• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 11
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 32
  • 30
  • 15
  • 15
  • 14
  • 12
  • 12
  • 11
  • 9
  • 9
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular /

Ribeiro Júnior, Paulo Domingos. January 2008 (has links)
Orientador: Osvaldo Magro Filho / Banca: Wilson Roberto Poi / Banca: Celso Koogi Sonoda / Banca: Maria Papageorge / Banca: Kalpakam Shastri / Resumo: Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas. / Abstract: This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey's test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones. / Doutor
32

Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida / Necessity of surgical retreatment in mandibular fractures after treatment by rigid internal fixation

Marcos Kazuo Yamamoto 10 August 2010 (has links)
As fraturas de mandíbula são freqüentes e o seu tratamento é por meio de fixação interna rígida. Complicações podem ocorrer após o tratamento das fraturas mandibulares levando a necessidade de reabordagem cirúrgica, havendo poucos estudos a esse respeito na literatura. A proposta deste estudo retrospectivo foi avaliar as características, os possíveis fatores de risco e os tipos de tratamento realizado em pacientes que necessitaram de reabordagem cirúrgica de fraturas de mandíbula tratadas com fixação interna rígida (FIR). Dentre 364 pacientes tratados por fraturas de mandíbula com FIR, houve 17 pacientes (4,7%) que necessitaram de reabordagem cirúrgica, tendo sido incluídos três pacientes provenientes de outros serviços, totalizando 20 casos com necessidade de nova cirurgia. Houve predomínio do gênero masculino, com idade média de 31,4 anos, sendo freqüentes o tabagismo e o etilismo. Foram freqüentes fraturas múltiplas e cominutivas nas regiões de corpo e ângulo mandibular, dente no traço e exposição intraoral da fratura. O tempo de espera para primeira cirurgia foi alto e o acesso extraoral e o sistema de fixação menos rígido 2.0 mm foram freqüentes. As complicações mais comuns foram dor, infecção e mobilidade anormal. Nas culturas bacterianas houve predomínio do Staphylococcus aureus e a imagem mais freqüente foi de reabsorção óssea difusa, seguida por parafuso solto, seqüestro ósseo, traço de fratura visível, fixação solta e placa fraturada. A reabordagem cirúrgica ocorreu em média de 7,5 meses após a primeira cirurgia e constou de remoção dos meios de fixação associada ou não a nova fixação ou ainda a remoção de seqüestro ósseo, sendo que apenas um caso necessitou de refratura. Histologicamente houve predomínio de osteomielite crônica. Os diagnósticos em ordem decrescente foram infecção, pseudoartrose, osteomielite e placa exposta, sendo que muitos pacientes tiveram mais de um diagnóstico. Foi destacada a freqüência de tabagismo e etilismo, fraturas múltiplas e cominutivas na região de corpo e ângulo mandibular, dente no traço, exposição intraoral, tempo de espera alto e acesso extraoral predispondo complicações das fraturas mandibulares e exames de imagem de reabsorção óssea, fixação e parafusos solto e seqüestro ósseo e diagnóstico histológico de osteomielite como característica dos casos requerendo nova cirurgia. / Mandibular fractures are frequent and their treatment is through rigid internal fixation (RIF). Complications can occur after treatment of the mandibular fractures which may require a new surgical procedure, and there are a few studies about that in the literature. The purpose of this retrospective study was to evaluate the characteristics, possible risk factors, and the kinds of treatment did in patients which needed another surgery after treatment of mandibular fracture with RIF. From 364 patients with mandibular fractures treated by RIF, there were 17 patients (4.7%) with need of a new surgery, and 3 patients coming from another city were included, comprising a total of 20 patients who needed a new surgery. There was predominance of the male gender, with a mean age of 31.4 years, being frequent smoking and alcohol abuse. Multiple and comminuted fractures on the body and angle sites, teeth in the fracture line, and intraorally exposed fractures were frequent. Delay time to the first surgery was high, and extraoral approaches and system 2.0mm were predominant. The most common complications were pain, infection and abnormal mobility. In the bacterial culture there was predominance of Staphylococcus aureus, and the most frequent radiographic images were of diffuse bone resorption, loosening of screws, bone sequestration, fracture line visible, loose fixation, and fractured plate. A new surgery occurred with a mean of 7.5 months after the first intervention and comprised plate and screws removal associated or not to a new fixation or bone sequestra removal, and only a case the fracture needed to be osteotomized. Histologically there was predominance of chronic osteomyelitis. The diagnoses in decreasing order were infection, nonunion, osteomyelitis and exposed plate, although many patients had more than one diagnosis. It was evidenced the frequency of smoking and alcohol abuse, multiple and comminuted fracture on the body and angle regions, teeth in the fracture line, intraoral fracture exposition, high delay time and extraoral approaches predisposing complications of the mandibular fractures, and images showing bony resorption, loose hardware and bone sequestra, as well as histological diagnosis of osteomyelitis as characteristic of the cases requiring a new surgery.
33

