• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 167
  • 5
  • Tagged with
  • 172
  • 172
  • 66
  • 42
  • 39
  • 25
  • 23
  • 23
  • 22
  • 21
  • 21
  • 18
  • 18
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência do ácido peracético sobre a resistência flexural e rugosidade das cerâmicas do sistema Procera AllCeram

Arruda, Fernanda Zanella January 2003 (has links)
O objetivo deste trabalho foi avaliar a influência da imersão em ácido peracético sobre a resistência flexural e rugosidade das cerâmicas do sistema Procera AllCeram. Para cada ensaio foram analisados, o grupo controle e experimental cuja variável foi a imersão em ácido peracético (0,2%), por 50 minutos. A resistência flexural biaxial foi avaliada de acordo com a especificação 6872, da International Organization for Standardization (ISO), que requer um valor mínimo de 50MPa para a cerâmica de cobertura (AllCeram) e 100MPa para a cerâmica de subestrutura (Procera). Para todos os ensaios foram confeccionados 10 corpos de prova, de cada material para compor os grupos experimental (imerso em desinfetante) e controle, com dimensões de (16±0,2)mm de diâmetro por (1,6±0,1)mm de espessura para o AllCeram e, (12±0,2)mm de diâmetro e (1,2±0,2)mm de espessura para o Procera, totalizando 60 corpos de prova. A rugosidade foi avaliada com um rugosímetro utilizando o parâmetro Ra. Os valores médios de resistência flexural biaxial e o desvio padrão dos grupos controle e experimental do Procera e AllCeram foram respectivamente, (440,7±114,77)MPa, (411,6±45,02)MPa, (76,5±3,59)MPa e (86,5±15,41)MPa. Os valores médios da rugosidade e o desvio padrão dos grupos controle e experimental do Procera e AllCeram foram respectivamente: (0,090±0,014)µm, (0,086±0,009) µm, (0,022±0,004)µm e (0,0210±0,006) µm. Quando comparados com a ISO 6872, todos os corpos de prova foram aprovados quanto à resistência flexural. Quando comparados entre si, através do teste “t” de Student não houve diferença significativa entre os grupos experimental e controle de cada um dos ensaios, mostrando que o ácido peracético não interferiu significativamente nas propriedades de resistência flexural e rugosidade dos materiais. Sendo assim, pode-se prever que tal procedimento não trará prejuízos ao desempenho clínico das próteses confeccionadas com as cerâmicas do sistema Procera AllCeram quando consideradas as propriedades analisadas, podendo ser um procedimento clinicamente recomendável. Unitermos: cerâmica odontológica, resistência flexural, rugosidade, ácido peracético.
12

Avaliação da dentina de dentes decíduos submetidos à técnica de remoção parcial de tecido cariado

