação apenas 20 μL de cada solução foi utilizada, sendo um procedimento limpo, pois gera pouco resíduo ao meio ambiente. A faixa linear de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work were developed two environmentally friendly analytical methods for screening and determination of sulfonamides in several matrices. The first method developed was flow injection analysis (FIA) using spectrophotometric determination, which is based on the reaction between sulfonamide and coupling reagent p-dimethylaminobenzaldehyde (1.34 x 10-2 mol L-1 or 0.2 % m/v) in acid medium (HCl - 2.05 x 10-1 mol L-1) with the addition of sodium dodecyl sulfate (SDS - 3.0 x 10-2 mol L-1) what significantly increased the sensitivity of the reaction which yield a yellow product with λmáx = 465 nm. Merging zone configuration employing a three-piece manual injector-commutator was chosen for system FIA. In this case, are added to the reaction, fixed volumes of solution containing the analyte and the solution containing the reagent, the latter being of 502 and 150 μL, respectively, loaded via the porter (5.0 x 10-2 mol L-1) until confluent point. The linear range was 0.2 mg L-1 a 5.0 mg L-1 (0.2 - 5.0 ppm). The limits of detection LOD) and quantification (LOQ) estimated were 0.040 - 0.050 mg L-1 and 0.130 - 0.160 mg L-1, respectively. The average sample rate of 60 determinations per hour. The second method developed was diffuse reflectance spectroscopy using spot test analysis. The method is based on the reaction between sulfonamides and coupling reagent p-dimethylaminocinnamaldeyde (2.4 x 10-3 mol L-1 or 0.042% m/v) in acid medium (HCl - 2.0 x 10-2 mol L-1) and SDS (3.5 x 10-2 mol L-1), on the surface of filter paper, yielding a stable colored product (λ = 560 nm). For the reaction only 20 μL of reagent was applied, it's a clear procedure, yielding a little quantity of residues. The linear range was 1.0-10.0 mg L-1 (1 - 10 ppm). The limits of detection (LOD) and quantification (LOQ) estimated were 0.140 a 0.200 mg L-1 and... (Complete abstract click electronic access below) / Mestre
|
3 |
Determinação espectofométrica de hipoclorito em alvejantes e cloro em águas de abastecimento empregando sistema em fluxo por multicomutação e células convencional e de longo caminho ópticoSalami, Fernanda Helena 18 February 2008 (has links)
Made available in DSpace on 2016-06-02T20:36:20Z (GMT). No. of bitstreams: 1
1931.pdf: 3271266 bytes, checksum: ac7d5d17977332c6c74ea7b27253652c (MD5)
Previous issue date: 2008-02-18 / Financiadora de Estudos e Projetos / A multicommutation flow system for the spectrophotometric determination of hypochlorite in bleaching products using a cell with pathlength of 1 cm is proposed in this work. In this system, N,N-diethyl-p-phenylenediamine (DPD) reacts with hypochlorite and the product was monitored at 515 nm. The analytical curve for hypochlorite was linear in concentration range from 2.68x10-5 to 1.88x10-4 mol L-1 (2 to 14 mg L-1) with a detection limit of 6.84x10-6 mol L-1 (0.51 mg L-1). The sampling rate of 45 h-1 and a relative standard deviation of 1.4 % (n = 10), were obtained. The recovery of this analyte ranged from 97% to 102.5%. The results found for six bleaching products using the proposed multicommutated flow system agreed with those data obtained using a reference method (iodometric titration) at the 95 % confidence level. A multicommutation flow system for the spectrophotometric determination of chlorine in water samples using a cell with 100 cm of pathlength is also proposed in this work. In this system, dichloridrate orto-Tolidine (3,3-dimethyl bencidine) reacts with chlorine and the product was monitored at 438 nm. The analytical curve for hypochlorite was linear in the concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 (0.1 to 1.5 mg L-1) with a detection limit of 9.4x10-8 mol L-1 (7.0x10-3 mg L-1). The sampling rate of 45 h-1 and a relative standard deviation of 1.0 % (n = 15), were obtained. The recovery of this analyte ranged from 96.8% to 104.6%. The results found for six water samples from São Carlos city using the proposed method agreed with those data obtained using the method used by CETESB (Kit DPD colorimetric) at the 95 % confidence level. The long pathlength optic system is composed by amorphous fluorpolymeric Teflon AF2400tube with a 100 cm of length and refraction index smaller than the water one that was used as wave guide, aiming to minimize radiation losses. Finally, flow system involving multicommutation was developed to increase analytical features, decrease the reagents consumption and residual production. / A determinação espectrofotométrica de hipoclorito em alvejantes, utilizando análise por injeção em fluxo e multicomutação é proposta neste trabalho. Nesse sistema, sulfato de N,N-dietil-p-fenilenodiamina (DPD) reage com hipoclorito, sendo o produto resultante monitorado em 515 nm. O sistema proposto apresentou curva analítica linear no intervalo de concentração de hipoclorito de 2,68x10-5 a 1,88x10-4 mol L-1 (2 a 14 mg L-1) usando-se a célula de 1 cm de caminho óptico, com um limite de detecção de 6,84x10-6 mol L-1 (0,51 mg L-1), freqüência analítica de 45 determinações por hora e desvio padrão relativo de 1,4 % (n = 10). A recuperação do analito variou de 97% a 102,5%. Os resultados obtidos para hipoclorito, em seis amostras de alvejantes, de acordo com o procedimento proposto, foram concordantes com aqueles obtidos quando se empregou um método padrão (titulação iodométrica), com um nível de confiança de 95 %. Em outra etapa, foi proposta a determinação de cloro em águas de abastecimento por espectrofotometria em fluxo com longo caminho óptico (100 cm) e multicomutação. Nesse sistema, dicloridrato de orto-tolidina (3,3 -dimetilbenzidina) reage com cloro, sendo o produto resultante monitorado em 438 nm. A curva analítica foi linear no intervalo de concentração de cloro de 1,34x10-6 a 2,01x10-5 mol L-1 (0,1 a 1,5 mg L-1), com um limite de detecção de 9,4x10-8 mol L-1 (0,007 mg L-1). A freqüência analítica foi de 45 determinações por hora e desvio padrão relativo de 1,03 % (n = 15). A recuperação do analito variou de 96,8% a 104,6%. Os resultados obtidos para cloro, em seis amostras de águas de abastecimento da cidade de São Carlos-SP, de acordo com o procedimento proposto, foram concordantes com aqueles obtidos quando se empregou o método utilizado pela CETESB (DPD colorimétrico), com um nível de confiança de 95 %. O sistema de longo caminho óptico é constituído por um tubo de Teflon AF2400fluorpolímero amorfo, de um metro de comprimento, com índice de refração inferior ao da água. Esse tubo serve como guia de onda, minimizando, assim, perdas de radiação. Os sistemas propostos propiciaram melhor desempenho analítico, diminuindo o consumo de reagentes e, principalmente, a produção de resíduos.
|
Page generated in 0.0497 seconds