Efeitos do bloqueador de canais de cálcio amlodipina na reparação óssea em defeito cirúrgico no ramo mandibular de ratos / Effects of the calcium channel blocker amlodipine on bone healing of a surgical defect in the mandibular ramus of rats

Moraes, Rogerio Bonfante 29 September 2009 (has links)
Os anti-hipertensivos bloqueadores de canais de cálcio, por interferirem no transporte de cálcio através das membranas celulares, podem afetar muitos processos metabólicos, incluindo o metabolismo ósseo. O objetivo deste estudo foi avaliar, de forma radiográfica, histológica e bioquímica, os efeitos do bloqueador de canais de cálcio amlodipina no processo de reparo de um defeito ósseo, simulando fratura, no ramo mandibular de ratos. Foram utilizados 50 ratos machos Wistar, que foram submetidos ao mesmo procedimento cirúrgico unilateral simulando fratura mandibular, e distribuídos em dois grupos de 25 animais: grupo experimental, que receberam amlodipina, via oral, na dosagem de 0,04 mg / rato / dia, iniciando 12 dias antes do procedimento e continuando até o sacrifício; grupo controle, que permaneceu não tratado. Os animais foram sacrificados nos períodos de 1, 7, 14, 30 e 90 dias pós-operatórios. Foram realizados testes bioquímicos de fosfatase alcalina e cálcio séricos. Exame radiográfico foi obtido para mensuração da área radiolúcida do defeito ósseo. O estudo histológico compreendeu a análise descritiva do processo de reparo ósseo e a avaliação histomorfométrica da quantidade de osso neoformado. Os valores numéricos foram submetidos a análises estatísticas. A análise radiográfica demonstrou maior área radiolúcida no interior do defeito ósseo para o grupo experimental, nos períodos de 14 (p=0,016), 30 (p=0,009) e 90 (p=0,028) dias. Na análise histológica não se observaram atrasos no processo de reparo ósseo para ambos os grupos. Porém, na análise histomorfométrica, o grupo da amlodipina apresentou redução significante do volume de osso neoformado nos períodos de 7 e 14 dias (p=0,049), não havendo diferenças significativas no período de 30 dias. Houve redução significante nos níveis de fosfatase alcalina para o grupo da amlodipina nos períodos iniciais (p=0,049). Não houve alterações para os níveis de cálcio sérico. Concluiu-se que o uso crônico da amlodipina prejudicou a neoformação óssea no processo de reparo do defeito cirúrgico no ramo mandibular de ratos, porém não impediu a consolidação da fratura. / Antihypertensive, calcium channel blockers, which interfere on calcium transport across the cell membrane, may affect many metabolic processes, including bone metabolism. The aim of this study was to evaluate by radiographic, histologic and biochemical analyses the effects of calcium channel blocker amlodipine on bone healing of a defect simulating a fracture in mandibular ramus of rats. Fifty male Wistar rats were used, and submitted to the same unilateral surgical procedure simulating a mandibular fracture, distributed into two groups of 25 animals: experimental group, which received oral doses of 0.04 mg / rat / day starting 12 days before of procedure and continuing until sacrifice; control group, which remained untreated. Animals were sacrificed at 1, 7, 14, 30 and 90 days postoperatively. Blood biochemical tests of alkaline phosphatase and serum calcium were made. Radiographic examination was obtained in order to mensurate the radiolucent area of bone defect. Histological study comprised descriptive analysis of bone healing and histomorphometric analysis of the amount of newly formed bone. Numerical values were submitted to statistical analyses. Radiographic analysis showed larger radiolucent area into bone defect to the experimental group at the periods of 14 (p=0.016), 30 (p=0.009) and 90 (p=0.028) days. In the histological analysis there was no delay in the bone repair stages in both groups. However, in the histomorphometric analysis, the experimental group presented significative lowering of newly formed bone volume at 7 and 14 days periods (p=0.049), with no significant differences at 30 days period. There was significative decrease of alkaline phosphatase levels in experimental group in the initial periods (p=0.049). There was no change in the serum calcium levels. It was concluded that chronic use of amlodipine compromised bone neoformation in the repairing process of surgical defect in the mandibular ramus of rats, but no precluded occurrence of fracture consolidation.
34