Dalpian, Débora Martini January 2009 (has links)
O objetivo deste estudo foi avaliar a microdureza Knoop da dentina cariada remanescente de dentes decíduos submetidos ao capeamento pulpar indireto (CPI) e restaurados com sistema adesivo autocondicionante e resina composta, associado ou não a uma base forradora de cimento de hidróxido de cálcio. Para tal, molares decíduos submetidos ao CPI e restaurados com Clearfil SE Bond – Kuraray, Japão (CSE) e resina composta Filtek Z250 – 3M Espe, EUA foram acompanhados clínica e radiograficamente até a esfoliação. Foram coletados 7 dentes do grupo onde foi aplicado o Dycal – Dentsply, EUA (DY) e 10 com CSE sobre o remanescente cariado e comparados com 10 molares decíduos hígidos com preparo cavitário in vitro de 3 a 4 mm de profundidade, e 10 molares decíduos cariados, submetidos a RPTC in vitro. As mensurações de microdureza foram realizadas, após secção e polimento, a partir da porção mais profunda da cavidade em direção à câmara pulpar nas profundidades de 10, 35, 60, 85, 110, 200μm e, a partir desta, pontos equidistantes 100μm até atingir o teto da câmara pulpar. Entre os grupos CSE e DY não houve diferença nos valores de microdureza em todas as profundidades, porém quando comparados aos Cariados, o CSE apresentou valores significativamente maiores a partir da profundidade 35μm, enquanto esse aumento só foi detectado em 200μm no DY. A partir de 700μm não ocorreu diferença nos valores de microdureza entre todos os grupos. Com base nos resultados, conclui-se que os dentes decíduos submetidos ao CPI apresentaram aumento da microdureza, independentemente do uso de base forradora de Dycal ou CSE. / The aim of this study was to evaluate remaining carious dentin microhardness from deciduous teeth submitted to Indirect Pulp Treatment (IPT) and restored with self etching primer and composite, associated or not with calcium hydroxide capping. Deciduous molars treated with IPT and restored with Clearfil SE Bond – Kuraray, Japan (CSE) and composite Filtek-Z250 – 3M ESPE, EUA were clinically and radiographically evaluated until exfoliation. Seven teeth capped with calcium hydroxide (Dycal – Dentsply, EUA – DY) and 10 with CSE were collected and compared with 10 sound deciduous molars where 3- to 4-mm deep cavities were prepared, and also with 10 carious molars were partial caries removal was conducted in vitro. Microhardness analysis was performed after sample sectioning and polishing, at 10-, 35-, 60-, 85-, 110- and 200-μm depths and later each 100μm until reaching the pulpar chamber roof. No difference was observed in microhardness values between CSE and DY groups in all depths analyzed, otherwise when compared with carious group, CSE presented significantly higher values from 35μm depth, while this increase was observed only with 200μm in the DY group. From 700μm depth no difference was observed in the microhardness values between all groups in study. It can be concluded that deciduous teeth submitted to IPT presented a hardness increase, independently of the capping material type, Dycal or CSE.
13

Avaliação da dentina de dentes decíduos submetidos à técnica de remoção parcial de tecido cariado

Dalpian, Débora Martini January 2009 (has links)
O objetivo deste estudo foi avaliar a microdureza Knoop da dentina cariada remanescente de dentes decíduos submetidos ao capeamento pulpar indireto (CPI) e restaurados com sistema adesivo autocondicionante e resina composta, associado ou não a uma base forradora de cimento de hidróxido de cálcio. Para tal, molares decíduos submetidos ao CPI e restaurados com Clearfil SE Bond – Kuraray, Japão (CSE) e resina composta Filtek Z250 – 3M Espe, EUA foram acompanhados clínica e radiograficamente até a esfoliação. Foram coletados 7 dentes do grupo onde foi aplicado o Dycal – Dentsply, EUA (DY) e 10 com CSE sobre o remanescente cariado e comparados com 10 molares decíduos hígidos com preparo cavitário in vitro de 3 a 4 mm de profundidade, e 10 molares decíduos cariados, submetidos a RPTC in vitro. As mensurações de microdureza foram realizadas, após secção e polimento, a partir da porção mais profunda da cavidade em direção à câmara pulpar nas profundidades de 10, 35, 60, 85, 110, 200μm e, a partir desta, pontos equidistantes 100μm até atingir o teto da câmara pulpar. Entre os grupos CSE e DY não houve diferença nos valores de microdureza em todas as profundidades, porém quando comparados aos Cariados, o CSE apresentou valores significativamente maiores a partir da profundidade 35μm, enquanto esse aumento só foi detectado em 200μm no DY. A partir de 700μm não ocorreu diferença nos valores de microdureza entre todos os grupos. Com base nos resultados, conclui-se que os dentes decíduos submetidos ao CPI apresentaram aumento da microdureza, independentemente do uso de base forradora de Dycal ou CSE. / The aim of this study was to evaluate remaining carious dentin microhardness from deciduous teeth submitted to Indirect Pulp Treatment (IPT) and restored with self etching primer and composite, associated or not with calcium hydroxide capping. Deciduous molars treated with IPT and restored with Clearfil SE Bond – Kuraray, Japan (CSE) and composite Filtek-Z250 – 3M ESPE, EUA were clinically and radiographically evaluated until exfoliation. Seven teeth capped with calcium hydroxide (Dycal – Dentsply, EUA – DY) and 10 with CSE were collected and compared with 10 sound deciduous molars where 3- to 4-mm deep cavities were prepared, and also with 10 carious molars were partial caries removal was conducted in vitro. Microhardness analysis was performed after sample sectioning and polishing, at 10-, 35-, 60-, 85-, 110- and 200-μm depths and later each 100μm until reaching the pulpar chamber roof. No difference was observed in microhardness values between CSE and DY groups in all depths analyzed, otherwise when compared with carious group, CSE presented significantly higher values from 35μm depth, while this increase was observed only with 200μm in the DY group. From 700μm depth no difference was observed in the microhardness values between all groups in study. It can be concluded that deciduous teeth submitted to IPT presented a hardness increase, independently of the capping material type, Dycal or CSE.
14

