• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 11
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 32
  • 30
  • 15
  • 15
  • 14
  • 12
  • 12
  • 11
  • 9
  • 9
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo prospectivo da utilização do sistema de placas e parafusos 2.0-mm locking comparado com sistemas convencionais no tratamento de fraturas mandibulares / A prospective study of the use of 2.0-mm locking system plates compared with standard systems in the treatment of mandibular fractures

Rubens Camino Junior 29 September 2016 (has links)
Um sistema mais adequado de fixação interna no tratamento de fraturas mandibulares é essencial para um bom resultado. Foi realizado um estudo comparativo da utilização do sistema de fixação 2.0-mm locking com sistemas convencionais no tratamento de fraturas mandibulares. Para este estudo, 87 pacientes consecutivos com 134 fraturas mandibulares foram divididos aleatoriamente para receber placas 2.0-mm locking (n = 45) ou convencionais 2.0-mm ou 2.4-mm (n = 42) e tiveram um seguimento mínimo de 6 meses. Foram obtidos dados pessoais, presença de doenças sistêmicas, abuso de substâncias, etiologia, politraumatismo e as localizações. As fraturas foram classificadas com base no grau de deslocamento e de complexidade. Foi mensurada a amplitude da abertura bucal. Análises estatísticas foram feitas na comparação entre grupos (p<= 0,050). Houve maior faixa etária (p = 0,010) e mais distúrbios gerais (p< 0,001) no Grupo Locking. Houve maior gravidade das fraturas (p= 0,004) no Grupo Convencional. Houve diferença significante para a localização das fraturas (p = 0,009), com mais casos na região de corpo no Grupo Locking. Houve aumento progressivo dos valores da abertura bucal, com diferença significante em ambos os grupos (p<= 0,050), sendo que o convencional apresentou melhor recuperação (47,2 ± 8,9 mm). Um caso de complicação pós-operatória maior ocorreu no Grupo Locking (2,2%) e três casos no Grupo Convencional (7,1%). Foi observado que o sistema 2.0-mm locking mostrou melhores resultados clínicos, pois ocorreu apenas um caso de complicação maior, porém o grupo convencional mostrou recuperação mais rápida da abertura bucal e, que também foi constatado que o sistema 2.0-mm locking foi efetivo no tratamento de fraturas desfavoráveis que necessitariam do sistema 2.4-mm convencional. / A more adequate system of internal fixation in the treatment of mandibular fractures is essential for a good result. A comparative study of the use of the 2.0-mm locking fixation system with conventional systems in the treatment of mandibular fractures was performed. For this study, 87 consecutive patients with 134 mandibular fractures were randomized to receive 2.0-mm locking plates (n = 45) or conventional 2.0-mm or 2.4-mm plates (n = 42) and had a minimum follow-up of 6 months. Fractures were classified based on the degree of displacement and complexity. The amplitude of mouth opening was measured. Statistical analyses were performed to compare groups (p <= 0.050). There were older age (p = 0.010) and more substance abuse (p = 0.001) in the Locking group. There was more complex fractures (p = 0.017) and teeth in the fracture line (p = 0.044) in the conventional group. There was a significant difference for the location of fractures (p = 0.009), with more cases in the body region in the Locking group. There was a progressive increase in the values of mouth opening, with a significant difference in both groups (p <= 0.050), whereas the conventional group showed better recovery (47.2 ± 8.9 mm). A case of major postoperative complication occurred in the Locking Group (2.2%) and three cases in the conventional group (7.1%). The 2.0-mm locking system showed better clinical outcomes because there was only one case of major complications and was effective in the treatment of unfavorable fractures that would require the conventional system 2.4-mm but the group treated with conventional systems showed faster recovery of mouth opening.
42

Efeitos do bloqueador de canais de cálcio amlodipina na reparação óssea em defeito cirúrgico no ramo mandibular de ratos / Effects of the calcium channel blocker amlodipine on bone healing of a surgical defect in the mandibular ramus of rats