"Efeitos da fratura de côndilo mandibular no crescimento da maxila e mandíbula: estudo experimental em ratos" / Effect of fracture of the mandibular condyle on growth of maxila and mandible: an experimental study in rats

Teixeira, Vanessa Castelo Branco 18 October 2004 (has links)
O presente estudo analisou os efeitos da fratura de côndilo unilateral, no período de crescimento. Para tanto, foram utilizados 50 ratos jovens, linhagem Wistar, com peso até 100g. Sob anestesia geral foi realizada no grupo experimental fratura do processo condilar no lado direito com desvio e no grupo controle-operado, foi feito apenas acesso cirúrgico ao côndilo. O sacrifício dos animais foi feito aos três meses de idade. A mandíbula foi desarticulada sendo obtidas as incidências radiográficas axial do crânio seco e lateral das hemi-mandíbulas. Foram feitas mensurações cefalométricas por meio de um sistema de computador. Foram aplicados os testes estatísticos “t" de Student entre os grupos e teste “t" de Student para dados pareados entre os lados, dentro de cada grupo.Houve diferença significante entre os grupos para o lado direito no comprimento das porções anterior (p=0,001) e posterior (0,017) da maxila e altura do ramo mandibular (p=0,001). Houve diferença significante entre os lados para o comprimento da mandíbula (p<0,001) e altura do ramo mandibular (p<0,001), nos grupos experimental e controle-operado. Houve diferença significante para a altura do corpo mandibular (p=0.001) e para o comprimento das porções anterior (p=0,002) e posterior (p=0,001) da maxila apenas no grupo experimental. Os resultados obtidos permitiram concluir que uma fratura de côndilo mandibular experimental durante o período de crescimento em ratos levou a uma assimetria da mandíbula na altura do corpo mandibular, com conseqüências também para a maxila. / The present study analyzed the effects of the condyle fracture were analyzed in the growing period in this study. Fifty young Wistar rats weighting 100g were used. Under general anestesia fracture of the condilar process on the right side with deviation was performed in the experimental group, while only the made surgical access was performed in the sham-operated group. The animals were sacrifized with three months of age. The mandible was disarticulated, and radiographic projections axial of dried skull and lateral of the hemimandible were obtained. Cephalometric mensurations through a computer system were made. Statistical tests "t" of Student between the groups and paired test "t" of Student among the sides, inside of each group were applied. There was a significant different among the groups to the right side in the length of the anterior portion (p=0,001) and posterior (0,017) of the maxilla and height of the mandibular ramus (p=0,001). There was significant difference among the sides for the length of the mandible (p <0,001) and height of the mandibular ramus (p<0,001), in the height of the body mandibular (p=0.001) and for the length of the anterior portions (p=0,002) and posterior (p=0,001) of the maxilla just in the experimental group. The obtained results allowed to conclude that a experimental fracture of mandibular condyle during the growing period in rats induced an asymmetry of the mandible in the height of the mandibular body, with also consequences to the maxilla.
35

Real-time mandibular angle reduction surgical simulator with haptic rendering. / 基于触觉绘制的实时下颌角缩小手术模拟系统 / CUHK electronic theses & dissertations collection / Ji yu chu jue hui zhi de shi shi xia han jiao suo xiao shou shu mo ni xi tong

