• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eddy current detection of magnetic and non-magnetic metallic edges beneath continuous plate

Watson, Joseph Conrad January 2002 (has links)
No description available.
2

Développement d’un microdispositif magnétique pour le contrôle et la détection de complexes immunologiques à base de nanoparticules magnétiques / Development of a magnetic microdevice for the control and detection of immunoassay complexes based on magnetic nanoparticles

Lefebvre, Olivier 10 December 2018 (has links)
L’objectif de cette thèse est la fabrication d’un microdispositif magnétique pour la détection et la manipulation d’éléments biologiques à base de nanoparticules magnétiques en conditions microfluidiques. Il a pour but d’intégrer des fonctions de base de contrôle et détection magnétique, pour atteindre des mesures spécifiques, stables, rapides et reproductibles. En effet, la technique d’immunodosage couplée à des nanoparticules magnétiques, bien connue dans la littérature, nécessite un contrôle du déplacement de ces dernières pour les fonctionnaliser efficacement et créer un complexe biologique encapsulant une molécule cible (biomarqueur). Dans notre cas une molécule modèle pour le domaine de la biodéfense a été utilisée : l’ovalbumine. Pour contrôler le champ magnétique nécessaire pour la capture des complexes magnétiques, nous avons opté pour l’utilisation de microbobines intégrées aux dispositifs fluidiques et comparé cette technique originale avec d’autres plus conventionnelles. Pour détecter un complexe biologique, la fluorescence est largement utilisée en biologie, mais cette technique ne permet pas une intégration complète pour un dispositif autonome. Dans cette optique, nous proposons la détection des complexes à base de nanoparticules magnétiques en relevant la variation de l’inductance d’un microcircuit magnétique refermant une chambre microfluidique contenant ces complexes immunologiques. Le dimensionnement des microbobines de contrôle par simulation a permis de déterminer les paramètres permettant d’obtenir le champ magnétique le plus adapté au contrôle des complexes biologiques. Dans le cas des microbobines utilisées pour la détection, des branches magnétiques micrométriques ont été insérées autour des microbobines pour créer un circuit de détection magnétique encore plus sensible. La réalisation de ces dispositifs a impliqué l’intégration de matériaux et de structures de nature fortement hétérogène, et leur assemblage a nécessité de résoudre de nombreux verrous technologiques. L’enjeu a été de déterminer l’ensemble des étapes successives et nécessaires pour un procédé de microfabrication fiable et reproductible. Pour montrer l’intérêt des dispositifs de capture des nanoparticules magnétiques, des tests immunologiques ont été réalisés tout d’abord en microtubes pour les comparer à ceux réalisés dans un circuit fluidique à l’aide d’aimant externe puis de microbobines intégrées. Dans ce dernier cas, une optimisation considérable a été validée en termes de réduction de temps d’incubation, de reproductibilité des mesures et de limites de détection équivalentes à l’état de l’art pour l’ovalbumine. Pour le dispositif de détection magnétique, des premières expériences de caractérisation électrique ainsi que des études en concentration de nanoparticules magnétiques ont été réalisées et comparées aux résultats obtenus par simulation. Pour la preuve de concept, un démonstrateur de détection de complexes magnétiques a été également finalisé validant la possibilité d’intégration du microcircuit magnétique dans un dispositif fluidique. Il a validé également l’obtention d’une gamme de sensibilité remarquable corrélée à la présence des complexes magnétiques. Ses caractéristiques ont été confrontées à celles obtenues par les simulations et discutées en tenant compte de toutes les étapes critiques du procédé de microfabrication. / RésuméThe objective of this thesis is the fabrication of a magnetic microdevice for the detection and manipulation of biological elements based on magnetic nanoparticles under microfluidic conditions. It aims to integrate basic functions of control and magnetic detection, to achieve specific, stable, fast and reproducible measurements. Indeed, the immunoassay technique coupled to magnetic nanoparticles, well known in the literature, requires a control of the displacement of magnetic nanoparticles to effectively functionalize them and create a biological complex to encapsulate a target molecule (biomarker). In our case, a model molecule for the field of biodefense was used: ovalbumin. To control the magnetic field which is necessary for the capture of magnetic complexes, we opted for the use of microcoils integrated in the fluidic devices and compared this original technique with other more conventional ones. To detect a biological complex, fluorescence is widely used in biology, but this technique does not allow a complete integration for an autonomous device. In this context, we propose the detection of complexes based on magnetic nanoparticles by observing the variation of the inductance of a magnetic microcircuit closing a microfluidic chamber containing these immunological complexes. The design of the control microcoils by simulation made it possible to determine the parameters allowing to obtain the most adapted magnetic field to the control of the biological complexes. In the case of microcoils used for detection, micrometric magnetic branches were inserted around the microcoils to create an even more sensitive magnetic sensing circuit. The realization of these devices involved the integration of materials and structures of highly heterogeneous nature, and their assembly has required to solve many technological locks. The challenge was to determine all the successive and necessary steps for a reliable and reproducible microfabrication process. To show the interest of magnetic nanoparticle capture devices, immunoassays were first performed in microtubes to compare with those made in a fluid circuit using external magnet and integrated microcoils. In the latter case, considerable optimization has been validated in terms of reduction of incubation time, reproducibility of measurements and detection limits equivalent to the state of the art for ovalbumin. For the magnetic detection device, first experiments of electrical characterization as well as concentration studies of magnetic nanoparticles were carried out and compared to the results obtained by simulation. For the proof of concept, a demonstrator of detection of magnetic complexes was also finalized validating the possibility of integration of the magnetic microcircuit in a fluidic device. It has also validated obtaining a remarkable range of sensitivity correlated with the presence of magnetic complexes. Its characteristics were compared to those obtained by the simulations and discussed taking into account all the critical steps of the microfabrication process.
3