Rogerio Bonfante Moraes 29 September 2009 (has links)
Os anti-hipertensivos bloqueadores de canais de cálcio, por interferirem no transporte de cálcio através das membranas celulares, podem afetar muitos processos metabólicos, incluindo o metabolismo ósseo. O objetivo deste estudo foi avaliar, de forma radiográfica, histológica e bioquímica, os efeitos do bloqueador de canais de cálcio amlodipina no processo de reparo de um defeito ósseo, simulando fratura, no ramo mandibular de ratos. Foram utilizados 50 ratos machos Wistar, que foram submetidos ao mesmo procedimento cirúrgico unilateral simulando fratura mandibular, e distribuídos em dois grupos de 25 animais: grupo experimental, que receberam amlodipina, via oral, na dosagem de 0,04 mg / rato / dia, iniciando 12 dias antes do procedimento e continuando até o sacrifício; grupo controle, que permaneceu não tratado. Os animais foram sacrificados nos períodos de 1, 7, 14, 30 e 90 dias pós-operatórios. Foram realizados testes bioquímicos de fosfatase alcalina e cálcio séricos. Exame radiográfico foi obtido para mensuração da área radiolúcida do defeito ósseo. O estudo histológico compreendeu a análise descritiva do processo de reparo ósseo e a avaliação histomorfométrica da quantidade de osso neoformado. Os valores numéricos foram submetidos a análises estatísticas. A análise radiográfica demonstrou maior área radiolúcida no interior do defeito ósseo para o grupo experimental, nos períodos de 14 (p=0,016), 30 (p=0,009) e 90 (p=0,028) dias. Na análise histológica não se observaram atrasos no processo de reparo ósseo para ambos os grupos. Porém, na análise histomorfométrica, o grupo da amlodipina apresentou redução significante do volume de osso neoformado nos períodos de 7 e 14 dias (p=0,049), não havendo diferenças significativas no período de 30 dias. Houve redução significante nos níveis de fosfatase alcalina para o grupo da amlodipina nos períodos iniciais (p=0,049). Não houve alterações para os níveis de cálcio sérico. Concluiu-se que o uso crônico da amlodipina prejudicou a neoformação óssea no processo de reparo do defeito cirúrgico no ramo mandibular de ratos, porém não impediu a consolidação da fratura. / Antihypertensive, calcium channel blockers, which interfere on calcium transport across the cell membrane, may affect many metabolic processes, including bone metabolism. The aim of this study was to evaluate by radiographic, histologic and biochemical analyses the effects of calcium channel blocker amlodipine on bone healing of a defect simulating a fracture in mandibular ramus of rats. Fifty male Wistar rats were used, and submitted to the same unilateral surgical procedure simulating a mandibular fracture, distributed into two groups of 25 animals: experimental group, which received oral doses of 0.04 mg / rat / day starting 12 days before of procedure and continuing until sacrifice; control group, which remained untreated. Animals were sacrificed at 1, 7, 14, 30 and 90 days postoperatively. Blood biochemical tests of alkaline phosphatase and serum calcium were made. Radiographic examination was obtained in order to mensurate the radiolucent area of bone defect. Histological study comprised descriptive analysis of bone healing and histomorphometric analysis of the amount of newly formed bone. Numerical values were submitted to statistical analyses. Radiographic analysis showed larger radiolucent area into bone defect to the experimental group at the periods of 14 (p=0.016), 30 (p=0.009) and 90 (p=0.028) days. In the histological analysis there was no delay in the bone repair stages in both groups. However, in the histomorphometric analysis, the experimental group presented significative lowering of newly formed bone volume at 7 and 14 days periods (p=0.049), with no significant differences at 30 days period. There was significative decrease of alkaline phosphatase levels in experimental group in the initial periods (p=0.049). There was no change in the serum calcium levels. It was concluded that chronic use of amlodipine compromised bone neoformation in the repairing process of surgical defect in the mandibular ramus of rats, but no precluded occurrence of fracture consolidation.
43

Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio / Fractographic and mechanical analysis of two brands of titanium plates in simulated body fractures of aluminum hemimandibles

Moura, Andrezza Lauria de, 1982- 06 April 2013 (has links)
Orientadores: Marcelo Marotta Araújo, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5) Previous issue date: 2013 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar / Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
44

Analyse von Zahnverletzungen durch intermaxilläre Fixierungssysteme mit IMF-Schrauben im Rahmen der Kieferbruchbehandlung

Shehadeh, Muhammad 27 November 2020 (has links)
Einführung: Zu den Immobilisationsmethoden bei Kieferfrakturen gehören die selbstbohrenden Schrauben (IMF-Schrauben). Diese könnten – wie jeder chirurgische Eingriff – zu Komplikationen führen. Eine dieser Komplikationen ist die Zahnwurzelverletzung. In dieser retrospektiven Studie werden die Patienten, bei denen im Rahmen der Versorgung von Unterkieferfrakturen in der Klinik der MKG-Uniklinik-Dresden im Zeitraum von 2011 bis 2015 IMF-Schrauben eingesetzt wurden, klinisch und radiologisch untersucht. Material und Methoden: Ausgewertet wurden die Patientenunterlagen und Röntgenaufnahmen. Bei der Nachuntersuchung wurden sowohl die subjektiven als auch die objektiven Auffälligkeiten der in Nähe der Schrauben stehenden Zähne erhoben. Der Lockerungsgrad, die Zahnverfärbung, die Perkussionsempfindlichkeit sowie die Vitalität der Zähne wurden geprüft. Bei klinisch behandlungsbedürftigen Befunden wurde eine Röntgendiagnostik durchgeführt und die Behandlung in Zusammenarbeit mit dem Hauszahnarzt veranlasst. Ergebnisse: 157 Patienten (49 Frauen/108 Männer) wurden in die Studie eingeschlossen. 633 Schrauben wurden insgesamt inseriert. Davon hatten 563 einen radiologischen Kontakt mit Zähnen. Von diesen Patienten wurden 34,3 % nachuntersucht. Die Nachbeobachtungszeit betrug von 33,3 Monate im Durchschnitt. Es kam bei 27 Schrauben zu einem radiologischen Wurzeldefekt (4,8 %), wovon sechs Fälle behandlungsbedürftig waren: ein avitaler Zahn, eine Pulpaverkalkung, eine interne Pulparesorption und drei Wurzelfrakturen. Im Rahmen der Behandlung dieser Fälle erfolgten eine Zahnextraktion, eine Wurzelkanalbehandlung und vier Zähne werden durch Hauszahnarzt beobachtet. Schlussfolgerung: Die IMF-Schrauben sind eine zuverlässige Methode zur Okklusionssicherung, die aber zu Zahnwurzelverletzungen führen könnte. Hier empfiehlt sich die klinische und radiologische Nachuntersuchung und die Einleitung einer entsprechenden Therapie falls erforderlich. Es ist wichtig, die Schrauben mit dosierter Kraft zwischen den Eckzähnen und ersten Molaren auf Höhe der mukogingivalen Linie einzubringen, um Zahnwurzel-, Nerv- und Kieferhöhlenverletzungen zu vermeiden.

Page generated in 0.0691 seconds