January 2012 (has links)
下颌角缩小术是一种非常流行、有效、并广泛用于修饰脸部轮廓的手术方式。手术中所用到的主要工具有往复锯和圆头磨钻,这两种手术工具工作时有一个共同的特点:通过其高速运转去除骨质。缺乏经验的医生通常需要较长周期的训练,来学习和熟悉如何操作这两种手术工具,并在操作过程中避免由于无法控制好工具与骨骼的触碰以及工具运转时的在骨骼上的移动所造成的危险。具有视觉和触觉反馈的虚拟手术模拟系统为医生们练习手术技巧提供了一种可行并且安全的方式。然而,创建高速运转的手术工具与坚硬的骨骼之间的真实触觉交互模型是一个非常有挑战性的任务。 / 这篇论文设计并实现了虚拟下颌角缩小手术模拟系统,并且创建高保真度的视觉和触觉反馈来增强虚拟手术环境的真实性。文章提出了基于冲量理论的力反馈模型用来模拟作用在工具上的碰撞力和力矩。在不同的往复速率或者旋转速度的情况下,所提出的模型都可以为医生提供可信真实的力感反馈。并且针对磨钻在磨骨是震动明显对磨骨操作有较大影响的特点,论文还提出了一个三维震动模型来模拟磨骨时作用在钻轴上的橫向震动和轴向震动。同时,论文还提出了用于模拟手术中骨质去除以及重建的实时绘制方法。为了验证力模型的真实性,我们还创建了机械平台,采集磨骨和截骨过程中产生的真实力数据,从而用来与虚拟手术中产生的力数据进行比较。最后,还引入真实病人的CT扫描数据来对虚拟手术系统进行实证研究,评估创建的系统是否可以用于训练具有不同手术经验的医生。实证研究的结果也验证了所提出的虚拟手术系统的有效性。 / Mandibular angle reduction is a popular and efficient procedure widely used to alter the facial contour. The primary surgical instruments, the reciprocating saw and the round burr, employed in the surgery have a common feature: operating at a high-speed. Generally, inexperienced surgeons need a longtime practice to learn how to minimize the risks caused by the uncontrolled contacts and cutting motions in manipulation of instruments with high-speed reciprocation or rotation. Virtual reality (VR)-based surgical simulations with both visual and haptic feedbacks provide novice surgeons with a feasible and safe way to practise their surgical skill. However, creating realistic haptic interactions between a high-speed rotary or reciprocating instrument and stiff bone is a challenging task. In this work, a virtual reality-based surgical simulator for the mandibular angle reduction was designed and implemented. High-fidelity visual and haptic feedbacks are provided to enhance the perception in a realistic virtual surgical environment. The impulse-based haptic model was proposed to simulate the contact forces and torques on the instruments. It provides convincing haptic sensation for surgeons to control the instruments under different reciprocation or rotation velocities. Also, in order to mimic the lateral and axial burring vibration forces, a three dimensional vibration model has been developed. The real-time methods for bone removal and reconstruction during surgical procedures have been proposed to support realistic visual feedbacks. The simulated contact forces were verified by comparing against the actual force data measured through the constructed mechanical platform. An empirical study based on the patient-specific data was conducted to evaluate the ability of the proposed system in training surgeons with various experiences. The results confirm the validity of our simulator. / Detailed summary in vernacular field only. / Detailed summary in vernacular field only. / Wang, Qiong. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2012. / Includes bibliographical references (leaves 100-114). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese. / Abstract --- p.i / Acknowledgement --- p.v / Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Contributions of the Thesis --- p.5 / Chapter 1.2 --- Thesis Roadmap --- p.7 / Chapter 2 --- Related Work --- p.9 / Chapter 2.1 --- Virtual Orthopaedic Surgical Simulator --- p.9 / Chapter 2.2 --- Haptic Rendering for Virtual Surgery --- p.11 / Chapter 2.3 --- Evaluation of the Virtual System --- p.14 / Chapter 3 --- System Design --- p.17 / Chapter 3.1 --- Overall System Framework --- p.17 / Chapter 4 --- Bone-burring Surgical Simulation --- p.21 / Chapter 4.1 --- Impulse-Based Modeling of Haptic Simulation of Bone-Burring --- p.22 / Chapter 4.1.1 --- Basic Assumptions --- p.22 / Chapter 4.1.2 --- Bone-Burring Contact Description --- p.25 / Chapter 4.1.3 --- Burring Force Modeling --- p.29 / Chapter 4.2 --- Simulation of Bone Removal --- p.41 / Chapter 4.2.1 --- Bone Removal model --- p.41 / Chapter 4.2.2 --- Adaptive Subdividing Removal Surface --- p.42 / Chapter 4.3 --- Implementation and Experimental Results --- p.52 / Chapter 4.3.1 --- Force Evaluation --- p.53 / Chapter 4.3.2 --- Task-based Evaluation --- p.57 / Chapter 4.3.3 --- Time Performance --- p.61 / Chapter 5 --- Bone-sawing Surgical Simulation --- p.64 / Chapter 5.1 --- Impulse-Based Modeling of Haptic Simulation of Bone-Sawing --- p.65 / Chapter 5.1.1 --- Haptic Saw Instruments Description --- p.65 / Chapter 5.1.2 --- Sawing Force Modeling --- p.67 / Chapter 5.1.3 --- Sawing Torque Constraint --- p.70 / Chapter 5.2 --- Real-time Bone Mesh Reconstruction --- p.74 / Chapter 6 --- Evaluation --- p.78 / Chapter 6.1 --- Haptic Feedback Evaluation --- p.79 / Chapter 6.1.1 --- Mechanical Platform Setup --- p.79 / Chapter 6.1.2 --- Comparison of The Measured and Simulated forces --- p.81 / Chapter 6.2 --- Empirical Study --- p.85 / Chapter 6.2.1 --- Patient Specific Data --- p.87 / Chapter 6.2.2 --- Objective Performance Metrics --- p.89 / Chapter 6.2.3 --- Evaluation Results --- p.90 / Chapter 7 --- Conclusion --- p.94 / Publication List --- p.98 / Bibliography --- p.100
36