Avaliação da dentina de dentes decíduos submetidos à técnica de remoção parcial de tecido cariado

Dalpian, Débora Martini January 2009 (has links)
O objetivo deste estudo foi avaliar a microdureza Knoop da dentina cariada remanescente de dentes decíduos submetidos ao capeamento pulpar indireto (CPI) e restaurados com sistema adesivo autocondicionante e resina composta, associado ou não a uma base forradora de cimento de hidróxido de cálcio. Para tal, molares decíduos submetidos ao CPI e restaurados com Clearfil SE Bond – Kuraray, Japão (CSE) e resina composta Filtek Z250 – 3M Espe, EUA foram acompanhados clínica e radiograficamente até a esfoliação. Foram coletados 7 dentes do grupo onde foi aplicado o Dycal – Dentsply, EUA (DY) e 10 com CSE sobre o remanescente cariado e comparados com 10 molares decíduos hígidos com preparo cavitário in vitro de 3 a 4 mm de profundidade, e 10 molares decíduos cariados, submetidos a RPTC in vitro. As mensurações de microdureza foram realizadas, após secção e polimento, a partir da porção mais profunda da cavidade em direção à câmara pulpar nas profundidades de 10, 35, 60, 85, 110, 200μm e, a partir desta, pontos equidistantes 100μm até atingir o teto da câmara pulpar. Entre os grupos CSE e DY não houve diferença nos valores de microdureza em todas as profundidades, porém quando comparados aos Cariados, o CSE apresentou valores significativamente maiores a partir da profundidade 35μm, enquanto esse aumento só foi detectado em 200μm no DY. A partir de 700μm não ocorreu diferença nos valores de microdureza entre todos os grupos. Com base nos resultados, conclui-se que os dentes decíduos submetidos ao CPI apresentaram aumento da microdureza, independentemente do uso de base forradora de Dycal ou CSE. / The aim of this study was to evaluate remaining carious dentin microhardness from deciduous teeth submitted to Indirect Pulp Treatment (IPT) and restored with self etching primer and composite, associated or not with calcium hydroxide capping. Deciduous molars treated with IPT and restored with Clearfil SE Bond – Kuraray, Japan (CSE) and composite Filtek-Z250 – 3M ESPE, EUA were clinically and radiographically evaluated until exfoliation. Seven teeth capped with calcium hydroxide (Dycal – Dentsply, EUA – DY) and 10 with CSE were collected and compared with 10 sound deciduous molars where 3- to 4-mm deep cavities were prepared, and also with 10 carious molars were partial caries removal was conducted in vitro. Microhardness analysis was performed after sample sectioning and polishing, at 10-, 35-, 60-, 85-, 110- and 200-μm depths and later each 100μm until reaching the pulpar chamber roof. No difference was observed in microhardness values between CSE and DY groups in all depths analyzed, otherwise when compared with carious group, CSE presented significantly higher values from 35μm depth, while this increase was observed only with 200μm in the DY group. From 700μm depth no difference was observed in the microhardness values between all groups in study. It can be concluded that deciduous teeth submitted to IPT presented a hardness increase, independently of the capping material type, Dycal or CSE.
15