Electromagnetic microsystem for the detection of magnetic nanoparticles in a microfluidic structure for immunoassays / Système électromagnétique de détection de nanoparticules magnétiques dans une structure microfluidique pour l'immunodétection

Rabehi, Amine 30 January 2018 (has links)
La détection et quantification d’agent biologique occupe une place prépondérante dans la prévention et la détection des dangers possibles pour la santé publique (épidémie ou pandémie), l’environnement ainsi que d’autres risques contextuelles (bioterrorisme, armes biologique ou chimiques…etc.). Par conséquent, le développement d’un système portable et à moindre coût permettant de détecter ces dangers constitue l’axe de recherche pluridisciplinaire de la collaboration entre différents laboratoires de l’UPMC (Paris 6) et « RWTH university » à Aachen en Allemagne. Dans ce projet, nous avons étudié les aspects pluridisciplinaires d’un microsystème (LoC) électromagnétique de détection immunologique basé sur l’utilisation de nanoparticules magnétiques (MNP). En raison de leur extractabilité et de leur triabilité, les MNP sont adaptées à l'examen d'échantillons biologiques, servant de marqueurs pour des réactions biochimiques. La plupart des techniques classiques de détection existantes sont basées sur des méthodes colorimétrique, fluorescence ou électrochimique qui souffrent en majorité de problème de temps d’analyse et de sensibilité. A cet égard, Les méthodes d’immuno-détection magnétiques constituent une alternative prometteuse. Cette détection est effectuée à l’aide des MNP qui sont spécifiquement bio-fonctionnalisés en surface afin d’être liée à la cible (virus, anticorps…etc). La nouvelle méthode magnétique de mélange de fréquence permet la détection et la quantification de ces MNP avec une grande dynamique. Dans cette thèse, l’effort est dirigé vers la miniaturisation de ce système. Pour ce faire, nous avons développé un ensemble d’outils analytiques et de simulations multiphysiques afin d’optimiser les dimensions des parties électromagnétique (bobines planaires) et microfluidiques. Par la suite, des prototypes de cette structure de détection à partir de bobines en circuits imprimés et de réservoirs microfluidiques en PDMS sont dimensionnés et réalisés. Les performances de ces prototypes ont été évaluées en termes de limite de détection de MNP, linéarité et plage dynamique. En outre, ces prototypes ont permis de valider les outils de dimensionnement réalisés. Une limite de détection de nanoparticules magnétiques de 15ng/mL a été mesurée avec un volume d'échantillon de 14 μL correspondant à une goutte de sang. Finalement, la validation du système quant à l’immuno-détection est abordée avec un état de l’art et le développement d’une procédure de fonctionnalisation biochimique de surface ainsi que des premiers tests pour sa validation. / The detection and quantification of a biological agent or entity has become paramount to anticipate a possible health threat (epidemic or pandemic), environmental threat or to combat other contextual threats (bioterrorism, chemical and biological weapons, drugs). Consequently, developing a portable cost effective device that could detect and quantify such threats is the research focus of the joint multidisciplinary project between UPMC (Paris 6) laboratories and RWTH university in Aachen, Germany. In the framework of this project, we have studied the multidisciplinary aspects of an electromagnetic microsystem for immunologic detection based on magnetic nanoparticles (MNP) in a microfluidic lab-on-chip (LoC). Because of their extractability and sortability, magnetic nanoparticles are adapted for examination of biological samples, serving as markers for biochemical reactions. So far, the final detection step is mostly achieved by well-known immunochemical or fluorescence-based techniques which are time consuming and have limited sensitivity. Therefore, magnetic immunoassays detecting the analyte by means of magnetic markers constitute a promising alternative. MNP covered with biocompatible surface coating can be specifically bound to analytes, cells, viruses or bacteria. They can also be used for separation and concentration enhancement. The novel frequency mixing magnetic detection method allows quantifying magnetic nanoparticles with a very large dynamic measurement range. In this thesis, emphasis is put on the miniaturized implementation of this detection scheme. Following the development of analytical and multiphysics simulations tools for optimization of both excitation frequencies and detection planar coils, first multilayered printed circuit board prototypes integrating all three different coils along with an adapted microfluidic chip has been designed and realized. These prototypes have been tested and characterized with respect to their performance for limit of detection (LOD) of MNP, linear response and validation of theoretical concepts. Using the frequency mixing magnetic detection technique, a LOD of 15ng/mL for 20 nm core sized MNP has been achieved with a sample volume of 14 μL corresponding to a drop of blood. Preliminary works for biosensing have also been achieved with a state of the art of surface functionalization and a developed proposed biochemical immobilization procedure and preliminary tests of its validation.

Page generated in 0.0881 seconds