Estudo prospectivo da utilização do sistema de placas e parafusos 2.0-mm locking comparado com sistemas convencionais no tratamento de fraturas mandibulares / A prospective study of the use of 2.0-mm locking system plates compared with standard systems in the treatment of mandibular fractures

Camino Junior, Rubens 29 September 2016 (has links)
Um sistema mais adequado de fixação interna no tratamento de fraturas mandibulares é essencial para um bom resultado. Foi realizado um estudo comparativo da utilização do sistema de fixação 2.0-mm locking com sistemas convencionais no tratamento de fraturas mandibulares. Para este estudo, 87 pacientes consecutivos com 134 fraturas mandibulares foram divididos aleatoriamente para receber placas 2.0-mm locking (n = 45) ou convencionais 2.0-mm ou 2.4-mm (n = 42) e tiveram um seguimento mínimo de 6 meses. Foram obtidos dados pessoais, presença de doenças sistêmicas, abuso de substâncias, etiologia, politraumatismo e as localizações. As fraturas foram classificadas com base no grau de deslocamento e de complexidade. Foi mensurada a amplitude da abertura bucal. Análises estatísticas foram feitas na comparação entre grupos (p<= 0,050). Houve maior faixa etária (p = 0,010) e mais distúrbios gerais (p< 0,001) no Grupo Locking. Houve maior gravidade das fraturas (p= 0,004) no Grupo Convencional. Houve diferença significante para a localização das fraturas (p = 0,009), com mais casos na região de corpo no Grupo Locking. Houve aumento progressivo dos valores da abertura bucal, com diferença significante em ambos os grupos (p<= 0,050), sendo que o convencional apresentou melhor recuperação (47,2 ± 8,9 mm). Um caso de complicação pós-operatória maior ocorreu no Grupo Locking (2,2%) e três casos no Grupo Convencional (7,1%). Foi observado que o sistema 2.0-mm locking mostrou melhores resultados clínicos, pois ocorreu apenas um caso de complicação maior, porém o grupo convencional mostrou recuperação mais rápida da abertura bucal e, que também foi constatado que o sistema 2.0-mm locking foi efetivo no tratamento de fraturas desfavoráveis que necessitariam do sistema 2.4-mm convencional. / A more adequate system of internal fixation in the treatment of mandibular fractures is essential for a good result. A comparative study of the use of the 2.0-mm locking fixation system with conventional systems in the treatment of mandibular fractures was performed. For this study, 87 consecutive patients with 134 mandibular fractures were randomized to receive 2.0-mm locking plates (n = 45) or conventional 2.0-mm or 2.4-mm plates (n = 42) and had a minimum follow-up of 6 months. Fractures were classified based on the degree of displacement and complexity. The amplitude of mouth opening was measured. Statistical analyses were performed to compare groups (p <= 0.050). There were older age (p = 0.010) and more substance abuse (p = 0.001) in the Locking group. There was more complex fractures (p = 0.017) and teeth in the fracture line (p = 0.044) in the conventional group. There was a significant difference for the location of fractures (p = 0.009), with more cases in the body region in the Locking group. There was a progressive increase in the values of mouth opening, with a significant difference in both groups (p <= 0.050), whereas the conventional group showed better recovery (47.2 ± 8.9 mm). A case of major postoperative complication occurred in the Locking Group (2.2%) and three cases in the conventional group (7.1%). The 2.0-mm locking system showed better clinical outcomes because there was only one case of major complications and was effective in the treatment of unfavorable fractures that would require the conventional system 2.4-mm but the group treated with conventional systems showed faster recovery of mouth opening.
37

Avalia??o mec?nica in vitro utilizando miniplacas quadradas e retangulares do sistema 2.0 mm em fraturas da regi?o anterior de mand?bula