Conventional, microfilled and hybrid composite resins laboratory and clinical evaluations /

Dijken, Jan W. V. van. January 1987 (has links)
Thesis (doctoral)--Umeå Universitet, 1987. / Added t.p. with thesis statement inserted. Includes bibliographical references.
16

Conventional, microfilled and hybrid composite resins laboratory and clinical evaluations /

Dijken, Jan W. V. van. January 1987 (has links)
Thesis (doctoral)--Umeå Universitet, 1987. / Added t.p. with thesis statement inserted. Includes bibliographical references.
17

Grau de conversão, temperatura de transição vítrea, microdureza e resistência ao impacto de uma resina acrílica quimicamente ativada submetida a diferentes condições de polimerização

Machado, Cintia de Vasconcellos January 2005 (has links)
O objetivo deste estudo foi avaliar a influência de diferentes condições de polimerização sobre: microdureza Knoop, resistência ao impacto, grau de conversão e temperatura de transição vítrea (Tg) de uma resina acrílica quimicamente ativada (Jet - Artigos Odontológicos Clássico Ltda.). O material foi polimerizado de acordo com as seguintes condições: grupo 1, as amostras foram polimerizadas em contato com o ar, durante 1h, sob temperatura e pressão ambiente; grupo 2, após a polimerização da resina em contato com o ar, durante 1h, sob temperatura e pressão ambiente, a mesma foi submetida a um ciclo adicional de aquecimento em forno de microondas, durante 3 min, a 500W; grupo 3, as amostras foram polimerizadas em água, sob pressão de 20 psi, em uma temperatura de 50°C, durante 15 minutos. Para o ensaio de microdureza Knoop, foram confeccionados sete corpos-de-prova, para cada um dos três grupos experimentais. O corpo-de-prova consistiu de uma placa de resina acrílica quimicamente ativada, com grampos, simulando aparelhos ortodônticos removíveis. Dos sete corpos-de-prova, de cada grupo, dois também foram utilizados para a determinação do grau de conversão e Tg, através da Calorimetria Exploratória Diferencial (DSC). Para o ensaio de resistência ao impacto, foram confeccionados 12 corpos-de-prova para cada grupo, com dimensões de 64,00x10,00x3,20mm. Os resultados mostraram diferenças entre os grupos, através da ANOVA e do teste de Tukey (p ≤ 0,01), apresentando maiores valores de microdureza para o grupo 3, seguido dos grupos 2 e 1. Para o ensaio de resistência ao impacto, os valores obtidos para as amostras do grupo 3 foram superiores aos demais grupos, não havendo diferença estatística entre os grupos 1 e 2 O grau de conversão e Tg foram avaliados de forma descritiva, apresentando um padrão de comportamento coerente com as demais propriedades, ou seja, o grupo 3 apresentou valores mais altos de grau de conversão e Tg, seguido pelos grupos 2 e 1. Os resultados deste trabalho indicam que o melhor comportamento clínico poderá ser esperado do grupo submetido à polimerização em água a 50°C, sob pressão de 20 psi (grupo 3), seguido do grupo 2 (com ciclo adicional em microondas) e, por fim, pelo grupo 1 (polimerizado ao ar).
18

Grau de conversão, temperatura de transição vítrea, microdureza e resistência ao impacto de uma resina acrílica quimicamente ativada submetida a diferentes condições de polimerização

Machado, Cintia de Vasconcellos January 2005 (has links)
O objetivo deste estudo foi avaliar a influência de diferentes condições de polimerização sobre: microdureza Knoop, resistência ao impacto, grau de conversão e temperatura de transição vítrea (Tg) de uma resina acrílica quimicamente ativada (Jet - Artigos Odontológicos Clássico Ltda.). O material foi polimerizado de acordo com as seguintes condições: grupo 1, as amostras foram polimerizadas em contato com o ar, durante 1h, sob temperatura e pressão ambiente; grupo 2, após a polimerização da resina em contato com o ar, durante 1h, sob temperatura e pressão ambiente, a mesma foi submetida a um ciclo adicional de aquecimento em forno de microondas, durante 3 min, a 500W; grupo 3, as amostras foram polimerizadas em água, sob pressão de 20 psi, em uma temperatura de 50°C, durante 15 minutos. Para o ensaio de microdureza Knoop, foram confeccionados sete corpos-de-prova, para cada um dos três grupos experimentais. O corpo-de-prova consistiu de uma placa de resina acrílica quimicamente ativada, com grampos, simulando aparelhos ortodônticos removíveis. Dos sete corpos-de-prova, de cada grupo, dois também foram utilizados para a determinação do grau de conversão e Tg, através da Calorimetria Exploratória Diferencial (DSC). Para o ensaio de resistência ao impacto, foram confeccionados 12 corpos-de-prova para cada grupo, com dimensões de 64,00x10,00x3,20mm. Os resultados mostraram diferenças entre os grupos, através da ANOVA e do teste de Tukey (p ≤ 0,01), apresentando maiores valores de microdureza para o grupo 3, seguido dos grupos 2 e 1. Para o ensaio de resistência ao impacto, os valores obtidos para as amostras do grupo 3 foram superiores aos demais grupos, não havendo diferença estatística entre os grupos 1 e 2 O grau de conversão e Tg foram avaliados de forma descritiva, apresentando um padrão de comportamento coerente com as demais propriedades, ou seja, o grupo 3 apresentou valores mais altos de grau de conversão e Tg, seguido pelos grupos 2 e 1. Os resultados deste trabalho indicam que o melhor comportamento clínico poderá ser esperado do grupo submetido à polimerização em água a 50°C, sob pressão de 20 psi (grupo 3), seguido do grupo 2 (com ciclo adicional em microondas) e, por fim, pelo grupo 1 (polimerizado ao ar).
19

Grau de conversão, temperatura de transição vítrea, microdureza e resistência ao impacto de uma resina acrílica quimicamente ativada submetida a diferentes condições de polimerização

Machado, Cintia de Vasconcellos January 2005 (has links)
O objetivo deste estudo foi avaliar a influência de diferentes condições de polimerização sobre: microdureza Knoop, resistência ao impacto, grau de conversão e temperatura de transição vítrea (Tg) de uma resina acrílica quimicamente ativada (Jet - Artigos Odontológicos Clássico Ltda.). O material foi polimerizado de acordo com as seguintes condições: grupo 1, as amostras foram polimerizadas em contato com o ar, durante 1h, sob temperatura e pressão ambiente; grupo 2, após a polimerização da resina em contato com o ar, durante 1h, sob temperatura e pressão ambiente, a mesma foi submetida a um ciclo adicional de aquecimento em forno de microondas, durante 3 min, a 500W; grupo 3, as amostras foram polimerizadas em água, sob pressão de 20 psi, em uma temperatura de 50°C, durante 15 minutos. Para o ensaio de microdureza Knoop, foram confeccionados sete corpos-de-prova, para cada um dos três grupos experimentais. O corpo-de-prova consistiu de uma placa de resina acrílica quimicamente ativada, com grampos, simulando aparelhos ortodônticos removíveis. Dos sete corpos-de-prova, de cada grupo, dois também foram utilizados para a determinação do grau de conversão e Tg, através da Calorimetria Exploratória Diferencial (DSC). Para o ensaio de resistência ao impacto, foram confeccionados 12 corpos-de-prova para cada grupo, com dimensões de 64,00x10,00x3,20mm. Os resultados mostraram diferenças entre os grupos, através da ANOVA e do teste de Tukey (p ≤ 0,01), apresentando maiores valores de microdureza para o grupo 3, seguido dos grupos 2 e 1. Para o ensaio de resistência ao impacto, os valores obtidos para as amostras do grupo 3 foram superiores aos demais grupos, não havendo diferença estatística entre os grupos 1 e 2 O grau de conversão e Tg foram avaliados de forma descritiva, apresentando um padrão de comportamento coerente com as demais propriedades, ou seja, o grupo 3 apresentou valores mais altos de grau de conversão e Tg, seguido pelos grupos 2 e 1. Os resultados deste trabalho indicam que o melhor comportamento clínico poderá ser esperado do grupo submetido à polimerização em água a 50°C, sob pressão de 20 psi (grupo 3), seguido do grupo 2 (com ciclo adicional em microondas) e, por fim, pelo grupo 1 (polimerizado ao ar).
20