Oliveira, Kerlison Paulino de 18 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:48Z (GMT). No. of bitstreams: 1 KerlisonPO_DISSERT.pdf: 1641521 bytes, checksum: 5f1078757c465e02ee64ce8aff96f794 (MD5) Previous issue date: 2012-12-18 / The aim of this study was to comparatively evaluate the mechanical strength of squared and rectangular 2.0 mm system miniplates comparing them to the standard configuration with 2 straight miniplates in stabilizing fractures in the anterior mandible. Ninety synthetic polyurethane mandible replicas were used in mechanical test. The samples were divided into six groups of three different methods for fixation. Groups 1, 2 and 3 showed complete fractures in symphysis, characterized by a linear separation between the medial incisor, and groups 4, 5 and 6 showed complete fractures in parasymphysis with oblique design. Groups 1 and 4 were represented by the standard technique with two straight miniplates parallel to each other. Groups 2 and 5 were stabilized by squared miniplates and groups 3 and 6 were fixed by rectangular design. Each group was subjected to a mechanical test at a displacement speed of 10 mm/min on a universal testing machine, receiving linear vertical load on the region of the left first molar. The values of the maximum load and when displacements reached 5 mm were obtained and statistically analyzed by calculating the confidence interval of 95%. Fixation systems using squared (G2) and rectangular (G3) miniplates obtained similar results. No statistically significant differences with respect to the maximum load and the load at 5 mm displacement were found when compared to standard method in symphyseal fractures (G1). In parasymphysis the fixation method using squared miniplates (G5) obtained results without significant differences regarding the maximum load and the load at 5 mm when compared to the standard configuration (G4). The fixation method using rectangular miniplates (G6) showed inferior results which were statistically significant when compared to the standard configuration (G4) for parasymphysis fractures. The mechanical behavior of the fixation methods was similar, except when rectangular miniplates were used. The fixation methods showed better results with statistical significance in symphyseal fractures / O prop?sito deste estudo foi avaliar comparativamente a resist?ncia mec?nica de miniplacas quadradas e retangulares do sistema 2.0 mm, comparando-as ? configura??o padr?o, com 2 miniplacas retas, na estabiliza??o de fraturas na regi?o anterior de mand?bula. Noventa r?plicas de mand?bulas de poliuretano foram utilizadas no ensaio mec?nico. As amostras foram divididas em 6 grupos com 3 m?todos de fixa??o do sistema 2.0 mm. Os grupos 1, 2 e 3 apresentavam fraturas sinfis?rias completas, caracterizadas pela separa??o linear entre os incisivos mediais, e os grupos 4, 5 e 6 apresentavam fraturas parassinfis?rias completas com desenho obl?quo. Os grupos 1 e 4 foram representados pelo m?todo padr?o, com 2 miniplacas retas, dispostas paralelamente entre si. Os grupos 2 e 5 tiveram as mand?bulas estabilizadas por meio de miniplacas quadradas e os grupos 3 e 6, pelas retangulares. Cada grupo foi submetido a um teste mec?nico realizado por meio de uma m?quina de ensaio universal, na velocidade de 10mm/minuto, recebendo carga vertical linear na regi?o de primeiro molar esquerdo. Os valores da carga m?xima e da carga com deslocamento pr?-estabelecido em 5 mm foram obtidos e submetidos ? an?lise estat?stica a partir do c?lculo do intervalo de confian?a de 95%. Os sistemas de fixa??o utilizando miniplacas quadradas (G2) e retangulares (G3) obtiveram resultados similares, sem diferen?as estatisticamente significativas em rela??o ? carga m?xima e ? carga no deslocamento de 5 mm, quando comparada ? configura??o padr?o (G1), nas fraturas sinfis?rias da mand?bula. Nas fraturas parassinfis?rias, o m?todo de fixa??o utilizando miniplacas quadradas (G5) obteve resultados sem diferen?as estatisticamente significativas no que se refere ? carga m?xima e ? carga no deslocamento de 5 mm, quando comparadas ? configura??o padr?o (G4). O m?todo de fixa??o utilizando as miniplacas retangulares (G6) obteve resultados inferiores, estatisticamente significantes, quando comparado ? configura??o padr?o (G4) nas fraturas parassinfis?rias. O comportamento mec?nico dos m?todos de fixa??o estudados foi similar, exceto nas fraturas parassinfis?rias, quando se utilizaram as miniplacas com a configura??o retangular. Os m?todos de fixa??o utilizados apresentaram melhores resultados, com signific?ncia, nas fraturas sinfis?rias
38

Estudo comparativo entre a fixação interna e a fixação in-termaxilar no reparo ósseo de fraturas mandibulares por meio de imagem radiográfica digital