Avaliação da resistencia à microtração de cimentos resinosos autoadesivo e convencional

DA-RÉ, Eduardo Luiz 12 April 2016 (has links)
Objetivo: avaliar a resistência de união de dois cimentos resinosos, convencional e autoadesivo de acordo com os protocolos operacionais requeridos para esses cimentos, quando da cimentação de restaurações cerâmicas e ceroméricas, trazendo elementos para propiciar melhor compreensão da interação adesiva em procedimentos de cimentação com as referidas categorias de cimentos resinosos. Material e método: neste trabalho 20 dentes humanos cedidos pelo banco de dentes da UNIFAL foram preparados e, após serem divididos em dois grupos, neles foram cimentados cilindros de cerâmica ou de cerômero utilizando-se dois tipos de cimento resinoso (autoadesivo e convencional). Os dentes preparados foram cortados verticalmente nos sentidos vestibular-lingual e mesio-distal, obtendo-se “palitos” de cerca de 8 mm de altura e de base quadrangular que foram submetidos a teste de tração, avaliando-se a força necessária para a fratura. Os valores obtidos foram submetidos a análise estatística empregando-se o teste de análise de variância (ANOVA) e o teste de Tukey. Resultados: as forças mínima e máxima necessárias ao rompimento do cimento convencional são superiores às mesmas requeridas para o rompimento da união promovida pelo cimento autoadesivo, bem como as medianas e as médias aritméticas, independente do material restaurador empregado. O teste de Tukey demonstrou que as diferenças entre os cimentos empregados são estatisticamente significantes, independente do material restaurador. Conclusão: a diferença dos valores de resistência à tração entre os materiais de cimentação testados foi estatisticamente significante; o material utilizado para a confecção dos corpos de prova não influenciou nos valores de resistência a tração, não existindo diferenças significantes estatisticamente. / Purpose: the aim of this study was to evaluate the microtensile bond strength of two resin-based cements, conventional and self-adhesive, according to required operating protocols, when luting ceramic and indirect composite restorations. Materials and methods: 20 human molars donated by UNIFAL teeth bank were prepared and, after being divided into two groups, ceramic or composite cylinders were luted to them with two resin-based cements (conventional and self-adhesive). Prepared teeth were sectioned vertically in both buccal-lingual and mesio-distal directions, to obtain 8 mm high, square-shaped “sticks” that were subject to microtensile bond strength test, the necessary force to tracture them was evaluated. Results were subject to two-way ANOVA and Tuckey test. Results: minimum and maximum forces to disrupt conventional cement were greater than the ones required for self-adhesive cement, as well as mean bond strength, regardless the restorative material. Tukey test showed that diferences were statistically significant, regardless the restorative material. Conclusion: the difference between microtensile bond strength values of resin cements tested was statistically significant; the restorative materials did not influence microtensile bond strength values, with no statistically significant differences.

Page generated in 0.0629 seconds