Queiroz, Christiano Sampaio January 2007 (has links)
111f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T15:07:00Z No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:49:28Z (GMT) No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5) / Made available in DSpace on 2013-05-08T11:49:28Z (GMT). No. of bitstreams: 9 Dissertação Christiano Queiroz9.pdf: 175521 bytes, checksum: 51b44b81e110bb6c6dc002a13333f327 (MD5) Dissertação Christiano Queiroz8.pdf: 155984 bytes, checksum: f5c4a46d60e77b0718848fab96f85373 (MD5) Dissertação Christiano Queiroz7.pdf: 1461220 bytes, checksum: 621ab609ba799dba10e909031c8cccc9 (MD5) Dissertação Christiano Queiroz6.pdf: 1474051 bytes, checksum: c8186f90fc20cb7c9db3cd0f92c1c773 (MD5) Dissertação Christiano Queiroz5.pdf: 860472 bytes, checksum: 1e0bb30340dc455ba5886425887a6b73 (MD5) Dissertação Christiano Queiroz4.pdf: 145777 bytes, checksum: 002d8ab1dd097ffae4cef5a4ac414724 (MD5) Dissertação Christiano Queiroz3.pdf: 175599 bytes, checksum: 87cbe8be31bd0209f31d80cfd461be9c (MD5) Dissertação Christiano Queiroz2.pdf: 159009 bytes, checksum: 8b8dae41086fcfc427e8a67780010cc4 (MD5) Dissertação Christiano Queiroz1.pdf: 195113 bytes, checksum: 4c0bba61fcc22b702a39d4a21f319e93 (MD5) Previous issue date: 2007 / A avaliação radiográfica convencional da consolidação de fraturas é um método pouco confiável, não apenas por depender da experiência do examinador, como também da qualidade do exame. Desta forma, imagens seriadas que apresentem densidade e contraste não uniformes ou diferenças de projeção geométrica podem determinar o diagnóstico incorreto da reparação de fraturas após seu tratamento. Mesmo imagens consideradas suficientes para o diagnóstico podem não permitir a observação de mudanças sutis nos tecidos mineralizados devido à sua baixa sensibilidade e devido à limitada acuidade visual humana. O emprego, entretanto, de métodos de investigação mais sensíveis e objetivos poderia aumentar a acurácia dessa avaliação. Este estudo objetivou comparar, por meio de radiografias panorâmicas digitalizadas, a reparação dos traços de fraturas mandibulares, após a instituição de duas formas diferentes de tratamento: a redução aberta, seguida da imobilização dos fragmentos com materiais de fixação interna (grupo controle), e a redução fechada com a fixação intermaxilar (grupo teste). Para isto, os pacientes foram submetidos a três exames radiográficos pós-operatórios (uma semana, um mês e três meses após o tratamento), que, após digitalizados (600 dpi, 8 bits), foram corrigidos em brilho e tamanho no Programa Photoshop. Em seguida essas imagens foram analisadas por três diferentes métodos no Programa ImageTool®: análise visual no vídeo, mensuração da média e do coeficiente de variação dos níveis de cinza e por subtração radiográfica digital. Os resultados revelaram a predominância de áreas de neoformação óssea no grupo tratado com fixação interna, em todos os tempos avaliados. Assim, pode-se concluir que a redução aberta com fixação interna das fraturas mandibulares determinou uma reparação em menor tempo que a redução fechada por meio da fixação intermaxilar. / Salvador
39

Tratamento cirúrgico intrabucal das fraturas de ângulo mandibular com uma miniplaca de titânio: estudo clínico e radiográfico

Érnica, Natasha Magro [UNESP] 22 November 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-11-22Bitstream added on 2014-06-13T20:11:19Z : No. of bitstreams: 1 ernica_nm_me_araca.pdf: 751223 bytes, checksum: d94eb6ddda581dfccf846aec58f63e11 (MD5) / O objetivo deste estudo foi avaliar, clínica e radiograficamente, pacientes com fraturas de ângulo mandibular tratadas por meio de redução cirúrgica e fixação com uma miniplaca de titânio de 2,0 mm de espessura, associada a parafusos monocorticais. Foram avaliados retrospectivamente 21 pacientes, com 22 fraturas fraturas de ângulo mandibular, tratados pela equipe de Cirurgia e Traumatologia Buco-Maxilo- Facial da Faculdade de Odontologia de Araçatuba - UNESP, na Santa Casa de Misericórdia de Araçatuba e Santa Casa de Misericórdia de Birigüi, Estado de São Paulo, no período de julho de 1999 a fevereiro de 2002. Todas as fraturas de ângulo mandibular avaliadas foram fixadas utilizando uma miniplaca de 2,0 mm de espessura, com parafusos monocorticais, disposta ao longo da linha oblíqua mandibular, sem utilização de fixação intermaxilar no pós-operatório. O tempo de proservação variou de 6 a 44 meses, com média de 15 meses e 1 dia. Foi observada, para essas fraturas, incidência de 14,3% de complicações pós-operatórias, sendo 4,8% infecção, 4,8% má-oclusão e 4,8% distúrbios sensoriais - hiperestesia no local de retenção da miniplaca. Dentre as complicações, a única que exigiu nova intervenção cirúrgica sob anestesia local foi a infecção pós-operatória. Assim, pode-se concluir que o método empregado foi clinicamente adequado para o tratamento de fraturas simples de ângulo mandibular, a presença de apenas uma miniplaca não interferiu no índice de complicações pós-operatórias, e o método evitou a fixação intermaxilar pós- operatória. / The aim of this study was to evaluate clinical and radiographic, mandibular angle fractures treated by open reduction and one single 2.0 mm titanium miniplate fixation associated with monocortical screws. The author retrospectively evaluated 21 patients, with 22 mandibular angle fractures, operated by Oral and Maxillofacial Surgery Division from the Dental School of Araçatuba, UNESP, Brazil, during the period from July 1999 to February 2002. All mandibular angle fractures studied were treated by open reduction and internal fixation with one single 2.0 mm miniplate, positioned along the mandible oblique line, without post-operative intermaxilar fixation. Follow-up ranged from 6 to 44 months, with a mean of 15 months and 1 day. Complications occurred in 3 patients (14,3%). One patient (4,8%) presented post-operative infection, one (4,8%) malocclusion, and one (4,8%) sensory disturbance - hyperesthesia in the region of the retained miniplate. The only case requiring a further surgical intervention under general anesthesia was the infection case. Thus, results allowed to conclude that the fixation method was suitable for treatment of simple mandibular angle fractures, the presence of only one single miniplate did not interfere on the post-operative complication rate, and the method avoided post-operative intermaxilar fixation.
40

"Efeitos da fratura de côndilo mandibular no crescimento da maxila e mandíbula: estudo experimental em ratos" / Effect of fracture of the mandibular condyle on growth of maxila and mandible: an experimental study in rats

Vanessa Castelo Branco Teixeira 18 October 2004 (has links)
O presente estudo analisou os efeitos da fratura de côndilo unilateral, no período de crescimento. Para tanto, foram utilizados 50 ratos jovens, linhagem Wistar, com peso até 100g. Sob anestesia geral foi realizada no grupo experimental fratura do processo condilar no lado direito com desvio e no grupo controle-operado, foi feito apenas acesso cirúrgico ao côndilo. O sacrifício dos animais foi feito aos três meses de idade. A mandíbula foi desarticulada sendo obtidas as incidências radiográficas axial do crânio seco e lateral das hemi-mandíbulas. Foram feitas mensurações cefalométricas por meio de um sistema de computador. Foram aplicados os testes estatísticos “t” de Student entre os grupos e teste “t” de Student para dados pareados entre os lados, dentro de cada grupo.Houve diferença significante entre os grupos para o lado direito no comprimento das porções anterior (p=0,001) e posterior (0,017) da maxila e altura do ramo mandibular (p=0,001). Houve diferença significante entre os lados para o comprimento da mandíbula (p<0,001) e altura do ramo mandibular (p<0,001), nos grupos experimental e controle-operado. Houve diferença significante para a altura do corpo mandibular (p=0.001) e para o comprimento das porções anterior (p=0,002) e posterior (p=0,001) da maxila apenas no grupo experimental. Os resultados obtidos permitiram concluir que uma fratura de côndilo mandibular experimental durante o período de crescimento em ratos levou a uma assimetria da mandíbula na altura do corpo mandibular, com conseqüências também para a maxila. / The present study analyzed the effects of the condyle fracture were analyzed in the growing period in this study. Fifty young Wistar rats weighting 100g were used. Under general anestesia fracture of the condilar process on the right side with deviation was performed in the experimental group, while only the made surgical access was performed in the sham-operated group. The animals were sacrifized with three months of age. The mandible was disarticulated, and radiographic projections axial of dried skull and lateral of the hemimandible were obtained. Cephalometric mensurations through a computer system were made. Statistical tests "t" of Student between the groups and paired test "t" of Student among the sides, inside of each group were applied. There was a significant different among the groups to the right side in the length of the anterior portion (p=0,001) and posterior (0,017) of the maxilla and height of the mandibular ramus (p=0,001). There was significant difference among the sides for the length of the mandible (p <0,001) and height of the mandibular ramus (p<0,001), in the height of the body mandibular (p=0.001) and for the length of the anterior portions (p=0,002) and posterior (p=0,001) of the maxilla just in the experimental group. The obtained results allowed to conclude that a experimental fracture of mandibular condyle during the growing period in rats induced an asymmetry of the mandible in the height of the mandibular body, with also consequences to the maxilla.

Page generated in 0.0789 seconds